ME 304 CONTROL SYSTEMS Spring 2016 MIDTERM EXAMINATION II

Similar documents
ECEN 605 LINEAR SYSTEMS. Lecture 20 Characteristics of Feedback Control Systems II Feedback and Stability 1/27

AN INTRODUCTION TO THE CONTROL THEORY

Alireza Mousavi Brunel University

Controls Problems for Qualifying Exam - Spring 2014

Test 2 SOLUTIONS. ENGI 5821: Control Systems I. March 15, 2010

Time Response Analysis (Part II)

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

Root Locus. Motivation Sketching Root Locus Examples. School of Mechanical Engineering Purdue University. ME375 Root Locus - 1

Digital Control: Summary # 7

100 (s + 10) (s + 100) e 0.5s. s 100 (s + 10) (s + 100). G(s) =

Module 3F2: Systems and Control EXAMPLES PAPER 2 ROOT-LOCUS. Solutions

If you need more room, use the backs of the pages and indicate that you have done so.

Radar Dish. Armature controlled dc motor. Inside. θ r input. Outside. θ D output. θ m. Gearbox. Control Transmitter. Control. θ D.

Analysis and Design of Control Systems in the Time Domain

UNIVERSITY OF BOLTON SCHOOL OF ENGINEERING BENG (HONS) IN BIOMEDICAL ENGINEERING SEMESTER 1 EXAMINATION 2017/2018 ADVANCED BIOMECHATRONIC SYSTEMS

Control of Electromechanical Systems

MAE143 B - Linear Control - Spring 2018 Midterm, May 3rd

Automatic Control Systems (FCS) Lecture- 8 Steady State Error

MAS107 Control Theory Exam Solutions 2008

Control Systems. University Questions

(b) A unity feedback system is characterized by the transfer function. Design a suitable compensator to meet the following specifications:

Introduction to Root Locus. What is root locus?

Chapter 12. Feedback Control Characteristics of Feedback Systems

Control Systems. EC / EE / IN. For

EEE 184: Introduction to feedback systems

Laplace Transform Analysis of Signals and Systems

APPLICATIONS FOR ROBOTICS

Dr Ian R. Manchester Dr Ian R. Manchester AMME 3500 : Review

Software Engineering 3DX3. Slides 8: Root Locus Techniques

ECE317 : Feedback and Control

CHAPTER 7 STEADY-STATE RESPONSE ANALYSES

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Step input, ramp input, parabolic input and impulse input signals. 2. What is the initial slope of a step response of a first order system?

S I X SOLUTIONS TO CASE STUDIES CHALLENGES. Antenna Control: Stability Design via Gain K s s s+76.39K. T(s) =

Homework 7 - Solutions

Outline. Classical Control. Lecture 1

PID controllers. Laith Batarseh. PID controllers

LABORATORY INSTRUCTION MANUAL CONTROL SYSTEM I LAB EE 593

ROOT LOCUS. Consider the system. Root locus presents the poles of the closed-loop system when the gain K changes from 0 to. H(s) H ( s) = ( s)

ELECTRONICS & COMMUNICATIONS DEP. 3rd YEAR, 2010/2011 CONTROL ENGINEERING SHEET 5 Lead-Lag Compensation Techniques

Course roadmap. Step response for 2nd-order system. Step response for 2nd-order system

Part IB Paper 6: Information Engineering LINEAR SYSTEMS AND CONTROL. Glenn Vinnicombe HANDOUT 5. An Introduction to Feedback Control Systems

KINGS COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRONICS AND COMMUNICATION ENGINEERING

Raktim Bhattacharya. . AERO 422: Active Controls for Aerospace Vehicles. Basic Feedback Analysis & Design

CHAPTER # 9 ROOT LOCUS ANALYSES

ECE 388 Automatic Control

Review: stability; Routh Hurwitz criterion Today s topic: basic properties and benefits of feedback control

Automatic Control (TSRT15): Lecture 7

12.7 Steady State Error

6.1 Sketch the z-domain root locus and find the critical gain for the following systems K., the closed-loop characteristic equation is K + z 0.

