Humidity Calibration Solutions

Similar documents
Humidity Calibration Solutions

The Fundamentals of Moisture Calibration

Overview Brochure Comprehensive range of instrumentation for the measurement of moisture and oxygen

MICHELL TECHNOLOGIES FOR MOISTURE. Calibration. General Principles & Theory, Equipment Considerations

CALIBRATION. Calibration. General Principles & Theory, Equipment Considerations. Copyright Caltech 2014

Chilled Mirror Hygrometry

Techniques for Fast Measurements of Low Dewpoint in Portable Hygrometers

Edgetech Instruments Inc.

Fundamentals of Moisture Measurement in Industrial Applications

473 Dew Point Hygrometer

REALIZATION OF HUMIDITY STANDARD FACILITY USING TWO-PRESSURE HUMIDITY GENERATOR AND HUMIDITY CHAMBER

Uncertainty in Humidity Measurement. Helping you make a better measurement.

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Understanding uncertainties associated with the 5128A RHapid-Cal Humidity Generator

Understanding the uncertainties associated with using the 5128A RHapid Cal portable humidity generator

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

Compact Orifice FlowMeter

473-SHX Dew Point Mirror

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

473 Dew Point Hygrometer

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Comparison of HCD5000 DewPoint Duo to Condumax II

Data Sheet / Instructions. Dewpoint MeterO

Automated multi-vapor gravimetric sorption analyzer for advanced research applications

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

Mercury Stack Monitor SM-4

The calibration of Hygrometer (LectureandTraining )

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

Dewpoint Meter Data Sheet / Instructions

DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS.

Response Characteristics of Dew Point Sensor with Aluminum Oxide by means of Correlation between Purging Rate and Tube Length

DVS Intrinsic Compact and Economical Dynamic Vapor Sorption System

CERTIFICATE OF CALIBRATION

Your partner in Science!

Heat stress index. Dewpoint. pressure. altitude

COPLEY S C I E N T I F I C. A multi-function aerosol system with aerosol generation, classification and monitoring capabilities for:

Quality assurance for sensors at the Deutscher Wetterdienst (DWD)

Meteorological Instruments for Solar Energy

Kestrel 4500 Pocket Weather Tracker

novaa 800 D Atomic Absorption Spectrometer

Science of Stability 2017

Prima PRO Process Mass Spectrometer

Evaluation of Vaisala HMP45D Humidity Probes

110 Lowell Rd Hudson, NH USA Tel:

STATUS OF THE WIGOS DEMONSTRATION PROJECTS

SSi Super Systems Inc.

Module 2. Measurement Systems. Version 2 EE IIT, Kharagpur 1

Performance Measurements for Mechanical Air Handling Systems

HFM 100 Series. Thermal Conductivity Meter for measurement of insulation and construction materials.

Complete Moisture Analysis

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

A calibration facility for automatic weather stations

Technology Document Version

integrating-sphere-construction-kits

ADI 2040 Process Analyzer

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

High Pressure Chemistry. Hydrogenation & Catalysis Tools.

TM360 TEMP-SEEKER PRECISION THERMO-PSYCHROMETER OPERATION MANUAL

EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser

Product Descriptions and Offerings

Wind Speed & Direction Sensors

A Case for Periodic Calibration or Verification of RTDs

Traceable UV-Vis Reference Materials

Manual Dew point scanner PCE-DPT 1

UV Hound Series. Dependable High Quality Air Monitoring. Accurate Readings Within Seconds. Portable UVDOAS Multi-gas Analyzers. Multi-Gas Capability

AWOS. Automated Weather Observing Systems COASTAL

Dielectric Analysis of Solid Insulations

Particle Analysis at the Touch of a Button. Litesizer series

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen

Lufft MARWIS-UMB Mobil Advanced Road Weather Information Sensor

MaxiMet. Compact Weather Stations. gillinstruments.com

Baltimore Aircoil Company w w w. B a l t i m o r e A i r c o i l. c o m

Operator's Manual. optris BR 400. Calibration source

Ideal and powerful solution

REQUEST FOR QUOTATION (RFQ) FOR PROCUREMENT OF THERMO HYGROMETER -UNDP GLOBAL FUND

S8 TIGER Series 2 for ASTM D 6443

Complete Moisture Analysis

792A AC/DC Transfer Standard

CALIBRATION CERTIFICATE # 503

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CAP 437 Offshore Meteorological Observer Training

