Experiment. Quantification of Ascorbic acid by Fluorescence Spectroscopy1

Similar documents
Determining the Rate Law and Activation Energy for the Methyl Blue Reaction:

Experiment 18 - Absorption Spectroscopy and Beer s Law: Analysis of Cu 2+

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

Skill Building Activity 2 Determining the Concentration of a Species using a Vernier Spectrometer

Introduction to Spectroscopy: Analysis of Copper Ore

Introduction to Spectroscopy: Analysis of Copper Ore

ASCORBIC ACID METHOD FOR PHOSPHORUS DETERMINATION

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

Experiment #9. Atomic Emission Spectroscopy

Introduction to Spectroscopy: Analysis of Copper Ore

Introduction to Spectroscopy: Analysis of Copper Ore

DETERMINATION OF AN EQUILIBRIUM CONSTANT

Experiment 7. Determining the Rate Law and Activation Energy for the Reaction of Crystal Violet with Hydroxide Ion

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

Experiment #7. Determination of an Equilibrium Constant

Experiment 8: DETERMINATION OF AN EQUILIBRIUM CONSTANT

Fluorescence Spectrophotometry

Experiment 11 Beer s Law

Experiment 11 Beer s Law

LAB #3: FLUROESCENCE SPECTROSCOPY AND ELECTRON TRANSFER (This lab is adapted from the U of MN Phsyical Chemistry lab manual)

Absorption Spectra of Cyanine Dyes

Chemistry 213. A KINETIC STUDY: REACTION OF CRYSTAL VIOLET WITH NaOH LEARNING OBJECTIVES

ENTHALPY OF FORMATION OF MgO

Laboratory Measurements and Procedures

Introduction to Spectroscopy: Analysis of Copper Ore

A Fluorometric Analysis of Quinine in Tonic Water

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1

CHM 152 updated May 2011 Lab 6: Experimentally Determining an Equilibrium Constant using Spectrophotometry

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013

Spectrophotometric Determination of an Equilibrium Constant

FLAME PHOTOMETRY AIM INTRODUCTION

Rate law Determination of the Crystal Violet Reaction Using the Isolation Method

Lab Investigation 4 - How could you make more of this dye?

Determination of an Equilibrium Constant

Chemistry 1215 Experiment #11 Spectrophotometric Analysis of an Unknown Brass Sample

Experiment 7A ANALYSIS OF BRASS

often display a deep green color due to where the SPR occurs (i.e., the wavelength of light that interacts with this specific morphology).

Ascorbic Acid Titration of Vitamin C Tablets

Spectroscopy II Introduction: Spectrophotometry and Fluorometry

LAB #1: ABSORPTION SPECTRA OF CONJUGATED DYES

CHM112 Lab Iodine Clock Reaction Part 2 Grading Rubric

Figure 1. Structures of compounds to be analyzed by IR.

Zinc Metal Determination Perkin Elmer Atomic Absorption Spectrometer AAnalyst Procedures

Experiment 13I THE REACTION OF RED FOOD COLOR WITH BLEACH 1

aa + bb cc + dd Equation 1

CHEM 122 LABORATORY SKILLS EXAMINATION

Rate Law Determination of the Crystal Violet Reaction. Evaluation copy

Bio 120 Lab 5: Quantitative Analysis

Chemical Reactions: The Copper Cycle

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION

Ascorbic Acid Titration of Vitamin C Tablets

Experiment 10 Dye Concentration Using a UV-Vis Spectrophotometer

Kinetics of Crystal Violet Fading AP* Chemistry Big Idea 4, Investigation 11 An Advanced Inquiry Lab

Kinetics of Crystal Violet Fading AP Chemistry Big Idea 4, Investigation 11 An Advanced Inquiry Lab (adapted by Flinn Scientific, Inc.

EXPERIMENT 7. Determination of Sodium by Flame Atomic-Emission Spectroscopy

Ascorbic Acid Titration of Vitamin C Tablets

Titration with an Acid and a Base

#11. Chemical Equilibrium

Experiment 2: Analysis of Commercial Bleach Solutions

Spectroscopy. Page 1 of 8 L.Pillay (2012)

CHM112 Lab Determination of an Equilibrium Constant Grading Rubric

Kinetics of Crystal Violet Bleaching

For simplicity, we ll represent BTB s ionization in a solution by the equilibrium: HBTB = H + + BTB -

So, What Does it Indicate?

