Ahead of the Curve for Large, Multiclass Lists by Mass Spec

Similar documents
FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

Fast, Rugged Raptor Columns with Time-Tested Selectivity

Proteins: Characteristics and Properties of Amino Acids

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

Apply Force to Your LC Methods

A Plausible Model Correlates Prebiotic Peptide Synthesis with. Primordial Genetic Code

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

Definitive EtG/EtS LC-MS/MS Analysis:

Bringing uhplc Performance to the Separation of Peptides

LC Technical Information

Amino Acids and Peptides

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Exam III. Please read through each question carefully, and make sure you provide all of the requested information.

Potentiometric Titration of an Amino Acid. Introduction

Separation of Large and Small Peptides by Supercritical Fluid Chromatography and Detection by Mass Spectrometry

penta-hilic UHPLC COLUMNS

Properties of amino acids in proteins

LC and LC/MS Column Selection Flow Chart

Solutions In each case, the chirality center has the R configuration

Collision Cross Section: Ideal elastic hard sphere collision:

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

penta-hilic UHPLC COLUMNS

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Lecture 15: Realities of Genome Assembly Protein Sequencing

Basic Principles for Purification Using Supercritical Fluid Chromatography

Changing the way you think about HPLC

Chemistry Chapter 22

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

BGB Flash Cartridges. Ultra-pure silica-based material. High-performance spherical 30 µm C18, CN, Diol & HILIC. Pressure up to 27 bar (400 psi)

Studies Leading to the Development of a Highly Selective. Colorimetric and Fluorescent Chemosensor for Lysine

ultimate efficiency unleashed [ Cortecs 1.6 µm columns ]

Translation. A ribosome, mrna, and trna.

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

BENG 183 Trey Ideker. Protein Sequencing

A rapid and highly selective colorimetric method for direct detection of tryptophan in proteins via DMSO acceleration

Protein Structure Bioinformatics Introduction

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Using Higher Calculus to Study Biologically Important Molecules Julie C. Mitchell

C18 Column. Care & Use Sheet

1.7 m Fortis UHPLC Columns

Alltech Alltima HP Introduction

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Content : Properties of amino acids.. Separation and Analysis of Amino Acids

Viewing and Analyzing Proteins, Ligands and their Complexes 2

INTRODUCTION. Amino acids occurring in nature have the general structure shown below:

Read more about Pauling and more scientists at: Profiles in Science, The National Library of Medicine, profiles.nlm.nih.gov

for Acclaim Mixed-Mode HILIC-1 Column

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

Protein structure. Protein structure. Amino acid residue. Cell communication channel. Bioinformatics Methods

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Part 2. Overview of HPLC Media

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Lecture'18:'April'2,'2013

Small Molecule Selectivity Sampler

Gemini-NX Performance paired with Axia Technology

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

CHEMISTRY ATAR COURSE DATA BOOKLET

Routine MS Detection for USP Chromatographic Methods

Chemical Properties of Amino Acids

New Product Update. HPLC Columns

1.7µm Fortis UHPLC Columns

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Analytical Instrumentation

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

Alternatives to Sub-2 µm UHPLC Columns

It s hot! ZIC -chilic

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Packings for HPLC. Packings for HPLC

IN QUALITATIVE ANALYSIS,

Exam I Answer Key: Summer 2006, Semester C

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

Breaking the speed limit: Fast, high-resolution peptide and tryptic digest separations using fused-core particles

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Next Generation of Phenyl Columns. Chromatography Products.

High Performance Liquid Chromatography

Acclaim Mixed-Mode WAX-1 Columns

LIQUID CHROMATOGRAPHY

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Chemical derivatization

InertSustainSwift C8

Successfully Scaling and Transferring HPLC and UPLC Methods

How proteins separate on reverse-phase HPLC

Comparison of different aqueous mobile phase HPLC techniques

Protein Struktur (optional, flexible)

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Principles of Biochemistry

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Transcription:

Stationary Phase: ARC-18 Selectivity Accelerated Ahead of the Curve for Large, Multiclass Lists by Mass Spec Si O Pure Chromatography www.bgb-info.com/raptor www.restek.com/raptor 1

