TSNAs in Tobacco Filler and Cigarette Smoke

Similar documents
Validation of TNCO, TSNAs, and PAHs

DETERMINATION OF NINE VOLATILE NITROSAMINES AND HYDROXY-NITROSAMINES IN CIGARETTE FILLER AND MAINSTREAM TOBACCO SMOKE

Method - Determination of aromatic amines in mainstream cigarette smoke

TR ACE ORGANIC. lgcstandards.com/foodandenvironment

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

British American Tobacco Group Research & Development. Method - Determination of phenols in mainstream cigarette smoke

Pesticide Standards. Sadat Nawaz. Pesticides Residues Analyst CSL, York, UK

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

British American Tobacco Group Research & Development. Method - Determination of ammonia in mainstream smoke

CORESTA Recommended Method No. 86

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009)

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

[ Care and Use Manual ]

Solid Phase Extraction Method Development Tips and Tricks

Application of multi-dimensional GC techniques to the analysis of cigarette smoke

CORESTA Recommended Method No. 83

Biological MS by Isotope Dilution. By: Cryst Bambo

Understanding the Uncertainty Associated with Analytical Results: Sources, Control and Interpretation of Results. Marc Paquet, Chemist M.Sc.

Strategies for the Analysis of Therapeutic Peptides in Biofluids by LC-MS/MS. Lee Goodwin

Smoke Analytes Sub-Group (SMA) Report 2018

Schedule. Draft Section of Lab Report Monday 6pm (Jan 27) Summary of Paper 2 Monday 2pm (Feb 3)

Examples of Method Validation Studies Conducted in Different Economies

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Polycyclic Aromatic Hydrocarbons in Water by GC/MS PBM

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

This method describes the identification of the following prohibited colorants in cosmetic products:

Technical Procedure for Blood Cannabinoid Liquid-Liquid Extraction (BCLLE) for Analysis by LC-MS/MS

CALIBRATION OF GC/MS METHOD AND VALIDATION OF THE MODIFIED SAMPLE PREPARATION FOR DETERMINATION OF POLYCYCLIC AROMATIC HYDROCARBONS

ENVIRONMENTAL analysis

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Technical Procedure for Solid Phase Extraction of THC and THC-COOH for GC-MS Analysis

QSM 5.1 FAQs. For a test with a recommended maximum holding time measured in hours, the holding time shall be tracked by the hour.

separation of the cleaned extract in subgroups of compounds (PCDDs, PCDFs, PCBs) depending on their polarity and geometry. The fractions can then be a

Technical Report. Determination of Nitrite and Nitrate in Smokeless Tobacco Products by Ion Chromatography and Continuous Flow Analysis

Sample Prep Options for GC users

Strategies for Analysis of Pyrethroid Insecticides in Complex Matrices

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Appendix II- Bioanalytical Method Development and Validation

Development of analytical methods for Catecholamines, Metanephrines and related metabolites in urine and plasma matrices

Kinetic Isotope Effects

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

Instructions for use. Chromogranin A ELISA TM E-9000

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration

GC/MS Application Note

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

Operating Instructions for Ammonium ISE Specifications

Introduction to Pharmaceutical Chemical Analysis

NATIONAL ASSOCIATION OF TESTING AUTHORITIES (NATA) REQUIREMENTS FOR ACCREDITATION OF ICP-MS TECHNIQUES

IDENTIFICATION AND DETERMINATION OF HYDROQUINONE IN COSMETIC PRODUCTS 2 14/11/17 ACM 003 BY TLC AND HPLC

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

GUIDELINES FOR THE ENVIRONMENTAL MONITORING AND IMPACT ASSESSMENT ASSOCIATED WITH SUBSEA OIL RELEASES AND DISPERSANT USE IN UK WATERS.

CHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS

Measurement Uncertainty: A practical guide to understanding what your results really mean.

