Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

Similar documents
Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

Thermo Scientific. Anion-Exchange Column

Dionex IonPac AS28-Fast-4µm column

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

columns IonPac AS22 Anion-Exchange Column

columns IonPac AS17-C Anion Exchange Column

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

anion-exchange column

columns IonPac AS18 Anion-Exchange Columns

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Determination of trace anions in concentrated hydrofluoric acid

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA

Determination of trace concentrations of oxyhalides and bromide in municipal and bottled waters

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Direct Determination of Small Organic Acids in Sea Water by IC-MS

Inline sample preparation for the determination of anions in sodium hydroxide

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

The power to increase productivity. Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities

Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm)

Utility of the Charge Detector in Ion Chromatography Applications

Ion Chromatography: Green Chemistry for a Green Environment. Ken Kirkbride Somerset, New Jersey October 12, 2011

Overcoming Challenging Matrices in Ion Chromatography

columns IonPac SCS 1 Silica Cation Separator

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

Determination of Adsorbable Organic Halogen in Wastewater

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column

Determination of silicate in high-purity water using ion chromatography and online sample preparation

suppressors Eluent Suppressors for Ion Chromatography

Determination of Inorganic Anions in Wastewater by Ion Chromatography

Development of the Thermo Scientific Dionex IonPac AS26 Column for Haloacetic Acid Analysis

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep

Determination of urea in ultrapure water by IC-MS/MS

The determination of trace anions in concentrated phosphoric acid

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography

The Determination of Trace Anions in Concentrated Phosphoric Acid

Thermo Scientific Dionex eluent suppressors for ion chromatography

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Determination of Trace Anions in Organic Solvents

Determination of Methylamine in Drug Products

The use of 2-D IC for the determination of Haloacetic Acids in Drinking Water

Sample Preparation for Ion Chromatography

Application Note 136

Expanded capabilities in ammonium and amine detection

Determination of trace anions in high-nitrate matrices by ion chromatography

Determination of trace anions in organic solvents using matrix elimination and preconcentration

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Application of Eluent Generation for Trace Anion Analysis of Borated Waters

Application Note 149. ) as shown in the following set of reactions: 9. BrO I + 3H + 3HOI + Br 3HOI + 3I + 3H + 3I 2 O 3I 2 + 3H 2 3I 3 + 3I

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

suppressors SRS -ULTRA Self-Regenerating Suppressor

Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography

Determination of trace anions in concentrated glycolic acid

Determination of Common Inorganic Anions in Environmental Waters Using a Hydroxide Selective Column

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

Monitoring Protein PEGylation with Ion Exchange Chromatography

Standard Operating Procedure for the Analysis of Chloride, Bromide and Sulfate in Fresh Waters by Ion Chromatography CCAL 50B.2

for IonPac AG11-HC IonPac AS11-HC

IC5000 Ion Chromatography System

Advances in Sample Preparation for Accelerated Solvent Extraction

DETERMINATION OF TOTAL HALOGEN CONTENT IN HALOGEN-FREE FLUXES BY INDUCTIVELY COUPLED PLASMA AND SOME LIMITATIONS OF ION CHROMATOGRAPHY

Determination of Monochloroacetic Acid in Carbocisteine

Determination of Trace Anions in Concentrated Glycolic Acid

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Determination of Trace Anions in Concentrated Hydrofluoric Acid

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Determinations of Heat Stable Amine Salts and Amines in Amine Scrubbing Solutions Using Suppressed Conductivity and Charge Detection

Analytical Methods to Qualify and Quantify PEG and PEGylated Biopharmaceuticals

Determination of trace anions in basic solutions by single pass AutoNeutralization and ion chromatography

Determination of Hexavalent Chromium in Drinking Water Using Ion Chromatography

Determination of Cr(VI) in Water, Waste Water, and Solid Waste Extracts

Data Pack. Ion Chromatography Methods. June 2009

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Simultaneous Determination of Pharmaceutical Peptides and Acetate Counterions by HPLC Using a Mixed-Mode Weak Anion-Exchange Column

