Ion Exchange Determination of Na+ by Displacement and Zn 2+ Using Preconcentration. Reading: Harris pp , 699

Similar documents
Experiment 7A ANALYSIS OF BRASS

EXPERIMENT 14. ACID DISSOCIATION CONSTANT OF METHYL RED 1

Determination of Orthophosphate Ion

O H 3 O 1 1 A. O 1 1 OH (K w

Scientific Observations and Reaction Stoichiometry: The Qualitative Analysis and Chemical Reactivity of Five White Powders

Determination of Orthophosphate Ion

The Fragrance of Rum, Isobutyl Propionate

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

PRACTICAL 3 ph AND BUFFERS

Water Hardness and Softening (Bring a water sample from home) Minneapolis Community and Technical College Principles of Chemistry II, C1152 v.2.

Chemical Equilibrium: Finding a Constant, Kc

Experiment 18 - Absorption Spectroscopy and Beer s Law: Analysis of Cu 2+

CHEM 334 Quantitative Analysis Laboratory

Experiment 8: DETERMINATION OF AN EQUILIBRIUM CONSTANT

Flushing Out the Moles in Lab: The Reaction of Calcium Chloride with Carbonate Salts

Determination of trace anions in concentrated hydrofluoric acid

Aspirin Lab By Maya Parks Partner: Ben Seufert 6/5/15, 6/8/15

Solubility of KHT and Common ion Effect

SOIL ORGANIC CONTENT USING UV-VIS METHOD

The Synthesis and Analysis of Aspirin

Volumetric Measurement Techniques. Technique #1 Use of a Burette. Technique #2 Use of a Pipette. Technique #3 Use of a Volumetric Flask

Identification Of The Common Laboratory Glassware, Pipettes And Equipment. BCH 312 [Practical]

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide:

Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste

Experiment 8 and 9 Weak Acids and Bases: Exploring the Nature of Buffers

Spectrophotometric Determination of an Equilibrium Constant

Synthesis and Analysis of a Coordination Compound

The Fluorometric Determination of Acetylsalicylic Acid in an Aspirin Tablet

Lab 04 Equilibrium Constant of Ferric Thiocyanate

Studies of a Precipitation Reaction

Potentiometric measurement of ph

Laboratory Measurements and Procedures

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

Part II. Cu(OH)2(s) CuO(s)

Acid-Base Titration. M M V a

Experiment 8 Introduction to Volumetric Techniques I. Objectives

Tetraphenylborate Method Method to 7.0 mg/l K Powder Pillows

STOICHIOMETRY AND THE CHEMICAL REACTION

In this laboratory exercise we will determine the percentage Acetic Acid (CH 3 CO 2 H) in Vinegar.

Determination of the Equilibrium Constant for the Iron (III) thiocynate Reaction

PART II: ANALYSIS OF IRON COORDINATION COMPOUND

DR/4000 QUATERNARY AMMONIUM COMPOUNDS PROCEDURE. 2. The display will show: 3. Fill a sample cell (the blank) with 25 ml of deionized water.

EXP. 9 EVALUATION OF METHODS FOR DETECTING AMMONIUM: ION SELECTIVE ELECTRODES AND SPECTROSCOPY

EXPERIMENT 20. Solutions INTRODUCTION

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Preparation of a Coordination Compound. Step 1 Copy the balanced equation for the preparation of FeC 2 O 4.. 3H2 O from FeC 2 O 4. Mass of watch glass

The Determination of an Equilibrium Constant

CHAPTER - 3 ANALYTICAL PROFILE. 3.1 Estimation of Drug in Pharmaceutical Formulation Estimation of Drugs

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

Spectrophotometric Determination of pka of Phenol Red

ANALYTICAL TASK EXPERIMENTAL PROCEDURE

Chemical Equilibrium: Finding a Constant, Kc

EXPERIMENT 16 Electrochemical Cells: A Discovery Exercise 1. Introduction. Discussion

