Medical Military Facilities Templates. Pub Date: 1-Feb-16 ORCS1. Room. Operating Room, Cystoscopy (ORCS1) Description: Sheet.

Similar documents
Medical Military Facilities Templates. Pub Date: 1-Feb-16 TRPE1/TLTU1. Room Treatment, Proctoscopy (LGI) (TRPE1) NSF: Sheet.

COLONIAL ROMAN EMPIRE ROMAN EMPIRE COLONIAL ROMAN EMPIRE LOUISE PHILIPPE K» King Post Bed K» King Long Post Bed

DFCM APPROVAL STAMP THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL

Washers, Dryers & Misc.

Parallel Requirements of Construction Standards for Accessibility ANSI, UFAS and ADAAG

6. Common Laboratory Techniques

Urban Productive Safety Net Project (UPSNP) Procurement Plan

PHOS 15 LED PROJECTOR

Contents. Cubit 50 - Corner Workstations. Cubit Workstations. Complete Fitout Solutions

REPAIR PARTS. *CVC95 C'Flow Variable Speed Furnace ACVC950714CXBA ACVC950915DXBA GCVC950714CXBA GCVC950915DXBA

The scope of this SOP does not include radioactive, cryogenic, or biohazardous substances, or chemical spills pertaining to these materials.

Stock Movement 12/04/2017 5:13 PM. CRONUS International Pty. Ltd. 1 NAVDEV1. Page. External Document No.

Goodman Manufacturing Company, L.P San Felipe, Suite 500 Houston, TX 77056

Radiation protection in the endosuite and the importance of correct use of shields

3. Chemical Hygiene Plan: Laboratory Standard Operating Procedures. A. Laboratory Specific Information and Signatures

Bedroom. Available in a wide selection of finishes: wax or lacquered pine, painted pine and oiled or lacquered oak. The choice is yours.

Restoration Management Company

REPAIR PARTS. *CVC9 90% C'Flow 2-Stage Variable Speed Furnace

Goldwater Environmental Lab Guidelines and Policies

Claim Rep.: Don Draughon Business: (818) Estimator: Michael Miller Business: (760)

e v o l v i n g t h e c l a s s i c g r a c e o f a u t h e n t i c L o u i s P h i l i p p e s t y l i n g a n d b e a u t y

ADDENDUM NO. 2 JANUARY 15, 2019

Completion Match each each piece of equipment with its description. Please only put one number in the blank.

What is Albira and How Does the System Work and Why is it Differentiated Technology? Page 1

," Disposal. SOP#: PBSOPOO2 I Rev#: I 1. Title: Solvent and Chemical Storage, Transport, and Disposal Issue Date: SOP#: Revision #: 1

E-Invoice. Total. ibuild,inc. Subtotal. Sales Tax (0.0%) 3000 S Jamiaca Ct Suite 210 Aurora, CO Date 12/2/

PART # Manufacturer Item Description Cdn $ Cost US $ Cost Units

REPAIR PARTS. GMS95 Single Stage Upflow Furnace GMS950453BXAB GMS950703BXAB GMS950704CXAB GMS950904CXAB GMS951155DXAB.

WM 07 Conference, February 25 March 01, 2007, Tucson, AZ

REPAIR PARTS. GUP, GUPI, and GUPX "B" SERIES

GMVC 80% Variable Speed Communicating Furnace

Standard Operating Procedure

Visit any one of our 30 locations or visit us on line at

1. Electrostatic Lab [1]

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

REPAIR PARTS. AMH95 Amana brand 95% Hybrid Furnace AMH950453BXAA AMH950703BXAA AMH950704CXAA AMH950904CXAA AMH950905DXAA AMH951155DXAA

The LakeFront Collection

REPAIR PARTS. *MVC95 Variable Speed Furnace

Radioactive Waste Management Guide

data sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code

Urbaan Home The SC place bldg. 249 Ratchadaphisek Rd., DinDaeng, DinDaeng Bangkok, Tel:

Prepared By: R. W. Waggoner, Jr. Effective Date: August 18, 2008

ENERGY TO CARE COMING TOGETHER FOR OUR COMMUINITES

VALIDATION STUDY OF FTIR-BASED EMISSIONS MEASUREMENTS AT A MUNICIPAL WASTE COMBUSTOR

SECTION 3 PRODUCT COMPOSITION The test kit is composed of QuSTICK Strep A Reagent Stick, Reagent A, Reagent B, Positive Control, and Negative Control.

