INSTRUCTION MANUAL RS 51 & RS 52 DIGITAL THERMOMETER

Similar documents
DIGITAL THERMOMETER OPERATOR S MANUAL

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Acceleration/Velocity/Displacement VIBRATION METER

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

VIBRATION METER. Instruction Manual.

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

T h e rm i s t o r s

MODEL: MO Digital DC Milliohm Meter OPERATING INSTRUCTION

Operating Instructions for Digital Manometer. Model: MAN-SD

Analog - Digital multimeters

Model 5060 GAUSS / TESLA METER

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

Model HHG 21 GAUSS / TESLA METER

Today s Weather 24 Hour Forecaster

Microcare LCD Solar MPPT User Documentation

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

Metallized polyester film capacitors MKT 470

Manual Dew point scanner PCE-DPT 1

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

Instruction Manual SEFRAM Thermal Camera

Dual laser + type K thermometer INFRARED THERMOMETER

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

Nixie Clock Manuela Desktop. User Manual

INF195 Infrared Thermometer

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

RADIATION-METER TM-91/TM-92

Dielectric Analysis of Insulation Liquids

Requirements to perform accurate dielectric material analysis

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

Route and retain the clinometer cable so that it does not interfere with moving parts where the unit is mounted.

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

symphony Reference Electrodes

E8EB-N0C2B E8EB-N0B2B

Instruction Manual HI Refractometer for Invert Sugar Measurements

User Manual VX4750 Function Generator Module

INSTRUCTION MANUAL FOR PORTABLE DIGITAL INFRARED RADIATION THERMOMETER IRT-200-HS

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

INFRARED THERMOMETER Model : TM-959

PHYS320 ilab (O) Experiment 2 Instructions Conservation of Energy: The Electrical Equivalent of Heat

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

792A AC/DC Transfer Standard

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

PTA-427 BAROMETRIC PRESSURE TRANSDUCER OPERATOR S MANUAL

PHOENIX CONTACT - 04/2016. Features

Prosperity Dielectrics Co., Ltd. 1 ACS-1045 Rev15

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

CR10TCR THERMOCOUPLE REFERENCE

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

Anemometer Thermometer Hygrometer

QUANTUM CONCEPT. Swimming User s Manual

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

CR10XTCR THERMOCOUPLE REFERENCE

Rapid RH Portable ph Meter. User's Manual

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

HIGH POWER THICK FILM CHIP FIXED RESISTOR

DATA SHEET POSITIVE TEMPERATURE COEFFICIENT AC/DC POWER SUPPLY SMD0603 series

American Zettler AZ742 RELAY Datasheet

792A AC/DC Transfer Standard

50 Gordon Drive, Rockland, Maine sherplows.com. STORM BOXX Snowplow. 10' and 12' Box Plow for Backhoe Loaders

symphony Multisensor Probes

Dielectric Analysis of Solid Insulations

Mini Environmental Quality Meter

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

Portable ph/orp/ion Meter D-73 Instruction Manual CODE:GZ A

INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

MULTILAYER CERAMIC CAPACITORS

Multilayer Ceramic Chip Capacitors

Interference suppression film capacitors MKP 336 1

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

OP-02 / OP-03 / OP-04

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

Critical parameters of

50 TZV 1500 M JDE VB 18X21.5

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

Bright Advance Corporation

INE-DDB-303A Portable Conductivity Meter Instruction Manual

473 Dew Point Hygrometer

Installation guide 862 MIT / MIR

EVERLIGHT ELECTRONICS CO.,LTD.

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

473-SHX Dew Point Mirror

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

ShowCUBE. ShowCUBE DMX RGBWA+UV Eternal Lighting Updated 01/2015

Field Pro Operation and Installation Manual

WS-7038U Wireless 433 MHz Miniature Rain Monitor. Instruction Manual

INSTRUCTION MANUAL Milwaukee Refractometer MA872 Refractometer for Fructose Measurements

Transcription:

