IR 40. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 0~1000

Similar documents
IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

GS-IR 8816 Series Infrared Thermometer

INFRARED THERMOMETER Model : TM-959

Infrared Sensors. Operators manual thermometer CSL-SF50 / CSLM-2HSF300

Operator s Manual. optris CSlaser. LT/ hs LT/ 2M/ G5. Infrared-thermometer

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

optris CS/ CSmicro Infrared Sensor Operators manual

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

Infrared Thermometer Model: and

INFRARED THERMOMETER TM0819

Infrared Thermosensor ES1C

Infrared Hand-Held Thermometers

IT Series Infrared thermometer Using manual

63/66/68. Infrared Thermometers. Users Manual

Non contact temperature measurement

Operator s Manual. optris CSmicro LT/ LTH/ LTHS/ 2M/ 3M. Infrared-thermometer

IR-SA Series Infrared radiation thermometer for Processing Model : IR-SAI IR-SAS IR-SAH

Data Sheet. Infra-red Temperature Measurement

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

Infrared Hand-Held Thermometers

Introduction to Blackbody Sources

CS Series. Capacitance Type. Type. Proximity Sensor. Features

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

New! 2010 Model. Model No

Introduction Cautions

Xenics Presentation. A 25 minute crash course in Thermography

Ground Penetrating Radar & By Mike Kelty Western Technologies Inc.

INSTRUCTION MANUAL DTH Fax: (503)

Have a look at the following video which shows an invention developed in the High-Low Tech Lab at MIT.

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Instruction Manual SEFRAM Thermal Camera

INFRARED TEMPERATURE SENSORS OPERATION AND SELECTION

Friction Contact friction is the force that develops between two surfaces in contact as they attempt to move parallel to their interface.

THERMOCOUPLE CHARACTERISTICS TRAINER

ø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.

Model DIT-516/517: OPERATING MANUAL

Fibel_GB_U.qxd :37 Uhr Seite 2. Manual for Infrared Measuring Technology

M2 V0 IN ON A POLE. Material Aluminium Polycarbonate. Finish White Transparent TECHNICAL CHARACTERISTICS

Tap Changer Type MHF III Specification, Assembly and Materials

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

Sensor Technology Summary

TEMPERATURE AND THERMAL EXPANSION

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Thermal Interface Material Performance Measurement

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

(PT-A6) Visible Light Detector for Security Lighting

Dr. Michael Müller. Thermal Management for LED applications

(PT-A6) Visible Light Detector for Security Lighting

CONDUCTORS, INSULATORS, AND ELECTRON FLOW

Circular Motion and Centripetal Force

Thermometers. Applications

Emissivity and Remote Sensing

L 18 Thermodynamics [3] Heat flow. Conduction. Convection. Thermal Conductivity. heat conduction. Heat transfer

MR medium rating busbar

The following table of work functions for metals may be helpful for some of the problems in this homework:

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

D i s t a n ce Sensor DS 60

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL

Acceleration/Velocity/Displacement VIBRATION METER

Operating Instructions for Digital Manometer. Model: MAN-SD

Year 8 Exam Revision. Theme 1 & 2 Chemistry. TBAT gain your target grade on the Year 8 exam

Section 7. Temperature Measurement

V 12: Miniature photoelectric switches in M 12 housings

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

MAGNETIC FIELDS & UNIFORM PLANE WAVES

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

Installation guide 862 MIT / MIR

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

Emissivity and Remote Sensing

ERELLA WEB PIN 278 RECESSED WEB PIN 406 CEILING WEB PIN 649 MULTI-ARM WEB PIN 393 WALL WEB PIN SN OP SN OP CB SN FW

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Weather Station P03/3-Modbus-GPS for Modbus

PHOS 15 LED PROJECTOR

Operator's Manual. optris BR 400. Calibration source

optris LaserSight Operators manual

Fitting PS P - B - R2

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

S P E C I F I C A T I O N S

Strain Gauges and Accessories

Specification LY521. <080924> Rev. 0.3 Document No. : SSC-QP (Rev.00) Drawn Approval Approval. Rev. 00 December

