Measurement of basic constants: length, weight and time

Similar documents
Moment and angular momentum

Mechanics. Centrifugal force Dynamics. What you need: Complete Equipment Set, Manual on CD-ROM included. What you can learn about

Mechanics Moment and angular momentum. Dynamics. What you need:

THE SCREW GAUGE. AIM: To learn to use a Screw Gauge and hence use it to find the dimensions of various regular materials given.

Moment of inertia and angular acceleration

Mechanics. Reversible pendulum Dynamics. What you need: Complete Equipment Set, Manual on CD-ROM included. What you can learn about

Uniformly accelerated motion with an accelerating mass with the demonstration track and timer 4 4

Newton s 2nd Law with demonstration track and Cobra4

INTRODUCTION TO LABORATORY EXPERIMENT AND MEASUREMENT

Elementary charge and Millikan experiment Students worksheet

TESA MICROMASTER Electronic Micrometers with Digital Display

2 - Machining Fundamentals Measurement. Manufacturing Processes - 2, IE-352 Ahmed M El-Sherbeeny, PhD Spring-2015

Physical Measurements

Read the following BEFORE getting started:

Laboratory Manual Physics_1. Index of refraction for solids

Dr. Radhakrishnan A N Assistant Professor of Physics GPTC, Vechoochira

Winmeen Tnpsc Group 1 & 2 Study Materials

PAPER 2 THEORY QUESTIONS

Centripetal and centrifugal force

Conservation of momentum in a central elastic collision with the demonstration track and timer 4 4

DISCONTINUED PRECISION MEASURING FOWLER CALIPERS 1 - VERNIER CALIPERS 4 - ELECTRONIC CALIPERS

Moment of inertia and angular acceleration with Cobra 3

LAB 1 PRE-LAB. residuals (cm)

Appendix. Physical Constants. Micrometer

Heat capacity of gases

Free fall with an interface system

Mechanics. Determining the gravitational constant with the gravitation torsion balance after Cavendish. LEYBOLD Physics Leaflets P

Figure 1 Vernier Caliper (Kumpas)

Thermochemistry/Calorimetry LEC Heat capacity of gases. What you need: What you can learn about. Principle and tasks

LEP Newton s 2 nd Law / Air track with Cobra3. Related topics Linear motion, velocity, acceleration, conservation of energy.

Forced oscillation - Pohl s pendulum with measure Dynamics. Equipment TEP

Using a Simple Pendulum plot L T and L T 2 graphs, hence find the effective length of second's pendulum using appropriate graph.

Al-Saudia Virtual Academy Pakistan Online Tuition Online Tutor Pakistan

UNIQUE SCIENCE ACADEMY

E.G.S. PILLAY ENGINEERING COLLEGE Nagapattinam DEPARTMENT OF MECHANICAL ENGINEERING V SEMESTER REGULATION 2013 CHENNAI

Pre-AP Physics Review Problems

Wenzhou Tripod Instrument Manufacturing Co., Ltd.

Circular Motion and Centripetal Force

In which row is the size of the vector equal to the size of the scalar?

percent, since the ratio5/540 reduces to (rounded off) in decimal form.

For use with Comprehensive Secondary Physics

DIPLOMA IN ENGINEERING I YEAR

THE CONSERVATION OF ENERGY - PENDULUM -

Caution! Pay close attention to the special operation and safety instructions in the manual of the ultrasonic echoscope.

Operating Instructions Validation Tool Kit, KT2 For use with USP Apparatus #1 & #2

Candidate Number. General Certificate of Education Advanced Level Examination June 2010

IU1. Modul Universal Constants. Gravitational Acceleration

PHYS 3324 Lab Millikan Oil Drop Experiment: Demonstration of the Quantization of Charge

Making measurements. density the ratio of mass to volume for a substance

Second measurement. Measurement of speed of rotation and torque

Mechanics. Coupled Pendula with Cobra Dynamics. What you need:

Mass Mass is the amount of matter in an object. SI unit: kilogram (kg) 1 kg = 1000 g 1 g = 1000 mg. An adult brain: 1.3 ~1.4 kg

Metrology Prof. Dr Kanakuppi Sadashivappa Bapuji Institute of Engineering and Technology Davangere

LEP Coupled pendula

product manual H-3220A Benkelman Beam

OSCILLATIONS OF A SPRING-MASS SYSTEM AND A TORSIONAL PENDULUM

LINEAR AND ANGULAR MEASUREMENTS

Ballistic pendulum Operating Instructions Fig. 1: Ballistic pendulum SAFETY PRECAUTIONS

Density. Determine the density of a metal cylinder to three significant digits. Determine the density of a metal sphere to four significant digits.

