Selection of a Capillary

Similar documents
Selection of a Capillary GC Column

Choosing the Correct GC Column Dimensions and Stationary Phase

How To Select the Correct GC Column. Simon Jones Application Engineer

Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist

Column Dimensions. GC Columns and Consumables. Mark Sinnott Application Engineer. March 12, 2010

Secrets of GC Column Dimensions

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Speakers. Moderator. John V Hinshaw GC Dept. Dean CHROMacademy. Tony Taylor Technical Director CHROMacademy. Dave Walsh Editor In Chief LCGC Magazine

The Suite for Environmental GC Analysis

Introduction and Principles of Gas Chromatography

Water Injections in GC - Does Water Cause Bleed?

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Introduction to Gas Chromatography

Low Bleed Stationary Phases for Gas Chromatography

Trajan SGE GC Columns

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms

Volatile organic compounds (VOCs):

Agilent J&W GC Column Selection Guide

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014

GC Resolution Do You See What I See?

Get Selective. By Jaap de Zeeuw

Gas Chromatography (GC)

Rely on Rxi -PAH Columns

Understanding Gas Chromatography

The Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Agilent J&W GC Column Selection Guide SPEED YOUR SELECTION WITH THIS ONE-STOP RESOURCE

Chromatography. Gas Chromatography

Introduction to Capillary GC

PAH Analyses with High Efficiency GC Columns: Column Selection and Best Practices

Supelco Ionic Liquid GC Columns Introduction to the Technology

Column Selection. there is more to life than a boiling point column. Jaap de Zeeuw Restek Corporation, The Netherlands. Copyrights: Restek Corporation

Ultra-Inert chemistry for Trace Level Analysis

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column

Continuous Improvement in Petroleum/Petrochemical Analysis HP s Family of Innovative PLOT Columns

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

2401 Gas (liquid) Chromatography

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

GAS CHROMATOGRAPHY. Mobile phase is a gas! Stationary phase could be anything but a gas

Gas Chromatography. Rosa Yu, David Reckhow CEE772 Instrumental Methods in Environmental Analysis CEE 772 #16 2

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

The Effects of Carrier Gas Viscosity and Diffusion on Column Efficiency in Capillary Gas Chromatography

Chemistry Instrumental Analysis Lecture 28. Chem 4631

GC Instruments. GC Instruments - Sample Introduction

Gas Chromatography (Chapter 2 and 3 in The essence of chromatography)

Introduction to Capillary GC

Ch24. Gas Chromatography (GC)

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Theory and Instrumentation of GC. GC Columns

Author. Abstract. Introduction

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Chapter 27: Gas Chromatography

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

CHEM340 Tutorial 4: Chromatography

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Seafood Using GC/MS

Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings

Gas Chromatography. Vaporization of sample Gas-solid Physical absorption Gas-liquid Liquid immobilized on inert solid

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

Theory and Instrumentation of GC. Chromatographic Parameters

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

Tar measurement by the Solid Phase Adsorption (SPA) method

Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column

Facility: Mansfield Revision 3. Title: PAHs by SPME Page 1 of 11

Evaluation of Capillary Columns for General Performance Parameters

Gas Chromatography. Introduction

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

This project has been funded with support from the European Commission. This publication reflects the views only of the authors, and the Commission

Activity in the FID Detection Port: A Big Problem if Underestimated

Partitioning. Separation is based on the analyte s relative solubility between two liquid phases or a liquid and solid.

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

CHAPTER 6 GAS CHROMATOGRAPHY

Gas chromatography. Advantages of GC. Disadvantages of GC

SUPELCO. Improved Performance for Cyanopropylphenyldimethylpolysiloxane (SPB-1701, SPB-1301) Capillary Columns

Application Note. Abstract. Authors. Environmental

Principles of Instrumental Analysis

Principles of Gas- Chromatography (GC)

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Chapter 11 Conventional Gas Chromatography

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Determination of Volatile Substances Proof of Food Adulteration

Rapid Analysis of Food and Fragrances Using High-Efficiency Capillary GC Columns. Application. Authors. Abstract. Introduction

10/27/10. Chapter 27. Injector typically 50 C hotter than oven

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

TOTALLY INNOVATIVE MULTIMODE AUTOSAMPLER NEW KONIK ROBOKROM Laboratory Gas Generators An Overview +8 OPERATIONAL MODES MAIN FEATURES