The Raptor ARC-18 Column With Raptor LC columns, Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or core-shell particles) with the resolution of highly selective USLC technology. This new breed of chromatographic column allows you to more easily achieve peak separation and faster analysis times without expensive UHPLC instrumentation. The birth of Restek s Raptor SPP LC column line began with the innovative Biphenyl phase, but it has quickly grown to include a new Restek phase: the ARC-18. Designed and intended specifically for use on LC-MS/MS systems, the Raptor ARC-18 column features a well-balanced retention profile without the drawbacks of using an ordinary C18 in the harsh, acidic mobile phases needed for mass spectrometry (MS). Even after extended use in these low-ph ( 2.0) conditions, the sterically protected ARC-18 offers consistent retention, peak shape, and response for charged bases, neutral acids, small polar compounds, and more. For the rapid analysis of large, multiclass assays by LC-MS/MS, the acid-resistant Raptor ARC-18 truly is ahead of the curve. Column Description: Si O Stationary Phase Category: C18, octadecylsilane (L1) Ligand Type: Sterically protected C18 Particle: 2.7 μm or μm superficially porous silica (SPP or core-shell ) Pore Size: 90 Å Surface Area: 10 m 2 /g (2.7 μm) or 100 m 2 /g ( μm) Recommended Usage: ph Range: 1.0 8.0 Maximum Temperature: 80 C Maximum Pressure: 600 bar / 8,700 psi (2.7 μm) or 400 bar /,800 psi ( μm) Properties: Well-balanced retention profile. Sterically protected to resist harsh, low-ph mobile phases. Ideal for use with sensitive detectors like mass spec. Switch to an ARC-18 when: You are analyzing large, multiclass lists by LC-MS/MS. Strongly acidic (ph 1 3) mobile phases are required. Column Interaction Profile: Solute Retention Profile: Hydrophobic Dispersion H-Bonding Dipolar Acidic Basic Polarizability Cation Exchange 0 2 4 6 8 10 Target Analyte Structure: Hydrocarbons Defining Solute Interaction: Dispersion Target Analyte Functionalities: Hydrophobic compounds Protonated bases Complementary Solute Interactions: Hydrogen bonding Cation exchange 2 www.restek.com/raptor www.bgb-info.com/raptor

A New Proprietary Bonded Phase Born for LC-MS/MS The new Raptor ARC-18 column was designed to stand up to even the harshest acidic MS conditions. It utilizes a proprietary bonding procedure that arranges our sterically protected ligand to resist acid hydrolysis and, therefore, also resist phase degradation and bleed. This cutting-edge column lets you increase ionization and boost sensitivity in your mass spec by using low-ph mobile phases without the fear of retention drift over time. ARC-18 columns maintain a stable retention profile (Figure 1) in mobile phases well under ph 2.0. Figure 1: Steric protection helps the Raptor ARC-18 column endure low-ph MS mobile phases without sacrificing retention. % loss k 0 - -10 % loss of retention (k) vs. hours at ph 1 Flow Rate: 0.6 ml/min Temperature: 60 C MPA: 1% Trifluoroacetic Acid (aq.) MPB: Acetonitrile Time 0 7. 7.1 0.01 60 %B 4 4 100 4 4-1 -20-2 0 10 20 30 40 0 60 70 80 90 100 Hours Raptor ARC-18 Competitor A FPP C18 Competitor B FPP C18 Competitor C FPP C18 Competitor D SPP C18 Competitor E SPP C18 Competitor F SPP C18 Part of the USLC column set! RESTEK USLC Ultra Selective Liquid Chromatography Learn more about USLC technology, phase profiles, and more at www.restek.com/uslc www.bgb-info.com/raptor www.restek.com/raptor 3