No. Experiments Page No. 1 Use of Vernier Callipers 1. 2 Use of Micrometer screw gauge 5. 3 Use of Spherometer 9. 4 Parallelogram law of forces 12

Magnetic field of single coils/ Biot-Savart s law with Cobra4


Measurement of length (Item No.: P )

Force and Motion 20 N. Force: Net Force on 2 kg mass = N. Net Force on 3 kg mass = = N. Motion: Mass Accel. of 2 kg mass = = kg m/s 2.

Science TEKS Verification

PLANNING EXPERIMENT (SECTION B)

NCERT. To make a paper scale of given least count: (a) 0.2 cm and (b) 0.5 cm

Instruction Manual. Physics Laboratory MP-101. Applied Physics Department. Sardar Vallabhbhai National Institute of Technology, Surat

The Pendulum. Goals and Introduction

not to be republished NCERT DESCRIPTION OF THE MEASURING DEVICE EXPERIMENT AIM EXPERIMENTS

1. a) A flag waving in the breeze flaps once each s. What is the period and frequency of the flapping flag?

ICSE Board Class IX Physics Paper 3

LEP Stirling engine

ICSE Board Class IX Physics Paper 1

Measurement of Length

Thermal expansion of liquids

Coherence and width of spectral lines with Michelson interferometer

Acceleration Due to Gravity

External Micrometers. C-1

THE SCREW GAUGE. AIM: To learn to use a Screw Gauge and hence use it to find the dimensions of various regular materials given.

TEKS Physics, Beginning with School Year Correlation to CPO Science Link

Mechanics. Moment of inertia / Steiner s theorem Dynamics. What you need:

Magnetic field of single coils / Biot-Savart's law

SIMPLE PENDULUM AND PROPERTIES OF SIMPLE HARMONIC MOTION

Coulomb s law with Cobra3

KNIFE EDGE FLAT ROLLER

External Micrometers. C-1

Equation of state of ideal gases Students worksheet

1 General physics 1 Making measurements

Lab 8: Centripetal Acceleration

Instruction for use Plunger Probes M FB and M78-Plus

LEP Hall effect in p-germanium with Cobra3

PHYSICS LAB Experiment 9 Fall 2004 THE TORSION PENDULUM

1. MEASUREMENT. Measurement means the comparison of an unknown quantity with some known quantity.

SIR C.R.REDDY COLLEGE OF ENGINEERING ELURU

Lab 10 - Harmonic Motion and the Pendulum

E X P E R I M E N T 11

Laboratory Manual. Physics 166, 167, 168, 169. Lab manual, part 1 For PHY 166 and 168 students

Can you divide a millimeter into 20 equal parts? Essentially, a vernier does that exactly.

The measurements you make in the science laboratory, whether for time,

Transcription:

Measurement of basic constants: length, weight and time TEP Related topics Length, diameter, inside diameter thickness, curvature, vernier, weight resolution, time measurement. Principle Caliper gauges, micrometers and spherometers are used for the accurate measurement of lengths, thicknesses, diameters and curvatures. A mechanical balance is used for weight determinations, a decade counter is used for accurate time measurements. Measuring procedures, accuracy of measurement and reading accuracy are demonstrated. Equipment 1 Vernier caliper 03010-1 Micrometer 03012-1 Spherometer 03017-1 Light barrier 11207-20 1 Universal counter 13601-99 1 Precision balance, 2 pans, 5 g 44011-50 1 Set of precision weights,1 mg 2 g 44070-20 1 Iron column 03913-1 Iron wire, d = 1.0 mm, l = 10 m 06104-01 1 Aluminium foil, set of 4 sheets 06270-1 Glass plate, 1_85_1 mm 08203-1 Watch glass, dia. 80 mm 34572-1 Watch glass, dia. 1 mm 34574-1 Watch glass, dia. 125 mm 34575-1 Glass tubes, straight, l = 80 mm, 10 36701-65 1 Glass tube, d = 24/21 mm, l = 120 45158- mm 1 Cubes, set of 8 02214-1 Fish line, l = 1 m 02090-1 Steel ball with eyelet, d = 32 mm 02466-01 1 Rod with hook 02051-1 Support rod -PASS-, square, l = 630 02027-55 mm 1 Tripod base -PASS- 022-55 2 Right angle clamp -PASS- 02040-55 1 Measuring tape, l = 2 m 09936-2 Connecting cord, l = 5 mm, red 07361-01 2 Connecting cord, l = 5 mm, blue 07361-04 Fig. 1: Experimental set-up: Measurement of basic constants: length, weight, and time. www.phywe.com P21101 PHYWE Systeme GmbH & Co. KG All rights reserved 1