Direct Determination of Cyanate in a Urea Solution and a Urea-Containing Protein Buffer

Determination of Organic Acids in Beer Samples Using a High-Pressure Ion Chromatography System

Transcription:

Thermo Scientific Dionex Ion Chromatography Solutions Global water safety bromate analysis in drinking water

Safe drinking water public health assurance As a vital limited resource required for survival, water fit for human consumption must be produced from natural sources such as ground and surface reservoirs. Since a clean water supply is the single most important determinant of public health, these ground and surface water reservoirs must undergo a purification process to ensure that all undesirable chemicals, biological organisms, and suspended solids are removed. As part of the purification process, water is often treated with ozone. Due to its high degree of oxidative reactivity, ozone effectively kills all microbial organisms that may be present and also serves to decolorize and deodorize the treated water. However, ozone reacts with bromide to form the carcinogenic compound bromate. The World Health Organization, European Commission, U.S. EPA, and Japanese Ministry of Health, Labor, and Welfare have established a regulatory maximum contaminant level (MCL) of 0 µg/l for bromate in municipal drinking waters treated with ozone for disinfection. Furthermore, the European Commission has an MCL of 3 µg/l in ozonated natural mineral waters and spring waters. As the innovator in ion chromatography (IC), Dionex (now part of Thermo Scientific) developed a variety of methods for bromate analysis in ozone-treated drinking water. These methods utilize different column chemistries, detectors, and system capabilities to provide drinking water suppliers with choices customizable for their analytical requirements. Dionex ICS-900 Dionex ICS-00 Dionex ICS-600 Dionex ICS-200 Dionex ICS-4000 Dionex ICS-5000 + 2

Regulatory leaders ion chromatography IC plays an important role in the analysis of ozone-treated drinking water. Over the past two decades, we ve led the effort to develop sensitive and robust IC methods that help water treatment facilities ensure that bromate levels remain below the regulatory limit before water is released for consumption. Bromate can be separated using different column chemistries and detected using a variety of detection techniques. Which one to use primarily depends on the sample and the detection limits required. When matrix conditions allow, suppressed conductivity detection is the easiest method to use. Otherwise, several strategies can be used to increase signal and deal with interfering anions by a combination of eluent, column, and detection methods. Thermo Scientific IC applications have been validated by the U.S. EPA and the International Standards Organization (ISO) for bromate determination of both low- and high-salt conditions. Our IC product line offers the flexibility, improved performance, and low overall cost-ofownership to meet your laboratory s analysis needs. Technique U.S. EPA Method ISO Method Application Note Drinking Water IC Suppressed Conductivity 300.0 B 506 67, 84 Low salt conditions IC Suppressed Conductivity 300. 506 67, 84 Low salt conditions IC Suppressed Conductivity with Postcolumn ODA 37.0 206 68 Tolerates higher salt conditions IC Suppressed Conductivity with Postcolumn Acidified KI 326. 206 7 Tolerates higher salt conditions 2D-IC Suppressed Conductivity 302.0 87 Tolerates higher salt conditions IC-ICP-MS 32.8 Tolerates higher salt conditions 3

