PRECONCENTRATION AND EXTRACTION OF COPPER(II) ON ACTIVATED CARBON USING ETHYL-2-QUINOLYL-β(p-CARBOXYPHENYL HYDRAZONE)DIOXO PROPIONATE

Similar documents
Determination of Some Heavy Metals in Real Samples by FAAS after Preconcentration on 4-Nitro-2-(2-nitrophenelazo)phenol

Spectrophotometric Evaluation of Stability Constants of Copper, Cobalt, Nickel and Zinc with 2-Thiobarbituric Acid in Aqueous Solution

GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRIC DETERMINATION OF CADMIUM AFTER SOLID-LIQUID EXTRACTION WITH DITHIZONE

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 8(2),

Mehrorang Ghaedi 1* and Ebrahim Niknam 1. (Received January 29, 2009; revised May 31, 2009)

Sodium Chloride - Analytical Standard

Removal of Heavy Metals Fe 3+, Cu 2+, Zn 2+, Pb 2+, Cr 3+ and Cd 2+ from Aqueous Solutions by Using Eichhornia Crassipes

Removal of Cu 2+, Cd 2+, Hg 2+, and Ag + from Industrial Wastewater by Using Thiol-Loaded Silica Gel

Analytica Chimica Acta 452 (2002) Received 20 September 2000; received in revised form 14 August 2001; accepted 26 September 2001

CHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS

DOUBLE DISPLACEMENT REACTIONS. Double your pleasure, double your fun

Sodium Chloride - Analytical Standard

Cu-Creatinine- Metol system

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

Reverse Flow Injection Analysis for Determination of Manganese(II) in Natural Water. Jintana Klamtet

Screening of Algae Material as a Filter for Heavy Metals in Drinking Water

CHAPTER 4 TYPES OF CHEMICAL REACTIONS & SOLUTION STOICHIOMETRY

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

Determination of Iron by Dispersive Liquid-Liquid Microextraction Procedure in Environmental Samples

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Solid Phase Extraction of Trace Cu(II), Mn(II), Pb(II) and Zn(II) in Water Samples with Pulverized Silica-salen(NEt 2 ) 2

Speciation of Cr (III) and Cr (VI) in Water Sample by Spectrophotometry with Cloud Point Extraction

Adsorption of Uranium by Chitin Phosphate and Chitosan Phosphate*

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

Describe in full the colour change at the end-point of this titration. ... (1)

The Copper Cycle. HCl(aq) H + (aq) + Cl (aq) HCl(aq) + H 2 O(l) H 3 O + (aq) + Cl (aq)

Conductivity of Electrolytes in Solution

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

Comparision of Langmuir and Freundlich Equilibriums in Cr, Cu and Ni Adsorption by Sargassum

Supporting Information

NET IONIC EQUATIONS. Electrolyte Behavior

School of Chemistry UNIVERSITY OF KWAZULU-NATAL, WESTVILLE CAMPUS JUNE 2009 EXAMINATION CHEM340: INSTRUMENTAL ANALYSIS.

Graphene oxide was synthesized from graphite using the MH (modified Hummer s method) 30 and

Column Preconcentration and Determination of Cobalt(II) Using Silica Gel Loaded with 1-Nitroso-2-naphthol

2-Hydroxy-4-n-propoxy-5-bromoacetophenone (HnPBAO) oxime as a gravimetric reagent for Ni(II) and Cu(II) and spectrophotometric study of the complexes

LEAD(II) AND COBALT(III) HEPTHYLDITHIOCARBAMATES AS NEW COFLOTATION REAGENTS FOR PRECONCENTRATION OF CADMIUM BEFORE ITS ETAAS DETERMINATION

white precipitate white precipitate, dissolves in excess of NaOH brown precipitate Identity of Q Identity of R Identity of S...

12 Nicarbazin Nicarbazin (4,4 -dinitro carbanilid (DNC) and 2-hydroxy-4,6-dimethyl pyrimidine (HDP))

Chemical Reactions: An Introduction

MAHESH TUTORIALS I.C.S.E.