REPAIR PARTS. *MVM96 Variable Speed Furnace

Avon Oak Collection Bedroom, Dining and Occasional

NuOak Collection. Crafted from North American White Oak, this collection has a contemporary feel that blends style with traditional construction

KaVo Primus Treatment units. Onwards and upwards.

Protein Sequencer PPSQ-31A / 33A C297-E055B

REPAIR PARTS. A/GPG13 Package Gas Units

AMVC 80% Variable Speed Communicating Furnace

REPAIR PARTS. GMV9* Variable Speed Furnace

B Retrofit DOM

Pre-owned - 8 colour press FA-Line: FA-4* NEXT CLEANINKING #F4733 MODULAR 16" MULTI-SUBSTRATE FLEXO PRESS

Laboratory Safety Audit Checklist

cleanroom systems exhibition systems interior design systems software and service presentation systems

c e l e b r a t i n g t h e m a r r i a g e o f S h a k e r a n d C o n t e m p o r a r y d e s i g n

OHIO NORTHERN UNIVERSITY DEPARTMENT OF CHEMISTRY PREPARATIONS, TEACHING AND STOCKROOM ASSISTANT S GUIDE

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Urban Productive Safety Net Project (UPSNP) Procurement Plan

EXPERIMENT 6. Physical and Chemical Changes Part 2 INTRODUCTION

UNIVERSITY OF SOUTH CAROLINA RADIATION SAFETY POLICY NO. 7. USC NOVEMBER 1985 (Revised May 2011) Preparation and Disposal of Radioactive Waste

Cabinets G " integrated in upright Handle strip in side panel Easy solution for shortened doors

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

ORIGINAL ARTICLE On-Line Arterial P0 2 Measurements During Cardiopulmonary Bypass

Notice Basic Information Estimated Contract Value (USD) $35, (Not shown to suppliers) Reference Number Issuing Organization

AN EXPERIMENTAL STUDY ON SAND DUNE SEDIMENT TRANSPORT DUE TO TSUNAMI OVERWASH. K M Ahtesham Hossain Raju 1 and Shinji Sato 2

Soil Cation Analysis Using High-Performance Capillary Zone Electrophoresis Last Modified: October 20, 2006

Department of Environmental Health and Safety Laboratory Decommissioning and Clearance

Chemical Safety. Peter Yeung D.G. Manager. Safety Office The University of Hong Kong

Vehicle Information. Inspection Details. Inspection Date : Inspection ID : Inspector :

Claim Number: Policy Number: Type of Loss: Fire

Polarized Light. Nikki Truss. Abstract:

tablet casegoods timeless design refined materials sustainable options

Contents. Functional & modern - Fast. Specially for you. Built to last. Good Wood. Peace of mind - Guaranteed. 4 Cubit 50 with Jigsaw Storage Units

tablet casegoods timeless design refined materials sustainable options

LAB: Photosynthesis in Leaf Disks

Rapid Response Team, LLC

Kjeltec 2300 Analyzer Unit

The Clinical Chemistry System that offers more so you do less!

Lab 1 Uniform Motion - Graphing and Analyzing Motion

Blanket & Fluid Warming Cabinets

Western Electric A V a c u u m T u b e

Cookers. Always fresh. Always delicious.

