Research Article Noncontact Measurement for Radius of Curvature of Unpolished Lens

Similar documents
Review Article Nanoparticle Imaging with Polarization Interferometric Nonlinear Confocal Microscope

Designing a Computer Generated Hologram for Testing an Aspheric Surface

Research Article Visible Light Communication System Using Silicon Photocell for Energy Gathering and Data Receiving

LAB DEMONSTRATION OF INTERFEROMETRIC

Research Article Trial Application of Pulse-Field Magnetization to Magnetically Levitated Conveyor System

ARCUATE ARM PROFILOMETRY - TRACEABLE METROLOGY FOR LARGE MIRRORS

Einstein Classes, Unit No. 102, 103, Vardhman Ring Road Plaza, Vikas Puri Extn., Outer Ring Road New Delhi , Ph. : ,

Research Article Temperature Dependence of the Raman Frequency of an Internal Mode for SiO 2 -Moganite Close to the α-β Transition

Laser Optics-II. ME 677: Laser Material Processing Instructor: Ramesh Singh 1

Experiment 2: The Speed of Light

The Michelson Interferometer as a Device for Measuring the Wavelength of a Helium-Neon Laser

LASER TRAPPING MICRO-PROBE FOR NANO-CMM

Long- and short-term average intensity for multi-gaussian beam with a common axis in turbulence

Use of computer generated holograms for alignment of complex null correctors

Research Article Travel-Time Difference Extracting in Experimental Study of Rayleigh Wave Acoustoelastic Effect

Research Article Analytical Approach to Polarization Mode Dispersion in Linearly Spun Fiber with Birefringence

Research Article The Microphone Feedback Analogy for Chatter in Machining

Laser on-line Thickness Measurement Technology Based on Judgment and Wavelet De-noising

iprom Optical Interferometry Prof. Dr. -Ing. Rainer Tutsch Institut für Produktionsmesstechnik IPROM Technische Universität Braunschweig

Part 1 - Basic Interferometers for Optical Testing

Maximum likelihood estimation as a general method of combining. sub-aperture data for interferometric testing

MELOS 530 MEASURING EQUIPMENT FOR LENSES AND OPTICAL SYSTEMS. Combinations and Accessories. Indispensable for Quality Control of Optics

Astronomy 203 practice final examination

Development of surface metrology for the Giant Magellan Telescope primary mirror

Research Article Trapped-Mode Resonance Regime of Thin Microwave Electromagnetic Arrays with Two Concentric Rings in Unit Cell

International Journal of Scientific & Engineering Research, Volume 4, Issue 7, July ISSN

Research Article Partial Pole Placement in LMI Region

Research Article Coherent and Incoherent Scattering Cross Sections of Some Lead and Sodium Compounds at Angles below 10 for 241 Am Gamma Rays

Particle-Wave Duality and Which-Way Information

DEVELOPMENT OF MEASURING SYSTEM FOR STRESS BY MEANS OF IMAGE PLATE FOR LABORATORY X-RAY EXPERIMENT

Research Article Scalar Form Factor of the Pion in the Kroll-Lee-Zumino Field Theory

Metrology and Sensing

New concept of a 3D-probing system for micro-components

Distortion mapping correction in aspheric null testing

Offset Spheroidal Mirrors for Gaussian Beam Optics in ZEMAX

Research Article Wavelength Width Dependence of Cavity Temperature Distribution in Semiconductor Diode Laser

Lecture 2: Geometrical Optics 1. Spherical Waves. From Waves to Rays. Lenses. Chromatic Aberrations. Mirrors. Outline

AOL Spring Wavefront Sensing. Figure 1: Principle of operation of the Shack-Hartmann wavefront sensor

Zeeman Effect. Alex Povilus Physics 441- Fall 2003 December 20, 2003

TMT Metrology study for M2 and M3

Research Article Conformity Check of Thickness to the Crystal Plate λ/4(λ/2)

Introduction. Procedure. In this experiment, you'll use the interferometer to EQUIPMENT NEEDED: Lens 18mm FL. Component holder.

