Why teach with a laboratory microwave?

Similar documents
INNOVATIVE ENGINEERING FOR SIMPLE OPERATION

INNOVATIVE ENGINEERING FOR SIMPLE OPERATION

IT DOESN T GET ANY EASIER THAN THIS!

MICROWAVE. Synthesis MANUAL REACTORS AUTOMATED WORKSTATIONS FLOW SYSTEMS SCALE UP SYSTEMS PARALLEL SYNTHESIS TEACHING SOLUTIONS

l 4-minute cycle time l 90% solvent reduction Remarkably fast Automated Microwave Peptide Synthesizer

DO I REALLY NEED TO USE MICROWAVE TECHNOLOGY? IF YOU WORK WITH ANY TYPE OF CHEMICAL SYNTHESIS OR CHEMICAL REACTION, THE ANSWER IS YES!

ORACLE. FIRST EVER RAPID FAT ANALYZER with No Method Development

MARS 6 Batch Microwave Acid Digestion System

H E L P I N G C H E M I S T S. StartSYNTH. Microwave Synthesis Labstation

Sample Preparation of Electronic Device Components for Hexavalent Chromium Analysis by IEC Method :2017

Analyze... Cheese. Ice Cream. Sour Cream. Yogurt. Butter. Margarine. Deboned Poultry. Beef. Condiments. Cookies. Crackers. Snack Foods. and more...

Perseverance. Experimentation. Knowledge.

H E L P I N G C H E M I S T S. UltraCLAVE. The Next Generation Microwave Digestion System

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

THE GAME CHANGER IN MICROWAVE SYNTHESIS MILESTONE

Metz Syn 10 Reaction Station

An automated synthesis programme for drug discovery

THE NEW MILESTONE MILESTONE

High Pressure Chemistry. Hydrogenation & Catalysis Tools.

Liberty Blue TM Automated Microwave Peptide Synthesizer. Manual

Focus Series Peptide Synthesizers

Your partner in Science!

MILESTONE MILESTONE ETHOS EASY. Advanced Microwave Digestion System

TA Instruments NEW AR-G2 INTRODUCING THE WORLD S FIRST MAGNETIC BEARING RHEOMETER! The World Leader in Thermal Analysis and Rheology Systems

Microwave Synthesis Solutions. ::: Excellence in Microwave Synthesis

DI 3500 Discrete Aoalvzer

Introduction to Fourier Transform Infrared Spectroscopy

Product Information. Silicon Carbide Well Plates

Focus XC + 6 Microwave capability = Infinity Explore Infinite Possibilities. with the Infinity Microwave Peptide Synthesizer

Microwave Synthesis Fourth generation systems

Agilent Cary 630 FTIR Spectrometer Supporting Organic Synthesis in Academic Teaching Labs

Process Safety. Process Safety and Hazard Assessment Avoiding Incidents in the Lab and in the Plant

Level. Automate your processes Automate your lab Innovate with. sensing. EasyPREP. sample handler. Automated Sample Preparation.

POLYPHOSPHORIC ACID ASSAY

AppNote 5/2008. Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

Thermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

CHEMISTRY Organic Chemistry Laboratory II Spring 2019 Lab #1: Oxidation of Alcohols to Ketones - Borneol Oxidation (2 weeks)

Experiment C-15 Distillation - part 1

Modulyzer. Multiparameter Measuring Systems. ::: Unique Density & Concentration Meters

Biotage 2012 Webinar series

calorimeter heat flow calorimetry, power compensation calorimetry

Automated pipetting made easy new ep Motion 5073 family members for perfect PCR set-up and nucleic acids purifi cation or general liquid handling

Introduction to Fourier Transform Infrared Spectroscopy

The Fundamentals of Moisture Calibration

IN QUALITATIVE ANALYSIS,

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

FORCE TENSIOMETER K100 THE HIGH-END SOLUTION FOR MEASURING SURFACE AND INTERFACIAL TENSION

Larger Display Easier to Use. Generation E. Repeater E3 and E3x: Dispense without compromising accuracy or precision

