GA A26099 CO2 LASER POLARIMETER FOR FARADAY ROTATION MEASUREMENTS IN THE DIII-D TOKAMAK

Similar documents
GA A26474 SYNERGY IN TWO-FREQUENCY FAST WAVE CYCLOTRON HARMONIC ABSORPTION IN DIII-D

UPGRADED CALIBRATIONS OF THE THOMSON SYSTEM AT DIII D

PREDICTIVE MODELING OF PLASMA HALO EVOLUTION IN POST-THERMAL QUENCH DISRUPTING PLASMAS

Plasma Response Control Using Advanced Feedback Techniques

Scaling of divertor heat flux profile widths in DIII-D

GA A22722 CENTRAL THOMSON SCATTERING UPGRADE ON DIII D

GA A26686 FAST ION EFFECTS DURING TEST BLANKET MODULE SIMULATION EXPERIMENTS IN DIII-D

PLASMA MASS DENSITY, SPECIES MIX AND FLUCTUATION DIAGNOSTICS USING FAST ALFVEN WAVE

RWM FEEDBACK STABILIZATION IN DIII D: EXPERIMENT-THEORY COMPARISONS AND IMPLICATIONS FOR ITER

Advanced Interferometry Techniques for Burning Plasmas

GA A27857 IMPACT OF PLASMA RESPONSE ON RMP ELM SUPPRESSION IN DIII-D

TARGET PLATE CONDITIONS DURING STOCHASTIC BOUNDARY OPERATION ON DIII D

GA A23736 EFFECTS OF CROSS-SECTION SHAPE ON L MODE AND H MODE ENERGY TRANSPORT

GA A25853 FAST ION REDISTRIBUTION AND IMPLICATIONS FOR THE HYBRID REGIME

FAR SCRAPE-OFF LAYER AND NEAR WALL PLASMA STUDIES IN DIII D

OST! by R.T. SNIDER, T.N. CARLSTROM, T.D. HODAPP, F.C. JOBES, and W.A. PEEBLES JUNE 1996 GENE-& ATOM8CS. p*r-.m 7u. j.9

Simulation of Double-Null Divertor Plasmas with the UEDGE Code

STABILIZATION OF m=2/n=1 TEARING MODES BY ELECTRON CYCLOTRON CURRENT DRIVE IN THE DIII D TOKAMAK

GA A26741 SCINTILLATOR-BASED DIAGNOSTIC FOR FAST ION LOSS MEASUREMENTS ON DIII-D

GA A26123 PARTICLE, HEAT, AND SHEATH POWER TRANSMISSION FACTOR PROFILES DURING ELM SUPPRESSION EXPERIMENTS ON DIII-D

Role of Flow Shear in Enhanced Core Confinement

GA A22877 A NEW DC MAGNETIC SENSOR

GA A24166 SUPER-INTENSE QUASI-NEUTRAL PROTON BEAMS INTERACTING WITH PLASMA: A NUMERICAL INVESTIGATION

GA A27806 TURBULENCE BEHAVIOR AND TRANSPORT RESPONSE APPROACHING BURNING PLASMA RELEVANT PARAMETERS

GA A23797 UTILIZATION OF LIBEAM POLARIMETRY FOR EDGE CURRENT DETERMINATION ON DIII-D

GA A THERMAL ION ORBIT LOSS AND RADIAL ELECTRIC FIELD IN DIII-D by J.S. degrassie, J.A. BOEDO, B.A. GRIERSON, and R.J.