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Quality Control Procedures for Graphite Furnace AAS using Avanta Software

Appendix A. Glossary of Definitions, Acronyms, Abbreviations and Symbols. March 1997

What is measurement uncertainty?

Xinyu LIU, Peter JOZA, Andrew MASTERS, Bill RICKERT

16 Malachite green 17 Leucomalachite green

Tyler Trent, Applications Sales Specialist, Teledyne Tekmar P a g e 1

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

A Fully Validated LC-MS/MS Method for Analysis of Trace Fluorotelomer Alcohols from Water

METHANOL REFERENCE SPECIFICATIONS

Characteristic of Calibration Curve Resulting from the Use of 2 H-analogs of the Analyte as Internal Standards--Methamphetamine Example

Perfluorinated Alkyl Acids (PFAAs): Practical Answers to Frequently Asked Questions

Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV*

Chapter 4: Verification of compendial methods

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEY WORDS. Simultaneous high-throughput screening of melamine (MEL) and cyanuric acid (CYA).

Practical Pharmaceutical Technology I USP Dissolution Method for PARACETAMOL 500 mg Tablets Section No. 6 Group D

Validation Report 18

Determination of Phenoxyacid Herbicides in Water by Solid Phase Extraction and LC-MS/MS Detection

Archived Content. This content was archived on June 24, 2013.

Chemistry 20 Final Review Solutions Checklist Knowledge Key Terms Solutions

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Glossary of Common Laboratory Terms

Soils, sludges and treated bio-waste Organic constituents - LAS by HPLC with fluorescence detection (LC-FLD) and mass selective detection (LC- MSD)

DISCLAIMER: This method:

Certificate of analysis Certified reference material code: CRM-00-GTX1&4

Detection of Mycotoxins in Corn Meal Extract Using Automated Online Sample Preparation with Liquid Chromatography-Tandem Mass Spectrometry

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

ADVANTAME (TENTATIVE)

LUMEFANTRINUM LUMEFANTRINE

Histamine Research ELISA

N-NITROSODIETHANOLAMINE (NDELA) IN COSMETICS

Transcription:

TSNAs in Tobacco Filler and Cigarette Smoke Chris Wright Carol Goss Magdalena Minnion British American Tobacco Group R&D UK US FDA Center for Tobacco Products Scientific Workshop 30-31 July 2013 1

A. Describe the different extraction steps used when analyzing TSNAs in tobacco filler, smokeless tobacco, and cigarette smoke particulate. Tobacco Filler and STPs Smoke Homogenisation (grinding, cryomilling) Hydration 1:1 (w/v) for in house method Sample pre-treatment Cigarette conditioning and smoking Labelled or unlabelled internal standards Extraction with methanol, ammonium acetate or dichloromethane Extraction by shaking or sonication Extraction Labelled or unlabelled internal standards Extraction with methanol, ammonium acetate or dichloromethane Extraction by shaking or sonication Filtration using PTFE/PVDF filter Reversed Phase SPE Cation exchange SPE Clean-up Filtration using PTFE filter SPE on alumina column LC-MS/MS GC-TEA Analytical determination LC-MS/MS GC-TEA BAT Group R&D procedures Procedures used by research partner laboratories 2

A. Describe the different extraction steps used when analyzing TSNAs in tobacco filler, smokeless tobacco, and cigarette smoke particulate. Extraction efficiency 120.0 100.0 Comparison of extraction efficiency of hydrated vs non-hydrated tobacco % recovery 80.0 60.0 40.0 20.0 Non hydrated Hydrated 0.0 NAB NAT NNK NNN Analyte Comparison of extraction technique and hydration on extraction efficiency 3R4F Tobacco NNN 3R4F Tobacco NNK 3.500 1.000 ug/g dry weight 3.000 2.500 2.000 1.500 1.000 0.500 0.000 30min shaking 60min shaking Sonicated Non hydrated Hydrated ug/g dry weight 0.800 0.600 0.400 0.200 0.000 30min shaking 60min shaking Sonicated Non hydrated Hydrated 3