XEMIS NEXT GENERATION GRAVIMETRIC SORPTION ANALYZER

OXITEST Oxidation Test Reactor

Laird Thermal Systems Application Note. Precise Temperature Control for Medical Analytical, Diagnostic and Instrumentation Equipment

TA INSTRUMENTS. Vapor Sorption Analysis

1551A Ex/1552A Ex Intrinsically Safe Stik Thermometer. The new gold standard of industrial temperature calibration

Loadcell Calibration - Evaluation of Uncertainties

Display Calibrations and Uncertainties. Christine Wall National Physical Laboratory

Correction for Dry Bias in Vaisala Radiosonde RH Data

Process Analyzer and Sampling Systems

Infrared Thermometer Calibration A Complete Guide

Elcometer 116C. Sling Hygrometer. Operating Instructions

next generation Welcome to the Dispersion options Smarter particle sizing Your sample, expertly processed and prepared Particle size

Alumina & Pseudoboehmite & Molecular sieve

Introduction of RIC Tsukuba (Japan, RAII)

DESIGN, CONSTRUCTION AND EVALUATION OF A HUMIDITY GENERATOR

INNOVATION IN MAGNETICS DS0003/18. Mag-01H. Single Axis Fluxgate Magnetometer.

Defining quality standards for the analysis of solid samples

ALMA Weather Instrumentation Specification

Monitoring polymerization

Transcription:

Instruments Humidity Solutions www.michell.com

Instruments Humidity Solutions The Importance of Regular The reliable operation of a hygrometer and indeed any measuring instrument, can only be verified by periodic calibration against a dependable reference system. All hygrometers from Michell Instruments are delivered with a calibration certificate, but this alone will not guarantee the measurement performance throughout their life. Exposure to contaminants within the measurement of gas can cause measurement performance errors. To have confidence in the performance of a sensor it must be verified by periodic calibration. Michell Instruments Services Michell s UKAS (United Kingdom Accreditation Service) laboratory was established back in 1986 and was the first laboratory in the UK to be accredited for the dew point calibration of hygrometers. The capability of the laboratory has been maintained and developed over the years and Michell can now offer calibrations over the range 90 C to +90 C dew point with a best measurement capability of ±0.15 C dew point. In addition to this Michell can provide traceable calibrations to NIST (National Institute for s and Technology USA). s Each country will hold its own National for dew point and humidity. This may be a primary standard. Other calibration facilities will have reference instrumentation calibrated against the Primary and use this as their standard. In this approach a pyramid structure is generated. This structure gives confidence in the calibration process as traceability of calibrations is visible. Pyramid National Primary National Humidity @ NPL Background to Michell Instruments Michell Instruments is the international leader in the field of moisture and humidity measurement solutions. With over 30 years experience, Michell designs and manufactures a wide range of transmitters, instruments and system solutions capable of measuring trace moisture, humidity and dew point in a vast range of applications and industries ranging from compressed air, power generation, process, oil and gas, pharmaceutical and many more. With a fast growing international subsidiary and distribution network, the Michell Group provides solutions in moisture and humidity for the most demanding applications worldwide. Michell uses three key dew point measurement technologies in their products: Impedance method using a ceramic tile which delivers unrivalled speed of response and robustness. Chilled Mirror method which has been incorporated into advanced, precision instruments for industrial and laboratory use. Quartz crystal technology for a high precision, fast responding moisture measurement with self-calibration. Applications for calibration instruments Metrology Laboratories Meteorology Laboratories Laboratories Industrial Gas Producers Pharmaceutical Companies Humidity Sensor / Instrument Manufacturers... and many more Reference Working Measuring Instrument Secondary Accredited Traceable NPL Calibrated hygrometer S4000 Dew-point Generator DG-2 Hygrometer under test Easidew TX 2010 Michell Instruments

The Technology All the calibration systems and generators offered by Michell Instruments generate a gas that is suitable for the calibration of sensors by gas dilution. This method works by mixing different volumes of wet and dry gas then performing a check with a reference instrument to produce a gas of known humidity which can then be used to calibrate other humidity sensors. Both trace moisture and high-humidity gas can be produced using this method, with traceability of calibration achieved through the reference instrument. Particulate filter dry flow valve meter Reference Sensor Test Sensor Dry Gas In valve wet flow meter Saturator Instrumentation A comprehensive range of calibration systems for the calibration of trace moisture dew-point sensors to relative humidity sensors.the modular system of components enables systems to be designed to specific performance requirements and for the provision for everything from dry gas source to a transfer standard reference hygrometer. 2010 Michell Instruments