Shock compression of precompressed deuterium

GA A23713 RECENT ECCD EXPERIMENTAL STUDIES ON DIII D

PROJECT PROGRESS REPORT (03/lfi?lfibr-~/15/1998):

Differential Interferometry for Measurement of Density Fluctuations and Fluctuation Induced Transport

SciDAC CENTER FOR SIMULATION OF WAVE-PLASMA INTERACTIONS

GA A26057 DEMONSTRATION OF ITER OPERATIONAL SCENARIOS ON DIII-D

GA A27290 CALCULATION OF IMPURITY POLOIDAL ROTATION FROM MEASURED POLOIDAL ASYMMETRIES IN THE TOROIDAL ROTATION OF A TOKAMAK PLASMA

IMPACT OF EDGE CURRENT DENSITY AND PRESSURE GRADIENT ON THE STABILITY OF DIII-D HIGH PERFORMANCE DISCHARGES

CONTRIBUTIONS FROM THE NEUTRAL BEAMLINE IRON TO PLASMA NON-AXISYMMETRIC FIELDS

GA A27235 EULERIAN SIMULATIONS OF NEOCLASSICAL FLOWS AND TRANSPORT IN THE TOKAMAK PLASMA EDGE AND OUTER CORE

GA A23977 DETAILED MEASUREMENTS OF ECCD EFFICIENCY ON DIII D FOR COMPARISON WITH THEORY

Overview of equilibrium reconstruction on DIII-D using new measurements from an expanded motional Stark effect diagnostic

GA A25410 DISRUPTION CHARACTERIZATION AND DATABASE ACTIVITIES FOR ITER

INTERFEROMETER SYSTEMS ON LHD

GA A26785 GIANT SAWTEETH IN DIII-D AND THE QUASI-INTERCHANGE MODE

GA A22689 SLOW LINER FUSION

GA A27805 EXPANDING THE PHYSICS BASIS OF THE BASELINE Q=10 SCENRAIO TOWARD ITER CONDITIONS

Development of a High Intensity EBIT for Basic and Applied Science

GA A26110 MEASUREMENTS OF THE INTERNAL MAGNETIC FIELD ON DIII-D USING INTENSITY AND SPACING OF THE MOTIONAL STARK MULTIPLET

UNDERSTANDING TRANSPORT THROUGH DIMENSIONLESS PARAMETER SCALING EXPERIMENTS

GA A24016 PHYSICS OF OFF-AXIS ELECTRON CYCLOTRON CURRENT DRIVE

Faraday Effect Measurement of Internal Magnetic Field and Fluctuations in C-MOD

GA A23411 COMPARISON OF LANGMUIR PROBE AND THOMSON SCATTERING MEASUREMENTS IN DIII D

in the pinch. This paper describes the computer modeling behind the shielding design of a

Optimization of NSLS-II Blade X-ray Beam Position Monitors: from Photoemission type to Diamond Detector. P. Ilinski

Noninductive Formation of Spherical Tokamak at 7 Times the Plasma Cutoff Density by Electron Bernstein Wave Heating and Current Drive on LATE

GA A23114 DEPENDENCE OF HEAT AND PARTICLE TRANSPORT ON THE RATIO OF THE ION AND ELECTRON TEMPERATURES

A Distributed Radiator, Heavy Ion Driven Inertial Confinement Fusion Target with Realistic, Multibeam Illumination Geometry

Start-up Noise in 3-D Self-AmpMed

Impurity Transport Studies of Intrinsic MO and Injected Ge in High Temperature ECRH Heated FTU Tokamak Plasmas

Analysis of Shane Telescope Aberration and After Collimation

AC dipole based optics measurement and correction at RHIC

FUSION WITH Z-PINCHES. Don Cook. Sandia National Laboratories Albuquerque, New Mexico 87185

Development of a dispersion interferometer for magnetic confinement plasma and its application to atmospheric pressure plasmas

Modeling Laser and e-beam Generated Plasma-Plume Experiments Using LASNEX

GA A25592 STABILITY AND DYNAMICS OF THE EDGE PEDESTAL IN THE LOW COLLISIONALITY REGIME: PHYSICS MECHANISMS FOR STEADY-STATE ELM-FREE OPERATION

Multicusp Sources for Ion Beam Lithography Applications

CQNl_" RESPONSE TO 100% INTERNAL QUANTUM EFFICIENCY SILICON PHOTODIODES TO LOW ENERGY ELECTRONS AND IONS

Three-Dimensional Silicon Photonic Crystals

Two-Screen Method for Determining Electron Beam Energy and Deflection from Laser Wakefield Acceleration