Research Article Forward and Reverse Movements of a Linear Positioning Stage Based on the Parasitic Motion Principle

Research Article Dynamic Carrying Capacity Analysis of Double-Row Four-Point Contact Ball Slewing Bearing

Research Article An Analysis of the Quality of Repeated Plate Load Tests Using the Harmony Search Algorithm

Core Concept. PowerPoint Lectures to accompany Physical Science, 8e. Chapter 7 Light. New Symbols for this Chapter 3/29/2011

Bureau International des Poids et Mesures. Rapport BIPM -89/1

,

Research Article Direct Evidence of Reduction of Cloud Water after Spreading Diatomite Particles in Stratus Clouds in Beijing, China

MEMS Metrology. Prof. Tianhong Cui ME 8254

1 N star coupler as a distributed fiber-optic strain sensor in a white-light interferometer

Research Article In-Pile 4 He Source for UCN Production at the ESS

The Experiment Study for Fatigue Strength of Bogie Frame of Beijing Subway Vehicle Under Overload Situation

Efficient sorting of orbital angular momentum states of light

Analysis and Calculation of Double Circular Arc Gear Meshing Impact Model

ROINN NA FISICE Department of Physics

Research Article Electromagnetic and Mechanical Characteristics Analysis of a Flat-Type Vertical-Gap Passive Magnetic Levitation Vibration Isolator

Research Article SGC Tests for Influence of Material Composition on Compaction Characteristic of Asphalt Mixtures

Homogeneity of optical glass

Research Article Metastability of an Extended Higgs Model

Robust and Miniaturized Interferometric Distance Sensor for In-Situ Turning Process Monitoring

UNIT-5 EM WAVES UNIT-6 RAY OPTICS

Interferometric determination of thermal expansion coefficient of piston/cylinder unit preliminary investigation

A Single-Beam, Ponderomotive-Optical Trap for Energetic Free Electrons

Engineering Metrology

Metrology and Sensing

Synopsis of Design of reflective projection lens with Zernike polynomials surfaces

Optical metrology for very large convex aspheres

PSD Analysis and Optimization of 2500hp Shale Gas Fracturing Truck Chassis Frame

Revisiting Fizeau s Observations: Spectral study of Na source using Newton s rings. Abstract

Measurements in Optics for Civil Engineers

Open Access Response of Quartz Crystal Microbalance Loaded with Single-drop Liquid in Gas Phase

Research Article A PLS-Based Weighted Artificial Neural Network Approach for Alpha Radioactivity Prediction inside Contaminated Pipes

Research Article Influence of the Parameterization in the Interval Solution of Elastic Beams

대기외란보정을위한단일연속변형거울에관한연구 A Study on a Single Continuous Deformable Mirror for Correction of Atmospheric Disturbance

Research Article Convex Polyhedron Method to Stability of Continuous Systems with Two Additive Time-Varying Delay Components

Light.notebook May 03, 2016

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

Polarization Shearing Interferometer (PSI) Based Wavefront Sensor for Adaptive Optics Application. A.K.Saxena and J.P.Lancelot

Research Article Two Mathematical Models for Generation of Crowned Tooth Surface

Recent progress in SR interferometer

Optical Shop Testing. Second Edition. Edited by DANIEL MALACARA. John Wiley & Sons, Inc. A Wiley-Interscience Publication

Particle size analysis -Chapter 3

Open Access Measuring Method for Diameter of Bearings Based on the Edge Detection Using Zernike Moment

VISUAL OPTICS LABORATORY POWER MEASUREMENTS. Prof.Dr.A.Necmeddin YAZICI. GAZİANTEP UNIVERSITY OPTİCAL and ACOUSTICAL ENGINEERING DEPARTMENT

Channel Optical Waveguides with Spatial Longitudinal Modulation of Their Parameters Induced in Photorefractive Lithium Niobate Samples

Metrology and Sensing

General Physics II Summer Session 2013 Review Ch - 16, 17, 18

Swamp Optics Tutorial. Pulse Compression

Experiment O-2. The Michelson Interferometer

Hints to help with selected problems. Draw a free-body diagram of the situation and then a component triangle. 1.5a

