Fast, Effective XPS Point Analysis of Metal Components

Similar documents
for XPS surface analysis

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Introduction to Fourier Transform Infrared Spectroscopy

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

of mass spectrometry

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

MetWorks Metabolite Identification Software

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

Introduction to Fourier Transform Infrared Spectroscopy

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Complete Materials Deformulation Using TGA-IR

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

HILIC Method Development in a Few Simple Steps

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

QuantumMCA QuantumNaI QuantumGe QuantumGold

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Thermo Scientific GasBench II

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Screening Method for 30 Pesticides in Green Tea Extract Using Automated Online Sample Preparation with LC-MS/MS

High-Field Orbitrap Creating new possibilities

Key Words Nanoparticles, spicp-ms, ICP-MS, Qtegra ISDS Software, AF4-ICP-MS

Overcoming Interferences with the Thermo Scientific icap 7000 Plus Series ICP-OES

Microbial DNA qpcr Multi-Assay Kit Clostridium perfringens Pathogenicity

High-Resolution Accurate-Mass (HRAM) Phthalate Screening using Direct Analysis in Real Time (DART) Ambient Ionization

IN QUALITATIVE ANALYSIS,

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Trends in X-ray Microanalysis: Enabling Rapid Discovery One Pixel at a Time

Probabilistic Approach for Material Verification and Identification in Pharmaceutical Applications

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

HELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

3M Microbiology. 3M TM Petrifilm TM Plate Reader

Human C-reactive protein ELISA using Sword Peroxidase Reagents

Automated and accurate component detection using reference mass spectra

PHI. Scanning XPS Microprobe

Dr. Tim Nunney Thermo Fisher Scientific, East Grinstead, UK Dr. Nick Bulloss Thermo Fisher Scientific, Madison, WI, USA Dr. Harry Meyer III Oak Ridge

X-ray Photoelectron Spectroscopy/ Electron spectroscopy for chemical analysis (ESCA), By Francis Chindeka

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

OPTICAL PARTICLE SIZER MASS CALIBRATION METHOD

Optimization of temperature-sensitive assays using the Spark Te-Cool

A Platform to Identify Endogenous Metabolites Using a Novel High Performance Orbitrap MS and the mzcloud Library

An Evaluation of Various High-Resolution, Accurate-Mass Scan Modes for In Vitro Drug Discovery Screening

Ideal and powerful solution

AES Features in CasaXPS

Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS

The design of an integrated XPS/Raman spectroscopy instrument for co-incident analysis

Performance and Control of the Agilent Nano Indenter DCM

Information on the test material EDS-TM002 and the BAM software package EDX Spectrometer Test for determination of the spectrometer performance

Targeted protein quantification

Global 3D Machine Vision Market Report- Forecast till 2022

Keysight Technologies Instrumented Indentation Testing with the Keysight Nano Indenter G200. Application Note

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

FoodScreen Radiological Food Screening System

Monitoring Protein PEGylation with Ion Exchange Chromatography

protein interaction analysis bulletin 6300

Direct Analysis using Paper-Spray Mass Spectrometry: Method Development for the Rapid Screening of Drugs of Abuse for Forensic Toxicology

Environmental Series - Trace contaminant analysis in brine using a Thermo Scientific icap 6000 Series Duo ICP

Augmented Reality Market Research Report- Global Forecast till 2023

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science

Gamma Analyst Performance Characteristics (MDAs)

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

Theta Probe: A tool for characterizing ultra thin films and self assembled monolayers using parallel angle resolved XPS (ARXPS)

Battle the heat in your lab

Transcription:

Application Note: 52297 Fast, Effective XPS Point Analysis of Metal Components Chris Baily and Tim Nunney, Thermo Fisher Scientific, East Grinstead, West Sussex, UK Key Words K-Alpha Auto-Analysis Multi-Spectrum Point Analysis Surface Analysis Survey ID XPS The Thermo Scientific K-Alpha system was used to investigate a tarnished aluminum component. By using X-ray photoelectron spectroscopy (XPS), identification and quantification of chemical differences between optically distinct areas on the sample was possible. Introduction XPS sample analysis can be a very involved process, with operators requiring a high skill level to load samples, collect data and interpret the results. The K-Alpha surface analysis system enables researchers to utilize this powerful analytical technique via a unique combination of hardware design and intuitive software, without compromising information content or performance. The K-Alpha system is controlled by Thermo Scientific Avantage software, which controls all aspects of the sample analysis. Safe sample transfer protocols, and a point-and-shoot user interface via live camera views, are designed to make sample loading, navigation and analysis alignment quick and easy. When this user-friendly operation is coupled with powerful, integrated analytical tools such as Multispectrum insert, Survey ID, and full peak deconvolution, performing an XPS point analysis is quite easy to perform. In this application note we describe how the K-Alpha can be used to analyze a tarnished aluminum part to obtain chemical state information from different regions of the surface and understand the source of discoloration observed on the surface. Method The sample was mounted onto the 60 mm 60 mm sample platter by the use of two supplied spring clips (see Figure 1). Latex gloves were worn to prevent the sample or platter from being contaminated. The sample was then loaded into the fast entry load-lock, and the button pushed in the software to pump down and transfer the sample carrier into the analysis chamber. Sample transfer occurs automatically when the pressure in the load-lock reaches an acceptable level. Figure 1: Picture of the aluminum sample mounted on the K-Alpha sample block