GA A26239 FAST PLASMA SHUTDOWNS OBTAINED WITH MASSIVE HYDROGENIC, NOBLE AND MIXED-GAS INJECTION IN DIII-D

GA A27437 SCALING OF THE DIVERTOR HEAT FLUX WIDTH IN THE DIII-D TOKAMAK

Fission-Fusion Neutron Source

GA A26119 MEASUREMENTS AND SIMULATIONS OF SCRAPE-OFF LAYER FLOWS IN THE DIII-D TOKAMAK

Internal magnetic field measurement in tokamak plasmas using a Zeeman polarimeter

A new scheme for heterodyne polarimetry with high temporal resolution

GA A25351 PHYSICS ADVANCES IN THE ITER HYBRID SCENARIO IN DIII-D

GA A25684 A CONTINUOUS, IN-CHAMBER TARGET TRACKING AND ENGAGEMENT APPROACH FOR LASER FUSION

Summary Report: Working Group 5 on Electron Beam-Driven Plasma and Structure Based Acceleration Concepts

C S N f - 7 7Ob / 5'+RADIATION TEMPERATURE MEASUREMENTS

Applications of Pulse Shape Analysis to HPGe Gamma-Ray Detectors

GA A22677 THERMAL ANALYSIS AND TESTING FOR DIII D OHMIC HEATING COIL

Incoherent wind velocity sensing with a two-beam interferometer

Magnetic Measurements of the Elliptical Multipole Wiggler Prototype

(4) How do you develop an optimal signal detection technique from the knowledge of

BASAL CAMBRIAN BASELINE GEOLOGICAL CHARACTERIZATION COMPLETED

Multi-Scale Chemical Process Modeling with Bayesian Nonparametric Regression

GA A23198 HORIZONTAL THOMSON SCATTERING SYSTEMS FOR DIII D AND SSPX

PROJECT PROGRESS REPORT (06/16/1998-9/15/1998):

GA A23168 TOKAMAK REACTOR DESIGNS AS A FUNCTION OF ASPECT RATIO

INTERMOLECULAR POTENTIAL FUNCTIONS AND HIGH RESOLUTION MOLECULAR SPECTROSCOPY OF WEAKLY BOUND COMPLEXES. Final Progress Report

Scaling between K+ and proton production in nucleus-nucleus collisions *

N. Tsoupas, E. Rodger, J. Claus, H.W. Foelsche, and P. Wanderer Brookhaven National Laboratory Associated Universities, Inc. Upton, New York 11973

GA A22571 REDUCTION OF TOROIDAL ROTATION BY FAST WAVE POWER IN DIII D

To be published in the Proceedings of ICEC-22, Seoul Korea, July 2008 MICE Note 232 1

Using the X-FEL to understand X-ray Thomson scattering for partially ionized plasmas

GA A25658 PRECISION X-RAY OPTICAL DEPTH MEASUREMENTS IN ICF SHELLS

Quarterly Report April 1 - June 30, By: Shirley P. Dutton. Work Performed Under Contract No.: DE-FC22-95BC14936

Bulk Modulus Capacitor Load Cells

BWXT Y-12 Y-12. A BWXT/Bechtel Enterprise SMALL, PORTABLE, LIGHTWEIGHT DT NEUTRON GENERATOR FOR USE WITH NMIS

GA A26744 MEASUREMENTS OF THE INTERNAL MAGNETIC FIELD USING THE B-STARK MOTIONAL STARK EFFECT DIAGNOSTIC ON DIII-D

Abstract Submitted for the DPP99 Meeting of The American Physical Society

Calibration of and Measurements from the C-Mod MSE Diagnostic

ONION-SKIN METHOD (OSM) ANALYSIS OF DIII D EDGE MEASUREMENTS

Transcription:

GA A26099 CO2 LASER POLARIMETER FOR FARADAY ROTATION MEASUREMENTS IN THE DIII-D TOKAMAK by M.A. VAN ZEELAND, R.L. BOIVIN, T.N. CARLSTROM, and T.M. DETERLY MAY 2008

DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.