Experiment 7 Buffer Capacity & Buffer Preparation

WEEK 2 EXP. 9 EVALUATION OF METHODS FOR DETECTING AMMONIUM: ION SELECTIVE ELECTRODES AND SPECTROSCOPY

Exercise 6: Determination of Hardness of Water

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Chemical Equilibrium: Finding a Constant, Kc

Chemistry Determination of Mixed Acids

# 12 ph-titration of Strong Acids with Strong Bases

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Experiment 20: Analysis of Vinegar. Materials:

Name: Date: AP Chemistry. Titrations - Volumetric Analysis. Steps for Solving Titration Problems

Acid-Base Titration Acetic Acid Content of Vinegar

Cl 2(g) + NaCl + H 2 O. light. 2Cl. Once formed, the chlorine radical can react with the heptane as shown below: + Cl

EXPERIMENTAL DETAILS

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Spectrophotometric Determination of Ferrocyanide in Effluents

METHOD 9035 SULFATE (COLORIMETRIC, AUTOMATED, CHLORANILATE)

MEASUREMENT: PART II

Introduction to Spectroscopy: Analysis of Copper Ore

THE IRON(III) THIOCYANATE REACTION SYSTEM

April 23, 2015 Lab 1 - Gravimetric Analysis of a Metal Carbonate

DR/4000 PROCEDURE. IRON, Total

EXPERIMENT 5: PHOTOMETRIC DETERMINATION OF AN EQUILIBRIUM CONSTANT

Rate law Determination of the Crystal Violet Reaction Using the Isolation Method

Volumetric Analysis. Quantitative analysis answers the second question

EXPERIMENT. Titration for Acetic Acid in Vinegar

DR/4000 PROCEDURE NITRATE. 2. The display will show:

Sodium Chloride - Analytical Standard

Determination of an Equilibrium Constant

Chemical Equilibrium: Finding a Constant, Kc

Determination of the Equivalent Weight and Ionization Constant of a Weak Acid

Salicylate Method Method HR (2 to 47 mg/l NH 3 N) TNTplus 832

Objectives To prepare a dilute solution of a weak acid. To prepare a buffer of a specific ph value.

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1

ASCORBIC ACID METHOD FOR PHOSPHORUS DETERMINATION

Determination of the K a Value and Molar Mass of an Unknown Weak Acid

Operating Instructions for Ammonium ISE Specifications

The Determination of an Equilibrium Constant

DETERMINATION OF THE SOLUBILITY PRODUCT OF GROUPII HYDROXIDES

Quaternary Ammonium Compounds

Chemistry 1B Experiment 11 49

Safety Note: Safety glasses and laboratory coats are required when performing this experiment

To understand concept of limiting reagents. To learn how to do a vacuum filtration. To understand the concept of recrystallization.

The Determination of an Equilibrium Constant

Spectrometric Determination of the Acid Dissociation Constant of an Acid-base Indicator

Experiment 3: Acids, Bases, and Buffers

Experiment 1 (Part A): Plotting the Absorption Spectrum of Iron (II) Complex with 1,10- Phenanthroline

Introduction to Spectroscopy: Analysis of Copper Ore

Transcription:

Ion Exchange Determination of a+ by Displacement and Zn 2+ Using Preconcentration Reading: Harris pp. 641647, 699 Prelab Assignment: 1. The ph of a solution is 4.56. Determine the concentration and use significant figure rules to calculate the number of significant figures in the final result. 2. Using the procedure in Part 2, the colorimetric procedure determined the Zn 2+ concentration in the 25 ml sample of eluant as 1.89x10 5 M. The original stock solution before preconcentration was 5.00x10 6 M Zn 2+. Calculate the percent recovery. 3. Bring the instrument instructions for the Hewlet Packard 8452A Diode Array UV/Visible Spectrophotometer to lab. Theory Ion Exchange: Ion exchange resins consist of charged functional groups attached to a polymeric backbone. For cation exchange resins the charged group is most often the sulfonate group, S 3. For anion exchange resins the charged group is most often a quaternary ammonium ion, (CH 3 ) 3 +. The mechanism of ion exchange can be pictured with the aid of Figure 1. In acidic solution the charged groups in a cation exchange resin will be associated with. If a sample containing a + is added to the solution, some of the ions will exchange with a + ions. The following exchange reaction takes place: [Resin] + a + [Resin] a + + (1) The resulting can be determined by titration and used to calculate the original concentration of the exchanged ion in solution. The exchange in Eq. 1 can be described by an equilibrium expression: K = [Resin a + ] [ ] [Resin ] [a + ] (2) a + + 3 a + a + a + + 3 Figure 1. Cation exchange