B. Discuss the optimal solvents, extraction solutions, standards, and reference tobacco product(s) needed during the extraction of TSNAs from tobacco filler or, as applicable, a Cambridge filter pad. Tobacco and STPs Smoke Methanol after hydration (1:1 w/v, overnight) Ammonium acetate (100 mm) Dichloromethane Solvents Methanol Ammonium acetate (100 mm) Dichloromethane Add labelled IS Standards Add labelled IS Mechanical shaking (180 rpm, 60 min) Sonication Extraction solutions Mechanical shaking (200 rpm, 30 min) Sonication 3R4F tobacco Reference materials Control cigarettes 3R4F BAT Group R&D procedures Procedures used by research partner laboratories 4

C. Discuss the rationale for using isotopically labeled internal standards, instead of targeted surrogates or external standards for TSNAs. Provide the number of isotopically labeled internal standards needed to calculate the amount of TSNAs in a sample Stable isotope dilution (SID) is an inherently rugged technique of measurement by ratio. Requires mass selective detection, which gives added confidence in chemical identity. Mass-labelled analogues of 2 types are available 2 D for 1 H or 13 C for 12 C. Mass labelled analogues confirm the retention time of target substance Theory - a single labelled analogue per homologue group is acceptable Practice - a labelled analogue per target substance accounts more fully for matrix artefacts Matrix suppression and loss of sensitivity throughout the run means the use of external calibration is inappropriate D 4 -NNN NNN D 4 -NNK D 4 -NAT NNK NAT D 4 -NAB NAB Time--> 5

C. Discuss the rationale for using isotopically labeled internal standards, instead of targeted surrogates or external standards for TSNAs. Provide the number of isotopically labeled internal standards needed to calculate the amount of TSNAs in a sample. The effect of matrix suppression. Comparison of instrument response for same concentration of analytes in (a) solvent (yellow) and (b) cigarette smoke extract (blue) 1.40E+06 Internal Standard Absolute Peak Area 1.20E+06 1.00E+06 8.00E+05 6.00E+05 4.00E+05 2.00E+05 Standard 3R4F 0.00E+00 NAB NAT NNK NNN Analyte 6

C. Discuss the rationale for using isotopically labeled internal standards, instead of targeted surrogates or external standards for TSNAs. Provide the number of isotopically labeled internal standards needed to calculate the amount of TSNAs in a sample. Comparison of LC-MS/MS response for drift check standard injected after every 10 th sample 1.60E+06 Internal Standard Absolute Peak Area 1.40E+06 1.20E+06 1.00E+06 8.00E+05 6.00E+05 4.00E+05 2.00E+05 NAB NAT NNN NNK 0.00E+00 QC1 QC2 QC3 QC4 QC5 QC6 Isotopically labelled internal standards adjust automatically for drift in instrument sensitivity and/or matrix suppression 7

D. Discuss the challenges with isotopically labelled internal standards, including: (1) The commercial availability of internal standards or their analogues. D 4 deuterated TSNA standards are available from the following suppliers: - Kinesis (supplies from AccuStandard) - QMX (supplies from Dr. Ehrenstrofer-Schafers) - Toronto Research Chemicals Appropriate cost $7000 $12000 for 30mL of solution (~200 000 tests) Lead time approximately 3-4 weeks None of the mentioned suppliers have ISO Guide 34 accreditation for producing deuterated TSNAs The purity of the standards changes from batch to batch Problem with incomplete deuteration 8

D. Discuss the challenges with isotopically labelled internal standards, including: (1) The commercial availability of internal standards or their analogues. D 2 -NAT NAB D 4 -NAB D 2 -NAT can interfere with NAB detection at low concentrations. D 2 -NAT is a possible contaminant of D 4 -NAT 9