Infrared Temperature Calibration 101 Using the right tool means better work and more productivity

ED 701 General Industry Pressure Transmitter

Resistivity and Temperature Coefficients (at 20 C)

Chemical Behavior of Metals

Heat and Temperature

MKIII -MB USER S GUIDE 09/18/18. Rev. 3

User s Guide. Shown with Built-in Laser Sighting. OS531, OS532, OS533, OS534 OMEGASCOPE Handheld Infrared Thermometer

Critical parameters of

473-SHX Dew Point Mirror

More Precision. Non-contact IR temperature sensors

Operating instructions Infrared temperature sensor TW20xx TW21xx

33-40 vessels vessels

CHEM Principles of Chemistry II. Chapter 17 - Electrochemistry

Transcription:

Non-Contact Infrared Temperature Sensor/Transmitter Temperature Range: 0~1000 IR 40 C-910C, Bupyeong Woolim Lion s Valley, #425, Cheongcheon-Dong, Bupyeong-Gu, Incheon, Korea TEL: +82-32-623-7507 FAX: +82-32-623-7510 E-mail: sales@gasdna.com Web: www.gasdna.com

1. FEATURES IR-40 non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) and RS-485 communication signal output. It can measure from -20 to maximum 1000 in the distance of 40:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. Applications: Plastics, Fluids, Rubber, Coated components, Asphalt, Wood, Paper, Ceramics, Textiles, Glass, Food etc. 2. Ordering information Code Number IR-40- - - MODEL IR-40 Code A Temperature Range 1 0~700 2 0~1000 3-20~1000 Z Code B M N V Code C Other Output 0~20mA 4~20mA Voltage Output(DC 1~5V) Cable Length 1 3m Cable Z Other Description 3. Accessories Description Shape Usage Remark Fixing nut Mounting sensor Basic accessory Mounting bracket Mounting sensor Basic accessory

4. SPECIFICATIONS Segment Specification Measurement Range 0~1000 Device Accuracy Repeatability Thermopile ±1% / full scale ±1% of reading Field of View(D:S) 40:1 Optical spectrum wave 8~14μm Responsive Time 0.5 sec or below Emissive rate 0.10~0.99 Analog Output Communication output signal 4~20mA, 1~5V(option) RS-485 communication signal Power DC 20~24V(Max 50mA) Ambient temperature(no water cooling) 0~70 Temperature Resolution 0.1 Warm up Period 1 to 2 minutes Operating Relative Humidity 5~90% Operating Ambient Temperature -30~85 Waterproof IP65, NEMA 4 Laser pointer Dimensions Signal Cable Casing material Weight Cable length 630~670nm(red) Ø47 172(L) 4 wire shield type Aluminum Alloy 430g 3m(standard), other(option) 5. OPTICAL FIELD OF VIEW (D:S 40:1) DISTAN CE: SEN SO R TO O BJEC T (IN ) ) I N ( *. I A D T O P S 20 0.5 40 1.0 59 79 1.5 2.0 D :S =40 :1 ) M M ( *. I A D T O P S 13 5 00 25 100 0 38 150 0 50 20 00 DISTAN CE: SEN SO R TO O BJEC T (M M ) *FO CU S PO INT D :S = 40:1 FAR FIELD D :S = 40:1

6. Laser pointer & Adjust of Emissivity (. X X ) EMISSIVITY ADJUST EMISSIVITY 6 7 8 9 0 5 1 2 4 3 6 7 8 9 0 5 1 2 4 3 LASER S/W LZ [ Emissivity adjustment] Please rotate the emissivity adjustment dial on the back side of sensor to change the emissivity. Please refer to Emissivity table on page 10. [Laser pointer] To aim object, Please activate laser pointer. Please push laser switch LZ for laser pointers on/off. 7. DIMENSION