EPA Methods 300.0 B/300. & ISO Method 506 IC with suppressed conductivity detection Since EPA Methods 300.0 and 300. were written over ten years ago, bromate determination using suppressed conductivity detection has been the preferred application. While carbonate/bicarbonate eluents have commonly been used for these methods, our columns are designed to work with both carbonate and hydroxide eluents. The Thermo Scientific Dionex IonPac AS23 is a high-capacity anionexchange column designed to work with carbonate eluents for the determination of trace bromate together with the common inorganic anions specified in EPA Method 300.0 B and 300.. Figure shows the determination of bromate at 5 µg/l along with the detection of bromide at 0 µg/l. The high-capacity Dionex IonPac AS9 column is designed to work with hydroxide eluent. Since the suppression product of hydroxide is water, this eluent enables greater sensitivity than carbonate eluents. Hydroxide eluents also allow the use of gradients, which expand separation possibilities. Figure 2 compares the selectivities of the two columns for the separation of disinfection byproducts. The use of a hydroxide eluent is also approved for EPA Methods 300.0 and 300. for anions and bromate determination. Column: Dionex IonPac AG23, AS23, 4mm Eluent: 4.5 mm Sodium carbonate/ 0.8 mm sodium bicarbonate Flow Rate:.0 ml/min Inj. Volume: 200 µl Detection: 0.3 Suppressed conductivity, Thermo Scientific Dionex ASRS ULTRA II, 4 mm, AutoSuppression external water mode 2 3 4 5 6 7 8 9 0 Peaks:. Fluoride.0 mg/l (ppm) 2. Chlorite 0.0 3. Bromate 0.005 4. Chloride 50 5. Nitrite 0. 6. Chlorate 0.0 7. Bromide 0.0 8. Nitrate 0 9. Carbonate 50 0. Phosphate 0.. Sulfate 50 Column: A) Dionex IonPac AG9, AS9, 4 mm B) Dionex IonPac AG23, AS23, 4 mm Flow Rate: Detection: Eluent: A) 0 mm KOH 0-0 min, 0-45 mm 0-25 min, 45 mm 25-30 min B) 4.5 mm potassium carbonate/ 0.8 mm potassium bicarbonate Peaks: Eluent Source: A) Thermo Scientific Dionex EGC II KOH with Dionex CR-ATC B) Dionex EGC III K 2 CO 3 + Dionex EPM 0.5 A.0 ml/min Inj. Volume: 250 µl Suppressed conductivity Dionex ASRS ULTRA II, 4 mm, A) Recycle mode B) External water mode. Chlorite 0 µg/l 2. Bromate 5 3. Chlorate 0 0. 500 4 0. 2 3 5 6 7 8 9 0 50 0 5 0 5 20 25 30 Figure. Determination of trace concentrations of bromate using the Dionex IonPac AG23 and AS23 columns with a large-loop injection. 0.25 B 2 3 0.5 0 5 0 5 20 25 30 Figure 2. Different column selectivities in the separation of disinfection byproducts: A) Dionex IonPac AG9/AS9 columns; B) Dionex IonPac AG23/AS23 columns. 4

Bromate analysis using Reagent-Free IC systems While EPA Methods 300.0 B and 300. have traditionally used a manually prepared eluent, Thermo Scientific has improved sensitivity and reproducibility with the introduction of Reagent-Free IC (RFIC ) systems. Our RFIC systems eliminate the need to manually prepare eluents, combining electrolytic eluent generation with self-regenerating suppression. By electrolytically producing high quality eluents from deionized water, RFIC systems save time and improve method performance for bromate detection. As shown in Figure 3, electrolytically generated hydroxide eluents facilitate both an improved separation of bromate from chloride (the major component) and an improved limit of detection. This application provides greater sensitivity than conventional IC with manually prepared eluents, and can determine bromate at sub-ppb levels. Electrolytically generated eluents are approved for use with EPA Methods 300.0 B and 300. to determine bromate and the seven inorganic anions required for regulation. Electrolytically generated KOH is available for use with the Dionex IonPac AS9 column. Precise control of current allows repeatable concentrations and gradients for improved reproducibility over manually prepared eluents and standard proportioning valves. The Dionex IonPac AS23 column can be used with electrolytically generated potassium carbonate to automatically and reproducibly generate carbonate/ bicarbonate eluent at the desired concentration. Column: Dionex IonPac AG9, AS9, 4 mm Eluent: 0 mm KOH 0-0 min, 0-45 mm 0-25 min, 45 mm 25-30 min Eluent Source: Dionex EGC II KOH with Dionex CR-ATC Flow Rate:.0 ml/min Inj. Volume: 250 µl Detection: Suppressed conductivity Dionex ASRS ULTRA II, 4 mm, recycle mode Peaks:. Fluoride 2. Chlorite.0 µg/l 3. Bromate 0.5 4. Chloride 5. Nitrite 6. Chlorate.0 7. Bromide 8. Nitrate 9. Carbonate 0. Sulfate. Phosphate 2 3 0.5 4 8 9 0 7 6 2 3 5 0.2 0 5 0 5 20 25 30 Figure 3. Chromatogram of mineral water spiked with µg/l each chlorite and chlorate and 0.5 µg/l bromate. 5