Physics 1302, Exam 3 Review

Physics 102: Lecture 16 Introduction to Mirrors

Efficient mode transformations of degenerate Laguerre Gaussian beams

Phase-Shift Estimation from Interferograms by Histogram of Phase Difference

CHAPTER 9 PERFORMANCE OF THE INTERFEROMETER

Coherence and width of spectral lines with Michelson interferometer

Research Article The Effect of Metal-Semiconductor Contact on the Transient Photovoltaic Characteristic of HgCdTe PV Detector

Visualization of polarization state and its application in Optics classroom teaching

Fringe shifts in multiple-beam Fizeau interferometry

Transcription:

International Optics, Article ID 3403, 7 pages http://dx.doi.org/10.1155/014/3403 Research Article Noncontact Measurement for Radius of Curvature of Unpolished Lens Haifeng Liang College of Photoelectrical Engineering, Xi an Technological University, Xi an 71003, China Correspondence should be addressed to Haifeng Liang; hfliang004@163.com Received 1 July 014; Accepted 15 September 014; Published 30 September 014 Academic Editor: Chenggen Quan Copyright 014 Haifeng Liang. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. A noncontact mathematical model to measure radius of curvature (ROC) of an unpolished spherical lens was proposed and also proved by experiments. This model gives ROC as a function of arcs radii and their separation distance, where the radii of the corresponding arcs could be acquired by taking coordinates of points on the arcs when two parallel lines of light project onto a lens surface. Our experiments demonstrated that the measured maximum relative error was 0.07% for a concave surface with a 38.19 mm ROC and 0.01% for a convex surface with a 97.75 mm ROC, which were all in agreement with those of theory prediction error. The suggested method presented a fast noncontact method for testing ROC of lens during coarse grinding and fine grinding. 1. Introduction There are two types of methods by which one can measure the radius of curvature (ROC) for a spherical lens in the optical manufacturing field, namely, contact and noncontact methods [1 5]. Of the contact type, the spherometer and photo-templates gauge are widely used. In order to acquire maximum or minimum sagittal depth when using the spherometer, the probe scans over the surface, which can damage any soft surface but also take long time. In addition, the test results would be easily affected by uncertainty in environmental conditions, such as temperature, mechanical vibration, and different operators. Using the photo-templates gauge, it is easy to damage the soft surfaces of lenses because of similar causes encountered using a spherometer. Furthermore, it is only effective for polished surfaces but ineffective for ground and finely ground surfaces as there are no distinct interference circles. For the noncontact type, there are also two instruments, namely, the autocollimating microscope [1] and the interferometer [3 5]. In using the former, the radius is equal to the distance between two positions when aligning the center and apex in the proper sequence, respectively [1]. During testing,itiseasytofindtheapexbutveryhardtolocatethe center owing to its uniqueness, thus taking an unduly long time to adjust the optical system. Also, polished surfaces are needed to form an autocollimating image during testing. As is well known, interferometers are rather expensive instruments requiring good environmental conditions to ensure accurate measurements. What is more, these two methods are also only effective for polished surfaces [ 5]because clear image needed to be obtained. It is necessary for testing the ROC of unpolished surface during coarse grinding and fine grinding to keep appropriate machining allowance for next procedure. As less work has been made to focus this field, a theoretical model of testing ROC was proposed and confirmed through experiments. The structure of this paper is as follows. Theory model was proposed in Section, including its error originates. In Section 3 of experiments and discussions, samples were carried out to prove the validation of this model including analyses of its antienvironment noise. Last, a conclusion, including main contribution, results, and limitation, and future work, was presented.. Theory Model A spherical surface of the optical lens could be recognized as part of a complete spherical surface. Hence, measuring the ROC of the lens surface can be obtained by finding the

