InfraRed Thermometer with Laser Pointer

Similar documents
HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

INFRARED THERMOMETER TM0819

INFRARED THERMOMETER Model : TM-959

Dual laser + type K thermometer INFRARED THERMOMETER

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Introduction Cautions

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

Infrared Thermometer Model CA879

566/568. Infrared Thermometers. Getting Started

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

Noncontact Thermometer

Manual Dew point scanner PCE-DPT 1

IR/Thermistor Pen. Instruction Manual

INSTRUCTION MANUAL Fax: (503)

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

Instruction Manual SEFRAM Thermal Camera

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

INF195 Infrared Thermometer

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Mini Environmental Quality Meter

Infrared Hand-Held Thermometers

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

ea980r Digital Anemometer User Manual

OPERATING INSTRUCTIONS

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual

473 Dew Point Hygrometer

Acceleration/Velocity/Displacement VIBRATION METER

The Fluke 66 and 68 Infrared Thermometers

RADIATION-METER TM-91/TM-92

473 Dew Point Hygrometer

Infrared Temperature Calibration 101 Using the right tool means better work and more productivity

Infrared Thermometer Model: and

63/66/68. Infrared Thermometers. Users Manual

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

INSTRUCTION MANUAL DTH Fax: (503)

Traceable Big-Digit Type-K Thermometer Big digits are readable from 15 feet away. For additional Type-K probes, see page 41.

THERMOFOCUS, a technological innovation

New! 2010 Model. Model No

Instruction Manual HI Refractometer for Invert Sugar Measurements

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

Instruction Manual HI Refractometer for Sodium Chloride Measurements

Infrared Hand-Held Thermometers

473-SHX Dew Point Mirror

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

VIBRATION METER. Instruction Manual.

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

L E A. Laser Elemental Analyzer

Elcometer 116C. Sling Hygrometer. Operating Instructions

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

IR-712 IR-712-EUR 12:1 Infrared Thermometer. IR-720 IR-720-EUR 20:1 Infrared Thermometer. IR-730 IR-730-EUR 30:1 Infrared Thermometer.

One-hand ph/temperature measuring instrument

GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL

HI Propylene Glycol Refractometer INSTRUCTION MANUAL

INFRARED TEMPERATURE SENSORS OPERATION AND SELECTION

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements

INSTRUCTION MANUAL Milwaukee Refractometer MA872 Refractometer for Fructose Measurements

Performance Measurements for Mechanical Air Handling Systems

1.25 LED DICE CATHODE

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

S150PTD-1A. Technical Data Sheet. 3.2x1.6mm, Phototransistor LED Surface Mount Chip LED. Features: Descriptions: Applications:

WS-7213U Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS. Figure 2. Figure 1

Data Sheet / Instructions. Dewpoint MeterO

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

Hadrons Desktop U.S. Atomic Clock & Weather Station

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

XR Analog Clock - Manual Setting Model Troubleshooting Guide

Instruction Manual HI Refractometer for Sucrose in Wine and Grape Products Measurements

2-7x32. Instruction manual

DIGITAL THERMOMETER WITH TRICOLOR LCD INSTRUCTION MANUAL

high energy state for the electron in the atom low energy state for the electron in the atom

Inside Wall Temperature Measurements of DSTs Using an Infrared Temperature Sensor

LITE-ON TECHNOLOGY CORPORATION

High Accuracy High Speed in Your Process

Infrared Thermometer Calibration A Complete Guide

WS-7038U Wireless 433 MHz Miniature Rain Monitor. Instruction Manual

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL

Dewpoint Meter Data Sheet / Instructions

WS-7211U Wireless 433 MHz Weather Station. Instruction Manual

15 E OWNER S MANUAL PIRATE SPYGLASS BRING EM NEAR PIRATE SPYGLASS TELESCOPE 5 W 30 W 60 W 45 W

Digital Dissolved Oxygen, Conductivity, TDS and ph Meter

Thermal anemometer. We measure it. testo 405. Flow velocity measuring instrument with temperature measurement

PiCUS Calliper Version 3

Transcription:

User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com InfraRed Thermometer with Laser Pointer MODEL IR400

Introduction Congratulations on your purchase of the Model IR400 IR Thermometer. The IR400 is capable of non-contact (infrared) temperature measurements at the touch of a button. The built-in laser pointer increases target accuracy while the backlit LCD and handy push-buttons combine for convenient, ergonomic operation. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Safety Use extreme caution when the laser pointer beam is on Do not point the beam toward anyone's eye or allow the beam to strike the eye from a reflective surface Do not use the laser near explosive gases or in other potentially explosive areas 2

Meter Description Meter Description 1. Laser pointer beam 2. IR Sensor 3. Measurement Trigger 4. Battery Compartment 5. LCD Display 6. Push-buttons 7. Handle Grip Display Description 1. Temperature scan in progress (trigger held) 2. Last reading held (trigger released) 3. Laser pointer ON 4. Emissivity (0.95 fixed) 5. Max or MIN value displayed 6. Temperature display 7. Low battery icon (replace battery) 8. Temperature units 3