TEP Measurement of basic constants: length, weigth and time Tasks 1. Determination of the volume of tubes with the caliper gauge. 2. Determination of the thickness of wires, cubes and plates with the micrometer. 3. Determination of the thickness of plates and the radius of curvature of watch glasses with the spherometer. 4. Determination of the weight of different articles with highest possible accuracy with a manual precision balance. 5. Determination of the frequency of the pendulum. 6. Familarisation of the use of a universal counter in its multiple ways of use. Fig. 3: Reading off 28 on the graduated scale and 25 on the vernier scale gives 28.25 mm. Set-up and procedure Fig. 2: Vernier caliper. 1) Vernier caliper The caliper gauge (sliding gauge) is the best known measuring tool for rapid and relatively accurate measurement. Inside, outside and depth measurements can be made. The accuracy which can be achieved is proportional to the graduation of the vernier scale. The measuring faces which are relevant to the taking of reading may be seen in Fig. 2. When the jaws are closed, the vernier zero mark coincides with the zero mark on the scale of the rule. The name vernier is given to an addition to a gauge which enables the accuracy of measurement (reading accuracy) of the gauge to be increased by 10 to 50 times. The linear vernier is a small rule which slides along a scale. This rule is provided with a small scale which is divided into m equal divisions. The overall length of these m divisions is equal to m 1 on 2 PHYWE Systeme GmbH & Co. KG All rights reserved P21101

Measurement of basic constants: length, weight and time TEP the main scale. Fig. 2, shows 39 divisions extending from 28 mm to 67 mm on the graduated scale, whereas the vernier scale has 20 divisions (every second mark on the vernier has been omitted). The workpiece to be measured is placed between the measuring faces and the movable jaw blade is then pushed with moderate pressure up against the workpiece. When taking the reading the zero mark of the vernier is regarded as the decimal point which separates the whole numbers from the tenths. The full millimetres are read to the left of the zero mark on the main graduated scale and then, to the right of the zero mark, the vernier division mark which coincides with a division mark on the main scale is looked for. The vernier division mark indicates the tenths of a millimetre (Fig. 3). Fig. 5: Spherometer. Fig. 4: Micrometer, reading off 4.35 mm. 2) Micrometer With the micrometer (Fig. 4) (micrometer screw gauge), the accuracy of measurement can be increased by one order of magnitude. The workpiece to be measured is placed between the measuring faces, then the measuring spindle is brought up to the workpiece with the rapid drive (ratchet, thumb screw). When the rapid drive rotates idly, the pressure required for measurement has been reached and the value can be read off. The whole and half millimetres are read off on the scale barrel, the hundredths of millimetres on the micrometer collar. If the micrometer collar uncovers a half-millimetre, this must be added to the hundredths. 3) Spherometer More accurate relative measurements of parallel surfaces (plate thickness) and curvatures of spherical surfaces can be made with the spherometer.the spherometer is used for the measurements of the ra- www.phywe.com P21101 PHYWE Systeme GmbH & Co. KG All rights reserved 3

TEP Measurement of basic constants: length, weigth and time dius of the curvature of the spherical surfaces. In addition, the thickness of plates and the differences in level between surfaces can be found in a convenient manner. The device has a tripod with three measuring points which form an equilateral triangle. The probe of the dial gauge is located in the centre of this triangle. The distance between the tip of the probe and the plane defined by the three measuring points can be read on the dial gauge. The measurement accuracy is better than 10 2 mm. 4) Operation There are four threaded holes available on each leg of the tripod for the acceptance of the three measuring points. The points must all have the same separation from the central probe. In order to achieve a high accuracy of measurement, the points are screwed in positions as far outwards as possible. Consideration should be given to the limits set by the size of the surface to be investigated. The dial gauge latches into the tripod at two precisely defined positions. The upper position for the dial gauge is used for the measurement of curvature of convex surfaces; in this case the black figures on the gauge scale are used. If the dial gauge is pushed downwards in the tripod until it latches, then concave surfaces can be measured using the red figures. It is important to check the zero-point adjustment after matching the gauge position to the measurement task in hand. To adjust the zero point the spherometer is placed on the flat surface of the included glass plate and the scale on the dial gauge is rotated using the knurled ring. Vertical pressure on the spherometer should be avoided during the reading. Once this preparatory step has been completed, the device is placed on the surface whose radius is to be measured and the difference in height h is measured. One revolution of the large pointer corresponds to 1 mm (1 subdivision corresponds to 10 2 mm). The number of revolutions is given by the small pointer. The maximum measurement displacement is 10 mm. The radius of curvature R of a spherical surface is obtained from the measured difference in height h according to the equation where a is the distance of the measuring points from the centre of the system. The following figures are given for the four possible positions of the measuring points from the inside towards the outside, labelled with 1 to 4: Pos α/mm 1 15.0 2 25.0 3 32.5 4 40.0 5) Precision balance For didactical reasons we have not chosen a digital balance with high resolutions which is available in most laboratories. (You may use it for checking the results). Please follow the operating instructions to determine the weight of different samples with maximum accuracy. Note: Do not touch the precision weights with your fingers, always use the tweezers to avoid transfer of fat or dust to the weights. 6) Universal counter Also for didactical reasons, we have chosen a powerful 6 decade universal counter to learn the principles of time measurement. Please follow the detailed operating instructions to get familiar with the mul- 4 PHYWE Systeme GmbH & Co. KG All rights reserved P21101