Plan of the Lecture. Review: stability; Routh Hurwitz criterion Today s topic: basic properties and benefits of feedback control

Outline. Control systems. Lecture-4 Stability. V. Sankaranarayanan. V. Sankaranarayanan Control system

Systems Analysis and Control

I What is root locus. I System analysis via root locus. I How to plot root locus. Root locus (RL) I Uses the poles and zeros of the OL TF

CONTROL SYSTEMS LECTURE NOTES B.TECH (II YEAR II SEM) ( ) Prepared by: Mrs.P.ANITHA, Associate Professor Mr.V.KIRAN KUMAR, Assistant Professor

Module 07 Control Systems Design & Analysis via Root-Locus Method

Lecture 5: Frequency domain analysis: Nyquist, Bode Diagrams, second order systems, system types

Dr Ian R. Manchester

INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad ELECTRICAL AND ELECTRONICS ENGINEERING TUTORIAL QUESTION BANK

EE 422G - Signals and Systems Laboratory

CDS 101/110 Homework #7 Solution

Chapter 5 HW Solution

Chemical Process Dynamics and Control. Aisha Osman Mohamed Ahmed Department of Chemical Engineering Faculty of Engineering, Red Sea University

Performance of Feedback Control Systems

Systems Analysis and Control

Exercises for lectures 13 Design using frequency methods

Lecture 1 Root Locus

Root Locus Methods. The root locus procedure

Control Systems I. Lecture 7: Feedback and the Root Locus method. Readings: Jacopo Tani. Institute for Dynamic Systems and Control D-MAVT ETH Zürich

CHAPTER 1 Basic Concepts of Control System. CHAPTER 6 Hydraulic Control System

Outline. Classical Control. Lecture 5

Some special cases

Control System. Contents

Course Summary. The course cannot be summarized in one lecture.

Lecture 4 Classical Control Overview II. Dr. Radhakant Padhi Asst. Professor Dept. of Aerospace Engineering Indian Institute of Science - Bangalore

EECS C128/ ME C134 Final Thu. May 14, pm. Closed book. One page, 2 sides of formula sheets. No calculators.

Root locus Analysis. P.S. Gandhi Mechanical Engineering IIT Bombay. Acknowledgements: Mr Chaitanya, SYSCON 07

Goodwin, Graebe, Salgado, Prentice Hall Chapter 11. Chapter 11. Dealing with Constraints

ME 475/591 Control Systems Final Exam Fall '99

2.010 Fall 2000 Solution of Homework Assignment 8

Lecture 12. Upcoming labs: Final Exam on 12/21/2015 (Monday)10:30-12:30

Transient response via gain adjustment. Consider a unity feedback system, where G(s) = 2. The closed loop transfer function is. s 2 + 2ζωs + ω 2 n

PD, PI, PID Compensation. M. Sami Fadali Professor of Electrical Engineering University of Nevada

EE C128 / ME C134 Fall 2014 HW 6.2 Solutions. HW 6.2 Solutions

STABILITY OF CLOSED-LOOP CONTOL SYSTEMS

ECE 486 Control Systems

Delhi Noida Bhopal Hyderabad Jaipur Lucknow Indore Pune Bhubaneswar Kolkata Patna Web: Ph:

(a) Find the transfer function of the amplifier. Ans.: G(s) =

IC6501 CONTROL SYSTEMS

Control of Manufacturing Processes

Software Engineering/Mechatronics 3DX4. Slides 6: Stability

INTRODUCTION TO DIGITAL CONTROL

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

Chapter 7 : Root Locus Technique

1 (s + 3)(s + 2)(s + a) G(s) = C(s) = K P + K I

Chapter 7. Digital Control Systems

10ES-43 CONTROL SYSTEMS ( ECE A B&C Section) % of Portions covered Reference Cumulative Chapter. Topic to be covered. Part A

Control Systems I. Lecture 6: Poles and Zeros. Readings: Emilio Frazzoli. Institute for Dynamic Systems and Control D-MAVT ETH Zürich