Exercise in gas chromatography

Katherine K. Stenerson, Michael Ye, Michael Halpenny, Olga Shimelis, and Leonard M. Sidisky. Supelco, Div. of Sigma-Aldrich Bellefonte, PA USA

Transcription:

Selection of a Capillary GC Column - Series 3 Mark Sinnott Application Engineer March 19, 2009 Page 1

Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector Electrometer Air Hydrogen Carrier Gas Cylinders or Generators Flow Controller Column Recorder/ Integrator Picking the appropriate stationary phase and optimum dimensions for the column will give the greatest resolution in the shortest analysis time. Page 2

Four Primary Selection Areas Stationary Phase Type Column Internal Diameter Stationary Phase Film Thickness Column Length Page 3

Resolution N k R = α 1 s 4 k + 1 α Efficiency Retention Selectivity N = ƒ (gas, L, r c ) k = ƒ (T, d f, r c ) α = ƒ (T, phase) L = Length r c = column radius d f = film thickness T = temperature Page 4

Resolution N k R = α 1 s 4 k + 1 α Efficiency Retention Selectivity N = ƒ (gas, L, r c ) k = ƒ (T, d f, r c ) α = ƒ (T, phase) L = Length r c = column radius d f = film thickness T = temperature Page 5

Stationary Phase - Common Types Siloxane polymers Poly(ethylene) glycols Porous polymers Page 6

Capillary Column Types Porous Layer Open Tube (PLOT) Carrier Gas Solid Particles Wall Coated Open Tube (WCOT) Carrier Gas Liquid Phase Page 7

Stationary Phase Polymers H H HO - - C-C-O - H H - H n Polyethylene glycol backbone Page 8

Why Is Stationary Phase Type Important? Influence of α α = k2 k k1 k 2 = partition ratio of 2nd peak k 1 = partition t ratio of 1st peak Page 9

Selectivity Relative spacing of the chromatographic peaks The result of all non-polar, polarizable and polar interactions that cause a stationary phase to be more or less retentive to one analyte than another Page 10

Optimizing Selectivity Match analyte polarity to stationary phase polarity -like dissolves like(oil and water don t mix) Take advantage of unique interactions between analyte and stationary phase functional groups Page 11

Compounds - Properties Compounds Polar Aromatic Hydrogen Bonding Dipole Toluene no yes no induced Hexanol yes no yes yes Phenol yes yes yes yes Decane no no no no Naphthalene no yes no induced Dodecane no no no no Page 12

100% Methyl Polysiloxane (boiling point column?) 1 2 3 4 5 1. Toluene 110 o 2. Hexanol 156 o 6 3. Phenol 182 o 4. Decane (C10) 174 o 5. Naphthalene 218 o 6. Dodecane (C12) 216 o Strong Dispersion No Dipole No H Bonding 0 2 4 6 8 10 12 14 16 Page 13

5% Phenyl 5% Phenyl 1 2 3 4 5,6 Compounds Polar Aromatic Hydrogen Bonding Dipole Toluene no yes no induced Hexanol yes no yes yes Phenol yes yes yes yes Decane no no no no Naphthalene no yes no induced Dodecane no no no no Strong Dispersion No Dipole Weak H Bonding 100% Methyl 0 2 4 6 8 10 12 14 16? 1 2 3 4 5 6 Strong Dispersion No Dipole No H Bonding 1. Toluene 2. Hexanol 3. Phenol 4. Decane (C10) 5. Naphthalene 6. Dodecane (C12) 0 2 4 6 8 10 12 14 16 Page 14

50% Phenyl 1 2 4 3 6 5 50% Phenyl Compounds Polar Aromatic Hydrogen Bonding Dipole Toluene no yes no induced Hexanol yes no yes yes Phenol yes yes yes yes Decane no no no no Naphthalene no yes no induced Dodecane no no no no Strong Dispersion so No Dipole Weak H Bonding 100% Methyl 0 2 4 6 8 10 12 14 16? 1 2 3 6 Strong Dispersion 4 5 No Dipole No H Bonding 1. Toluene 110 o 2. Hexanol 156 o 3. Phenol 182 o 4. Decane (C10) 174 o 5. Naphthalene 218 o 6. Dodecane (C12) 216 o 0 2 4 6 8 10 12 14 16 Page 15