INSTRUCTION MANUAL RS 51 & RS 52 DIGITAL THERMOMETER EN FR IT DE

RS 51 & RS 52 DIGITAL THERMOMETER INSTRUCTION MANUAL

2

INTRODUCTION 1-1 Unpacking and Inspection Upon removing your new Digital Thermometer from its packing, you should have the following items: 1. Digital Thermometer. 2. K-type Bead Thermocouple. 3. Operator's Manual. 4. Protective Holster. 5. Belt Clip. 1-2 Front Panel Refer to Figure 1 and the following numbered steps to familiarise yourself with the meter's front panel controls and connectors. 1. Digital Display The digital display has a 3-1/2 digit LCD readout (maximum reading 1999) auto polarity decimal point, "<", function symbol and unit annunciators. 2. Thermocouple Connectors Allows connections of miniature thermocouple plugs (2 for model 52). 3

3. Hold Switch Used to hold the numeric reading. When pressed the HOLD annunciator is displayed. Conversions are made but the reading is not updated. This switch is limited to use on a single temperature scale at a time. 4. Power ON/OFF Switch Turns the thermometer on or off. 5. Resolution Selector Selects either 0.1 or 1 degree resolution. 6. C F Selector Used to select the C and F units. 7. Max. Switch Press once to display the max. reading in measurements, press again to cancel. Disable this function before changing control keys to keep reading correctly. This switch is limited to use on a single temperature scale at a time. 8. T1-T2 Switch Selects the T1-T2 mode for measuring (52 only). 9. T2 Switch Selects the T2 mode for measuring (52 only). 10. T1 Switch Selects the T1 mode for measuring (52 only). 4

2 1 3 4 5 6 7 8 9 10 Figure 1 5

SPECIFICATIONS 2-1 General Specifications This Thermometer conforms to the temperature / voltage tables of the National Bureau of Standards and to the IEC Standards for K-type. Display : 3 1/2 digit Liquid Crystal Display (LCD) with a maximum reading of 1999. Polarity Indication : Automatic, positive implied, negative indicated. Overrange Indication : "OL" or "-OL". Low Battery Indication : " < " is displayed when the battery voltage drops below operating voltage. Sampling Rate : 2.5 time / sec. 6

2-2 Environmental Conditions Operating Temperature : 0 C to 50 C, 0 to 75% R.H. Storage Temperature : -20 C to 60 C, 0 to 80% R.H with battery removed from meter. Temperature Coefficient : 0.15 x (Specified accuracy) / C, < 18 C or > 28 C. Power Requirements : 9V alkaline battery. Battery Life : Alkaline 250 hours. Dimensions (H x W x D) : 160mm x 64mm x 26mm without holster. 170mm x 74mm x 39mm with holster. Weight (including battery) : 300 gms without holster. 430 gms with holster. Accessories : 2 K-type bead thermocouples (52), 1 K-type bead thermocouple (51) battery (installed), operator's manual and protective holster. 7

2-3 Electrical Specifications (1) Accuracy is ± (% reading + number of digits) at 23 C ± 5 C less than 75% R.H for thermometer. MODEL: 51 Measurement Range Resolution Accuracy Input Protection -50 C ~ 199.9 C 0.1 C ± (0.2% reading + 1 C) -58 F ~ 199.9 F 0.1 F ± (0.2% reading + 2 F) -50 C ~ 200 C 1 C ± (0.3% reading + 2 C) -58 F ~ 392 F 1 F ± (0.3% reading + 4 F) 200 C ~ 1000 C 1 C ± (0.4% reading + 2 C) 60V d.c. or 24 Vr.m.s. 392 F ~ 1832 F 1 F ± (0.4% reading + 4 F) 1000 C ~ 1300 C 1 C ± (0.6% reading + 2 C) 1832 F ~ 1999 F 1 F ± (0.6% reading + 4 F) 8

MODEL: 52 Measurement Range Resolution Accuracy (T1 or T2) Accuracy (T1 T2) -50 C ~ 199.9 C 0.1 C ± (0.2% reading + 1 C) ± (0.5% reading + 1 C) -58 F ~ 199.9 F 0.1 F ± (0.2% reading + 2 F) ± (0.5% reading + 4 F) -50 C ~ 200 C 1 C ± (0.3% reading + 2 C) ± (0.5% reading + 2 C) -58 F ~ 392 F 1 F ± (0.3% reading + 4 F) ± (0.5% reading + 4 F) 200 C ~ 1000 C 1 C ± (0.4% reading + 2 C) ± (0.5% reading + 2 C) 392 F ~ 1832 F 1 F ± (0.4% reading + 4 F) ± (0.5% reading + 4 F) 1000 C ~ 1300 C 1 C ± (0.6% reading + 2 C) ± (0.6% reading + 2 C) 1832 F ~ 1999 F 1 F ± (0.6% reading + 4 F) ± (0.6% reading + 4 F) Input protection: 9V DC or 6V rms. 9