Bangladesh University of Engineering and Technology. EEE 402: Control System I Laboratory

Lecture 5 Classical Control Overview III. Dr. Radhakant Padhi Asst. Professor Dept. of Aerospace Engineering Indian Institute of Science - Bangalore

Transcription:

ME 30 CONTROL SYSTEMS Spring 06 Course Instructors Dr. Tuna Balkan, Dr. Kıvanç Azgın, Dr. Ali Emre Turgut, Dr. Yiğit Yazıcıoğlu MIDTERM EXAMINATION II May, 06 Time Allowed: 00 minutes Closed Notes and Books All questions are equally weighted All necessary formulas are provided at the last page Student No. :.. Name : SURNAME :.. Signature :.. 3 Σ

PROBLEM The transfer function of a plant is given as: G p (s) s + 3s a) Determine the stability of the uncontrolled plant. b) Design a closed-loop control system with unity feedback using a P-controller with a gain of K>0. Draw the block diagram of the closed-loop system and determine the conditions on K to have a stable closed-loop system. c) What is the steady-state error of the closed-loop system in (b) to a unit step input? (Use K 5 for the P-controller.) d) Modify the closed-loop system in (b) so that you have a PI-controller illustrated below. Redraw the block diagram of the closed-loop system. What is the steady-state error of the new closedloop system to a unit step input? PI-controller + s 0 e) Comment on the steady-state errors you found in (c) and (d). Why are they different? Hint: Think about the type numbers of the closed-loop systems in (c) and (d). f) Bonus: Why did we use different gains in (c) and (d)? Solution: a) The characteristic polynomial of the uncontrolled system is equal to characteristic polynomial of the plant. D(s) s + 3s. Since there is a sign change in the coefficients of the characteristic polynomial, D(s) cannot pass the Hurwitz test which results in same conclusion with Routh criterion for second order systems, so the uncontrolled system is unstable. b) The block diagram of the closed-loop system with a PI-controller having a gain of K is: R(s) E(s) K R(s) s + 3s K + s + 3s When simplified the transfer equation becomes: R(s) K s + 3s + (K ) In order to have a stable system all the coefficients of the characteristic polynomial should have the same sign due to the Hurwitz test. Since the coefficients of s and s are positive K should also be positive. This imposes that: K > 0; K > ME30/6S/MT/Balkan,Azgın,Turgut,Yazıcıoğlu Page

c) Taking K 5 for the above system gives us the following open-loop transfer function (OLTF): G OL G H 5 G OL s + 3s If we put GG OOOO in the standard form, it becomes: G OL 5 s 3 s + K OL 5 Since there is no free s in the denominator the type number of the system is 0. The steady-state error (for unit step input) (e ss ) becomes. +K OL d) The block diagram of the new system with the PI-controller is: PI-controller R(s) E(s) The OLTF of the new closed-loop control system is: 0(s + ) G OL s(s + 3s ) If we put it into the standard form: G OL 0 (s + ) s( s 3 s + ) K OL 0 Since there is free s in the denominator of the OLTF, the type number of the system is. The steady-state error (for unit step input) becomes 0 in that case. e) The steady-state errors in (c) and (d) are different due to the addition of a PI-controller in (d). When we add a PI-controller in the closed-loop control system, we create add a free s in the denominator of the OLTF, hence increase the type number of the system by. f) We used different gains in (b) and (d) because the gain we used in (b) results in an unstable system in (d). Check the stability of the closed-loop system in (d) for K5 to clarify the explanation. ME30/6S/MT/Balkan,Azgın,Turgut,Yazıcıoğlu Page