CO2 LASER POLARIMETER FOR FARADAY ROTATION MEASUREMENTS IN THE DIII-D TOKAMAK by M.A. VAN ZEELAND, R.L. BOIVIN, T.N. CARLSTROM, and T.M. DETERLY This is a preprint of a paper to be presented at the Seventeenth Topical Conference on High Temperature Plasma Diagnostics, May 11-15, 2008, in Albuquerque, New Mexico, and to be published in the Proceedings. Work supported by the U.S. Department of Energy under DE-FC02-04ER54698 and General Atomics IR&D Funding GENERAL ATOMICS ATOMICS PROJECT 30200 MAY 2008

ABSTRACT A tangential viewing, 10.59 µm laser polarimeter for electron density measurements based on plasma induced Faraday rotation has been installed on DIII-D. The system uses co-linear right and left-hand circularly polarized beams with a difference frequency of 40 MHz to generate the necessary signal for heterodyne phase detection. The high-resolution phase information required to adequately resolve degree level polarization rotation is obtained using an all-digital real-time phase demodulation scheme based on modern Digital Signal Processing techniques. Initial application of the system to DIII-D disruption mitigation experiments utilizing massive gas jet injection exhibits reliable operation and excellent agreement with interferometer measurements; interestingly, the obtained Faraday rotation angles are in the range of those expected in ITER plasmas. General Atomics Report GA A26099 iii

I. INTRODUCTION Reliable real-time measurements of electron density in tokamak plasmas and other fusion devices are essential for discharge control and optimization. Typically, the technique employed is some type of interferometric measurement of the plasma index of refraction where the specific probing wavelength is dependent on the density, size, and time-scales involved. For fusion plasma applications, low frequency interferometers operating in the microwave range often suffer from refraction off plasma density gradients as well as rapid fringe shifts from sudden density changes. Visible laser interferometers require sensitive alignment, are severely affected by optical component degradation as well as vibration and, in order to separate plasma from mechanical vibration effects, typically are required to operate simultaneously with a path sharing longer wavelength interferometer. While more complicated and inherently less sensitive, this well-established technique, known as twocolor vibration compensated interferometry (TCI), does not suffer from refraction and can reliably follow rapid plasma density changes [1,2]. For these reasons, two-color interferometers are often used for feedback control of plasma density in current tokamaks. The major problem with standard two-color interferometry, however, is the inherent susceptibility to fringe counting errors, i.e. fringe skips. This susceptibility to fringe-skip errors is an unacceptable drawback of TCI when being considered for application to the steady-state plasmas in next step fusion devices such as ITER; alternate real-time density measurements as well as mitigation techniques, should fringe skip errors occur, will be required. A promising method for fulfilling the line-density measurement requirements in ITER is standard TCI implemented in combination with a polarimetry measurement of the plasma induced Faraday rotation of the longer wavelength beam, where the longer wavelength is envisioned to be 10.59 µm from a laser [5,8,11]. Faraday rotation in a magnetized plasma results from the difference in index of refraction between left-hand (LH) and righthand (RH) polarized radiation and means a linearly polarized electromagnetic wave will see its plane of polarization rotated by and angle (α); where α = kλ 2 n e B d L, (1) where k = 2.62 10 13 Radians/T, λ is the wavelength, n e is the electron density, and B is the magnetic field component in the direction of propagation [7,8]. As such, a measurement of Faraday rotation is a measure of the line-integrated electron density weighted by the local parallel magnetic field strength. The rationale behind adding a polarimetry measurement to standard TCI is that for the majority of operating conditions the expected Faraday rotation of 10.59 µm radiation will always be less than 2π making fringe skips irrelevant. This additional measurement can then be used for re-normalizing TCI measurements, should a fringe skip occur, as well as possibly for density feedback control by itself [5]. General Atomics Report GA A26099 1