The New Standard for Reproducibility for SPP Core-Shell Columns To keep your productivity high and your lab expenses low, we know that Raptor ARC-18 columns must produce exceptional selectivity and fast analysis times not just once, but every time. Ruggedness and repeatability are essential, which is why from the silica and the bonding technique, to the packing process and upgraded hardware, every decision that went into creating this column was made to ensure superlative reproducibility, from injection to injection (Figure 2) and from lot to lot (Figure 3). We also adopted new quality control (QC) specifications to guarantee the retention time stability you need for worry-free analyses. Figure 2: Even after hundreds of injections with a highly acidic mobile phase like 0.2% formic acid, a Raptor ARC-18 column will provide consistent, reliable data. After 00 injections, pesticide compounds are well within narrow, 1-second MRM windows! One of the greatest advantages of an SPP column is the ability to operate at higher linear velocities without losing efficiency as you would with a conventional fully porous particle column. But, these higher velocities can also generate higher backpressures that rob you of performance. Like all Raptor columns, our new ARC-18 can handle increased pressures, and handle them longer than other manufacturers SPP columns, to help you achieve Selectivity Accelerated while offering outstanding reproducibility and maintaining efficiency even in aggressive MS conditions. Injection 00 Injection 1 0.00 0.0 1.00 1.0 2.00 2.0 3.00 3.0 4.00 4.0.00.0 6.00 6.0 7.00 LC_FF03 Column: Raptor ARC-18 (cat.# 9314A12); Dimensions: 100 mm x 2.1 mm ID; Particle Size: 2.7 µm; Temp.: 0 C; Sample: LC multiresidue pesticide standard #1 (cat.# 31972); Diluent: Water; Conc.: 20 ng/ml; Inj. Vol.: µl; Mobile Phase: A: Water + 2 mm ammonium formate + 0.2% formic acid, B: Methanol + 2 mm ammonium formate + 0.2% formic acid; Gradient (%B): 0.00 min (%), 2.00 min (60%), 4.00 min (7%), 6.00 min (100%), 7.00 (100%), 7.01 min (%), 9.0 (%); Flow: 0.4 ml/min; Detector: Waters Xevo TQ-S; Ion Source: Waters Zspray ESI; Ion Mode: ESI+; Mode: MRM; Instrument: Waters ACQUITY UPLC I-Class Figure 3: From one lot to the next, every Raptor ARC-18 column you purchase will perform the same. Lot 1 Lot 2 Excellent lot-to-lot reproducibility helps ensure longevity for critical workflows. Lot 3 Lot 4 Column: Raptor ARC-18 (cat.# 9314A12); Dimensions: 100 mm x 2.1 mm ID; Particle Size: 2.7 µm; Temp.: 0 C; Sample: LC multiresidue pesticide standard #1 (cat.# 31972); Diluent: Water; Conc.: 20 ng/ml; Inj. Vol.: µl; Mobile Phase: A: Water + 2 mm ammonium formate + 0.2% formic acid, B: Methanol + 2 mm ammonium formate + 0.2% formic acid; Max Pressure: 2 bar; Gradient (%B): 0.00 min (%), 2.00 min (60%), 4.00 min (7%), 6.00 min (100%), 7.00 (100%), 7.01 min (%), 9.0 (%); Flow: 0.4 ml/min; Detector: Waters Xevo TQ-S; Ion Source: Waters Zspray ESI; Ion Mode: ESI+; Mode: MRM; Instrument: Waters ACQUITY UPLC I-Class LC_FF042 Lot 1.0 2.00 2.0 3.00 3.0 4.00 4.0.00.0 6.00 4 www.restek.com/raptor www.bgb-info.com/raptor

Well-Balanced Retention to Quickly Separate Large, Multiclass Analyte Lists In order to analyze large lists of compounds, especially across multiple classes, your column must be capable of spreading analytes out over the gradient to ensure accurate detector response and quantitation. In designing the Raptor ARC-18 column, we adjusted our bonding procedures to form an ideal ligand density that offers balanced retention for the rapid analysis of large, multiclass assays. As shown in Figure 4, even a 204-compound pesticide screen can be reliably completed in just 9. minutes. The Raptor ARC-18 column exhibits the balanced retention, selectivity, and performance needed for critical multiclass workflows in any industry or lab. Figure 4: With its balanced retention profile, the Raptor ARC-18 column is ideally suited to analyze large, cross-class compound lists. For a complete compound list, visit www.restek.com/lc-multiresidue select the LC Multiresidue Pesticide Kit (cat.# 31971). 204 pesticides in just 9. minutes! Column: Raptor ARC-18 (cat.# 9314A12); Dimensions: 100 mm x 2.1 mm ID; Particle Size: 2.7 µm; Temp.: 0 C; Sample: LC multiresidue pesticide kit (cat.# 31971); Diluent: Water; Conc.: 20 ng/ml; Inj. Vol.: µl; Mobile Phase: A: Water + 2 mm ammonium formate + 0.2% formic acid, B: Methanol + 2 mm ammonium formate + 0.2% formic acid; Max Pressure: 2 bar; Gradient (%B): 0.00 min (%), 2.00 min (60%), 4.00 min (7%), 6.00 min (100%), 7.00 (100%), 7.01 min (%), 9.0 (%); Flow: 0.4 ml/min; Detector: Waters Xevo TQ-S; Ion Source: Waters Zspray ESI; Ion Mode: ESI+; Mode: MRM; Instrument: Waters ACQUITY UPLC I-Class 0.00 0.0 1.00 1.0 2.00 2.0 3.00 3.0 4.00 4.0.00.0 6.00 6.0 7.00 LC_FF041 Note: When combining a large number of compounds with different chemical functionalities, mix stability can be an issue. In formulating our LC multiresidue pesticide standard kit (cat.# 31971), we extensively studied the 204 compounds involved, then grouped them into as few mixes as possible while still ensuring maximum long-term stability and reliability. For quantitative analysis, we recommend analyzing each mix separately to ensure accurate results for every compound. To view separate chromatograms of each mix, visit www.restek.com/lc-multiresidue www.bgb-info.com/raptor www.restek.com/raptor