MEASUREMENT: PART II

ANALYSIS OF ZINC IN HAIR USING FLAME ATOMIC ABSORPTION SPECTROSCOPY

EXPERIMENT 6 INTRODUCTION TO SPECTROSCOPY

Redox Titration of Ferricyanide to Ferrocyanide with Ascorbic Acid Spectroelectrochemistry: Redox Titration Using Vitamin C

Energy. Position, x 0 L. Spectroscopy and the Particle-in-a-Box. Introduction

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

Ascorbic Acid Titration of Vitamin C Tablets

Atomic Spectra for Atoms and Ions. Light is made up of different wavelengths

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

Determination of the K a of a Weak Acid and the K b of a Weak Base from ph Measurements

Safety Note: Safety glasses and laboratory coats are required when performing this experiment

VISIBLE SPECTROSCOPY

Experiment 12: SPECTROSCOPY: EMISSION & ABSORPTION

The Determination of an Equilibrium Constant

Acid / Base Titrations

Lab 11: Must what goes in be the same as what comes out? Spectroscopy & Fluorescence in Chlorophyll.

Pre-Lab Exercises Lab 2: Spectroscopy

K a Acid Dissociation Constant Minneapolis Community and Technical College Principles of Chemistry II, C1152 v.9.13

Developing a Spectrophotometric Quantitative Assay for p-nitrophenol

Introduction. Molecules, Light and Natural Dyes. Experiment

The Fluorometric Determination of Acetylsalicylic Acid in an Aspirin Tablet

Chem 321 Lecture 18 - Spectrophotometry 10/31/13

The following are excerpted from the lab manual with a couple of extra figures for your guidance.

A Fluorometric Analysis of Quinine in Tonic Water

V. LAB REPORT. PART I. ICP-AES (section IVA)

Atomic Theory: Spectroscopy and Flame Tests

A Study of Beer s Law Prelab

KINETICS: INITIAL RATES

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION

Chemical Equilibrium: Finding a Constant, Kc

O H 3 O 1 1 A. O 1 1 OH (K w

Percentage of Acetic Acid in Vinegar

A COMPLEX IRON SALT & BEER S LAW

Experiment 20-Acid-Base Titration: Standardization of KOH and Determination of the Molarity and/or Percent Composition of an Acid Solution

Answers to spectroscopy questions. 1. Consider the spectrum below. Questions a f refer to this spectrum.

Chesapeake Campus Chemistry 111 Laboratory

Transcription:

Experiment. Quantification of Ascorbic acid by Fluorescence Spectroscopy Modified 10/2017 Experiment. Quantification of Ascorbic acid by Fluorescence Spectroscopy1 Objective: The goal of this experiment is to determine an unknown concentration of ascorbic acid (AA) by monitoring the emission of methylene blue (MB) by fluorescence spectroscopy. The analysis will require excitation of MB at 664 nm and monitoring the emission at 682nm. The analysis requires a calibration curve to determine the concentration of ascorbic acid in an unknown sample Equipment Fluorolog Spex-3 2-mL and 10mL Vol flask Chemicals Quartz Cells Various Vol pipette Methylene Blue Ultra high purity water Ascorbic Acid Safety and Waste Disposal Wear gloves when performing this experiment Wash hands and expose skin after handling with methylene blue (MB) and all chemicals handled in this experiment. Discussion: In this experiment, the amount of ascorbic acid in an unknown be measured by Fluorescence. Ascorbic acid (AA) or Vitamin-C does not fluoresce. Methylene Blue (MB), a member of thiazine dye, is reduced to the colorless leuco form Leuco-Methylene Blue (LMB) in the presence of ascorbic acid. The concentration of AA is based on the decrease of the fluorescent signal of MB as it is reduced to LMB. The fluorescence intensity can therefore be related to the concentration of ascorbic acid. Fluorescence is the subsequent emission of radiation after the absorption of radiant energy. Although all molecules absorb radiant energy, not all molecules fluoresce to get back to the ground electronic state. In the absorption process, the electron in the molecule gets excited from the ground electronic state to an excited electronic state. Although molecules absorb a range of wavelengths, in fluorescence spectroscopy, only one wavelength is chosen as the excitation wavelength. Therefore, electrons are excited to a specific higher energy level. Upon excitation, the molecule undergoes vibrational relaxation to the lowest vibrational level of the excited state. From here, the electron can emit radiation (fluoresce) to get back to the ground electronic state. Like the excited electronic state, the ground electronic state has a series of vibrational levels. Therefore, the molecule can fluoresce (give off light) to any of these vibrational levels of the ground electronic state. However, in fluorescence spectroscopy, the emission is monitored at only one specific wavelength known as the emission wavelength. A schematic of this process as it occurs in the Fluorescence spectrometer is shown in the Jablonski Energy Diagram. Notice in the diagram that there are 6 emissions, but only the emission resulting in the return to the ground excited state is being monitored by the Fluorescence spectrometer. At low concentrations, the intensity of the fluorescence is proportional to concentration. At high concentrations, however, the compound will absorb some of the fluoresced light, resulting in a non-linear dependence of the fluorescence intensity on the 1 Chem. Pharm. Bull. 3(10) 121 124 (200)