RheolabQC. Rotational Rheometer for Quality Control. ::: Intelligence in Rheometry

10 REASONS THAT THE ZETASIZER NANO IS CHOSEN FOR SCIENTIFIC SUCCESS

University Wet Chemistry Analyzer Packages

Kjeltec 2300 Analyzer Unit

Advancer Kilobatch. kilogram scale-up of all microwave chemistry

Multi-element process analyzer

CHEMICAL REACTORS TEACHING EQUIPMENT CEXC

IMPROVED ADIABATIC CALORIMETRY IN THE PHI-TEC APPARATUS USING AUTOMATED ON-LINE HEAT LOSS COMPENSATION

Clean, Fast Organic Chemistry

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

Week 10 Chemical Synthesis

Dewpoint Meter Data Sheet / Instructions

LABSONIC The convenient ultrasonic homogenizer for your laboratory

on TM 2012 KinetiChem, Inc. Irvine, CA Jeffrey C. Raber, Ph.D.

SOPHAS - Speeding up the process of discovery and optimisation

XBC300 Gen2. Fully-automated debonder and Cleaner

Elcometer 116A. Whirling Hygrometer. Operating Instructions

Supplementary Information

Now also in Eppendorf LoBind. Conical Competence. Eppendorf Conical Tubes 15 ml and 50 ml

Data Sheet / Instructions. Dewpoint MeterO

10/18/2006. Biotage A Life Science Technology Company

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

CyFlow Ploidy Analyser & CyFlow Space High-resolution DNA analysis

Reaxys Improved synthetic planning with Reaxys

C80. Calvet Calorimeter From ambient to 300 C. A trademark of KEP Technologies group

Recent Advances to Improve Chemical Development

473 Dew Point Hygrometer

UDK. Distillation Units Series. A Full Range of Solutions for Kjeldahl Distillation LABSOLUTIONS

How do you explain HPLC? 2 AZURA Educational System for tomorrow s HPLC professionals

FORCE TENSIOMETER K100 THE HIGH-END SOLUTION FOR MEASURING SURFACE AND INTERFACIAL TENSION

473-SHX Dew Point Mirror

Particle Analysis at the Touch of a Button. Litesizer series

Manufacturing process control with PAT Substitution of off-line HPLC & GC by in-line IR spectroscopy

SIFT-MS. technology overview

Everyday NMR. Innovation with Integrity. Why infer when you can be sure? NMR

Experiment 7: The Synthesis of Artificial Hyacinth Odor (1-bromo-2-phenylethene), Part I

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

PhysioCare Concept improved. The feeling of a new philosophy

CHEM 2240L Final Exam Review Topics

Electronic Supplementary Information

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

PhysioCare Concept improved. The feeling of a new philosophy

Best selling products overview of company AURA a.s.

NEW! PCR next to me. Eppendorf Mastercycler nexus: combine, connect, control

Microwave Irradiation

BP1 PONA BPX1. GC Capillary Columns BP1 PONA and BPX1

DSA 5000 M. Density and Sound Velocity Meter. ::: Unique Density & Concentration Meters

For purification/separation of organic and aqueous phases from a two phase mixture within a 96 or 24 array tube system

FlowCAT a versatile continuous flow reactor system focusing on reactions under elevated pressure and/or involving heterogeneous catalysis.

RH7-D & RH10-D CAPILLARY RHEOMETERS

CRYSTA-APEX C. The modular system for 3D CNC coordinate measurement in the production environment. Quick, versatile and high performing.