Speed Up Challenging Analyses with Simple Mobile Phases and Methods From food safety to bioanalytical work, getting reliable, reproducible data by LC often requires specialty instrumentation or columns, complex mobile phases, or long runs. Instead of wasting time and resources and making your job harder in the process you can greatly improve your productivity by selecting a better column for your existing instrumentation. By switching to a Raptor ARC-18 column for your LC-MS/MS analyses, you can increase your sample throughput and make your job easier by maintaining, or even improving, your data quality using simple mobile phases and a typical HPLC system. Put the ARC-18 to work in your lab today to experience Selectivity Accelerated! Amino Acids with Standard Columns on UV or Mass Spec Instead of purchasing specialty amino acid columns or dedicated analyzers, use Raptor ARC-18 columns with your standard HPLC and UV detector to perform routine analyses of 23 common amino acids. Using 9-fluorenylmethyl-chloroformate (FMOC) derivatization and simple mobile phases, you can separate, detect, and quantitate amino acids without specialty instrumentation (Figure ). Because of the ARC-18 s compatibility with MS-friendly mobile phases, these UV methods can also be easily transferred to your mass spectrometer. And since it is a Raptor column, it will hold up to extended use without losing selectivity or performance. Figure : Raptor ARC-18 columns exhibit excellent retention and resolution of amino acids derivatized with FMOC, including isomers leucine and isoleucine. Conc. Peaks tr (min) (µmole/ml) 1. Arginine (Arg).14 0.4 2. Asparagine (Asn).18 0.4 3. Glutamine (Gln).630 0.4 4. trans-4-hydroxyproline (Hyp).878 0.4. Serine (Ser) 6.139 0.4 6. Aspartic acid (Asp) 6.26 0.4 7. Glutamic acid (Glu) 6.696 0.4 8. Threonine (Thr) 7.027 0.4 9. Glycine (Gly) 7.466 0.4 10. Alanine (Ala) 8.227 0.4 11. Proline (Pro) 8.803 0.4 12. Methionine (Met) 9.324 0.4 13. Valine (Val) 9.37 0.4 14. Norvaline 9.66 0.4 1. Tryptophan (Trp) 9.910 0.4 16. Phenylalanine (Phe) 10.120 0.4 17. Isoleucine (Ile) 10.214 0.4 18. Leucine (Leu) 10.28 0.4 19. Cystine 10.749 0.2 20. Histidine (His) 12.04 0.4 21. Lysine (Lys) 12.174 0.4 22. Cysteine (Cys) 12.463 0.4 23. Tyrosine (Tyr) 12.801 0.4 1 2 6 3 7 8 9 4 FMOC-OH 10 11 12 13 14 1 16 17 18 19 23 compounds resolved in less than 13 minutes! 20 21 22 23 4.00.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 13.00 14.00 LC_FF039 Column: Raptor ARC-18 (cat.# 9314A1E); Dimensions: 100 mm x 3 mm ID; Particle Size: 2.7 µm; Temp.: 30 C; Sample: Diluent: 0.1 N HCl; Conc.: 0.4 µmole/ml for each amino acid (0.2 µmole/ml for cystine); Inj. Vol.: 1 µl; Mobile Phase: A: 0.1% Formic acid + 20 mm ammonium formate in water, B: 0.1% Formic acid + 10 mm ammonium formate in 90:10 acetonitrile:water; Gradient (%B): 0.00 min (20%), 6.2 min (40%), 9.00 min (60%), 10.00 min (60%), 13.00 (100%), 13.01 min (20%), 1.00 (20%); Flow: 0.8 ml/min; Detector: UV/Vis @ 26, 4.8 nm; Instrument: Waters Acquity UPLC H-Class; Notes: Derivatization reaction: 0 µl amino acid mix + 100 µl 0.2 N borate buffer (ph 10.0) + 0 µl 1 mm 9-fluorenylmethyl-chloroformate solution + 0 µl acetonitrile; The injection can be performed after minutes of reaction time. 6 www.restek.com/raptor www.bgb-info.com/raptor