M.A. Van Zeeland et al. This paper describes the design, layout, and initial use of a tangentially viewing 40 MHz laser polarimeter on the DIII-D tokamak. In the interest of application to future realtime measurements, the system utilizes the same phase demodulation electronics as the existing real-time TCI system. Measurements of high-density gas-jet injection plasmas are demonstrated which take advantage of the polarimeter's large bandwidth and inherent dynamic range. The obtained line-density values are in agreement with a radially viewing TCI chord and, interestingly, are in the range of those expected in typical ITER plasmas. Extension to a simultaneous polarimeter/two-color interferometer is straightforward. 2 General Atomics Report GA A26099

II. POLARIMETER LAYOUT The polarimeter optical component layout is shown in Fig. 1. The basic principle of operation is that radiation from a 10.59 µm, 8 W,, fixed grating, waveguide laser is used to create both RH and LH circularly polarized radiation with a difference frequency of ω 1 = 40 MHz. Combined, these two beams form a linearly polarized wave with its plane of polarization rotating at ω 1 /2. This composite beam is split and a fraction is sent through a polarizer to a reference detector (Detector 1) and the other fraction is sent through the magnetized plasma and back, then through a polarizer and to a separate detector (Detector 2). Detector 1 sees an intensity signal given by I 1 (t) = A 1 sin[ω 1 t + φ v (t)] and Detector 2 sees I 2 (t) = A 2 sin[ω 1 t + φ v (t)+ 2α(t)]. Therefore, heterodyne detection can be applied to determine the Faraday rotation (α) where the LO signal is I 1 and the IF signal is I 2. Techniques similar to this have been applied at wavelengths [13] as well as longer FIR wavelengths [6] with success. Fig. 1. Optical component layout for polarimeter. The formation of the separate frequency RH and LH radiation is accomplished by using a single acousto-optic frequency shifter (AO). The AO cel splits the incident beam into equal amplitude components with linear polarization in the plane of the paper. The frequencyshifted component is then passed through a CdS λ /2 waveplate and its polarization is rotated by 90 deg. The two separate frequency, orthogonally polarized beams are then re-combined using a ZnSe thin film polarizer/combiner (TFP) operating at Brewster's angle. The composite beam is then passed through a CdS λ / 4 waveplate with its axis at 45 deg with respect the polarization vector of each frequency component forming the superimposed RH and LH waves at ω 0 and ω 0 + ω 1 respectively (i.e. rotating linearly polarized wave). It should be noted that the additional phase term φ v (t) present in the expression for I 1 and I 2 is relative to the 40 MHz AO drive signal and results from any vibration or path length variation introduced between the AO cel and the TFP. This additional phase shift leads to General Atomics Report GA A26099 3

M.A. Van Zeeland et al. errors in the measurement of α if one were to use the AO driver signal as the LO and is the primary reason for including a separate reference detector. In practice, the relative phase between I 1 and I 2 (2 Faraday rotation angle) is obtained by carrying out a separate demodulation of each signal relative to the AO cel drive frequency and taking the difference. The 40 MHz phase demodulation is accomplished by an all-digital scheme based on modern digital signal processing techniques implemented using a PCI card field programmable gate array and high speed (53.33 MS/s) analog-to digital converters. The real-time system is the same used for day-to-day operation of the DIII-D TCI system and is capable of better than 1/3 degree phase detection accuracy with 8 MHz bandwidth independent of IF amplitude variations up to 20%. The 16-bit phase data are stored at a sampling rate of 1.667 MS/s as well made available in real-time via analog outputs [3]. Calibration and noise floor tests of the polarimeter have been carried out using a rotating λ /2 waveplate in the beam path to simulate Faraday rotation. The measured response is linear with waveplate rotation angle, as expected, with the actual polarization rotation angle being twice that of the waveplate [6,12]. Phase noise tests show approximately 0.08 deg and 0.28 deg, phase noise with a bandwidth of 100 Hz and 1 khz, respectively. 4 General Atomics Report GA A26099