Different ions have different equilibrium constants. The greater the affinity of an ion for the ion exchange resin the further the position of equilibrium will lie to the right and the greater the equilibrium constant will be. In many uses, a mixture of ions is exchanged onto the column. The exchanged ions can later be removed (eluted) from the resin using acid solutions of increasing strengths. The order of elution of ions can be predicted by knowing the equilibrium constants for each of the ions in the sample. Ions with small K's will have smaller affinity for the resin and will elute at lower acid concentration. For elution, any ion will do, as long as the ion is not one that is being determined. Common elution solutions include HCl, acl, sodium acetate, and ammonium acetate. Ion exchange resins are used in many different formats. Ion exchange resins are often used in low pressure chromatography columns with gravity elution or low pressure pumps. Small particle ion exchange resins are used in high performance liquid chromatography, HPLC, columns for very highresolution separations. For sample preparation, ion exchange resins can be packed as beads into syringe cartridges or used to form filtration membranes. For small volume samples, milligram quantities can be packed into autopipettor plastic tips (Ziptips). For this experiment we will use a larger volume cartridge format, called a solidphase extraction cartridge. Solid Phase Extraction, SPE Solid phase extraction, SPE, cartridges are a commonly used tool for sample preparation. The cartridge can be packed as an open tube or as a syringe type filter. SPE cartridges are available in a variety of chemistries. Silica particles that have C 18 chains attached are the most common SPE packing. For C 18 SPE cartridges, nonpolar compounds are retained in the cartridge while polar compounds and salts can be washed through. In our experiment, ion exchange SPE cartridges will be used to introduce you to these powerful tools. C 18 and ion exchange SPE are very commonly used in analytical and biochemical sample preparation. DA and polar proteins are polyelectrolytes that can interact with an ion exchange resin in the same fashion as the simple ions in this experiment. Part 1. Ion Exchange Determination of a + by Displacement We will use commercial solid phase extraction cartridges to determine the total cation concentration in a sample. The cations will displace ions from the hydrogen ion form of the resin, and the hydrogen ion concentration resulting will be determined using a ph meter. S 3 R + a + > a + S 3 R + H+ The plastic cartridges hold 300mg of the ion exchange resin. The ion exchange capacity is about 0.45 meq. Here meq means milliequivalents. For unipositive ions like a +, milliequivalents is the same as millimoles. Ion exchange columns may be regenerated and reused. To regenerate a column, 0.1 M HCl is passed through the column in excess. Then the column is washed at least three times with reagent grade water. To determine if the excess acid has been washed from the column, you can test the wash water with a ph electrode, or even better, you can use Ag 3 solution to check for the presence of Cl.