Instruments Systems Relative humidity or dew-point calibration systems Wide range of dew point and humidity can be generated Portable calibrators Self-contained calibrators Reference instruments with calibration traceable to National s Complete system design Components Dew-Point and RH Generators Manual, semi-automatic and PC controlled systems Comprehensive generation range from trace moisture to high humidity Excellent generation stability Can be supplied as a stand-alone or system components Reference Instrumentation Transfer standard reference hygrometers Fundamental chilled mirror measurement technology UKAS accredited calibration as standard Auxiliaries Mini-compressor package Pressure swing dryers Temperature chambers Sensor manifolds www.michell.com

Instruments Humidity Salts Fixed humidity Operating Temp. (ambient) 12, 33, 55, 75, 90%RH typically +21 C S503 Humidity calibrator HG1 Humidity calibrator Operating Temp. (ambient) 15 to 35 C Probe Points 7 Relative humidity (optional chilled mirror sensor) Operating Temp. 15 to 35 C Probe Points Designed to requirements Chilled mirror (optional) DG1, 2, 3, 4 Dew-Point Generator Range (manual and semi-automatic mixing) Operating Temp. DG1 DG2 DG3 DG4-40 to -75 to -40 to +18 to+24 C -75 to VDS Fully automated mixing VDS1 VDS2 VDS3-30 to -70 to -100 to Operating Temperature +18 to 24 C S904 Humidity and temperature calibrator OptiCal Humidity and temperature calibrator HG10 Humidity and temperature calibration systems Operating Temp. 10* to 50 C <0.2%RH Probe Points 5 Relative Humidity Operating Temp. 10* to 50 C <0.2%RH Probe Points 5 Chilled Mirror 1 to 95%RH Operating Temp. 10 to 80 C Configuration Designed to requirements Chilled Mirror DCS Dew-point calibration systems Configuration -100 to 20 Cdp Designed to requirements Chilled Mirror *Dependent on room ambient temperature www.michell.com

Michell Instruments operates in the following markets: Compressed Air Dryers Pharmaceutical s Laboratories and Metrology Semiconductors Natural Gas and Petrochemicals Industrial and Pure Gas Production Power Generation Other Product Ranges Dew-Point Transmitters Michell offers the widest range of dew-point sensors and transmitters on the market. From the industry standard Easidew 2-wire transmitter to the new, rugged Easidew PRO IS for hazardous areas, all are supplied with sensors traceable to national standards. Portable Instruments Michell s range of easy-to-operate portable instruments provides fast, accurate and stable measurement of dew point, relative humidity and moisture concentration. They are designed to satisfy the most demanding industrial conditions, and are unique in the market for giving repeatedly fast response to low dew points. Chilled Mirror Instruments Chilled Mirror is a fundamental measuring technology offering the user exceptionally accurate, reliable and repeatable measurements from trace moisture to high humidity. Michell offers a range of instruments based on a rugged sensor design that is equally suitable for installation in demanding process environments or for use as an accurate reference instrument in a National s Laboratory. Process Analysers Michell s range of analyzers is specifically designed to provide reliable online measurement in process applications such as dedicated water and hydrocarbon dew-point determination in natural gas. Three sensing technologies are used: the Ceramic Impedance sensor for measurements in gas and liquid phase; Quartz Crystal Microbalance for trace moisture in process gases and the Dark Spot Chilled Mirror for hydrocarbon dew point. Oxygen Analyzers Michell brings you the very latest technologies in oxygen measurement, designed to give years of reliable and accurate service in laboratory, process and flue gas applications. From instruments featuring a unique sealed reference zirconia sensor to a transmitter with the latest generation thermo-paramagnetic oxygen and thermal conductivity technology, all Michell oxygen analyzers are available in a range of different configurations. Relative Humidity Instruments Michell s own RH sensing technology provides excellent resolution, long term stability and speed of response. We offer a wide range of humidity and temperature measuring sensors and instruments, including relative humidity transmitters, humidity and temperature transmitters as well as handheld indicators. The humidity generator range includes the most stable humidity generator on the market. Michell Instruments 48 Lancaster Way Business Park, Ely, Cambridgeshire, CB6 3NW Tel: +44 1353 658000, Fax: +44 1353 658199, Email: uk.info@michell.com, Web: www.michell.com/uk Michell Instruments adopts a continuous development programme which sometimes necessitates specification changes without notice. Issue no: Instruments_97140_V2.1_UK_0210 2010 Michell Instruments