Chemistry 20 Final Review Solutions Checklist Knowledge Key Terms Solutions

What Do You Think? Investigate GOALS

Part II. Cu(OH)2(s) CuO(s)

ICSE Board Class X Chemistry Board Paper Time: 1½ hrs Total Marks: 80

Chapter 7 Adsorption thermodynamics and recovery of uranium

Reactive fluorescent dye functionalized cotton fabric as a Magic Cloth for selective sensing and reversible separation of Cd 2+ in water

Lab #14: Electrochemical Cells

Recovery of Copper Renee Y. Becker Manatee Community College

Identification of Ions and Gases

Identification of ions and gases

The electrolysis of sodium chloride solution produces useful substances. covalent ionic non-metallic

SM/EB-20. A. Behjat 1, S. Dadfarnia 2, M. Parsaeian 3, A. M. Salmanzadeh 2, F. Anvari 3, and M. Kheirkhah 3.

Selective Transport of Lead(II) through a Bulk Liquid Membrane Using a Cooperative Carrier Composed of Benzylaza-12-crown-4 and Oleic Acid

Journal of Hazardous Materials 149 (2007)

MOF-76: From Luminescent Probe to Highly Efficient U VI Sorption Material

least reactive magnesium

Methods of purification

Revision Extra: Chemistry 3 Acids

Katarzyna Zielińska, Alexandre G. Chostenko, Stanisław Truszkowski

Separation of Toxic Metal Cations on Stannous Silicate layers in Micellar TLC

Identification of Ions and Gases

AP CHEMISTRY 2009 SCORING GUIDELINES

SOUTH AFRICAN NATIONAL STANDARD. Standard test methods for lead in water

BUSIA SUB-COUNTY JET 2016

PointH Standard Addition Method for Simultaneous Determination of Zinc (II) and Aluminum (III) Ions

NICKEL-63/59 IN WATER

IGCSE TEST_ (Ch. 2,3,4,5,6) Name... Date...

Properties of Compounds

Investigation of Nutrient Elements in Cucurbita pepo Using Atomic Absorption Spectrometry

ISEC The 21st International Solvent Extraction Conference

Flame atomic absorption spectrometric determination of trace amounts of Pb (II) after soild phase extraction using multiwalled carbon nanotube

5. SEPARATION OF MIXTURES, PURIFICATION OF SOLIDS Objectives

Section B: Some Essential Background Chemistry

Journal of Chemical and Pharmaceutical Research, 2014, 6(5): Research Article

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation

PRACTICAL QUESTIONS TEST TUBE REACTIONS 4&11 Questions. Dr Chris Clay

Unit 4a: Solution Stoichiometry Last revised: October 19, 2011 If you are not part of the solution you are the precipitate.

Draw one line from each solution to the ph value of the solution. Solution ph value of the solution

EXPERIMENTS. Testing products of combustion: Reducing Copper(III) Oxide to Copper. Page 4

DETERMINATION OF TRACE METALS IN MAHAWEEL RIVER SEDIMENTS BY ACID EXTRACTION

Experiment 6. Investigating Chemical Reactions

Extraction Behaviour of Cu 2+ Ions with Used Cooking Oil-Based Organic Solvent

ISSN : Department of Toxicology, School of Veterinary Medicine, University of Tehran, Tehran, (IRAN) 2

KENYA NATIONAL EXAMINATION COUNCIL REVISION MOCK EXAMS 2016 TOP NATIONAL SCHOOLS KAPSABET BOYS CHEMISTRY PAPER 1 TIME: 2 HOURS

SENSITIZED SPECTROPHOTOMETRIC DETERMINATION OF TRACE AMOUNTS OF COPPER(II) ION USING DIACETYL MONOOXIME IN SURFACTANT MEDIA

Form 4 Chapter 7: Acid and Bases

Help! I m Melting, wait...i m dissolving! Notes (Ch. 4)

Experiment 8 - Double Displacement Reactions

Environment Protection Engineering

1 A solution contains barium ions and silver ions and one type of anion. What could the anion be? chloride only. nitrate only.