PROBLEM Below is the model of a first order system with a commercially available PID controller in unity feedback configuration. Switches I, II and III can be independently arranged for different controller configurations where the transfer function of the system for all the switches are on is: G s Cs s K d + sk p + K i R s s + Kd + s+ Kp + Ki Note that switches have the effect of multiplication of the corresponding gain (Kp, Ki and Kd) by (when closed/on) and by 0 (when open/off). a) For the Kp values below together with Ki and Kd0, determine whether the system exhibits an oscillatory behavior to a step input or not? If oscillatory, is the output converging or not? i) Kp 5 ii) Kp 3 iii) Kp b) When switch I is on, switch II is off, and switch III is off, how does the speed of the step response get affected when Kp is increased? c) For positive Kp, Ki and Kd, list down all possible states of the switches so that the step response have i. zero initial jump and ii. nonzero initial jump at t0 +? Justify your answer. d) For only proportional (with positive Kp) and only integral (with positive Ki), what are the corresponding type number of the systems? Solution: a) For Ki and Kd0 G s Cs skp + Ki skp + R s as + s b+ K + K s + s + K + so the poles are ( p) i ( p) p p + K ± + K 3 p, 6± For Kp 5 the poles are p,,, so the response in not oscillatory Kp 3 the poles are p, ± i, so the response is oscillatory but convergent. Kp the poles are p, ± i, so the response is sustained oscillations. ME30/6S/MT/Balkan,Azgın,Turgut,Yazıcıoğlu Page 3

b) When switch I is on, switch II is off, and switch III is off, the transfer function becomes G s Cs Kp R s as b K a T. b+ K p + ( + p ), so the only pole is As Kp is increased, response becomes faster. b+ K p p and the time constant is a + x s Kd + sk 0 p + Ki s Kd + skp + Ki K y 0 lim s lim x d 0 x0 s s s a+ Kd + s b+ Kp + Ki s s a+ K d + s b+ Kp + K + i d c) so if switch III is on, no matter in which state other switches are, there will be a nonzero initial jump. If switch III is off, no matter in which state other switches are, there will be no initial jump. d) Cs K i G 0 s Kp skd R s + + s s + For KdKi0 (P-control) G ( s) For KpKd0 (I-control) G ( s) 0 0 Cs Kp, N0, so the type number is 0. R s s + Ki ( + ) Cs, N, so the type number is. R s s s ME30/6S/MT/Balkan,Azgın,Turgut,Yazıcıoğlu Page

PROBLEM 3 A dynamic system with the following feedback architecture will be controlled by selecting appropriate positive values for amplifier gain and sensor gain Kh. E(s) a) What will be the steady state error of the closed loop system to unit impulse input? b) Determine the gains and Kh that will make the closed loop system have the following unit step response.. Step Response. Time (seconds):.8 Amplitude:.6 Amplitude 0.8 0.6 Time (seconds):. Amplitude: Time (seconds):.0 Amplitude: 0.98 0. 0. 0 0 3 5 6 Time (seconds) Solution: a) Steady state error of the closed loop system to unit impulse input can be found by stability analysis of the closed loop system. Transfer function of the inner loop can be found as G i (s) s+ + K h s+ s+ s++k h s+ s+ K h +. The feedforward and open-loop transfer functions are G(s) G i (s) G(s)H(s) s s +( K h +)s since H(s). Closed loop transfer function is R(s) s + K h + s + s + K h + s s + K h + s s + K h + s+ s + K h + s s +( K h +)s+. ME30/6S/MT/Balkan,Azgın,Turgut,Yazıcıoğlu Page 5

The closed loop system will be stable for all positive values of and Kh therefore the steady state error of the closed loop system to unit impulse input is zero. Alternatively; Since E(s) e ss lim se(s) lim s +G(s)H(s) R(s) where R(s). + s + ( K h + )s lim s s + ( K h + )s + s + ( K h + )s b) The step response shown has the following transient response specifications: t r. s t p.8 s M p 6% t s.0 s (% criterion). These can be satisfied with the system parameters given as ω n rad s ζ 0.5 using for example t s ζω n and M p e lim s 3 + ( K h + )s s + ( K h + )s + 0. ζ π ζ Closed loop transfer function can be shown to be equivalent to an ideal second order system R(s) s + ( K h + )s + ω n 8. K h + ζω n K h 3 8. s + K h + s + ω n s + ζω n s + ω n. ME30/6S/MT/Balkan,Azgın,Turgut,Yazıcıoğlu Page 6