International Optics corresponding radius of this sphere. The basic theory underpinning the proposed measurement is shown in Figure 1. Two circles are formed when two parallel planes intersect with sphere. The radii (r 1 and r )ofthesecirclescanbe obtained in noncontact method. If the distance (D) between these two planes was also priorly known, the ROC of the sphere (R) could be represented as Intersecting circle D Sphere center Intersecting circle 1 r 1 r R= (D +r 1 +r ) 4r 1 r 4D. (1) R In an actual measurement, only a segment of the circle canbeobserved(figure (a)) because only the front surface of lens is viewed at any given angle. We represent each of the viewed arcs, as drawn in Figure (b), in Cartesian coordinates, and denote the coordinates of the circle center by (x 0,y 0 ) and any point coordinate in the arc by (x i,y i ). According to the circle equation, we have the following formula: (x i x 0 ) +(y i y 0 ) =r, () where r is the radius of the arc. Using just the coordinates of three points on the arc, we can solve this equation to obtain the arc radius. To improve the accuracy, more points canbeusedtoformthesetofequations(see(3)) which can be solved using the least squares method. In actual testing, a laser triangulation sensor with a telecentric lens can be used to acquire the relative coordinates of all the points from the two arcs. After acquiring the circle radii and mutual separationbetweenarcs,wecanthencalculatetherocusing (1). Consider (x 1 x 0 ) +(y 1 y 0 ) =r, (x x 0 ) +(y y 0 ) =r,. (x n x 0 ) +(y n y 0 ) =r. In addition, we see from (1) that the measurement error originates mainly from the mutual distance (D) of the intersecting planes and fitting errors associated with the radii of the arcs. According to the theory of relative error propagation, the relative error (γ R )canbededucedfrom(1), shown in ln R γ R = r 1 Δr ln R 1 + r Δr ln R + D ΔD 1 = 1 R D (r 1D r 1 r +r3 1 ) Δr 1 1 + 1 R D (r D r r 1 +r3 ) Δr D 4 (r 1 + r ) D ((D +r1 +r ) 4r1 r ) ΔD. (3) (4) Measurement lens surface Figure 1: Schematic diagram of our method, where D is distance between two parallel planes, R is ROC of the sphere, and r 1 and r are the radii of these two intersecting circles, respectively. In general, Δr 1 =Δr =Δr;hence(4) is simplified to the following expression: ln R γ R = r 1 Δr ln R 1 + r Δr ln R + D ΔD = 1 Δr R D (r 1 +r )(D r 1 r )+r 3 1 +r3 D 4 (r 1 + r ) D ((D +r1 +r ) 4r1 r ) ΔD, where the error ΔD is attributed to the calibration error andadjustedtolessthan1μm. The error Δr is ascribed to measurement error of all the coordinates and is deduced from (). The result is r Δr = x Δx + r y Δy = x y Δx + Δy x +y x +y (x+y) = Δx Δx, x +y (where Δx = Δy) where Δx and Δy include all measurement error during determining the coordinates using the laser triangulation sensor, both having the same level of error. 3. Experiments and Discussions 3.1. Theory Discussions. To present a direct idea of the error, we introduce the absolute (repeat) error (Δx)of the latest D laser position sensor (LJK series produced by KEYENCE Co. Ltd.) into formula (6) toobtainδr; subsequently,γ R can be calculated by substituting Δr and ΔD into (5). The absolute (5) (6)

International Optics 3 D Sphere center Circle center r 1 r R Arc Arc 1 Sphere surface A point in the arc (a) (b) Figure : Measurement principle of a concave surface, where D is distance between two parallel planes, R is ROC of the sphere, and r 1 and r are the radii of these two intersecting circles, respectively. Relative error (%) 0.0 0.18 0.16 0.14 0.1 0.10 0.08 R D d 0.06 0.04 0.0 300 00 100 0 100 00 300 Distance of cutting planes center apart from the sphere center, d (mm) Sphere radius, R (mm) 10 100 30 00 50 300 with fixed D of 5 mm Figure 3: Profiles of the relative error forvarious ROC(R) values with distance(d) of the cutting planes center from the sphere center, where D is distance between two cutting planes. error for the LJK series sensor is less than 5 μm, and its measurement range reaches to 6 mm [6], which is adequate for testing ordinary optical lens. Curves giving the variation of the relative error with ROC of a lens over the range from 10 mm to 300 mm are shown in Figure 3, where the mutual distance (D) oftwosphereintersecting planes was set at 5 mm. For any tested ROC, the relative error represents a minimum value when the two sphere-intersecting planes are located in the middle of the lens. We also see that the minimum relative error decreases from0.065%to 0.005%with ROC (R). This is consistent with the empirical rule, namely, high relative error for small ROC and low relative error for large ROC. Next, the variation of the relative error with intersecting planemutualdistance(d) was also calculated with ROC set at 100 mm (see Figure 4). With D ranging from 5 mm to 0 mm, the minimum relative errors were all less than 0.0%, which is similar to that for a commercial spherometer [7]. Relative