Application of Selenium Speciation Analysis to Elucidate Limitations with Accepted Total Selenium Methods

Reactions (Chapter 4) Notes 2016.notebook. October 14, Chemical Reactions. Chapter 4 Notes. Oct 21 8:44 AM. Oct 22 10:14 AM

Removal of Cd (II) and Cr (VI) from Electroplating Wastewater by Coconut Shell

Journal of Chemical and Pharmaceutical Research, 2015, 7(4): Research Article

Part 01 - Notes: Reactions & Classification

In this activity, you will observe and predict products for some simple

Chemical Equilibria: Coordination Compounds

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

MC 17 C - 6 SECTION - I

St. John s College High School Mr. Trubic AP Midterm Review Packet 1

Transcription:

, 331-338. ISSN 1011-3924 Printed in Ethiopia 2008 Chemical Society of Ethiopia PRECONCENTRATION AND EXTRACTION OF COPPER(II) ON ACTIVATED CARBON USING ETHYL-2-QUINOLYL-β(p-CARBOXYPHENYL HYDRAZONE)DIOXO PROPIONATE Mehrorang Ghaedi 1*, Farshid Ahmadi 2, M.R. Baezat 3 and J. Safari 4 1 Chemistry Department, University of Yasouj, Yasouj 75914-353, Iran 2 Gachsaran Azad University, Gachsaran, Iran 3 Department of Chemistry, Fars Bioconversion and Environmental Research Institute, Shiraz, Iran 4 Chemistry Department, University of Kashan, Kashan 75914-353, Iran (Received January 12, 2008; revised April 17, 2008) ABSTRACT. Activated carbon modified method was used for the preconcentration and determination of copper content in real samples such as tap water, wastewater and a synthetic water sample by flame atomic absorption spectrometry. The copper(ii) was adsorbed quantitatively on activated carbon due to its complexation with ethyl- 2-quinolyl-β(p-carboxyphenyl hydrazone)dioxo propionate (EQCPDP). The adsorbed copper(ii) ion on solid phase was eluted quantitatively by using nitric acid. The important parameters such as ph, amount of carrier, flow rate, amount of activated carbon and type and concentration of eluting agent for obtaining maximum recovery were optimized. The method at optimum conditions gives linear concentration range of 0.05-1.0 µg ml -1 of copper(ii) with correlation coefficient of 0.9994 and the detection limit of 0.99 ng ml -1. The preconcentration leads to enrichment factor of 175 and break through volume of 1750 ml. The method has good tolerance limit of interfering ions and selectivity and it has been successfully applied for determination of copper content in real sample such as blood, wastewater and river sample. KEY WORDS: Copper(II), Solid phase extraction, Activated carbon, Flame atomic absorption spectrometry INTRODUCTION Considering biological research, the role of some trace and ultra-trace elements in the body is very rich and varied. Some of them are essential to life while others are toxic even at very low concentrations [1-3]. Copper has received considerable attention owing to its uses in metallurgy and chemical industries. Moreover, it is an essential constituent of about thirty enzymes and glycoproteins, is required for the synthesis of hemoglobin and for some biological processes and also promotes iron absorption from the gastrointestinal system. It is involved in the transport of iron from tissues into plasma, helps to maintain myelin in the nervous system, is important in the formation of bone and brain tissues and is necessary for other many important functions. Due to the presence of copper(ii) ion in environmental samples at low levels and matrix effects the low detection limit of copper with traditional flame atomic absorption spectroscopy (FAAS) requires its preconcentration in addition to separation from matrix elements. Preconcentration and separation can solve these problems and these difficulty can be overcome by caring out a separation step prior to analysis, and lead to simultaneously preconcentrate and separate the metal ions to be analyzed from the matrix [4]. The most widely used techniques for the separation and preconcentration of trace amount of copper are liquid and supported membrane transport [5, 6], solvent extraction [7, 8], co-extraction [9], liquid membrane extraction [10] and solid phase extraction [11, 12]. Among them, solid phase extraction due to advantages such as high efficiency, simplicity, rapidity, and low consumption of material has found increasing application in the enrichment of *Corresponding author. E-mail: m_ghaedi@mail.yu.ac.ir