8. Accessories / Options Adjustable Bracket Air-purge M51(P1) TAP Air and Water-cooler housing

9. Wiring No. Wire color Usage 1 Red Power 24VDC(+) 2 Black Power 0V(-) 3 White RS485 A 4 Green RS485 B 5 Yellow Analogue output(+) 6 Blue AGND(-) 10. COMMUNICATION SPECIFICATION Serial Interface(Default value) Baud Rate: 4800 baud Data bits: 8 Parity: none Stop bits: 1

11. INSTALLATION Please make sure the target area is larger than the field of view. Best Good Incorrect SENSOR Target diameter Equal to view field Target diameter Larger than view field Target diameter Less than view field Background The spot size is decided by the distance from the sensor to the target. Please refer to the section 5. Optical field of view and make sure your target area is larger than the field of view. Please locate the sensor vertical against the target. It is the best for you to install the sensor vertical against the target area or object. If it is not available, the sensor should be more than 45 against the target area. Otherwise, it can affect the measuring accuracy. Object α<45

Please avoid the heat reflection from other high temperature materials Furnace roof Furnace roof Furnace roof Object Object Object Refiection from wrong angle Change the angle to avoid refiection Install shielding panel to avoid refiection Please avoid highlight. Highlight Object Shelter Please avoid electronic noise. Please avoid the high frequency or high voltage area such as motor, pump, power line, and so on. Check sensor and wiring No. Wire color Usage 1 Red Power 24VDC(+) 2 Black Power 0V(-) 3 White RS485 A 4 Green RS485 B 5 Yellow Analogue output(+) 6 Blue AGND(-)

12. Emissivity Table Appendix A Emissivity Table Metals Material Typical Emissivity Non oxidized 0,02-0,1 Aluminium Polished 0,02-0,1 Roughened 0,1-0,3 Oxidized 0,2-0,4 Polished 0,01-0,05 Brass Roughened 0,3 Oxidized 0,5 Polished 0,03 Copper Roughened 0,05-0,1 Oxidized 0,4-0,8 Chrome 0,02-0,2 Gold 0,01-0,1 Haynes Alloy 0,3-0,8 Electro polished 0,15 Inconel Sandblast 0,3-0,6 Oxidized 0,7-0,95 Non oxidized 0,05-0,2 Iron Rusted 0,5-0,7 Oxidized 0,5-0,9 Forged, blunt 0,9 Iron, casted Non oxidized 0,2 Oxidized 0,6-0,95 Polished 0,05-0,1 Lead Roughened 0,4 Oxidized 0,2-0,6 Magnesium 0,02-0,1 Mercury 0,05-0,15 Molybdenum Non oxidized 0,1 Oxidized 0,2-0,6 Monel (Ni-Cu) 0,1-0,14 Nickel Electrolytic 0,05-0,15 Oxidized 0,2-0,5 Platinum Black 0,9 Silver 0,02 Polished plate 0,1 Rustless 0,1-0,8 Steel Heavy plate 0,4-0,6 Cold-rolled 0,7-0,9 Oxidized 0,7-0,9 Tin Non oxidized 0,05 Titanium Polished 0,05-0,2 Oxidized 0,5-0,6 Wolfram Polished 0,03-0,1 Zinc Polished 0,02 Oxidized 0,1

Appendix B Emissivity Table Non-Metals Material Typical Emissivity Asbestos 0,95 Asphalt 0,95 Basalt 0,7 Carbon Non oxidized 0,8-0,9 Graphite 0,7-0,8 Carborundum 0,9 Ceramic 0,95 Concrete 0,95 Glass 0,85 Grit 0,95 Gypsum 0,8-0,95 Ice 0,98 Limestone 0,98 Paint Non alkaline 0,9-0,95 Paper Any color 0,95 Plastic >50µm Non transparent 0,95 Rubber 0,95 Sand 0,9 Snow 0,9 Soil 0,9-0,98 Textiles 0,95 Water 0,93 Wood Natural 0,9-0,95