14% Cyanopropylphenyl Compounds Polar Aromatic Hydrogen Bonding Dipole Toluene no yes no induced Hexanol yes no yes yes Phenol yes yes yes yes Decane no no no no Naphthalene no yes no induced Dodecane no no no no 14% Cyano- propylphenyl 1 2 4 6 3 5 Strong Dispersion None/Strong Dipole (Ph/CNPr) Weak/Moderate H Bonding (Ph/CNPr) 100% Methyl 0 2 4 6 8 10 12 14 16? 1 2 3 6 Strong Dispersion 4 5 No Dipole No H Bonding 1. Toluene 2. Hexanol 3. Phenol 4. Decane (C10) 5. Naphthalene 6. Dodecane (C12) 0 2 4 6 8 10 12 14 16 Page 16

50% Cyanopropyl 6 4 2 1 50% Cyanopropyl 5 3 Compounds Polar Aromatic Hydrogen Bonding Dipole Toluene no yes no induced Hexanol yes no yes yes Phenol yes yes yes yes Decane no no no no Naphthalene no yes no induced Dodecane no no no no Strong Dispersion Strong Dipole Moderate H Bonding 100% Methyl 0 2 4 6 8 10 12 14 16? 1 2 3 6 4 5 Strong Dispersion No Dipole No H Bonding 1. Toluene 2. Hexanol 3. Phenol 4. Decane (C10) 5. Naphthalene 6. Dodecane (C12) 0 2 4 6 8 10 12 14 16 Page 17

100% Polyethylene Glycol Strong Dispersion Strong Dipole 4 1 Moderate H Bonding 6 2 100% PEG Compounds Polar Aromatic Hydrogen Bonding Dipole Toluene no yes no induced Hexanol yes no yes yes Phenol yes yes yes yes Decane no no no no Naphthalene no yes no induced Dodecane no no no no 5 3 100% Methyl 0 2 4 6 8 10 12 14 16? 1 2 3 6 Strong Dispersion 4 5 No Dipole No H Bonding 1. Toluene 2. Hexanol 3. Phenol 4. Decane (C10) 5. Naphthalene 6. Dodecane (C12) 0 2 4 6 8 10 12 14 16 Page 18

Selectivity is important but not everything Inertness and Bleed can be critical factors in column selection. Temperature limits will play a role as well. Page 19

Stationary Phase Bleed A thermodynamic equilibrium process that occurs to some degree in all columns, and is proportional to the mass amount of stationary phase inside the capillary tubing/carrier gas flow path Polysiloxane backbone releases low molecular weight, cyclic fragments Is negligible in low temperature, O2-free, clean GC systems Increased by increased temperature, oxygen exposure, or chemical damage Page 20

Bleed: Why Does It Happen? Back Biting Mechanism of Product Formation CH 3 CH 3 CH 3 CH 3 CH 3 CH 3 CH 3 Si O Si O Si O Si O Si O Si O Si OH H 3 C CH 3 Si HO O CH 3 CH 3 CH 3 CH 3 Si O Si O Si O Si O Si Si CH 3 CH 3 CH 3 CH 3 O CH 3 CH 3 CH3 CH 3 CH 3 CH 3 CH 3 CH 3 CH 3 CH 3 CH 3 CH 3 CH 3 CH 3 CH 3 H 3 C CH 3 Si Si O Si O Si O Si OH O O CH 3 CH 3 CH 3 CH 3 + CH H 3 C Si Si 3 O H 3 C CH 3 Cyclic products are thermodynamically more stable! Repeat Page 21

DB-5ms Structure CH O DB-5 Structure DB-5ms Structure 3Si CH CH 3 Si 3 O CH CH 3 3 O O Si CH 3 Si CH 3 O Si CH 3 CH 3 DB-5 5% Phenyl Si CH 3 CH 3 CH 3 CH 3 Si O CH 3 Si DB-5ms 1.Increased stability 2.Different selectivity 3O 3.Optimized i dto match hdb5 DB-5 Page 22

Difference in Selectivity Solid line: DB-5ms 30 m x.25 mm I.D. x.25 μm Dashed line:db-5 30 m x.25 mm I.D. x.25 μm Oven: 60 o C isothermal Carrier gas: H 2 at 40 cm/sec 1: Ethylbenzene 2: m-xylene 3: p-xylene 4: o-xylene Page 23

Four Types Of Low Bleed Phases Phases tailored to mimic currently existing polymers -Examples: DB-5ms, DB-35ms, DB-17ms, DB-225ms Phases unrelated to any previously existing polymers -Examples: p DB-XLB Optimized manufacturing processes -DB-1ms,, HP-1ms, HP-5ms Hand selected columns Page 24