The sample in this exercise contains only acl. However, environmental samples are often complex mixtures. This determination will not discriminate amoung any particular cation. All cationic species will in general be determined. For example, in a mixture of acl, KCl, and CuCl 2, the generated will be equal to the total number of moles of positive charge (equivalents) of all ions. Procedure: Equipment Required: Fisher P457 PrepSepSCX Solid Phase Extraction Cartridge 2x 25mL volumetric flasks 10mL volumetric pipet 3x 30mL beakers 2x 50mL beakers 10mL graduated cylinder ph meter and ph electrode blue litmus paper Solutions: Unknown (about 25 ml of 2.50x10 3 M acl as supplied by instructor) 10 ml of 0.1 M HCl 10 ml of 0.3 M acl ph 7 and ph 4 phosphate buffers ph Meter Calibration: Use standard ph 7 and ph 4 phosphate buffers to calibrate the ph meter. To help insure accurate readings, keep two beakers of reagent grade rinse water so that you can rinse the electrode twice between each change of sample. Always rinse in the same order so that the second rinse stays cleaner. Sample Preparation: Place a plastic bottle in the white plastic filtration apparatus to collect the filtrate. Assemble the filtration apparatus. If the blue valve handle is vertical, the valve is closed. If the blue valve handle is horizontal the valve is open and vacuum will be applied to the SPE cartridge. To regenerate the ion exchange resin, rinse the SPE cartridge with 10 ml of 0.1 M HCl, and then three washes of 10 ml of water. A graduated cylinder can be used for the acid and a wash bottle for the rinses. Remove the top of the filtration apparatus and touch the stainless steel tip to a piece of litmus paper to check for sufficient rinsing. If the litmus paper turns red, wash with several more 10 ml portions of water. Rinse the plastic bottle several times with reagent grade water and put it back in to the filtration apparatus. Collect two more 10 ml rinses. Determine the ph of this solution. Continue rinsing until the ph is greater than 5.8. Place a 25mL volumetric flask inside the plastic filtration apparatus to collect the filtrate and reassemble the filtration apparatus. Transfer your unknown quantitatively into a 25 ml volumetric flask. Dilute to the mark with reagent grade water and mix well. Transfer 10 ml of this solution into your SPE cartridge using a volumetric pipet. After pulling this solution through the SPE cartridge, follow the sample solution with two small portions of water (23 ml) from your wash bottle to ensure quantitative transfer. Remember that the volumetric flask holds only

25 ml, so don't add too much wash water. Remove the 25mL flask and dilute to the mark with reagent grade water. ph Determination: Rinse the ph electrode twice with reagent grade water. Carefully and gently dry the ph electrode with a ChemWipe to avoid dilution of your filtrate solution. Pour half of your sample into a clean, dry 30mL beaker and determine the ph. Empty the beaker and refill with the other half of your filtrate solution and repeat the ph determination. Report the average of the two results. Use the difference in the two readings to estimate the uncertainty of your results. Rinse the ph electrode twice and determine the ph of the ph 4 buffer solution to check for drift in the meter calibration. If the meter calibration has changed, use the difference to help estimate the uncertainty in your results. Calculations and Report: Report the average ph and your estimated uncertainty. Calculate the a + concentration and uncertainty in your original sample (in the 25mL volumetric flask diluted to the mark). Do the error analysis two different ways and compare the estimated uncertainties: first using significant figure rules and second using propagation of errors rules. Compare your uncertainty to the expected uncertainty that would be expected if you had used a titration to determine the ion concentration. Part 2. Ion Exchange Preconcentration and Colorimetric Determination of Zn 2+ Many techniques lack the necessary detection limits to work well for environmental samples. ne commonly used method to overcome these limitations is preconcentration. Sample evaporation is an obvious and commonly used technique, but evaporation is a slow process. Ion exchange is often used to preconcentrate ionic analytes. In this experiment we will use the colorimetric reagent Zincon to determine the Zn 2+ concentration in a dilute unknown, Figure 1. Zincon in ph 9.2 sodium borate buffer can be used to determine Zn 2+ from 0.013.0 mg/l, that is 0.013.0 ppm. 1 However, this range is not sensitive enough for most natural surface water samples. In this exercise we will preconcentrate only by a factor of eight, to save time. However, greater concentration factors can easily be achieved. The Zn 2+ ions will be eluted from the SPE cartridge using acl solutions of different concentrations. Zn 2+ S Figure 2: Zn 2+ Zincon complex.