(2) Thermocouple Characteristics: K-type thermocouple. 50BK bead thermocouple: 1. Temperature Range : -40 C to 204 C (-40 F to 399.2 F). 2. Tolerances : ± (2.2 C or 0.75%) from 0 C to 204 C. ± (2.2 C or 2.0%) from 0 C to -40 C. 3. Wire Length : 1m, with miniature plug. Teflon tape insulated. OPERATION This instrument is designed to use external K-type thermocouple as temperature sensor. Temperature indication follows National Bureau of Standards and IEC 584 temperature / voltage tables for K-type thermocouple are supplied with thermometer. 10

WARNING TO AVOID ELECTRICAL SHOCK, DO NOT USE THIS INSTRUMENT WHEN VOLTAGES AT THE MEASURE- MENT SURFACE EXCEED 24V RMS OR AC OR 60V DC. (6Vrms AC OR 9VDC FOR 52) TO AVOID DAMAGE OR BURNS, DO NOT MAKE TEMPERATURE MEASUREMENTS IN MICROWAVE OVENS. 3-1 Preparation and Caution before Measurement 1. Before measurement, warm up for at least 30 seconds, after connecting the thermocouple to the thermometer. 2. If the instrument is used near noise generating equipment, be aware that the display may become unstable or indicate large errors. 3-2 Temperature Measurements 1. Connect the plug of the thermocouple to the connector of the thermometer. 2. Select the desired input mode, resolution and C/ F. 3. Use the sensing point of the thermocouple to measure the surface to be measured. 4. Read the stable reading. 5. "Warning: Do not measure the surface if the potential exceeds 60 Vd.c. or 24 Vr.m.s." 11

MAINTENANCE To keep the instrument clean, wipe the case with a damp cloth and detergent, do not use abrasives or solvents. Any adjustment, maintenance and repair shall be made by a skilled person. To maintain the thermocouple in good condition, observe the following precautions: Avoid excess bending. Do not overheat the thermocouple. Avoid chemical reactions that can damage the thermocouple. BATTERY REPLACEMENT The meter is powered by a single 9V battery. Refer to Figure 2 and use the following procedure to replace the battery: 1. Turn the meter off. Remove the thermocouple connector. 2. Remove the holster. 3. Position the meter face down. Remove the screw from the battery cover. 4. Remove the battery cover. 5. Lift the battery from case top, and carefully disconnect the battery from battery connector leads. 6. Install a new battery. 7. Replace the battery cover. Reinstall the screw and replace the holster. 12

BATTERY REPLACEMENT Screw 9V Battery Battery cover Figure 2 Battery connector 13

HOW TO USE THE TILT STAND AND HOLSTER Swing the stand out for easier meter reading. Hang on a nail at the workbench. 14

Africa RS Components SA P.O. Box 12182, Vorna Valley, 1686 20 Indianapolis Street, Kyalami Business Park, Kyalami, Midrand South Africa www.rs-components.com China RS Components Ltd. Suite 23 A-C, East Sea Business Centre Phase 2, No. 618 Yan'an Eastern Road Shanghai, 200001 China www.rs-components.com Japan RS Components Ltd. West Tower (12th Floor), Yokohama Business Park, 134 Godocho, Hodogaya, Yokohama, Kanagawa 240-0005 Japan www.rs-components.com Asia RS Components Pte Ltd. 31 Tech Park Crescent Singapore 638040 www.rs-components.com Europe RS Components Ltd. PO Box 99, Corby, Northants. NN17 9RS United Kingdom www.rs-components.com U.S.A Allied Electronics 7151 Jack Newell Blvd. S. Fort Worth, Texas 76118 U.S.A. www.alliedelec.com South America RS Componentes Limitada Av. Pdte. Eduardo Frei M. 6001-71 Centro Empresas El Cortijo Conchali, Santiago, Chile www.rs-components.com