Figure 6: The ARC-18 makes quick work of fat-soluble vitamins A, D, E, and K by LC-MS/MS Peaks tr (min) Precursor Ion Product Ion 1. Retinol 1.46 269.4 93.3 2. Vitamin D2 3.2 397. 379.6 3. Vitamin D3 3.8 38. 367. 4. γ-tocopherol 3.78 417.6 11.4. α-tocopherol 4.12 431.7 16.4 6. Vitamin K1.23 41.4 187.3 1 0.0 0. 1.0 1. 2.0 2. 3.0 3. 4.0 4..0. 6.0 6. Column: Raptor ARC-18 (cat.# 9314A12); Dimensions: 100 mm x 2.1 mm ID; Particle Size: 2.7 µm; Temp.: 40 C; Sample: Diluent: Methanol; Conc.: 100 ng/ml; Inj. Vol.: µl; Mobile Phase: A: 0.1% Formic acid + mm ammonium formate in water, B: 0.1% Formic acid + mm ammonium formate in methanol; Max Pressure: 190 bar; Gradient (%B): 0.00 min (90%), 4.0 min (100%),.0 min (100%),.01 min (90%), 7.0 (90%); Flow: 0. ml/min; Detector: ABSCIEX API 4000 ; Ion Source: TurboIonSpray ; Ion Mode: ESI+; Mode: MRM; Instrument: Shimadzu UFLCXR Figure 7: The ARC-18 also resolves vitamin D metabolites by LC-MS/MS with the same column and mobile phases 2 2 3 4 Peaks tr (min) Conc. Q1 Q3 (ng/ml) 1. 1,2-Dihydroxyvitamin D3 0.88 200 399.4 381. 2. 2-Hydroxyvitamin D3 1.33 200 401. 383. 3. 2-Hydroxyvitamin D2 1.41 200 413. 39. 4. Vitamin D2 3.47 200 397. 379.6. Vitamin D3 3.3 200 38. 367. 6 LC_FF037 Fat-Soluble Vitamins and Metabolites with Accelerated Run Times Separating fat-soluble vitamins by LC can be timeconsuming. The Raptor ARC-18 column, however, can analyze these difficult compounds using reversed-phased chromatography (RPC) in less time than traditional columns to increase productivity. The ARC-18 also stands up to the low-ph, MSfriendly mobile phases that promote ionization and fast separation while providing the balanced retention profile necessary for this important food safety workflow (Figure 6). Plus, in the bioanalytical arena, the ARC-18 can quantitate the metabolites of vitamin D using the same column and mobile phases (Figure 7). Toxic Substances in Agricultural Matrices Using LC When it comes to analyzing toxic substances in agricultural matrices (e.g., aflatoxins in wheat), speed is of paramount importance. A Raptor ARC-18 column retains and separates these compounds with simple mobile phases in a rapid time frame that maximizes your productivity (Figure 8). Figure 8: The ARC-18 elutes four common aflatoxins in under 1. minutes with an overall cycle time of 2. minutes! Peaks tr (min) Q1 Q3 Quantifier Q3 Qualifier 1. Aflatoxin G2 1.07 331.1 24.1 189.1 2. Aflatoxin G1 1.13 329.0 243.1 200.1 3. Aflatoxin B2 1.23 31.0 29.1 287.1 4. Aflatoxin B1 1.29 313.0 28.1 241.1 3 4 1 0.0 0. 1.0 LC_CF086 1. 2.0 2. 3.0 3. 4.0 4..0. 6.0 Column: Raptor ARC-18 (cat.# 9314A12); Dimensions: 100 mm x 2.1 mm ID; Particle Size: 2.7 µm; Temp.: 40 C; Sample: Diluent: Methanol; Conc.: 200 ng/ml; Inj. Vol.: µl; Mobile Phase: A: 0.1% Formic acid + mm ammonium formate in water B: 0.1% Formic acid + mm ammonium formate in methanol; Gradient (%B): 0.00 min (90%), 4.00 min (100%), 4.01 min (90%), 6.00 (90%); Flow: 0. ml/min; Detector: ABSCIEX API 4000 ; Ion Source: TurboIonSpray ; Ion Mode: ESI+; Instrument: Shimadzu UFLCXR 0.9 1.0 1.1 1.2 1.3 1.4 1. LC_FF038 Column: Raptor ARC-18 (cat.# 9314AE); Dimensions: 0 mm x 3.0 mm ID; Particle Size: 2.7 µm; Temp.: 4 C; Sample: Diluent: Acetonitrile:water (0:0); Conc.: 100 ng/ml; Inj. Vol.: 10 µl; Mobile Phase: A: mm Ammonium formate + 0.1% formic acid in water; B: 0.1% Formic acid in methanol; Gradient (%B): 0.00 min (3%), 1.0 min (9%), 1.1 min (3%), 2.0 (3%); Flow: 0.700 ml/min; Detector: Applied Biosystems/MDS Sciex LC-MS/MS; Ion Source: TurboIonSpray ; Ion Mode: ESI+; Instrument: Shimadzu UFLCXR www.bgb-info.com/raptor www.restek.com/raptor 7