332 Mehrorang Ghaedi et al. trace metal ions and elimination of matrix interference prior to FAAS analysis [13-23]. Use of various types of sorbents for separation and/or preconcentration of metal ions has been gaining popularity because of its high concentrating ability and simple operation. Among them activated carbon with high adsorption capacity has wide application due to its ability to adsorb organic compounds and organic metal complexes as non-polar or little polar substances in aqueous solution after converting them to corresponding metal chelates or precipitates or metal hydroxides. Metal chelate could provide higher selectivity and high enrichment factors for such a preconcentration and separation. The mechanism of metal sorption on activated carbon is still under investigation and their adsorption could be explained using Langmuir and Freundlich equations. It was assumed that the sorption is quantitative when the chelate contains systems of π-electrons in the molecule and when the centers for binding on carbon and those for the metal ions are spatially separated so that their orbital do not have a substantial influence [24]. The adsorption equilibrium studies have revealed that ph is the dominant parameter controlling the adsorption [25]. Therefore, using activated carbon as collector permits the preconcentration and separation of low levels of analytes in several matrices [26-29]. The purpose of this work is preconcentration and determination of copper(ii) ion content based on activated carbon modified with EQCPDP. Chemicals EXPERIMENTAL Acids and bases were of the highest purity available from Merck (Darmstadt, Germany) and were used as received. Doubly distilled deionized water was used throughout. Nitrate salts of copper, lead, cadmium, mercury, cobalt, nickel, zinc, magnesium, calcium, strontium, barium, silver, sodium and potassium (all from Merck) were of the highest purity available and used without any further purification. The ph adjustment was carried out by addition of dilute nitric acid or sodium hydroxide to the solution. Activated carbon (gas chromatographic grade, 40 60 mesh from Merck), were soaked in hydrochloric acid for 2 days, it was then washed with water and dried at 110 C for one day. The ligand ethyl-2-quinolyl-β(p-carboxyphenyl hydrazone)dioxo propionate (EQCPDP) was synthesized according the described procedure [30]. Pre-treatment of natural water samples Water samples were collected from Gachsaran, Iran. Before the analysis, the samples were filtered through a cellulose membrane filter (Millipore) of pore size 0.45 mm. The organic content of the water samples were oxidized in the presence of 2 ml of 1 % H 2 O 2 and addition of 5 ml of concentrated nitric acid. The samples were filtered through a filter paper and stored in polyethylene bottles. For the preconcentration procedure, 800 ml of water samples was heated until its volume was reduced to 250 ml. After adjustment of desired ph by the addition of appropriate amount of dilute sodium hydroxide or nitric acid, SPE experiment was carried out. The retained Cu(II) ions on modified activated carbon were eluted with 10 ml of 1 M HNO 3. The effluent was subjected to FAAS for evaluation of Cu(II) ions content. Apparatus The metal content determinations were carried out on a Shimadzu 680 AA atomic absorption spectrometer with a hallow cathode lamp and a deuterium background corrector at wavelength of 324.8 nm (copper resonance line) and the air-acetylene flame were adjusted according to standard recommendations. A Metrohm 691 ph/ion meter was used for the ph measurement.

Preconcentration and extraction of copper on activated carbon using EQCPDP 333 The amounts of ligand loaded on activated carbon were measured using UV-Vis 160 Shimadzu spectrophotometer. Extractions were performed with solid phase suspended in a tube while a piece of glass wool put in the end to inhibit loss of solid phase and sample were passed throughout for preconcentration and separation of the copper(ii) ion. Preparation of the solid phase Ligand loaded on activated carbon (AC) was prepared by dissolving 15 mg of the ligand EQCPDP in 0.005 M NaOH and adding to the 0.3 g of activated carbon. After 18 h, solutions were filtered through the filter paper and activated carbons were washed with distilled water until the filtrate was no longer alkaline. The solid phase columns were initially preconditioned with solution with desired ph. For the final optimum experiments the solid phase was prepared as follow: 15 mg EQCPDP per 300 mg of AC. Measurement of the amount of ligand loaded on the activated carbon (AC) A 0.3 g AC was placed in a 10 ml vial and 5 ml of 0.005 M NaOH containing weighed amount of ligand were added and shaken. After 18-20 h while shaking, a portion of the supernatant liquid was diluted to the appropriate volume and the absorbance of the solutions was measured at maximum wavelengths using a UV-Vis spectrophotometer. Results show that the ligand was adsorbed on activated carbon quantitatively. Preconcentration The ph of standard water solutions containing 0.01 1.5 µg ml -1 of copper was adjusted to the desired ph value, i.e. ph 5.7 ± 0.2 by adding appropriate amount of dilute sodium hydroxide or nitric acid to the sample solution. The sample was passed through the ligand loaded activated carbon column with flow rate lower than 5 ml min -1. The concentration of copper was determined in the final solutions by FAAS. Loading capacity To investigate the loading capacity, 100 ml of 5.0 µg ml -1 or various volume of 0.2 µg ml -1 of copper(ii) solution at ph 5.7 were passed through the solid phase columns containing 15 mg EQCPDP per 300 mg of AC. After loading and elution by nitric acid as stripping agent, effluent was sent into the FAAS to measure the copper content. RESULTS AND DISCUSSION The analytical parameters that are thought to affect the enrichment and measurement step in this procedure are ph, amount of EQCPDP, flow rate, amount of activated carbon and type and concentration of eluting agent and these parameters were optimized by using the univariate method for obtaining maximum recovery and efficiency for copper(ii) ion. The optimum values or range of a parameter were studied using a solution of 250 ml of 0.2 µg ml -1 copper(ii) ion. Effect of activated carbon amounts on extraction recovery In the adsorption step, an appropriate amount of activated carbon should be used in order to obtain quantitative retention of metal ions. On the other hand, an excess amount of the sorbent