ther than improved detection limits, ion exchange preconcentration is also useful for separating the desired analyte from interfering species. For example, colored substances in lakes and streams can interfere with colorimetric tests. In this exercise, we will first elute the column with 0.01 M acl to wash off any interfering substance that is less weakly bound than Zn 2+. This dilute acl elution will help to wash off colored species (which are typically anionic tannins). Typical colorimetric reagents, inculding Zincon, are not completely specific for only one metal. Iron(III) also forms colored complexes with Zincon. By carefully choosing the acl concentration of the elution, ions that are more strongly held to the resin than Zn 2+ can be left on the column. Typically, ions with higher charge have a larger equilibrium constant for binding on the resin. In this experiment, we elute Zn 2+ from the column using 0.3 M acl to avoid washing off Fe 3+. Rather than doing this experiment with an unknown, we will run this experiment as a method development lab. In this development effort you will determine the effect of the concentration of the acl elution solution and also determine how efficiently the total amount of Zn 2+ in the starting solution can be preconcentrated and determined. The efficiency of the overall process is often quoted as the percent recovery. That is, the percent recovery is the total number of moles of sample recovered after preconcentration divided by the initial sample moles multiplied by 100 to get a percentage. Procedure: Equipment Required: Fisher P457 PrepSepSCX Solid Phase Extraction Cartridge 200mL volumetric flask 2x 25mL volumetric flasks 10mL graduated cylinder 7x 25mL volumetric flasks 7x plastic visible cuvettes blue litmus paper 1mL autopipettor Solutions: 200mL of 5.00x10 6 M ZnCl 2 10 ml of 0.01 M acl 10 ml of 0.3 M acl 100 ml of 1x10 4 M Zincon in 20 mm ab 4 7 ph 9.2 buffer 6 ml of 1.00x10 4 M ZnCl 2 10 ml of 20 mm ab 4 7 ph 9.2 buffer Sample Preconcentration: Place a plastic bottle in the white plastic filtration apparatus to collect the filtrate and assemble the filtration apparatus. If the blue valve handle is vertical, the valve is closed. If the blue valve handle is horizontal the valve is open and vacuum will be applied to the SPE cartridge. Rinse the SPE cartridge with 10 ml of 0.1 M HCl, and then three washes of 10 ml of water. Remove the top of the filtration apparatus and touch the stainless steel tip to a piece of litmus paper to check for sufficient rinsing. If the litmus paper turns red, wash with several more 10 ml portions of water.