Transcription:

Why teach with a laboratory microwave? Bring real world experience into the teaching laboratory with state-of-the-art tools like the ones your students will encounter in graduate school and the workplace. Perform reactions 10 1,000 times faster than conventional heating Microwave heating allows students to complete purification and analysis in the same lab period. The shortened reaction time also provides them with the opportunity to perform difficult or multi-step syntheses in the undergraduate lab. Achieve greater yields and increased purities Microwave energy transfers to the reactants rapidly, giving side reactions very little opportunity to form and resulting in greater yields of the target product. Implement green chemistry principles Microwave reactions use less solvent than conventional reactions, and in some chemistries, less hazardous solvents or even water may be used and still produce great results. Enhance the safety of your lab Laboratory grade microwave systems provide monitoring and feedback control of temperature, pressure, and stirring to ensure maximum safety and reproducibility in the lab. CONVECTIVE HEATING MICROWAVE HEATING Energy is transferred indirectly to the reactants by applying heat to the outside surface of the vessel. This form of heating is very slow and inefficient. Since the vessel wall is virtually transparent to microwaves, energy is directly absorbed by the reaction, providing instantaneous activation or localized superheating of the molecules in solution. This direct molecular activation limits side reactions and provides a fast and efficient form of heating. Microwave vs. Conventional Reflux Heating for Organic Experiments Experiment Type Reflux conditions Microwave conditions Diels-Alder 90 minutes in DMF 10 minutes in H 2 O Williamson Ether Synthesis 60 minutes in H 2 O 10 minutes in H 2 O Aldol Condensation 23 hours in H 2 O 15 minutes in H 2 O Bromination 45 minutes in HOAc 8 minutes in HOAc Nucleophilic Aromatic Substitution 60-90 mins in Toluene 10 minutes in EtOH / H 2 O Hydrolysis 34 hours in MeOH / H 2 O 9-15 minutes in MeOH / H 2 O

Microwave Solutions for Your Lab CEM offers two microwave platforms for synthetic chemistry: the MARS 6 and the Discover SP. The MARS 6 is a parallel reactor designed for batch processing of reactions. The ability to run multiple reaction vessels simultaneously is advantageous for large teaching laboratories, as it only takes 30 minutes to complete a set of 24 vessels. The Discover SP is a sequential system, which is best suited for a smaller class size, but can be utilized in a larger lab section where students work in groups. The advantage of the Discover SP for the teaching environment is that sequential processing of reactions minimizes the backlog on other equipment. Nucleophilic Aromatic Substitution Complete in 10 minutes or less in the microwave! Solvent Reagents Microwave Reaction Vessels Ethanol 1-Bromo-2,4-dinitrobenzene Ethylamine Reaction Time Cool-down Time (70% aqueous) MARS 6 24 5 ml 0.298 g 0.380 ml 10 minutes 20 minutes Discover SP 12 3 ml 0.298 g 0.380 ml 6 minutes 2 minutes *Leadbeater, N. E.; McGowan, C. B. Clean, Fast Organic Chemistry: Microwave-assisted laboratory experiments. 2006, CEM Publishing. MARS 6 The best-selling MARS 6 is a multimode microwave system that provides parallel reaction processing, making it ideally suited for teaching laboratories. With the ability to accommodate up to 36 pressurized vessels or up to a 5 L open flask, the MARS 6 offers both high-throughput for larger lab sections and flexibility to run batch syntheses. In addition to accommodating synthetic chemistry, the MARS 6 can also be used for solvent extraction and acid digestion for metals analysis. Discover SP The Discover SP is a single mode, sequential microwave system which allows significant flexibility in the teaching lab, as students can explore different reaction parameters and work with various substrates and solvents. The sequential format is ideal for classes of 12 students or less, but also fits in classes with a larger number of students who work in groups. The Discover SP is the system of choice for research laboratories performing initial investigative syntheses and chemistry optimization with a variety of accessories available, including automation decks.