Standards and Certifications. File # E37317, E65657 File # LR217017, LR217069

STUD & TRACK ROLL FORMING MACHINE

Objective: Science Classroom Laboratory Safety

Today s Weather 24 Hour Forecaster

Stirling engine with Cobra3

PAA-ANALYZERS PRINCIPLE OF OPERATION

Determination of Chloride using Potentiometry

Photosynthesis in Leaf Disks Teacher Preparation and Background Information

Book Automation for sectional doors up to 12 m 2 and overhead doors up to 11 m 2

ELOTANT Milcoside301V2

TAPS, WASTES & ACCESSORIES

Warehouse Supplies Catalog 2014

TAPS, WASTES & ACCESSORIES

Our goal i s to i mprove customers' productivity and quality.

Laboratory Measurements and Procedures

Transcription:

/Equipment Isometric 1 7

A4015 M7485 M7490 F2245 - CEILING MOUNTED EQUIPMENT PLAN Ceiling Mounted Equipment Plan 2 7

26' - 0" M8551 M3070 M3072 CT020 X4122 E0963 E0963 E0963 C0037 M3175 M8905 M8900 M8606 4 3 2 1 M8970 5 M8925 C0036 M8810 M8810 M8810 M4266 M8920 X3150 F0355 M4255 M8800 M7485 CE030 C03F0 M8825 M9110 X1200 M0765 A5075 CS040 C03P0 M8825 M8940 M0630 M0765 M0755 M0750 26' - 0" A5080 CT020 C03F0 M7490 M3073 F2010 A5108 M8840 M7845 M8830 M8830 M4250 M5030 M1801 A5108 M8900 M8905 E0130 F0280 M4815 M8495 M5512 M8910 F3050 M8555 M4816 - EQUIPMENT KEY NOTES 1 X-Ray Remote Control Unit 2 Lead Glass View Window per Note "1" Above. 3 Control panel for JSN X1200, Lithotripter, Extracorporeal. 4 Workstation for JSN X1200, Lithotripter, Extracorporeal. 5 Generator for JSN X1200, Lithotripter, Extracorporeal. Equipment Plan 3 7

A4015 - NORTH ELEVATION F3050 - SOUTH ELEVATION Interior Elevations 4 7

CE030 A5075 A5080 X3150 CS040 CT020 C03F0 C03P0 C03F0 - EAST ELEVATION M0765 M0750 M0755 - WEST ELEVATION NSF: 660 SF Interior Elevations 5 7

- EQUIPMENT SCHEDULE 1 2 JSN Nomenclature Qty LF Logistics Utilities AR NA AF VA 1 2 3 4 5 6 Column, Equipment Arm, Ceiling Mounted, Surgery 2 A A A A - F G - - - Cabinet, Control, Nitrogen 2 A A - - - B - - - - A4015 Clock, Elapsed Time, Electric 1 A A - - - A - - - D A5075 Dispenser, Soap, Disposable 1 C C C C - - - - - - A5080 Dispenser, Paper Towel, SS, Surface Mounted 1 A A A A - - - - - - Dispenser, Glove, Surgical/Examination, Wall Mntd 3 C C C C - - - - - - A5108 Waste Disposal Unit, Sharps 2 C C C C - - - - - - C03F0 Cabinet, U/C/B, 1 Shelf, 2 Half DR, 2 DO, 36x30x22 2 A A A A - - - - - - C03P0 Cabinet, Sink, U/C/B, 2 Door, 30" W 1 A A A A - - - - - - C0036 Rail, Apron, 4x30x1 2 A A A A - - - - - - C0037 Rail, Apron, 4x36x1 2 A A A A - - - - - - CE030 Cabinet, W/H, 2 SH, 2 GDO, Sloping Top, 38x30x13 1 A A A A - - - - - - CS040 Sink, SS, Single Compartment, 7.5x14x14 ID 1 A A A A D - - - - - CT020 Countertop, Solid Surface 1 8'-0" A A A A - - - - - - CT020 Countertop, Solid Surface 1 6'-0" A A A A - - - - - - E0130 Workstation, Documentation, OR, L-Shaped 1 C C - - - A - - - - E0963 Cart, General Storage, Mobile 3 C C C C - - - - - - F0280 Chair, Swivel, Low Back 1 C C - - - - - - - - F0355 Footstool, Straight 4 C C C C - - - - - - F2010 Basket, Wastepaper, Step-On 1 C C C C - - - - - - F2245 Camera, Video Surveillance, HD, IP Powered 1 C C - - - A - - - - F3050 Whiteboard, Dry Erase 1 A A - - - - - - - - Television, HDTV, Large Screen, 60" 2 C C C C - A - - - - M0630 Anesthesia Apparatus, 3 Gas 1 C C C C - A G C - - M0750 Flowmeter, Air, Connect w/50 PSI Supply 2 C C C C - - K - - - M0755 Flowmeter, Oxygen, Low Flow 2 C C C C - - A - - - M0765 Regulator, Vacuum 4 C C C C - - B - - - M1801 Computer, Microprocessing, w/flat Panel Monitor 1 C C C C - A - - - - M3070 Hamper, Linen, Mobile, w/lid 1 C C C C - - - - - - M3072 Frame, Infectious Waste Bag w/lid 1 C C C C - - - - - - M3073 Container, Biohazard Waste, Step-on, Fire Safe 1 C C C C - - - - - - M3175 Electrosurgical Unit, Dual Output 1 C C C C - A - - - - Equipment Schedule 6 7