concentration. Another reason not to use high concentrated sample is that the spectrometer has an upper limit on the signal it can handle. (A way to decrease the intensity without diluting the sample is to narrow the slit setting). In this experiment, the fluorescence bands of MB can be monitored at 664 nm upon excitation at 682nm. The emission peak of MB at 682 nm decreases due to the decrease of its concentration upon reduction of MB by AA. If quantitative work is going to be done, then there must be some sort of relationship between Fluorescence intensity and concentration. The equation that describes this relationship is: P F = Φ F P o εbc In this equation, P F is the radiant power of Fluorescence. Recall that power is in watts, which have units of J/sec. In this application, power is basically a measure of the number of photons being emitted from the sample. Φ F is the quantum yield of fluorescence ( photons emitted / photons absorbed ), and P o is the radiant power directed at the sample. The product εbc is the absorption of the Fluorescing species at the emission wavelength and have the usual definitions. This factor accounts for the molecules in the solution that absorb the Fluorescence before it can escape the solution. Because neighboring molecules in the sample can absorb the Fluorescence of a molecule, the linear relationship shown above does not hold at high concentrations. Specifically, the absorption (the εbc factor) needs to be less than 0.0. To have such low absorptions, the solution needs to be very dilute. Another factor in experimental design is that it is not possible to build a spherical detector to measure all of the emission from the sample. Instead, the emission is collected at a 90 angle to the excitation source. This angle minimizes interference from the excitation wavelength. Clearly, only part of the Fluorescence is actually measured. In this experiment, working solutions of MB (2.0 10-3 mm). A calibration curve of MB with concentration range of 3.0 60.0 10-7 M should be prepared to test the stability and detection limit. Standard solutions of ascorbic acid should also be prepared. Before working on the Fluorolog-3, go to the Miramar Instrument website and download the operation procedures. http://faculty.sdmiramar.edu/fgarces/labmatters/instrument.htm#fluorolog Warning: You will be issued matching sets of quartz cuvette. Do not damage these otherwise you will be billed $400.

Experiment. Quantification of Ascorbic acid by Fluorescence Spectroscopy Modified 10/2017 Procedure Use deoxygenated Ultra-pure water in all the solution preps. 1. Ascorbic Acid (AA) Stock solution- Prepare a fresh stock solution of AA (0.0100 M). It should be prepared on the same day that the solution is to be used. This solution is prepared by dissolving 44. mg of AA in 2mL of deoxygenated, ultra pure water. Measure the mass of AA to the precision of the Analytical balances. Lower concentration of AA is made by dilution with deoxygenated, ultra pure water. Store the solutions in amber-colored bottles in the dark. 2. Methylene Blue (MB) Stock solution- Stock solution of 1.00 mm MB is prepared by dissolving appropriate of the MBCl xh 2 O, (x = 2, or 3) in deoxygenated ultra pure water. Solutions of lower concentration were prepared by dilution of the stock with deoxygenated ultra pure water. 3. Preparation of unknown solutions- Prepare your unknown solution daily no more than 3h prior to use by dissolving 44mg of AA in 2 ml deoxygenated ultra-pure water. Working solutions of lower concentration may be prepared by appropriate dilution with deoxygenated water if you choose that option. All solutions are to be handled in the same manner as the AA stock solution above. In this experiment, you will be given the freedom to prepare appropriate concentrations for the analysis with the following guidelines. 4 Methylene Blue Stability Test Prepare 6 8, 10-mL solutions of MB with concentration ranges of 1.0 10-7 M to 20 10-7 M. Be sure to also run a blank consisting with only deoxygenated ultra pure water. Methylene Blue with known concentrations of Ascorbic Acid. Prepare 6-8, 10-mL solutions of 2.0 10-6 M MB solutions, each reacted with AA at different concentrations. The concentration range of AA should be 6-8 1.0 10-6 M to 1.0 10-4 M. Be sure to also run a sample of MB with no AA and a sample consisting with only deoxygenated ultra pure water. 6 Methylene Blue with unknown Ascorbic Acid Take your unknown solution and prepare four (4) diluted solutions at various concentration (similar to the AA knowns solutions in #). React each with 2.0 10-6M MB as in step # above. Don t forget to also run a sample of MB with no AA and a sample consisting with only deoxygenated ultra pure water. 7 Measuring Fluorescence of solutions Your instructor will show you how to use the Spex-Fluorlog instrument. After demonstrating to the first student(s) how to use the instrument, that student will teach the next user and so on. Results and Calculations 1. Calculate the concentrations for the Methylene Blue solutions prepared in step 4 above. Generate a table of MB concentration and Emission Intensities. Next overlay the graph and include it in your report. (See figure to right)