For Consistent Retention, Peak Shape, and Response with Mass Spec, Grab the Column that Thrives in Low ph Conditions Raptor ARC-18 LC Columns 2.1 mm 3.0 mm 4.6 mm Length cat.# cat.# cat.# 2.7 µm Columns 30 mm 9314A32 9314A3E 9314A3 0 mm 9314A2 9314AE 9314A 100 mm 9314A12 9314A1E 9314A1 10 mm 9314A62 9314A6E 9314A6 µm Columns 30 mm 93143E 0 mm 93142 9314E 9314 100 mm 931412 93141E 93141 10 mm 931462 93146E 93146 20 mm 93147 EXP Reusable Fittings for HPLC & UHPLC for 10-32 fittings and 1 /16" tubing Effortlessly achieve 8,700+ psi HPLC seals by hand! (Wrench-tighten to 20,000+ psi.) Hybrid titanium/peek seal can be installed repeatedly without compromising your seal. Description qty. cat.# EXP Hand-Tight Fitting (Nut w/ferrule) ea. 2937 EXP Hand-Tight Fitting (Nut w/ferrule) 10-pk. 2938 EXP Hand-Tight Nut (w/o Ferrule) ea. 2939 Hybrid Ferrule U.S. Patent No. 820184, Optimize Technologies. Optimize Technologies EXP Holders are Patent Pending. Other U.S. and Foreign Patents Pending. The Opti- prefix is a registered trademark of Optimize Technologies, Inc. Raptor EXP Guard Cartridges Hand-Tight Fitting No Tools Needed! Unidirectional Raptor EXP Guard Column Cartridge Holder Body Auto-Adjusting Titanium Hybrid Ferrule ZDV Connections! Protect your investment and extend the life of our already-rugged LC columns and change guard column cartridges by hand without breaking fluid connections no tools needed! EXP Direct Connect Holder Description qty. cat.# EXP Direct Connect Holder for EXP Guard Cartridges (includes hex-head fitting & 2 ferrules) ea. 2808 Raptor EXP Guard Column Cartridges Particle x 2.1 mm x 3.0 mm x 4.6 mm Description Size qty. cat.# cat.# cat.# Raptor ARC-18 EXP Guard Cartridge 2.7 µm 3-pk. 9314A022 9314A023 9314A020 Raptor ARC-18 EXP Guard Cartridge µm 3-pk. 9314022 9314023 9314020 Maximum cartridge pressure: 600 bar / 8,700 psi (2.7 µm) or 400 bar /,800 psi ( µm) Raptor SPP LC columns combine the speed of SPP with the resolution of USLC technology. Learn more at www.restek.com/raptor Experience Selectivity Accelerated. Order the Raptor ARC-18 today at www.bgb-info.com/raptor DR-BGB-118 www.bgb-info.com Switzerland: BGB Analytik AG Rohrmattstrasse 4 4461 Böckten Phone +41 61 991 00 46 Fax +41 61 991 00 2 sales@bgb-analytik.com BGB Analytik SA Route de Pré-Bois 20 121 Genève 1 Phone +41 22 788 49 43 Fax +41 22 788 49 4 sales.fr@bgb-analytik.com Austria: BGB Analytik Vertrieb GmbH Josefstrasse 19a 79618 Rheinfelden Phone +49 7623 7173110 Fax +49 7623 7173199 sales.de@bgb-analytik.com BGB is authorized Restek distributor for Austria and Switzerland.