- EQUIPMENT SCHEDULE 2 2 JSN Nomenclature Qty LF Logistics Utilities AR NA AF VA 1 2 3 4 5 6 M4250 Pump, Syringe, Infusion 1 C C - - - A - - - - M4255 Stand, IV, Adjustable 1 C C C C - - - - - - M4266 Pump, Volumetric, Infusion, Multiple Line 1 C C C C - A - - - - M4815 Hypo/Hyperthermia Unit, Automatic/Manual, Mobile 1 C C - - - A - - - - M4816 Warming Unit, Patient, Automatic Manual, Air 1 C C - - - A - - - - M5030 Stool, Surgeon, Revolving 1 C C C C - - - - - - M5512 Laser, Smoke Evacuator 1 C C - - - A - - - - M7485 Light, Surg, Ceiling Mtd, Dual, Equal Dia Heads 1 A A A A - F - - - - M7490 Light, Surg, Ceiling Mtd, Dual, Unequal Dia Heads 1 A A - - - F - - - - M7845 Monitor, Physiological, Bedside, 4 Channel 1 C C C C - A - - - D M8495 Laryngoscope, Video Glidescope 1 C C - - - - - - - - M8551 Light Source, Fiberoptic Headlamp 1 C C C C - A - - - - M8555 Insufflator, Automatic Controls 1 C C - - - A - E - - M8606 Endoscopy Cart, Fiberoptic, w/video Accessories 1 C C C C - A - E - - M8800 Cart, Anesthesia 1 C C C C - - - - - - M8810 Stand, Mayo 3 C C C C - - - - - - M8825 Table, Instrument/Dressing, CRS, approx. 36x20x34 2 C C C C - - - - - - M8830 Table, Instrument/Dressing, Mobile 2 C C - - - - - - - - M8840 Table, Back, Instrument/Dressing 1 C C - - - - - - - - M8900 Carriage, Pail, CRS, Without Pail 2 C C C C - - - - - - M8905 Pail, Utility, CRS, Without Carriage 2 C C C C - - - - - - M8910 Cart, Surgical Case 1 C C - - - - - - - - M8920 Stand, Basin, CRS, Mobile, Double 1 C C - - - - - - - - M8925 Stand, Basin, CRS, Mobile, Single 1 C C - - - - - - - - M8940 Stool, Anesthesia, With Back 1 C C C C - - - - - - M8970 Warmer, Blood, High Volume 1 C C C C - B - - - - M9110 Table, Operating, 5 or 6 Section, Trauma 1 C C - - - A - - - - X1200 Lithotripter, Extracorporeal 1 C C - - D F D - - B X3150 Rack, Apron/Gloves, Wall Mounted 1 A A A A - - - - - - X4122 Console, PACS, Remote View, w/two 3MP Monitors 1 C C - - - A - - - - NSF: 660 SF Equipment Schedule 7 7