Fast Screening Methods for Beta Blockers by HPLC with Agilent Poroshell 120 Columns

Similar documents
Fast Screening Methods for Steroids by HPLC with Agilent Poroshell 120 Columns

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Fast Screening Methods for Analgesics and Non-Steroidal Anti-Inflammatory Drugs by HPLC

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

Analysis of Positional Isomers with Agilent Poroshell 120 PFP Columns

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Application Note. Abstract. Authors. Pharmaceutical. William J. Long Agilent Technologies, Inc Centerville Road Wilmington, DE USA

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

Modernizing the USP Monograph for Acetaminophen

Accurate quantification of oleanolic acid and ursolic acid in traditional chinese medicine

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

penta-hilic UHPLC COLUMNS

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

LC and LC/MS Column Selection Flow Chart

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

penta-hilic UHPLC COLUMNS

Value of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Application. Authors. Abstract. Introduction. Hydrocarbon Processing

Analysis of Beer by Comprehensive 2D-LC with the Agilent 1290 Infinity 2D-LC system

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Automated LC Method Development: Fundamentals and Columns, Hardware, and Software

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Comprehensive 2D-LC Analysis of Chinese Herbal Medicine

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Analysis of Saponins in Spine Date Seed using Agilent ZORBAX Solvent Saver HT (1.8 µm) Columns

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Using the Agilent 1290 Infinity II Multicolumn Thermostat with Extreme Temperatures and Flow Rates

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

The Agilent 1290 Infinity II Multi Method Solution

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

How proteins separate on reverse-phase HPLC

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

A Look at Agilent HPLC Columns Choices

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Application Note. Author. Abstract. Xinlei Yang Agilent Technologies Co. Ltd Shanghai, China

Determination of Enantiomeric Excess of Metolachlor from Chiral Synthesis using the Agilent 1260 Infinity Analytical SFC System

Analysis of Phthalates in Body Wash using Solid-Supported Liquid-Liquid Extraction

Measuring Drug-to-Antibody Ratio (DAR) for Antibody-Drug Conjugates (ADCs) with UHPLC/Q-TOF

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Too Polar for Reversed Phase What Do You Do?

New Product Update. HPLC Columns

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Application Note. Food. Abstract. Author

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Application Note. Abstract. Authors. Environmental

Your Reversed Phase Method

LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120

Separation of Structurally Similar Steroids on HALO C18 and PFP

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Reversed Phase Solvents

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

SAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Fast and Flexible Optimization of Modifier Concentrations Using an Agilent 1290 Infinity LC System with Blend Assist

Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

UPLC Method Development and Validation

HPLC method development using alternative selectivities

HPLC Method Development with Eclipse Plus: Standard Practices and New Columns. Agilent Technologies

Method Development with Modern HPLC Phases

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Agilent LC & LC-MS Cannabis Testing

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

Choosing Columns and Conditions for the Best Peak Shape

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

Automated method development using Agilent 1100 Series HPLC systems, Agilent ChemStation and ChromSword software. Application

William E. Barber, Ph.D. Applications Chemist October

Application. Introduction. Authors. Abstract. Hydrocarbon Processing

Routine MS Detection for USP Chromatographic Methods

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Automated Sample Preparation in Quality Control of Eye-Drop Formulation

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Transcription:

Fast Screening Methods for Beta Blockers by PLC with Agilent Poroshell Columns Application Note Pharma, Biopharma, and Clinical Author William Long Agilent Technologies, Inc. Introduction Beta blockers, or beta-adrenergic blocking agents, are a class of drugs used to treat hypertension and to manage cardiac arrhythmias after a heart attack. As beta adrenergic receptor antagonists, they diminish the effects of epinephrine (adrenaline) and other stress hormones. The first beta blocker was synthesized in 98 by Eli Lilly Laboratories, but in 96, the first clinically significant beta blockers, propranolol and pronethalol, were developed and used for the treatment of angina pectoris. Beta blockers block the action of epinephrine (adrenaline) and norepinephrine (noradrenaline), in particular, on b-adrenergic receptors, part of the sympathetic nervous system that mediates the fight-or-flight response. Three types of beta receptors are known, designated b, b, and b receptors. b -Adrenergic receptors are located mainly in the heart and in the kidney, b-adrenergic receptors are mainly in the lungs, gastrointestinal tract, liver, uterus, vascular smooth muscle, and skeletal muscle. b -Adrenergic receptors are found in fat cells [,]. Beta blockers can be abused in sports involving little physical activity, such as archery, to reduce cardiac contraction, heart rate, and coronary blood flow. They have, therefore, been included in the list of forbidden substances by the International Olympic Committee []. Selectivity is the most powerful tool to optimize separations in PLC. This parameter is changed by using different bonded phases, including C8, C8, polar embedded, and phenyl bonded phases, or by changing the mobile phase. In this work, Agilent Poroshell columns and the Agilent 6 Infinity Method Development Solutions were used to quickly evaluate method development choices for the analysis of beta blockers. The short column length and high efficiency provided short analysis times and rapid equilibration leading to fast investigations of selectivity [].