III. INSTALLATION AND MEASUREMENTS ON DIII-D The polarimeter's viewing trajectory on DIII-D is shown in Fig. 2 along with that of a radially viewing interferometer chord. The beams from both systems enter through a midplane BaF 2 window after which the polarimeter beam is steered tangentially via a solid copper mirror installed inside of the vacuum vessel. Copper was chosen due to its high conductivity in order to reduce the relative phase shift between S and P components resulting from large AOI ( 70 deg) effects. Due to its relatively low cost and transparency in the visible spectrum as well as infrared, BaF 2 is an attractive alternative to other choices for window material such as ZnSe and CVD diamond. It is well known that ZnSe has a large Verdet constant at 10.59 µm which can severely affect polarimetry measurements [10]. While CVD diamond has a negligible Verdet constant, windows of the required diameter (3.6 in.) are prohibitively expensive [10]. An exhaustive literature search has failed to produce the Verdet constant of BaF 2, however, estimates indicate it is as much as an order of magnitude less than ZnSe. The retroreflector for each system is approximately 2.5 in. diameter and constructed out of three orthogonal solid titanium mirrors [2]. Fig. 2. Polarimeter and Interferometer chord layout on DIII-D midplane. Both are double pass. Shown in Fig. 3 are polarimeter and radial interferometer data from DIII-D discharge 128645 in which massive gas jet injection (~ 550 Torr Liters H 2 ) occurs at t=1915 ms and the line averaged density ( n e ) rapidly increases from n e = 6.6 10 13 cm 3 to a maximum of n e 1.5 10 15 cm 3. The line-averaged density from the polarimeter measurements is approximated by using the average parallel magnetic field along the ray path ( B = 2.38 T) as calculated from an EFIT equilibrium reconstruction before gas jet injection and the total double-pass path length L = 7.9 m from LCFS to LCFS; giving n e α kλ 2 B L. (2) Using an average parallel magnetic field value is essentially the only way to arrive at a density measurement without explicitly knowing the profile shape itself. While they are not expected to be identical owing to different sightlines, magnetic field weighting, profile General Atomics Report GA A26099 5

M.A. Van Zeeland et al. asymmetries, etc., the radial interferometer chord provides an excellent check as to the accuracy of the polarimeter measurement. The temporal behavior of both measurements are qualitatively similar and the relative magnitudes of line-averaged density are in rough quantitative agreement. The actual onset of the initial gas jet density pulse is slightly different on the two different measurements due to their different average toroidal location and the finite propagation time of the pulse itself. Additionally, one can see the relative density difference before gas injection and long after is essentially the same for the polarimeter and interferometer and is an indication of the polarimeter's ability to measure the ambient n e = 6.6 10 13 cm 3 plasma. Fig. 3. Discharge 128645, polarimeter and interferometer measurements during gas jet injection. Line-averaged density on left axis (both) and Faraday rotation angle on right axis (polarimeter only). The actual polarimeter measured Faraday rotation angle ( α) is also shown in Fig. 3. It is interesting to note that the large rotation angles during gas injection ( 50 deg) are of similar magnitude as those predicted for tangentially viewing polarimeter chords operating at wavelengths in steady state ITER plasmas [5]. A simple estimate of this can be made by assuming L ITER / L D3D 4, B ITER / B D3D 2.75, n ITER /n gasjet 1/15, giving α ITER /α gasjet 0.73. 6 General Atomics Report GA A26099

IV. POTENTIAL ISSUES While gas jet injection experiments clearly show the utility of polarimeter measurements in DIII-D and these results extrapolate well to steady-state ITER plasmas the polarimeter system described in this article, as implemented, does not have sufficient linedensity resolution for measurements of typical DIII-D plasmas. This can be seen by looking at the time periods in Fig. 3 before and after gas jet injection ( t < 1915 ms and t > 1930 ms). The low frequency oscillations apparent in the Faraday Rotation signal are a result of optical component motion and highlight the need for real time feedback alignment to obtain subdegree resolution. Measurements of the error induced by beam motion transverse to the propagation direction indicate that approximately 1 mm motion across the detector can introduce errors as large as 1 deg in the measured Faraday rotation angles. This is consistent with measurements of the same error source in Ref. [12]. The magnitude of this error is extremely dependent on the degree to which the RH and LH wave are co-linear. Indeed, any offset in the presence of a non-uniform density profile will exacerbate the error by forming essentially a differential interferometer. Obtaining and preserving such precise alignment, however, is difficult and further development is required in this area along with feedback alignment. General Atomics Report GA A26099 7