Teaching A State of the Art Microwave Synthesis System for Your Laboratory Features 1800 WATTS DELIVERED ENERGY Highest available power for rapid heating of reactions regardless of the number of vessels in the cavity LARGEST MICROWAVE CAVITY Allows for the greatest range of reaction vessels Up to 36 pressurized vessels Up to a 5 L open flask RUGGED, HIGH-GRADE 316 SOLID-STEEL CAVITY Multi-layer Teflon coating provides maximum protection against corrosion HEAVY-DUTY, SPRING-MOUNTED, PRESSURE RELIEVING DOOR WITH SAFETY INTERLOCKS SOLVENT- AND IMPACT-RESISTANT COMPOSITE SHELL Superior system protection from a laboratory environment than painted metal wraps SPECIALLY DESIGNED CAVITY & WAVEGUIDES Ensures uniform distribution of microwave energy without need of a mode stirrer HIGH-RESOLUTION, FULL COLOR TOUCHSCREEN WITH SPEAKERS No need for a laptop or external controller INTUITIVE SOFTWARE CONTROL Quickly program new methods, load existing methods, and recall run data FIBER OPTIC AND IR TEMPERATURE CONTROL AVAILABLE SAFETY CONTROLS Sensor and feedback monitoring to prevent vessel events for maximum operator safety 8 GIGABYTE MEMORY Ample data storage space CONNECTIVITY Available ports: 5 USB, 1 USB-B, 2 Ethernet, and1 RS-232 ONBOARD TRAINING VIDEOS Learn how to properly assemble vessels and operate a MARS 6

Vessel Type Vessel Options for the MARS 6 Synthesis System Max. number of vessels per run Volume Max. Temp. ( C) Materials of Construction Open flask 1 Up to 5 L Reflux Glass Enhanced stirring for homogenous sample mixing. GlassChem TM 24 or 36 20 ml 180 Glass GreenChem TM 14 100 ml 200 Teflon or Glass EasyPrep TM 12 100 ml 300 Teflon Atmospheric Pressure Vessel Kit Each kit includes a 3 L and a 5 L vessel. Also included are extenders, adapters (specific to each vessel) and a vessel stand. The adapters side port allows for placement of the temperature probe in the reaction vessel to control the reaction conditions. 5 L Vessel 3 L Vessel GlassChem Vessels The GlassChem TM vessels are engineered with a simple screw cap design for ease of use while still providing the temperature and pressure capabilities necessary to perform a full range of experiments in the teaching lab. Reinforced composite sleeves surround each individual vessel, protecting the cavity and user for maximum safety. A Teflon turntable shield ensures the vessels are properly seated and secured throughout the run. GlassChem 20 ml vessel with Stir Bar GlassChem 20 ml control vessel This simple to use vessel permits reaction conditions of up to 180 C and 200 psi. It is designed for undergraduate teaching as well as research. These vessels are available in starter kits of 8, 16, 24, or 36 vessels. Each kit includes a control vessel to provide precise control of reaction conditions.

Teaching & Research Advanced Microwave Technology for Greater Flexibility Features 300 WATTS OF FOCUSED ENERGY Efficient power delivery for maximum reaction control SELF-TUNING WAVEGUIDE Adjust for changing chemical properties to optimally heat sample ACTIVENT PRESSURE RELIEF Programmable reaction venting to release gaseous byproducts and reduce vessel failures VOLUME-INDEPENDENT TEMPERATURE MEASUREMENT Reduces the number of vessels needed to accommodate a large working volume 300 ml MICROWAVE CAVITY Large cavity provides unprecedented access and vessel flexibility WORKING VOLUME 0.2 50 ml pressurized 0.2 75 ml reflux POST-REACTION COOLING Rapidly quench reactions upon completion SOFTWARE & KEYPAD CONTROL Intuitive Synergy software and backup control AUTOMATION Allows unattended operation and prevents down-time between reactions EASIEST-TO-USE VESSELS Snap-on caps No tools needed for assembly ACCESSORIES Provides the utmost flexibility in chemistry exploration 80 ml pressurized glass vessel for scale up Continuous flow cells Camera for real-time reaction viewing Gas addition for reactions with gaseous reagents Low temperature reactions (as low as -80 C) Automation decks Fiber optic temperature monitoring 10 ml 35 ml