4 International Optics 0.06 Relative error (%) 0.05 0.04 0.03 R D d 0.0 0.01 100 80 60 40 0 0 0 40 60 80 100 Distance of the middle of cutting planes apart from the sphere center, d (mm) Distance of two cutting planes, D (mm) 5 15 8 0 10 with fixed R of 100 mm Figure 4: Profiles of the relative error for different mutual distance (D) of cutting planes with the distance (d) of the cutting planes center from the sphere center, where R is ROC of the sphere. errors also showed a rapid increase as the intersecting planes move away from the center out to the edges. In the intermediate range within the lens, relative errors changed little with relative position and distance between the intersecting planes. This strongly implies that we can randomly set the position of these planes as well as their mutual distance (more than 5 mm) during testing. For most contact or noncontact measurement methods ofroc,suchasthosementionedabove,thelocationofthe test lens on the holder needs to be precisely aligned using equipment with accurate adjustments [1 5, 7]. Also, a vibrationless platform is needed for interferometry [3 5], profiler [7], and autocollimating microscopy [1]. These setups are inconvenient for large-scale and high speed measurements. In our work, the lens only needs to be placed within working distance of the double telecentric lens without accurate aligning. Figure 5 illustrates why position does not affect the error. With the tested lens nearer to the double telecentric lens, the projected arcs do not change because the incident line-structure lights are parallel to each other. Despite the fact that the object distance (between tested lens and double telecentric lens) becomes short, the magnification remains unchanged due to the inherent properties of the double telecentric lens. Thus, the tested lens only requires placing within the working range of the double telecentric lens, which makes the measurement procedure easier and measurement time shorter. Figure5(b) shows a diagram illustrating the effect of vibration on the measurement. In such conditions, the tested lens would show inclination with a slight angle to idea position, where two different arc radii to that previous one could be obtained. However, these two new arcs radii also obey measurement theory, and the difference before and after inclination is that the relative error would increase because these new arcs will not be located symmetrically with respect to the sphere center. Under most conditions, the additional relative error induced by vibration can be ignored because the tilt in angle is very small. 3.. Experiments. In our experiments, the double telecentric lens with magnification of 0.3, object distortion of 0.1%, and working distances ranging from 6 to 83 mm was used to acquire arc images. The projected optical axis was set perpendicular to the lens surface. The angle between projected axis and image axis was fixed at 30 degree. A semiconductor laser with output of line-structure light was applied for projecting onto the lens surface. The arcs, spaced mm apart and labeled (a) through (f) (Figure 6), were imaged by moving the tested lens. In considering the system setup and the calibration parameter, we can then obtain actual coordinates of points on the arcs. Substituting these actual coordinates into (3), we can obtain the radii of each arc using least square fitting with the circle formula. Table 1 lists examples of the results of the procedure. Given the arc radii and separation, the radius of sphere could be calculated according to (1);seecolumnheaded ROC in Table 1. The average for the spherical radii was 38.1794 mm,

International Optics 5 (a) (b) Figure 5: Effect of displacement due to (a) translation and (b) rotationon the ROC measurement during testing, where solid line represents the idea position and dotted line represents the actual position. (a) (b) (c) (d) (e) (f) Figure 6: Experimentally obtained image of arcs (part of cutting circles) with mm moving step of line-structure light. and the maximum repeatable relative error was only up to 0.0146%. Compared with the nominal value of 38.1900, the relative error was 0.07%. Furthermore, a convex surface with a nominal radius of 97.750 mm was also measured with the same procedure, and the results showed that the average spherical radius was 97.7707 mm, and maximum repeatable relative error was at most only 0.0036%. Compared with the nominal value, the relative error was 0.01%. This error is around one order of magnitudehigherthanthatofinterferometer[3 5], which is enough for site testing the ROC of lens during grinding. 4. Conclusions A model for noncontact measurement of the ROC was proposed and confirmed experimentally. This model gives ROC