Fill a 200mL volumetric flask with 5.00x10 6 M ZnCl 2 solution to be used as your sample. Place your SPE cartridge into the rubber stopper on top of a glass sidearm filtration flask. Attach the flask to an aspirator and carefully allow all 200 ml of your sample to pass through your SPE cartridge. Rinse your 200mL volumetric flask with a small (23 ml) portion of water from a wash bottle and pour this wash through the SPE cartridge. Repeat this rinsing step twice more. Rinse the inside of the SPE cartidge with a small additional rinse to ensure quantitative transfer. Move your SPE cartridge back onto the white plastic filtration apparatus. Place a 25mL volumetric flask inside the plastic filtration apparatus to collect the filtrate. Use 10 ml of 0.01 M acl to elute the SPE cartidge. A graduated cylinder is fine for the acl solution. Follow the acl solution with two small portions of water (23 ml) from your wash bottle to ensure quantitative transfer. Remember that the volumetric flask holds only 25 ml, so don't add too much wash water. Remove the 25mL flask and dilute to the mark with 20 mm ab 4 7 ph 9.2 buffer. nce again, place a 25mL volumetric flask inside the plastic filtration apparatus. Use 10 ml of 0.3 M acl to elute the SPE cartidge. Follow the acl solution with two small portions of water (23 ml) from your wash bottle to ensure quantitative transfer. Remove the 25mL flask and dilute to the mark with 20 mm ab 4 7 ph 9.2 buffer. Colorimetric Analysis: You will prepare 2.50x10 6, 1.00x10 5, 2.00x10 5, and 3.00x10 5 M standard solutions of Zn 2+ in 5x10 5 M Zincon in 20 mm ab 4 7 ph 9.2 buffer. You will then prepare your two filtrate fractions in a similar fashion for analysis at 626 nm. The analytical wavelength at 626 nm is chosen slightly higher in wavelength than the absorbance maximum to provide a larger difference with the spectrum of uncomplexed Zincon. Standards: This procedure is designed for speed and makes some compromises that will decrease the precision of the analysis. For example, multiple cuvettes will be used instead of using the same cuvette for each measurement. However, the results should still meet the normally expected accuracy and precision of general spectrophotometric determinations of about 12%. For best accuracy, the absorbance in a colorimetric determination should be in the range of 0.2 to 0.8 (better monochromators extend this range to higher absorbances). Preconcentration is necessary in this experiment to bring the analyte signal into this range. Use a large volume autopipettor or bottletop pipettor to place 12.0 ml of 1x10 4 M Zincon in 20 mm ab 4 7 ph 9.2 buffer into each of seven 25mL volumetric flasks. Dilute one to the mark with 20 mm ph 9.2 buffer to act as a blank (i.e. zero concentration sample). In the second, dilute to the mark with 5.00x10 6 M ZnCl 2 solution. For the next three, place 2.00, 4.00, and 6.00 ml of 1.00x10 4 M ZnCl 2 solution, respectively, using an autopipettor. Dilute to the mark with ph 9.2 buffer. For your samples, simply dilute to the mark in the two remaining volumetric flasks. Fill seven plastic cuvettes with your samples. Using the I USB 4000 spectrophotometer scan the background with a cuvette filled with water and then determine the absorbances at 626 nm and 670 nm (as the background). Subtract the background absorbance at 670 nm from the absorbance at 626 nm to help correct for differences in cuvettes. Plot out the spectrum of the blank and the highest concentration standard. Calculations and Report: Plot the calibration curve and determine the slope and intercept using the "linest" Excel spreadsheet function. In addition, using "linest" you will be able to determine the uncertainty of

the slope and the intercept. From the slope and intercept calculate the concentration of Zn 2+ in your samples. Use the uncertainty in the slope and intercept to calculate the uncertainty in your results. In experiments of this type, the final results are often reported as percent recovery. Report the percent recovery. In your report, use your printed spectra to discuss why 626 nm was chosen for the analytical wavelength. Followup: Applications of Ion Excnge Resins Ion exchange resins are generally useful tools in analysis and synthesis laboratories. Ion chromatography allows the separation and determination of cations and anions with great efficiency and sensitivity. For example, rain, snow or tap water can easily be analyzed for partspermillion (ppm) levels of nitrate and sulfate. Ion exchange chromatography is also widely used for protein and oligonucleotide separations. SPE sample preparation is also common in biochemistry. ne example is for cation replacement for sample preparation for mass spectrometry. In this use, a + and K + ions are replaced by H 4 + using an SPE cartridge or Zip tip. Replacing the a + and K + ions simplifies the mass spectra and increases the sensitivity. Ion exchange resins are also used in synthesis. For example, a synthetic procedure may yield an ionic product with a Cl counter ion. Bulkier counter ions are often desired for the formation of crystals for Xray diffraction. Ion replacement by BF 4 or other bulky anions can sometimes make crystals easier to form. Substances other than the synthetic polymers used in this lab have ion exchange properties. Many clays have large ion exchange capacities. Clays are an important component of soils, which gives the typical soil an ion exchange capacity. The characterization of soils is an important branch of agricultural and environmental chemistry. Zeolytes, both natural and synthetic, can also act like ion exchange resins. Synthetic zeolytes are often added to laundry detergents to help avoid scum formation in hard water. These zeolytes exchange a + for the Ca 2+ and Mg 2+ ions that are responsible for water hardness. Literature Cited. 1. Hach Corp. Web site.