V. CONCLUSIONS A laser polarimeter operating at 10.59 µm which uses a real-time phase demodulation system has been installed and operated on the DIII-D tokamak. The linedensity obtained through measurements of Faraday rotation during gas jet injection experiments show agreement with a radially viewing interferometer chord and the obtained rotation angles are in the range of those expected in ITER plasmas. Future work will include the construction of a feedback alignment system and the addition of a common path vibration compensated interferometer measurement to make the system more robust and applicable to typical DIII-D plasmas. General Atomics Report GA A26099 9

REFERENCES [1] M. A. Van Zeeland, R. L. Boivin, T. N. Carlstrom, T. M. Deterly, D. K. Finkenthal, Rev. Sci. Instrum. 77, 10F325-1 (2006). [2] T. N. Carlstrom, D. R. Ahlgren, and J. Crosbie, Rev. Sci. Instrum. 6, 1063 (1988). [3] C. Ziomek, P. Corredoura, Proc. of PAC 1995, Dallas, Texas (1995). [4] E. M. Hollmann, T. C. Jernigan, P. B. Parks, J. A. Boedo, T. E. Evans, M. Groth, D. A. Humphreys, A. James, M. Lanctot, D. Nishijima, D. L. Rudakov, H. A. Scott, E. J. Strait, M. A. Van Zeeland, J. C. Wesley, W. P. West, W. Wu, and J. H. Yu, Measurements of Injected Impurity Assimilation During Massive Gas Injection Experiments in DIII-D, to be submitted to Nucl. Fusion (2008). [5] ITER Tangential Interferometer and Polarimeter Evaluation Contract No. S-006972-F (2007). [6] D. L. Brower, Y. Jiang, W. X. Ding, S. D. Terry, N. E. Lanier, J. K. Anderson, C. B. Forest, and D. Holly, Rev. Sci. Instrum. 72, 1077 (2001). [7] W. X. Ding, D. L. Brower, B. H. Deng,, D. Craig, S. C. Prager, and V. Svidzinski, Rev. Sci. Instrum. 75, 3387 (2004). [8] Y. Kawano, S. Chiba, H. Shirai, A. Inoue, and A. Nagashima, Rev. Sci. Instrum. 70, 1430 (1999). [9] Y. Kawano, S. Chiba, and A. Inoue, Rev. Sci. Instrum. 72, 1068 (2001). [10] Y. Kawano, S. Chiba, and A. Inoue, Rev. Sci. Instrum. 75, 279 (2004). [11] T. Kondoh, A. E. Costley, T. Suge, Y. Kawano, A. Malaquias, and C. I. Walker, Rev. Sci. Instrum. 75, 3420 (2004). [12] T. Akiyama, S. Tsuji-lio, R. Shimada, K. Nakayama, S. Okajima, M. Takahashi, and K. Terai, Rev. Sci. Instrum. 74, 2695 (2003). [13] T. Akiyama, E. Sato, T. Nozawa, S. Tsuji-lio, R. Shimada, H. MNurayama, K. Nakayama, S. Okajima, K. Tanaka, K. Watanabe, T. Tokuzawa, and K. Kawahata, Rev. Sci. Instrum. 72, 1073 (2001). General Atomics Report GA A26099 11

ACKNOWLEDGMENT This work is supported by the US Department of Energy under DE-FC02-04ER54698 and General Atomics IR&D funding. The authors would like to thank Drs. D. Brower and W.X. Ding for useful discussions during the construction of this system as well as Dr. E. Hollman for allowing us to test the polarimeter during massive gas jet injection experiments. General Atomics Report GA A26099 13