Experimental The Agilent Infinity Series LC Multi-Method Solution was used. This system consisted of: 6 Infinity Binary Pump (GB) 9 Infinity Thermostatted Column Compartment (G6C) 6 Infinity igh Performance Autosampler (G6E) 9 Infinity Diode-Array Detector (GA), equipped with mm MaxiLight cartridge flow cell G6 Single Quadrupole Mass Spectrometer. Methanol was used throughout as a strong solvent and was obtained from oneywell. Temperature was controlled at C, and flow rate was set at. ml/min. Agilent ChemStation version B.. was used to control the instrument and process the data. The compounds examined included nadolol, atenolol, alprenolol, acebutalol, pindolol, propranolol, metoprolol, and labetalol, which were all were purchased from Sigma Aldrich. Structures are shown in Figure. The pka of these basic compounds ranged from 8.8 to 9.. All samples were prepared at mg/ml in DMSO and were diluted in water to a final concentration of. mg/ml. The Agilent Infinity Series LC Multi-Method Solution is a highly flexible system that can be used for up to ( mm) columns. In addition, the Agilent ChemStation Method Scouting Wizard automates the setup of methods and sequences to screen the available combinations of columns, solvents, predefined gradients, and temperatures. In this work, Agilent Poroshell columns were used: Agilent Poroshell StableBond SB-C8,. mm,. µm (p/n 68-9) N O O C C Atenolol O C C Pindolol Agilent Poroshell EC-C8,. mm,. µm (p/n 69-9) Agilent Poroshell Bonus-RP,. mm,. µm (p/n 68-9) Agilent Poroshell Phenyl-exyl,. mm,. µm (p/n 69-9) The TCC was fitted with a 6 position/ port selection valve. This is a new Quick Change Valve mounted on a slide-out rail to make plumbing and maintenance more convenient. Port was connected to a StableBond C8 column, and port was connected to an EC-C8 column. Port was connected to a Bonus-RP column, port to a Phenyl-exyl column, and port 6 to a bypass connecting capillary. The solvent passing into each column was heated using of individual low-dispersion heat exchangers. An additional -solvent selection valve was connected to valve position A on the 6 Infinity Binary pump. Together with the internal solvent selection valve of the 6 Infinity Binary pump, up to solvents could be screened using this system. The mobile phase was methanol and mm ammonium formate titrated to p.8 with formic acid. Water was used as a final weak solvent and to rinse the modifiers from the columns and allow proper column storage. Ammonium formate and formic acid were purchased from Sigma. Milli-Q 8 MW water was used. CO O O Nadolol Alprenolol Metoprolol O O O C C C Figure. Structures of some beta blockers. O O Propranolol O Acebutolol O C C C Samples prepared at mg/ml in DMSO diluted in water to a final concentration of. mg/ml