334 Mehrorang Ghaedi et al. also prevents the quantitative elution of the retained metals by a small volume of eluent. For this reason, the effect of the amount of activated carbon and the eluent volume were examined. Therefore, the amount of activated carbon has an important role on recovery of extraction and must be optimized. The results show that sorption were quantitative with increasing amount of activated carbon until 300 mg and further addition lead to decrease in extraction efficiency, probably due to irreversible adsorption of metal ion (instead of its chelate) on activated carbon. So 300 mg of activated carbon were used for further studies. Effect of ph on recovery As is well known, ph value of the solution has significant influence on the overall performance of the retention of the copper(ii) ion on activated carbon. The effect of ph on the preconcentration of copper(ii) ion on AC loaded with EQCPDP was studied by determining 50 µg (250 ml of 0.2 µg ml -1 ) of copper(ii) ion which were preconcentrated in the ph range of 2.0-8.0 by introducing 15 mg of EQCPDP on the 0.3 g activated carbon. The results in Figure 1 show that optimum ph for maximum recovery of the Cu(II) ion are belonging to the ph from 5.0-6.5. Due to the presence of nitrogen atom in the ligand structures, which are weakly acid, at low ph they are not available to form chelate complexes and hydrogen ion compete with copper ion to these active sites, while in basic media due to hydroxide precipitation extraction efficiency would be reduced. 120 Cu(II) recovery (%) 100 80 60 40 Figure 1. Effect of ph on recovery of Cu(II) ion. 1 2 3 4 5 6 7 8 Influence of amounts of ligands on copper ion recovery To investigate the role of sorbent concentration on the recovery efficiency of Cu(II) ion, a series of preconcentration procedures under previously optimized conditions were carried out as following: 250 ml of 0.2 µg ml -1 of copper(ii) ions was passed through the column comprises of the various amount of EQCPDP loaded on constant value of activated carbon (0.3 g). The data are shown in Figure 2. The data show that the recovery of Cu(II) ion gradually increased with increasing concentration of ligands, reaching the maximum extraction efficiency at 15 mg of EQCPDP causes increase in recovery and further increase lead to decrease the efficiency, probably due to formation of soluble charged complexes. ph

Preconcentration and extraction of copper on activated carbon using EQCPDP 335 105 100 Cu(II) recovery 95 90 85 80 0 5 10 15 20 25 Amount of ligand Figure 2. Effect of amount of ligand on recovery of Cu(II). Flow rate has a great effect on the extraction efficiency, because lower flow rate lead to increasing residence and retention time of analyte in column, and so increasing interaction (complexation) between ions and sorbents. Therefore, different flow rate were examined and it was found that until 5 ml min -1 recovery is constant and after that gradually reduce. Therefore, flow rate of 5 ml min -1 was used for further studies. Effect of type and concentration of eluting agent on recovery The elution of a group of analytes could be sometimes troublesome owing to irreversible binding of some elements. An appropriate eluent for metal desorption was selected by taking into account the following considerations: (i) the eluent should desorb the metals or chelate complexes and (ii) should be suitable for the subsequent determination technique. Organic solvents and inorganic acids have been found to meet the requirements. For investigating the effect of eluting agent and its concentration on recovery, a set of experiments under previously established conditions were undertaken. Different acids with various concentrations were selected as eluting agents for quantitative desorption of retained copper(ii) ions. Results are given in Table 1 which show that when we used every eluting agent with concentration lower than 1.0 M except nitric acid recovery of copper(ii) ion is low, < 70 %, but, when nitric acid was used, recovery of the copper(ii) ion was increased. Hence, for further studies 10 ml of 1 M nitric acid were used for further studies for column modified by EQCPDP. Different volume of 1 M nitric acid was used as eluting agent. Results (Figure 3) show that with increasing nitric acid volume until 10 ml recovery increased and after that it remained constant. Table 1. Effect of type and concentration of eluent on recovery of Cu(II). Type and concentration of eluent Recovery of Cu(II) (%) 1.0 M HCl 35.9 1.0 M HNO 3 99.5 1.0 M H 2SO 4 67.3 0.2 M Histidine 34.8 0.4 M HNO 3 55.8 0.8 M HNO 3 89.3 1.5 M HNO 3 99.4 2.0 M HNO 3 99.6