Benefits of Low Bleed Phases PAH Sensitivity Using DB-35MS 1 2 3 4 5 6 7 8 Commercially Available 35% phenyl column DB-35MS 9 10 11 15 16 12 13 14 Benzo[ghi]perylene S/N = 15 Benzo[ghi]perylene S/N = 120 1. Naphthalene 2. Acenaphthylene 3. Acenaphthene 4. Fluorene 5. Phenanthrene 6. Anthracene 7. Fluoranthene 8. Pyrene 9. Benz[a]anthracene 10. Chrysene 11. Benzo[b]fluoranthene e e 12. Benzo[k]fluoranthene 13. Benzo[a]pyrene 14. Indeno[1,2,3,- c,d]anthracene 15. Dibenz[a,h]anthracene 16. Benzo[g,h,i]perylene 5 10 15 20 25 min. Columns: 30 m x 0.32 mm x 0.35 um. Carrier: H2, constant flow, 5 psi at 100 o C. Injector: 275 o C, splitless, 1 ul, 0.5-5ppm. Oven: 100 o C to 250 o C (5 min.) at 15 o C/min.,; then to 320 o C (10 min.) at 7.5 o C/min. Detector: FID, 320 o C. Page 25

Benefits of Low Bleed Phases DB-35ms vs Standard 35% Phenyl Benzo[g,h,i]perylene, 1ng 1400000 1200000 Standard 35% Phenyl 1000000 800000 600000 400000 200000 DB-35ms 10.00 12.00 14.00 16.00 18.00 20.00 22.00 Page 26

Higher Spectral Purity Abundance 150000 78 Scan 1118 (20.560 min): 3901004.D Abundance Scan 1138 (20.640 min): 3901004.D 276 140000 130000 120000 Standard 35% Phenyl 253 80000 70000 DB-35ms 110000 100000 60000 90000 80000 207 276 50000 70000 40000 60000 331 377 30000 50000 40000 138 274 207 20000 30000 78 50 135 315 346 377 20000 405 157 10000 96 10000 223 439 119 239 0 0 M/Z -> 50 100 150 200 250 300 350 400 M/Z -> 50 100 150 200 250 300 350 400 Page 27

Polarity vs Stability/Temperature Range Polarity Stability Temperature Range Page 28

Stationary Phase Selection Existing information Selectivity/Polarity it l it Critical separations Temperature limits Application designed Examples: DB-VRX, DB-MTBE, DB-TPH, DB-ALC1, DB-ALC2, DB-HTSimDis, DB-Dioxin, HP-VOC, etc. Choose the column phase that gives the best separation but not at the cost of robustness or ruggedness. Page 29

Resolution N k R = α 1 s 4 k + 1 α Efficiency Retention Selectivity N = ƒ (gas, L, r c ) k = ƒ (T, d f, r c ) α = ƒ (T, phase) L = Length r c = column radius d f = film thickness T = temperature Page 30

Resolution N k R = α 1 s 4 k + 1 α Efficiency Retention Selectivity N = ƒ (gas, L, r c ) k = ƒ (T, d f, r c ) α = ƒ (T, phase) L = Length r c = column radius d f = film thickness T = temperature Page 31

Column Diameter - Theoretical Efficiency Total Plates I.D. (mm) 5 m N ~ 112,000 0.05 n/m 23,160 10 m N ~ 112,000 20 m N ~ 112,000 30 m N ~ 112,000 0.10 0.18 0.20 0.25 0.32 0.45 11,580 6,660 5830 4630 3660 2840 k = 5 053 0.53 2060 Page 32

Different Column I. D. Equal Phase Ratios Column: DB-624 30 m, 0.53 mm, 3 m Carrier: Oven: Helium, 40(cm/sec) 65 C Injection: Split Detector: FID Column: DB-624 30 m, 032mm 0.32 mm, 18 1.8 m 0 5 10 15 20 Time (min) Page 33

PHASE RATIO (β) Film Thickness Column Dimensions Phase Ratio β 30 m x.53 mm x 3.0 μm 44 30 m x.32 mm x 1.8 μm 44 K C = k β β = r 2d f Page 34

Column Diameter and Capacity I.D. (mm) Capacity (ng) 0.05 1-2 0.10 6-13 018 0.18 25-5555 Like Polarity Phase/Solute 0.25 µm film thickness 0.20 35-70 0.25 80-160 032 0.32 110-220 0.45 600-800 0.53 1000-2000 Page 35