Column Choice to Enhance Selectivity The columns were chosen to improve selectivity in the separation. They included a highly end capped column recommended as a first choice in method development (Poroshell EC- C8); a non end capped C8 (Poroshell StableBond SB-C8) that could have interaction with silanol groups, providing an alternative C8 selectivity using neutral to low p mobile phases; a polar embedded amine column (Poroshell Bonus-RP), and a phenyl-hexyl column (Poroshell Phenyl-exyl). Phenyl bonded phases are known for their improved selectivity for aromatic compounds. A polar-embedded group inserted into the hydrophobic C alkyl chain allows the Bonus-RP phase on totally porous Poroshell to minimize interaction of polar samples with silanols, providing symmetrical peaks for a wide variety of applications. This phase is especially useful at neutral p where amines can interact strongly with ionized silanols. The polar-embedded group also helps to wet the hydrophobic chains and prevents phase collapse in highly aqueous mobile phases. Poroshell Bonus-RP can be used for many of the same separations as a C8 column while avoiding some of the disadvantages of C8, such as poor wettability in high aqueous mobile phases. In addition, it is much more retentive for those molecules that can interact by hydrophobic interactions and also by -bonding with the amide group. Compared to alkyl only phases, Bonus-RP has enhanced retention and selectivity for phenols, organic acids, and other polar solutes due to strong -bonding between polar group (-bond acceptor) and -bond donors, like phenols and acids. Bonus-RP gives retention slightly less than a C8 allows for easy column comparison without the need to change mobile phase conditions. The Bonus-RP phase gives different selectivity than C8 for polar compounds. It is also compatible with % water. The Phenyl-exyl phase has unique reversed-phase selectivity, especially for polar aromatics and heterocyclic compounds, derived from analyte interaction with the aromatic ring of the bonded phase and its delocalized electrons. Poroshell Phenyl-exyl can be orthogonal to both C8 and Bonus-RP phases. More retention and selectivity will often be observed for solutes with aromatic electron-withdrawing groups such as fluorine or nitro groups [,6]. Poroshell Phenyl-exyl columns deliver unique selectivity for compounds with aromatic groups providing superior resolution for these samples. Poroshell Phenyl-exyl can also provide optimum separations of moderately polar compounds where typical alkyl phases (C8 and C8) do not provide adequate resolution Acetonitrile tends to decrease the p p interactions between aromatic and polarizable analytes and the phenyl-hexyl stationary phases, but methanol enhances those same interactions, giving both increased retention and changes in selectivity []. This does not mean that acetonitrile should not be used with a phenyl bonded phase or that it might not provide an acceptable separation, but methanol is more likely to deliver the additional selectivity that is desired from a phenyl phase.

Results and Discussion As can be seen in Figure, the separation of all compounds was accomplished on all columns surveyed. The Poroshell EC-C8 column showed very close elution of acebutanol and propranolol and a double peak with the same molecular ion for naldolol. The double peak for nadolol was attributed to a diastereomer. The Poroshell SB-C8 column delivered almost the same separation. This was not found with the Poroshell Bonus-RP column, as it tended to minimize secondary interactions. The Poroshell Bonus-RP column also reversed peaks 6 and (propranolol and alprenolol), compared to the C8 columns. The Poroshell Phenyl-exyl column shared this 6, peak reversal and additionally reversed peaks and (metoprolol and acebutolol). The separation was similar to that shown by the other C8 columns but was not as retentive..atenolol. Pindolol. Naldolol. Metoprolol. Acebutolol Mixture of Beta Blockers mm p.8 N CO, Methanol 6. Propranolol. Alprenolol 6 Poroshell Bonus RP - 6 8 min Poroshell Phenyl exyl 6-6 8 6 Poroshell EC-C8-6 8 6 Poroshell SB-C8-6 8 9% B to % B over min,. ml/min, all columns. mm Figure. Separation of beta blockers using Agilent Poroshell columns. min min min

Conclusions Analysis problems can be quickly resolved by including survey methods with generic gradients as part of the method development scheme. This work uses beta blockers as an example, and shows how phases with different selectivity can be used to optimize the separation. While the Poroshell EC-C8 and SB-C8 columns provide adequate separation, using an alternative selectivity column, such as Poroshell Bonus-RP, yields even better results and can be used for several thousand samples. Automatic setup of methods and sequences for the Poroshell columns was straightforward using the Agilent Infinity Series LC Multi-Method Solution. Bibliography. N. Freemantle, J. Cleland, P. Young, J. Mason, J. arrison. "Beta Blockade after myocardial infarction: systematic review and meta regression analysis". BMJ 8 (): (June 999).. J.M. Cruickshank. "Beta blockers in hypertension". Lancet 6 (99): (August ).. J. Zhanga, L. Ding, A. Wen, F. Wua, L. Suna, L. Yang. Asian J. Pharma Sci., 69 (9).. L. R. Snyder, J. J. Kirkland, J. L. Glajch. Practical PLC Method Development. Wiley-Blackwell, New York (99).. C. Markopoulou, T. Tweedlie, D. Watson, G. Skellern,. Reda, P. Petersson,. Bradstock, M. Euerby. Chromatographia., (9). 6. G. P. O'Sullivan, N. M. Scully, J. D. Glennon. Anal. Lett., ().. N. S. Wilson, J. Gilroy, J. W. Dolan, L. R. Snyder. J. Chromatogr. A. 6, 9 (). For More Information These data represent typical results. For more information on our products and services, visit our Web site at www.agilent.com/chem.

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., Printed in the USA June, 99-9EN