336 Mehrorang Ghaedi et al. 120 100 Cu(II) recovery (%) 80 60 40 20 0 0 2 4 6 8 10 12 14 Volume of 1 M HNO 3 (ml) Figure 3. Effect of HNO 3 volume on Cu(II) ion recovery. Reproducibility The reproducibility of the method was evaluated at optimum condition by passing 250 ml solution of 0.2 µg ml -1 copper(ii) ion through the modified columns and the effluent was sent to FAAS for evaluating Cu(II) ions content. The experiment was repeated six times using the same sorbent. The reproducibility of modified columns based on EQCPDP is 99.9 ± 0.6 that indicate repeatable results. Interferences Preconcentration/separation procedures for trace elements in the high salt content samples can be strongly affected by the matrix constituents of the sample. The influences of some alkaline and alkaline-earth ions and transition metal ions on the copper ion recovery were investigated. The results are given in Table 2. The tolerance limit is defined as the ion concentration causing a relative error smaller than ± 5 % related to the preconcentration and determination of copper(ii) ion. Cu(II) ion was quantitatively recovered in the presence of large amounts of alkaline and alkaline-earth ions and some transition metal ions. The matrix ion contents in the eluent solutions were found to be significantly lower and suitable for atomic absorption spectrometric determinations. Table 2. Investigation of tolerance limit of interfering ion. Interfering ion [Interfering ion]/[cu(ii)] Recovery of Cu(II) (%) Ag + 1000 99.4 Hg 2+ 1000 98.9 Cd 2+ 1000 99.6 Ni 2+, Co 2+ 1000 98.9 Zn 2+ 1000 99.1 Fe 2+, Fe 3+ 1000 99.5 K + 1000 99.6 Ba 2+ 1000 99.6 Mg 2+ 1000 99.5 Pb 2+ 1000 98.8

Preconcentration and extraction of copper on activated carbon using EQCPDP 337 Calibration graphs and precisions The calibration curve was obtained by using 250 ml of 0.01-2.0 µg ml -1 copper(ii) solutions at ph = 5.8 ± 0.2 at the optimum conditions. The eluting solution was introduced to FAAS for evaluating copper(ii) ion content. The calibration curve was linear for copper(ii) ion in the range of 0.05-1.0 µg ml -1 with calibration curve equation of A = 0.25 C Cu(II) + 0.002. Relative standard deviations of measurements were found to be 0.6 % for 0.2 µg ml -1 of copper. Detection limits for the copper(ii) ion was found to be 0.99 ng ml -1. Accuracy and applications To ensure that the method is valid and has reasonable accuracy and precision, recovery of the copper(ii) ion in tap water, waste water and synthetic water samples were determined. The results are given in Table 3. Results, which obtained with reference standard addition method, express that reproducible and quantitative recovery for copper(ii) ion can be obtained. Table 3. Investigation of accuracy and precision of method for real samples analysis. Sample Added value Found value Waste water 0.0 0.800 0.169 ± 0.004 0.972 ± 0.002 Tap Water 0.0 0.200 0.08 ± 0.005 0. 283 ± 0.003 Synthetic mixture, Cu (1), Hg (4), Ni (4), Co (4), Pb (6), Zn (8), Fe(II) (5) 0.0 0.997 ± 0.002 Number in parenthesis is ion concentration (µg ml -1 ). Investigation of break through volume, enrichment factor and loading capacity For the investigation of enrichment factor and break through volume various volumes (ml) of 0.2 µg ml -1 of copper(ii) ion was passed through column and then the effluent was sent to FAAS for evaluating copper(ii) ion content. The results in Figure 4 show that up to 1750 ml of 0.2 µg ml -1 of copper(ii) ion adsorbed quantitatively on activated carbon and can be eluted by 10 ml of 1 M nitric acid leading to enrichment factors of 175. Figure 4. Investigation of loading capacity and enrichment factor.