Fiber Optic Temperature Control Fiber Optic Temperature Control provides the most precise temperature measurement available by directly measuring the temperature inside the reaction vessel. It can be used with 10 ml or 80 ml reaction vessels designed for this purpose, as well as with the 80 ml vessel. Other accessories, including the CoolMate and Gas Addition Kit use this type of temperature measurement. Open Vessel Reactions Discover SP is the only single-mode microwave synthesis system capable of also performing open vessel reactions using standard laboratory glassware and condensers. Discover SP accepts up to a 125 ml round-bottom flask and allows reagent addition and overhead stirring. It can be used with or without a reflux condenser. Temperature can be measured using either the builtin IR sensor or the optional Fiber Optic Tempreature Control. Resources at Your Fingertips Whether you re teaching general chemistry, organic, inorganic, quantitative analysis, or an advanced course, we have the resources to help you every step of the way. Teaching Manuals Microwave Experiments Books on Microwave Chemistry Application Notes Reference Lists And more! Use round-bottom flask up to 125 ml Open Vessel Attenuator Visit us online today at www.cem.com/academic. Advantages of Open Vessel: Use standard glassware Work on a larger scale No risk of pressure build-up Easy access to reaction for reagent addition or reaction sampling Use of overhead stirring for viscous mixtures Scan to visit our Academic Resource Center.

Why choose CEM? CEM Corporation PO Box 200 Matthews, NC 28106 Tel: 800-726-3331 Tel: 704-821-7015 Fax: 704-821-7894 Email: info@cem.com www.cem.com We can help As the leading provider of microwave laboratory systems in the world, we have more than 35 years of experience designing and manufacturing products of superior quality, performance, and reliability. Our applications chemists and service engineers are well known for their expert and timely assistance, ensuring that laboratories using CEM instruments are always running the chemistry needed to get results, fast. Your partner in academic research and teaching CEM is a company driven by scientists and their vision. We understand the challenges facing today s academic community and we are committed to supporting educational initiatives aimed at helping students and professors achieve outstanding results in their laboratory. Resources at your fingertips Whether you re teaching general chemistry, organic, inorganic, quantitative analysis or an advanced majors course, we have the microwave system and resources you need to get started today. Have questions? Contact us! We can help you determine which system would be right for your research. Toll-free: (800) 726-3331 [USA & Canada] Phone: (704) 821-7015 info@cem.com www.cem.com France CEM μwave S.A.S. Immeuble Ariane Domaine Technologique de Saclay 4, rue Rene Razel 91892 ORSAY Cedex Tel: (33-01) 69 35 57 80 Fax: (33-01) 60 19 64 91 Email: info.fr@cem.com www.cemfrance.fr Germany, Austria, & Switzerland CEM GmbH Carl-Friedrich-Gauss-Str.9 47475 Kamp-Lintfort Tel: (49) 2842-9644-0 Fax: (49) 2842-9644-11 Email: info@cem.de www.cem.de Ireland CEM Technology (Ireland) Ltd. Sky Business Centre 9a Plato Business Park Damastown Dublin 15 Tel: +353 (0) 1 885 1752 Fax: +353 (0) 1 885 1601 Email: info.ireland@cem.com www.cemmicrowave.co.uk Italy CEM S.R.L. Via Dell Artigianato, 6/8 24055 Cologno al Serio (Bg) Tel: (39) 35-896224 Fax: (39) 35-891661 Email: info.srl@cem.com www.cemmicroonde.it Japan CEM Japan K.K. 2-18-10 Takanawa Minato-ku, Tokyo 108-0074 Tel: +81-3-5793-8542 Fax: +81-3-5793-8543 Email: info@cemjapan.jp www.cemjapan.co.jp Teflon is a registered trademark of DuPont. Discover, Explorer, and CEM are registered trademarks of CEM Corporation. MARS, Discover SP, ActiVent, Synergy, PowerMAX and CoolMate are trademarks of CEM Corporation. 2013 CEM Corporation ISO 9001:2008 ISO 900 1:200 8 CEM has been an ISO-certified facility since 1994. United Kingdom CEM Microwave Technology Ltd. 2 Middle Slade Buckingham Industrial Estate Buckingham MK181WA Tel: (44) 1280-822873 Fax: (44) 1280-822342 Email: info.uk@cem.com www.cemmicrowave.co.uk B052.8