2. Calculate the concentrations for the Methylene Blue solutions and Ascorbic Acid as prepared in step above. Generate a table of MB concentration and Emission Intensities. Next overlay the graph and include it in your report. (See figure to right). Plot Ascorbic Acid concentration versus emission intensities. This is your calibration curve. See graph on next page. 3. Use Excel to generate a calibration curve and then determine the concentration of ascorbic in your unknown solution. (Chapter 4 Harris). Following the example in chapter 4.7-4.9, p 83-89, use LINEST in your least square analysis to find S y, S x, S m and S b. Determine the error (standard deviation and coefficient of variation) in your determination of the ascorbic acid concentration. See equation 4-27 and the example in chapter.3 (page 106, Harris 8 th Ed) 4. Compare the results for your unknown with the results you determined in experiment 3 and experiment 4. Carry out a Comparing Replicate Measurement analysis. Compare experiment 6 with 3 and experiment 6 with 4. Also restate your results in the comparison of experiment with 3. Are the set of results lie within experimental error? See p. 76 in your text (Harris, 8 th Edition). Calculate the percent concentration m:m of ascorbic of your unknown and determine the standard deviation, RSD, CV and 9% CL for your results. 6 Print a hard copy of your excel spread sheet that is properly formatted to fit a single page with proper labels and turn it in with your write-up. Discussion (Talking points) Discuss the Comparing Replicate Measurement analysis of ascorbic acid in this experiment with your other method of ascorbic acid analysis, experiment 3 (iodometric titration) and experiment 4 (cyclic voltammetry of ascorbic acid) Do the results significantly different or do the results lie within experimental error? Write an appropriate discussion on the technique of fluorescence spectroscopy for quantitative analysis. Why is the derivatization of ascorbic acid necessary in this experiment? Can this technique be applied to any chemical that do not fluoresce? Postlab Question 1. Two fluorescent compounds A and B are present in a mixture. Using a spectrofluorimeter similar to the one used in this experiment, how would you determine the quantity of A in the mixture if- A absorbs radiation in a region where B does not. Both A and B absorb in the same region but A emits fluorescence at different wavelengths than B. 2. List at least two reasons fluorescence spectroscopy is far more sensitive than UV-Vis spectroscopy?

Experiment. Quantification of Ascorbic acid by Fluorescence Spectroscopy Modified 10/2017 Quantification of Ascorbic Acid by Fluorescence Spectroscopy Analytical Chemistry 21 # CRITERIA (Tentative point distribution - may change depending on experiment) pts % 1 Introduction and Procedures A. Introduction Objective of Expt. Background information on Fluorescence spectroscopy Math relationship used in terms of fluorescence intensity and concentration and calibration curve setup B. Procedures Outline of procedures in Expt. Flow chart pictorial of procedures. Solution preparation and dilution procedure to be carried out. Procedural changes. Information (data) to be recorded during expt. (to be presented in Table form.) Safety and disposal information. This portion of the report should be turned in before the start of lab class (prelab discussion). 2 Data, Observe., Results and Calc. C. Data and Observation Write out how solutions are prepared and how the dilution procedure was carried out. How is the instrument set up. What instrument settings were used. Write a detained description on the important steps in using the instrument. Data in table form. & detail observation written in the table. Indicate the instrument settings as well. This portion of the report should be turned in before you leave the laboratory. 3 Calculations & Results D. Calculations Data to be used in the in the calibration curve. LINEST result and calculation of unknown concentration. Statistical analysis of data and the standard deviation of the results E. Results Final Result(s) in table form. In this section accuracy of results is very important as well as detailed calculation showing how the result was obtain. "Unknown" will also be included in this section. 4 Discussion / Conclusions and Post-Lab Questions F. Discussion Discuss the percent error in your calculation. Write an appropriate discussion on the technique of fluorescence spectroscopy for quantitative analysis. What is the role of o-phenylenediamine in this experiment? Can this technique be applied to any chemical that do not fluoresce? How would this be altered if instead of using a calibration curve, standard addition was used in the analysis. G. Conclusion Summary of the goal of the experiment, how does the result compared to the literature value and how that goal was achieved in the experiment. H. Post-lab questions from manual or class assignment Complete well thought-out answers. This portion (Calculation and Discussion) is turned in at the beginning of class of the due-date Overall Presentation (of lab notebook) Lab technique during experiment; example are, class preparation, safety glasses precautions and leaving the laboratory clean. Report presentation: examples are the headings of each report that includes name, title, lab partner, date and section #. Legibility of report. Is the report easy to read or is important information jotted down by small print in the corners of the lab report. The overall impression is important. Lab Technique Safety: wear goggles, handle chemicals with caution, proper handling of lab equipment Leave lab clean and tidy Total (This total may be adjusted depending on lab technique and student conduct in the experiment) 100% Unknown 30pts 9 6 10