Measurement of basic constants: length, weight and time TEP tiple possibilities of this equipment such as time, frequency and impulse measurement tool. In detail we describe the experiment of a pendulum. For the experimental setup refer to Fig. 1: Principle The oscillation of a thread pendulum is investigated using a light barrier. The frequency is assessed in different ways by means of the universal counter. Setup and Procedure - Determination of the period of oscillation by means of a universal counter used as a manual stopwatch. The fork light barrier is not required for this experimental setup. The FUNKTION button is pressed repeatedly until the operating mode TIME is activated. The pendulum is set to oscillate and the START button is pressed. The STOP button is pressed after about 10 complete oscillations. After this, the measured time is divided by the number of oscillations to obtain the period of oscillation T. - Determination of the thread pendulum oscillation frequency 6 decade counter, for higher frequencies the 4 decade can also be used. Select Analog for the type of signal with the MODE button. This mode ist suitable for periodic signals rather than TTL, which is use in case of square-wave signals. Connect the fork light barrier to Eingang/Input. Set to FREQ. operating mode with the FUNKTION button. Press the button repeatedly until the unit Hz appears on the display. Let the pendulum oscillate and press the START button. The display is now continuously updated. The oscillating half frequency, based on the half period, is displayed f = 1/(T/2) - Measurement of the period duration. Connect the light barrier to Eingang/Input and set PERIODE function mode. Start the pendulum and press the START button. The display, which is continuously updated, indicates the half period T/2. - Measurement of the complete period T. Connect the light barrier to the START/STOP input of the gate 1. Select for triggering condition press the TRIGGER button and AUTO for operating mode. After starting the pendulum and pressing the START buttons, the actual period T is continuously displayed. Press the button SET until LED control next to the inscription Digits lights up in order to vary the number of displayed digits by means of + and buttons. - Measurement of the half period T/2. Connect the light barrier to the START/STOP input (of the Gate 1). Select for triggering condition (The clock starts running as soon as a brightness controlled light barrier is first darkened, and it stops when the light barrier is darkened again. After starting the pendulum and pressing the START button, the half period T/2 is displayed. The accuracy of period (frequency) measurements is very high for periodic signals. For signals with a fluctuating period, impulse counting with a known gate time must be used (operating modes RPM, IMP and RATE). Results In the case of small amplitude oscillations of a thread pendulum (also known as physical pendulum), the measured oscillating period T is independent of the amplitude, it only depends on the length of the pendulum thread. www.phywe.com P21101 PHYWE Systeme GmbH & Co. KG All rights reserved 5

TEP Measurement of basic constants: length, weigth and time Evaluation For small oscillating amplitudes, an exact evaluation of the thread pendulum theory yields the following relation: where l = length of the pendulum thread g = 9.81 m/s 2, Earth s gravitational acceleration T= duration of period In the following example of measurement, the length of the thread is l = 0.125 m. This yields a duration of period T = 1.404 s, T/2 = 0.7021 s and an oscillating frequency 1/(T) = 0.71 Hz. These data are in good agreement with the measured values. Notice - If the fork light barrier is used for this experiment, the light beam should be interrupted by the fishing line and not by the ball. Press the Set button if the red control lamp on the housing of the light barrier is lit at the beginning of the experiment. - A measuring microphone (e.g. 03542.) can be connected to Eingang/Input instead of the fork light barrier. This allows to measure the duration of period and the frequency of acoustic phenomena (e.g. tuning fork oscillations). 6 PHYWE Systeme GmbH & Co. KG All rights reserved P21101