338 Mehrorang Ghaedi et al. AKNOWLEDGEMENTS The authors gratefully acknowledge the support of this work by the University of Yasouj and Gachsaran Research Council. REFERENCES 1. Akhond, M.; Ghaedi, M.; Tashkhourian, J. Bull. Korean Chem. Soc. 2005, 26, 882. 2. Ghaedi, M.; Amini, M.K.; Rafi, A.; Gharaghani, S.; Shokrolahi, A. Ann. Chim. 2005, 95, 457. 3. Ghaedi, M.; Fathi, M.R.; Marahel, F.; Ahmadi, F. Feressen. Environm. Bull. 2005, 14, 1158. 4. Narin, I.; Soylak, M.; Latif, E.; Mehmat, D. Talanta 2000, 52, 1041. 5. Cleij, M.C.; Scrimin, P.; Tecilla, P.; Tonellato, U. J. Org. Chem. 1997, 62, 5592. 6. Safavi, A.; Rastegarzadeh, S. Talanta 1995, 42, 2039. 7. Kara, D.; Alkan, M. Microchem. J. 2002, 71, 29. 8. Sandhibigraha, S.A.; Bhaskara Sarma, P.V. R. Hydrometallurgy 1997, 45, 211. 9. Mendiguchi, C.; Moreno, C.; Vargas, M.G. Anal. Chim. Acta 2002, 460, 35. 10. Shamsipur, M.; Avanes, A.; Rofouei, M. K.; Sharghi, H.; Aghapour, G. Talanta 2001, 54, 863. 11. Ghaedi, M.; Ahmadi, F.; Karimi, H.; Gharaghani, S. Koran J. Chem. 2006, 51, 23. 12. Ghaedi, M.; Shokrollahi, A. Feressen. Environm. Bull. 2006, 15, 1714. 13. Narin, I.; Soylak, M.; Mehmat, D. Anal. Lett. 1997, 30, 2801. 14. Ghaedi, M.; Fathi, M.R.; Shokrollahi, A.; Shajarat, F. Anal. Lett. 2006, 39, 1171. 15. Jankowski, K.; Yao, J.; Kasiura, K.; Jackowska, A.; Sieradzka, A. Spectrochim. Acta Part B 2005, 60, 369. 16. Takara, E.A.; Pasini-Cabello, S.D.; Cerutti, S.; G asquez, J.A.; Martinez, L.D. J. Pharmaceut. Biomed. Analusis 2005, 39, 735. 17. Ghaedi, M.; Ahmadi, F.; Soylak, M. Ann. Chim. 2007, 97, 277. 18. Soylak, M. Anal. Lett. 2004, 37, 1203. 19. Soylak, M; Dogan, M. Trace Elements and Electrolyte 1996, 13, 130. 20. Narin, I; Soylak, M; Kayakirilmaz, K; Dogan, M. Anal. Lett. 2002, 35, 1437. 21. Saraymen, R.; Soylak, M. Intern. J. Chem. 1997, 8, 27. 22. Soylak, M.; Tüzen, M.; Narin, I.; Sarı, H. J. Food and Drug Analysis 2004, 12, 254. 23. Piperaki, E.; Berndt, H.; Jackwerth, E. Anal. Chim. Acta 1978, 100, 589. 24. Chen, J.P.; Lin, M. Carbon 2001, 39, 1491. 25. Cerutti, S.; Silva, M.F.; Gasquez, J.A.; Olsina, R.A.; Martinez, L.D. Spectrochim. Acta Part B 2003, 58, 43. 26. Ghaedi, M.; Shokrollahi, A.; Ahmadi, A. J. Hazard. Mater. 2007, 142, 272. 27. Cerutti, S.; Moyano, S.; Gasquez, J.A., Stripeikis, J.; Olsina, R.A.; Martinez, L.D. Spectrochim. Acta Part B 2003, 58, 2015. 28. Ghaedi, M.; Asadpour, E.; Vafaie, A. Bull. Chem. Soc. Jpn. 2006, 79, 432. 29. Daorattanachai, P.; Unob, F.; Imyim, A. Talanta 2005, 67, 59. 30. Safari, J.; Loghmani, H.; PhD Thesis, Esfahan University, Esfahan, Iran, 2001.