Operating Instructions Basic IR Measurements 1. Hold the meter by its handle and point it toward the surface to be measured. 2. Pull and hold the trigger to turn the meter on and begin testing. The temperature reading, the flashing SCAN icon, the unit of measure, and = 0.95 will appear. 3. Release the Trigger and the reading will hold for approximately 10 seconds (HOLD will appear on the LCD) after which the meter will automatically shut off.. Laser Pointer 1. When the trigger is pressed, the laser pointer will turn on and identify the spot being measured. The icon on the display indicates that the pointer is on. 2. To turn the laser pointer off, press the button while scanning. Press the button again to turn the pointer back on. MAX - MIN The Max / Min feature provides a means to display the highest (MAX) or lowest (MIN) temperature measured during a scan. 1. While the trigger is pressed, press the MAX/MIN button. The MAX icon will appear and the maximum measured temperature will appear in the display. The displayed temperature will not change until a higher temperature is measured. 2. Press the MAX/MIN button again and the MIN icon will appear. The minimum temperature only will be displayed 3. Press the MAX/MIN button again to return to a real time display. Backlight When the meter is on, press the backlight button to turn the backlight on. Press the button again to turn the backlight off. Note: Constant use of the backlight feature will reduce battery life. Over-Range Indication If the temperature measurement exceeds the specified temperature range, the thermometer will display HI or LO in place of a temperature reading. Field of View The meter s field of view is 8:1. For example, if the meter is 8 inches from the target (spot), the diameter of the target must be at least 1 inch. Other distances are shown in the field of view diagram. Note that measurements should normally be made as close as possible to the device under test. The meter can measure from moderate distances but the measurement may be affected by external sources of light. In addition, the spot size may be so large that it encompasses surface areas not intended to be measured. 4

Battery Replacement When the battery symbol appears in the display, replace the meter s 9V battery. The battery compartment is located behind the panel that surrounds the meter s trigger. The panel can be pried open near the trigger and folded down as shown in the diagram. Replace the 9V battery and close the battery compartment cover. You, as the end user, are legally bound (EU Battery ordinance) to return all used batteries, disposal in the household garbage is prohibited! You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold! Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle IR Measurement Notes 1. The object under test should be larger than the spot (target) size calculated by the field of view diagram (printed on the side of the meter and in this guide). 2. Before measuring, be sure to clean surfaces that are covered with frost, oil, grime, etc. 3. If an object's surface is highly reflective, apply masking tape or flat black paint to the surface before measuring. Allow time for the paint or tape to adjust to the temperature of the surface it is covering. 4. Measurements can not be made through transparent surfaces such as glass. The surface temperature of the glass will be measured. 5. Steam, dust, smoke, etc. can obscure measurements. 6. The meter automatically compensates for deviations in ambient temperature. However, it can take up to 30 minutes for the meter to adjust to extremely wide changes. 7. To find a hot spot, aim the meter outside the area of interest then scan across (in an up and down motion) until the hot spot is located. Emissivity and IR Measurement Theory IR Thermometers measure the surface temperature of an object. The thermometer s optics sense emitted, reflected, and transmitted energy. The thermometer s electronics translate the information into a temperature reading which is then displayed on the LCD. The amount of IR energy emitted by an object is proportional to an object's temperature and its ability to emit energy. This ability is known as emissivity and is based upon the material of the object and its surface finish. Emissivity values range from 0.1 for a very reflective object to 1.00 for a flat black finish. For the Model IR400, the emissivity is set to 0.95 which is correct for 90% of typical IR measurement applications. 5

Specifications Display Response time Over range indication Polarity Emissivity Field of view Diode Laser Spectral response Auto power off 3-1/2 digit (1999count) LCD with backlighting Less than 1 second LCD will show HI / LO Automatic (no indication for positive polarity); Minus (-) sign for negative polarity. 0.95 fixed value D/S = Approx. 8:1 ratio (D = distance, S = spot) (Has 90% encircled energy at the focal point) Output <1mW, Wavelength 630~670nm, Class 2 (II) Laser product 6~14um Automatic shut off after 10 seconds, approx. Operating temperature 0 o C to 50 o C (32 o F to 122 o F) Storage temperature -20 o C to 60 o C (-4 o F to 140 o F) Relative humidity Power supply Weight 10%~90%RH operating, <80%RH storage 9V battery, NEDA 1604A or IEC 6LR61, or equivalent 180g (6.3oz) Dimensions 82 x 41.5 x 160mm (3.2 x 1.6 x 6.3 ) Range Resolution Accuracy -20C to -7 C -4F to 20 F 0.1 F/ C ±4 C (7.5 F) -7C to 343 C 20 to 630 F 0.1 F/ C Note: Accuracy is given at 18 C to 28 C (64 F to 82 F), less than 80%RH ±2% of reading + 2 C/4 F Copyright 2011 Extech Instruments Corporation (a FLIR company) All rights reserved including the right of reproduction in whole or in part in any form. 6 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com