D. Discuss the challenges with isotopically labeled internal standards, including: (2) Individual v. mixture of internal standards, cost of internal standards Pre-mixed TSNA standards reduce effort needed for preparation and reduce risk of errors in preparation or differences in application between laboratories Cost of D4 mixed internal standard: $7000 $12000 for 30 ml Cost of native mixed standard stock: $4000 for 30 ml ISO guide 34 unlabelled standards are available Uncertainty of certified value: < 5% NAT, NNN, NNK <10% NAB (3) Deuterated v. 13C labeled internal standards. We are not aware of a commercial provider of 13 C-labelled TSNA standards 10

D. Discuss the challenges with isotopically labeled internal standards, including: (4) Concerns of proton exchange with deuterated labeled internal standards. There is no concern about deuterium-protium exchange as the method does not use strongly acidic or basic conditions MCX-SPE cation exchange cleanup does not affect recovery of deuterated TSNAs 11

E. Discuss the typical concentration ranges for total TSNAs, NNN, and NNK and any potential method adjustments to accommodate for different cigarette strengths and physical parameters. Range of data reported over 12 month period for in house method Standards = 0.09 90 ng/ml Tobacco Filler = 3.6 3600 ng/g Smoke = 3.6 3600 ng/cig Calibration standards (red) fully bracket samples (blue) Calibration range appropriate 12

F. Discuss the major sources of method variability, e.g., include sources from the smoking machine or regime, sample preparation, separation, and detection of different tobacco product types and strengths. Solvent choice influences recoveries and uncertainty of the method Aqueous extraction + SPE produces comparable results to methanol with hydration Individual Value 1.0 0.8 0.6 0.4 0.2 0.4 I-MR Chart of NNK (µg/g) in 3R4F by method (Tobacco Filler) Methanol Methanol + Hy dration A queous + SPE _ UC L=0.8208 X=0.7468 LC L=0.6727 1 7 13 19 25 31 37 43 49 55 61 Observation Methanol Methanol + Hy dration A queous + SPE NB Accuracy cannot be adequately assessed no certified reference materials / standards. Moving Range 0.3 0.2 0.1 0.0 1 7 13 19 25 31 37 Observation 43 49 1 55 61 UC L=0.0909 MR=0.0278 LC L=0 13

G. Discuss specific method challenges and limitations when testing NNN and NNK. Matrix suppression greater for NNN and NNK than NAT and NAB Clean up step in the method may be beneficial for smoke extracts Poor peak shape for NNN when extracted with aqueous buffer (CRM 75) CRM 75 In house method 14

H. Describe the differences in separation, detection, and limits of detection/quantitation when comparing liquid chromatography/mass spectrometry (LC-MS) and gas chromatography/thermal energy analyzer (GC-TEA) for TSNA analysis. Reporting limits for NNN, NNK (based on lowest calibration point) Tobacco Filler: LC-MS/MS 3.6 ng/g GC-TEA 200 ng/g Individual Value 0.8 0.7 0.6 0.5 I-MR Chart of NNK (µg/g) in 3R4F by Instrument (Tobacco Filler) 1 GC -TEA 5 9 13 17 21 Observation LC -MS/MS 25 29 33 UC L=0.8208 _ X=0.7468 LC L=0.6727 Cigarette Smoke: LC-MS/MS 3.6 ng/cig GC-TEA 10 ng/cig Moving Range 0.12 0.09 0.06 0.03 GC -TEA LC -MS/MS 1 UC L=0.0909 MR=0.0278 0.00 LC L=0 1 5 9 13 17 21 Observation 25 29 33 15

Main observations Internal Standards D 4 internal standards for each analyte compensate for matrix suppression, recovery; precision increases with number of IS Extraction Use either aqueous buffer or methanol after hydration to obtain highest extraction with greater precision for tobacco filler and STPs Matrix reduction Inclusion of SPE (HLB or MCX) reduces matrix artefacts and minimises suppression of instrument response for tobacco filler, STP and cigarette smoke samples Instrumentation LC-MS/MS achieves better sensitivity and greater selectivity Capacity of >500 tests per week on a single instrument 16