EPA Methods 37.0/326.0 & ISO Method 206 postcolumn reaction & visible detection While suppressed conductivity is the most popular detection technique, bromate recovery will be reduced in the presence of highsalt concentrations. Since surface and ground waters can contain chloride and sulfate in excess of 50 ppm, the resolution of bromate diminish due to interference from these two salts. In order to achieve good chromatographic resolution in these circumstances, the use of postcolumn reagent with absorbance detection may be required. Thermo Scientific s postcolumn derivatization techniques combined with UV detection have been validated by the EPA for Methods 37.0 and 326.. These methods increase the specificity of bromate detection while yielding very low detection limits, and can also be used to quantify bromate at sub-μg/l concentrations. Our applications meet the requirements of U.S. EPA Method 37.0 and 326.0 by achieving a method detection limit (MDL) of 0. µg/l. Figure 4 compares the results of the analysis of drinking water using suppressed conductivity and postcolumn derivatization with UV detection after separation on a Dionex IonPac AS9-HC column with a carbonate/bicarbonate eluent. The postcolumn technique reduces the calculated bromate MDL to 0.06 μg/l, which exceeds even the European Commission s low detection limits specified for bottled mineral waters. By using the Dionex IonPac AS9 column, applying an electrolytically generated hydroxide eluent combined with the postcolumn KI reaction, the MDL is further reduced to 0.04 μg/l. Figure 5 demonstrates the sensitivity of postcolumn derivatization and UV detection of disinfection byproducts (DBPs) compared to suppressed conductivity on a Dionex IonPac AS9 column. Column: Dionex IonPac AG9-HC, AS9-HC Eluent: 9.0 mm Sodium carbonate Flow Rate:.30 ml/min Inj. Volume: 225 µl Detection: A) Suppressed conductivity, Dionex Anion Atlas external water mode B) Absorbance, 352 nm Postcolumn Reagent: Acidified KI PCR Flow Rate: 0.4 ml/min Postcolumn Temperature: 80 C 26.25 A 3 Peaks (A):. Chlorite.85 µg/l (ppb) (Conductivity) 2. Bromate 0.33 3. DCA* 4. Bromide 20.3 5. Chlorate 82.9 Peaks (B): 2. Bromate 0.2 µg/l (ppb) (UV) * DCA = Dichloroacetate Quality control surrogate Column: Dionex IonPac AG9, AS9, 4 mm Eluent: 0 mm potassium hydroxide for 0 0 min, 0-45 mm potassium hydroxide for 0 25 min Eluent Source: Dionex EGC II KOH with Dionex CR-ATC Flow Rate: ml/min Inj. Volume: 250 µl Temperature: 30 ºC Detection: (A) Dionex ASRS ULTRA II, 4 mm, external water mode (B) Absorbance, 352 nm.5 A 2 Postcolumn Reagent: Acidified potassium iodide (KI) PCR Flow Rate: 0.3 ml/min Postcolumn Heater: 80 ºC Peaks (A):. Bromate 2.4 µg/l (ppb) 2. Chlorate 62.4 3. Bromide 7.5 Peaks (B):. Bromate 2.8 2 5 4 0.7 0.025 B 3 25.25 0.004 B AU 6-0.00 AU 2 0 5 0 5 20 Figure 4. Determination of DBP anions in drinking water using: A) suppressed conductivity detection; and B) UV absorbance detection after postcolumn reaction with acidified KI. 0.03 0 5 0 5 20 25 30 Figure 5. Determination of trace DBP anions and bromide in tap water using: A) suppressed conductivity detection; and B) UV absorbance after postcolumn reaction with acidified KI.