When the sample is pumped down an image of the sample platter is automatically acquired and stored in the upper part of the optical view window to use for coarse navigation from sample to sample (see Figure 2). Once the samples are loaded into the analysis chamber, double-clicking on the platter image moves to a position of interest. A point analysis object can be inserted by first choosing Point from the drop-down menu; then, whilst holding down the control key on the keyboard, left clicking on the live optical view where you wish the centre of the analysis position to be (see Figure 3). This simultaneously inserts an X-ray object and a point object in the experiment tree (on the left of the screen) and on the optical view draws an ellipse, representing the size of the X-ray spot, at the analysis position (see Figure 4). The size of the X-ray spot defines the analysis area because the XPS signal is only obtained from the location on the sample that the X-ray is irradiated. The X-ray spot size is easily adjusted using the mouse-wheel to allow it to be tailored to the size of the feature being analyzed. Next, the multispectrum tool can be used to insert a survey spectrum (see Figure 5) and the experiment can be run. A survey spectrum is a full-range scan that can be used to identify the elements present at the surface, and to produce an elemental quantification. These spectra are usually lower resolution but have high count-rates to facilitate detection of weaker signals. It also enables detection of unexpected elements, and so are used to find all the elements that are present before collecting high-resolution, region spectra. Figure 2: Screenshot of the platter image acquisition, with inlay of the platter view camera configuration Figure 3: Screenshot of inserting a Point Figure 4: Screenshot after inserting a Point Figure 5: Screenshot of inserting a survey scan using the Multi-spectrum insert tool

Once collected, the survey spectrum is dragged into a processing view and the automated Survey ID tool is used to analyze the data using an elemental fingerprinting algorithm. The results of this, including the elemental quantification table, are shown in Figure 6. Based on the results of the survey spectrum analysis, region scans can be inserted using the Multi-spectrum insert tool by clicking on the required elements in the periodic table (see Figure 7 and Figure 8). This allows the user to setup the region scans without having to know the individual peak positions or any other acquisition parameters. After the experiment has completed, the region scans can be dragged into a processing view for quantification, either by adding or fitting peaks. Adding peaks is done by placing the range cursor at either end of the peak, clicking the add peak tool and it will integrate all the peak area between the data and the chosen background type (see Figure 9). Figure 6: Screenshot of survey scan after Survey ID Figure 7: Screenshot of using the multispectrum tool to insert region scans Figure 8: Screenshot after inserting region scans Figure 9: Screenshot of adding peaks to a spectrum

If a peak fit is required to deconvolve overlapping peaks from different chemical states then, once the range is selected, the peak fit tool can be used to add and fit peaks to the spectrum (see Figure 10). Once all the regions scans have been processed, the full chemical state quantification is shown in the peak table above the spectra (see Figure 11). This whole process can be repeated to give multiple point analyses in one experiment. Figure 12 shows the experiment setup to run three consecutive point analyses in the brown, grey and shiny parts of the sample. The software can also be configured to run this process automatically (Auto-Analysis mode), where the experiment is created on-the-fly by the instrument based on analysis of the survey spectrum, and data is exported to a Microsoft Word report. Figure 10: Screenshot of fitting peaks to a spectrum Figure 11: Screenshot of full chemical state quantification after all spectra have been analyzed Figure 12: Screenshot of the experiment tree setup to run multiple point analyses

Results Table 1 shows the comparison table of the chemical state quantification for all three analysis points. Name Shiny Area At. % Grey Area At. % Brown Area At. % Al2p Al 2 20.11 21.38 8.64 Si2p SiO 2 0.36 0.23 0.60 S2p sulfate 0.60 0.40 0.23 Cl2p organic 0.25 0.32 0.46 C1s C-C/C-H 17.78 9.51 11.88 C1s C-O 11.43 13.36 10.31 C1s C=.01 2.70 2.63 N1s organic 0.75 0.55 0.59 O1s 45.10 51.08 53.57 Fe2p Fe 2 0.27 0.18 10.14 Zn2p 3/2 ZnO 0.16 0.18 0.82 Na1s 0.18 0.12 0.14 Table 1: Full chemical state quantification for all three analysis points The quantification shows that the shiny and grey areas have very similar chemistries, with the only clear differences being the levels of carbon and oxygen. The brown area has over 10% of Fe 2 and a significant increase in the amount of ZnO as compared to the two other analysis points. As the iron oxide is on the surface, the signals from the elements beneath (most notably aluminum) are reduced. This attenuation of the substrate signal allows the thickness of the iron oxide layer to be calculated using another tool in the Avantage data system, based on a simple two-layer model. Using this tool, the iron oxide thickness is 1.5 nm. The identification of increased levels of zinc oxide and iron oxide enabled the analyst to determine the cause of the discoloration on the sample and hence the failure of the component. Summary The K-Alpha XPS system can be used to analyze points of interest on the surface of a sample quickly, easily and reliably by making use of the user-friendly experiment setup interface and the integrated data-processing tools. In addition to these offices, Thermo Fisher Scientific maintains a network of representative organizations throughout the world. Africa +27 11 822 4120 Australia +61 3 9757 4300 Austria Belgium +32 53 73 42 41 Canada +1 800 530 8447 China +86 10 8419 3588 Denmark +45 70 23 62 60 Europe-Other Finland/Norway / Sweden +46 8 556 468 00 France +33 1 60 92 48 00 Germany +49 6103 408 1014 India +91 22 6742 9434 Italy +39 02 950 591 Japan +81 45 453 9100 Latin America +1 561 688 8700 Middle East Netherlands +31 76 579 55 55 New Zealand +64 9 980 6700 Russia/CIS Spain +34 914 845 965 Switzerland +41 61 716 77 00 UK +44 1442 233555 USA +1 800 532 4752 www.thermoscientific.com 2012 Thermo Fisher Scientific Inc. All rights reserved. Microsoft and Microsoft Word are registered trademarks of Microsoft Corporation. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. VG Systems Ltd. Trading as Thermo Fisher Scientific, East Grinstead, UK is ISO Certified. AN52297_E 02/12M Part of Thermo Fisher Scientific