Column Diameter - Inlet Head Pressures (Helium) I.D (mm) Pressure (psig) 30 meters 0.05 275-400 0.10 90-130 018 0.18 30-45 0.20 25-40 0.25 15-25 032 0.32 10-20 Hydrogen pressures x 1/2 0.45 3-7 0.53 2-4 Page 36

Column Diameter and Carrier Gas Flow Lower flow rates: Smaller diameter columns Higher flow rates: Larger diameter columns Low flow rates : GC/MS High flow rates: Headspace, purge & trap Page 37

Diameter Summary If you decrease the inside diameter: Efficiency Resolution Pressure Increase Increase Increase Capacity Decrease Flow rate Decrease Page 38

Resolution N k R = α 1 s 4 k + 1 α Efficiency Retention Selectivity N = ƒ (gas, L, r c ) k = ƒ (T, d f, r c ) α = ƒ (T, phase) L = Length r c = column radius d f = film thickness T = temperature Page 39

Resolution N k R = α 1 s 4 k + 1 α Efficiency Retention Selectivity N = ƒ (gas, L, r c ) k = ƒ (T, d f, r c ) α = ƒ (T, phase) L = Length r c = column radius d f = film thickness T = temperature Page 40

Film Thickness and Retention: Isothermal Thickness (µm) Retention Change 0.10 0.40 0.25 1.00 1.0 4.00 3.0 12.0 5.0 20.0 Constant Diameter Normalized to 0.25 µm Page 41

Film Thickness and Resolution When solute k < 5 d f R (early eluters) or T When solute k > 5 (later eluters) d f or T R Page 42

Other Retention - Adsorption Analysis of Noble & Fixed Gases Using HP PLOT MoleSieve 2 4 5 Column: Carrier: Oven: Sample: HP-PLOT/MoleSieve 30 m x 0.53 mm x 50 m HP part no. 19095P-MS0 Helium, 4 ml/min 35 C(3min) to 120 C (5 min) at 25 C/min 250 l, split (ratio 50:1) 6 1 3 1.Neon 2. Argon 3. Oxygen 4. Nitrogen 5. Krypton 6. Xenon 2 4 6 8 Time (min) Page 43

Film Thickness and Capacity Thickness (µm) Capacity (ng) 0.10 50-100 025 0.25 125-250250 0.50 250-300 1 500-1000 3 1500-3000 0.32 mm I.D. Like Polarity Phase/Solute 5 2500-5000 Page 44

Film Thickness and Bleed More stationary phase = More degradation products Page 45

Film Thickness and Inertness 0.25 1.0 3.0 active inactive active inactive active inactive Page 46

Film Thickness Summary If you increase the film thickness: Retention Resolution (k<5) Increase Increase Resolution (k>5) Decrease Capacity Bleed Inertness Efficiency Increase Increase Increase Decrease Page 47

Resolution N k R = α 1 s 4 k + 1 α Efficiency Retention Selectivity N = ƒ (gas, L, r c ) k = ƒ (T, d f, r c ) α = ƒ (T, phase) L = Length r c = column radius d f = film thickness T = temperature Page 48

Resolution N k R = α 1 s 4 k + 1 α Efficiency Retention Selectivity N = ƒ (gas, L, r c ) k = ƒ (T, d f, r c ) α = ƒ (T, phase) L = Length r c = column radius d f = film thickness T = temperature Page 49

Column Length and Efficiency (Theoretical Plates) Length (m) n 15 69,450 30 138,900 60 277,800 0.25 mm ID n/m = 4630 (for k = 5) Page 50

Column Length and Resolution R α n α L Length X 4 = Resolution X 2 t α L Page 51

Column Length VS Resolution and Retention: Isothermal R=0.84 R=1.16 16 R=1.68 2.29 min 4.82 min 8.73 min 15 m 30 m 60 m Double the plates, double the time but not double the the resolution Page 52

Column Length and Cost 15m 30m 60m $ $ $ $ $ $ $ Page 53

Length Summary If you Increase Length: Efficiency Resolution Analysis Time Pressure Cost Increase Increase Increase Increase Increase Page 54

Summary - Four Primary Selection Areas Stationary Phase Type Column Internal Diameter Stationary Phase Film Thickness Column Length Page 55

Still Can t Decide Which Column to Use????? Call Us!!! TECHNICAL SUPPORT Agilent 1-800-227-9770 #4, #1 E-mail: gc_column_support@agilent.com Page 56