EPA Method 302.0 bromate analysis with 2D-IC and suppressed conductivity EPA Method 302.0 provides another strategy for bromate determination in high salt matrices two-dimensional IC (2D-IC). 2D-IC allows the use of an RFIC system for both dimensions with conductivity detection to yield sub-ppb detection limits. Automated column switching, facilitated by the Thermo Scientific Dionex ICS-5000 system and Thermo Scientific Chromeleon Chromatography Data System software, makes it possible to remove matrix ions before analysis. A high-volume water sample is injected onto a high-capacity 4 mm Dionex IonPac AS9 column using a KOH gradient. Bromate is partially resolved from matrix ions, a cut volume containing the bromate is transferred to the second dimension, and the matrix ions are flushed to waste. In the second dimension, the sample is collected on a concentrator column and resolved on a Dionex IonPac AS24, 2 mm column. Figure 7 shows the results of a 2D-IC separation of bromate in a high-salt matrix. The upper chromatogram shows that the bromate is not resolved from the chloride in this sample by the Dionex IonPac AS9, 4 mm column. The lower chromatogram shows the results after separation on a Dionex IonPac AS9 column, reinjection of a cut sample onto a concentrator column, and separation on a Dionex IonPac AS24, 2 mm column. The bromate that was undetectable in the first dimension is fully resolved in the second. Using this 2D-IC technique, an MDL of 0.036 μg/l can be achieved in high-salt matrices. st Dimension Large-loop injection Partially resolved matrix Pump EG Large Loop Cell 2 Figure 6. 2D-IC configuration. 2nd Dimension Resolve on smaller column Sensitivity enhancement Different selectivity optional Injection Valve CRD Suppressor 4 mm Column 0.4 mm Column Suppressor CRD Cell Switching Valve Intermediate Step Remove time segment Trap and concentrate ions of interest Dionex IonPac UTAC-ULP Ultra Trace Anion Concentrator column EG Pump Column A: Dionex IonPac AS9, 4 mm Eluent: 0 mm KOH 0 2 min, 65 mm 2. 35 min Flow Rate:.0 ml/min Inj. Volume: 000 µl Detection: Suppressed conductivity, Dionex ASRS ULTRA II, 4 mm, external water mode, 6 ma 0.6 0.3 A B st Dimension 0 0 20 30 35 2 nd Dimension Column B: Dionex IonPac AS24, 2 mm Eluent: 0 mm KOH 0 24 min, 65 mm 24. 35 min Flow Rate: 0.25 ml/min Cut Volume: 2000 µl Detection: Suppressed conductivity, Dionex ASRS ULTRA II, 2 mm, external water mode, 4 ma Concentrator: Thermo Scientific Dionex TAC-ULP (5 23 mm) Peak:. Bromate 0.5 µg/l 0.6 0 0 20 30 35 Figure 7. Two-dimensional bromate analysis using: A) a 4 mm Dionex IonPac AS9 column in the first dimension; and B) a 2 mm Dionex IonPac AS24 column in the second dimension. 7