6 International Optics Table 1: Measurement results for a plane-convex lens. Repeatability error Mutual distance (mm) Number of arcs Arc radius (mm) ROC (mm) Absolute (mm) Relative (%) a 38.0596 38.1804 0.0006 0.0017 a 3.0596 4 38.1801 0.0003 0.0008 a 3.0596 6 38.1800 0.000 0.0006 a 3.0596 8 38.1815 0.0017 0.0044 e 37.8590 a 3.0596 10 38.180 0.00 0.0060 38.180 0.0004 0.0011 4 38.180 0.0004 0.0011 6 38.1809 0.0011 0.0030 e 38.8590 8 38.1811 0.0013 0.0035 38.180 0.0004 0.0010 4 38.179 0.0006 0.0015 e 37.8590 6 38.1791 0.0007 0.0018 38.1743 0.0054 0.0146 e 37.8590 4 38.1751 0.0047 0.015 e 37.8590 38.1770 0.008 0.0075 Average ROC value (mm) 38.1794 Nominal ROC value (mm) 38.1900 Relative error (%) 0.07% as a function of arcs radii and their separation, where the radii of the corresponding arcs could be acquired by taking coordinates of points on the arcs obtained from two parallel lines of light projecting onto a lens surface. Also, experiments demonstrate that the measured maximum relative error is 0.07% for a concave surface with a 38.19 mm ROC and 0.01% for a convex surface with a 97.75 mm ROC, which were all in agreement with those of theory prediction error by our model. In addition, the proposed method showed better adaptability against vibration and placement accuracy that results from inherent properties of the measurement principle. Our proposed noncontact method could be applied for site-testing ROC in manufacturing factory. Future work needs to be made on the site experiments for its repeatability through obtaining low noise image of line-structure light and avoiding environment noise. Conflict of Interests The author declares that there is no conflict of interests regarding the publication of this paper. Acknowledgments Thanks are expressed to Dr. Liu Bingcai for experimental help and Dr. Wang Hongjun for discussions on the error propagation. References [1] N. Gardner and A. Davies, Self-calibration for microrefractive lens measurements, Optical Engineering, vol. 45, no. 3, Article ID 033603, 006.

International Optics 7 [] X.Cai,S.Chang,andC.Flueraru, Compactsystemformeasurement of optical surfaces having a large radius of curvature, Optical Engineering,vol.45,no.7,ArticleID073603,006. [3] D. G. Abdelsalam, B. J. Baek, and D. Kim, Curvature measurement using phase shifting in-line interferometry, single shot offaxis geometry and Zernike s polynomial fitting, Optik,vol.13, no. 5, pp. 4 47, 01. [4] D. G. Abdelsalam, M. S. Shaalan, M. M. Eloker, and D. Kim, Radius of curvature measurement of spherical smooth surfaces by multiple-beam interferometry in reflection, Optics and Lasers in Engineering,vol.48,no.6,pp.643 649,010. [5] Z. Yang, Z. Gao, Q. Yuan, J. Ye, and M. Li, Radius of curvature measurement based on wavefront difference method by the point diffraction interferometer, Optics and Lasers in Engineering,vol.56,pp.35 40,014. [6] KEYENCE Corporation of America, LJ-G Series: High-Accuracy D Laser Displacement Sensor, http://china.keyence.com/ products/measure/laserd/ljg/ljg.php. [7] Trioptics Gmbh, Super-Spherotronic for high-precision measurements, http://www.trioptics.com/pdfs/spherometers Prosp.%0web.pdf.

The Scientific World Journal Gravity Photonics Advances in Condensed Matter Physics Soft Matter Aerodynamics Fluids Submit your manuscripts at International International Optics Statistical Mechanics Thermodynamics Computational Methods in Physics Solid State Physics Astrophysics Physics Research International Advances in High Energy Physics International Superconductivity Atomic and Molecular Physics Biophysics Advances in Astronomy