Applications for Bromate in Water Using IC AN 208: Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device uses a Dionex IonPac AS23 along with the Thermo Scientific Dionex CRD-300 Carbonate Removal Device to reduce background noise with a carbonate eluent to achieve less than ppb MDL. AN 67: Determination of Trace Concentrations of Oxyhalides and Bromide in Municipal and Bottled Waters Using a Hydroxide-Selective Column with a Reagent-Free Ion Chromatography System uses a Dionex IonPac AS9 and RFIC hydroxide to improve sensitivity compared to carbonate eluents with conductivity detection. AN 7: Determination of Disinfection Byproduct Anions and Bromide in Drinking Water Using a Reagent-Free Ion Chromatography System Followed by Postcolumn Addition of an Acidified On-Line Generated Reagent for Trace Bromate Analysis uses the Dionex IonPac AS9 and RFIC hydroxide to replace the Dionex IonPac AS9-HC and carbonate eluent with postcolumn KI and visible detection. AN 68: Determination of Trace Concentrations of Disinfection By-Product Anions and Bromide in Drinking Water Using Reagent-Free Ion Chromatography Followed by Postcolumn Addition of o-dianisidine for Trace Bromate Analysis uses a Dionex IonPac AS9 and RFIC hydroxide to replace a Dionex IonPac AS9-HC and carbonate eluent with postcolumn ODA and visible detection. AN 87: Determination of Sub-μg/L Bromate in Municipal and Natural Mineral Waters Using Preconcentration with Two-Dimensional Ion Chromatography and Suppressed Conductivity Detection is a two dimensional IC method using the Dionex IonPac AS9 (4 mm), Dionex IonPac AS24 (2 mm), and RFIC hydroxide with conductivity detection that is comparable and lower than ODA and KI visible detection methods for bromate detection in high ionic strength matrices. AN 84: Determination of Trace Concentrations of Chlorite, Bromate, and Chlorate in Bottled Natural Mineral Waters demonstrates that the Dionex IonPac AS9 and RFIC hydroxide eluent provides lower detection limits than the Dionex IonPac AS23 carbonate column, and can be used to meet new EU 3 µg/l detection limits for natural mineral and spring waters, as previously shown in AN 67. AN 8: Ion Chromatographic Determination of Oxyhalides and Bromide at Trace Level Concentrations in Drinking Water Using Direct Injection uses direct Injection with a 250 µl loop and the Dionex IonPac AS9-HC to meet the 0 µg/l regulatory requirement and conductivity detection. AN 36: Determination of Inorganic Oxyhalide Disinfection Byproduct Anions and Bromide in Drinking Water Using Ion Chromatography with the Addition of a Postcolumn Reagent for Trace Bromate Analysis demonstrates the Dionex IonPac AS9-HC and carbonate eluent with postcolumn ODA and absorbance detection. AN 49: Determination of Chlorite, Bromate, Bromide, and Chlorate in Drinking Water by Ion Chromatography with an On-Line-Generated Postcolumn Reagent for Sub-µg/L Bromate Analysis uses a Dionex IonPac AS9-HC and carbonate eluent using postcolumn KI and absorbance detection. AU 54: Determination of Bromate in Drinking and Mineral Water by Isocratic Ion Chromatography with a Hydroxide Eluent demonstrates that the Dionex IonPac AS9 with RFIC hydroxide in isocratic mode cannot determine all the inorganic anions like the gradient method in AN 67. TN 6: Determination of Bromate by ISO Method 206 uses a Dionex CarboPac PA and MSA eluent with postcolumn KI and visible detection. www.thermoscientific.com/dionex 202 Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Thermo Scientific Dionex products are designed, developed, and manufactured under an ISO 900 Quality System. Australia +6 3 9757 4486 Austria +43 66 5 25 Benelux +3 20 683 9768 +32 3 353 42 94 Brazil +55 373 540 China +852 2428 3282 Denmark +45 36 36 90 90 France +33 39 30 0 0 Germany +49 626 99 0 India +9 22 2764 2735 Ireland +353 644 0064 Italy +39 02 5 62 267 Japan +8 6 6885 23 Korea +82 2 3420 8600 Singapore +65 6289 90 Sweden +46 8 473 3380 Switzerland +4 62 205 9966 Taiwan +886 2 875 6655 UK +44 276 69722 USA and Canada +847 295 7500 BR7026_E 09/2S