Finnigan TRITON Finnigan NEPTUNE. High Resolution Multicollector Mass Spectrometers

Similar documents
Thermo Scientific TRITON Thermal Ionization MS. Thermo Scientific NEPTUNE Multicollector ICP-MS. High Resolution Multicollector Mass Spectrometers

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

MetWorks Metabolite Identification Software

Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer

of mass spectrometry

Thermo Scientific Neptune XT MC-ICP-MS

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

Thermo Scientific DELTA V Advantage DELTA V Plus

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

Defining quality standards for the analysis of solid samples

HELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS.

IRMS. perspective. Isotope Ratio Mass Spectrometry.

ICP-MS. High Resolution ICP-MS.

Introduction to Fourier Transform Infrared Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy

TPDRO 1100 Advanced Catalyst Characterization. For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

PERSPECTIVE STABLE ISOTOPE RATIO MS

HIGH PERFORMANCE MASS SPECTROMETERS FOR EARTH AND PLANETARY SCIENCE

PERSPECTIVE STABLE ISOTOPE RATIO MS

Exploring new fields of Applications using Multi Collector Magnetic Sector MS

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Thermo Scientific LC IsoLink

DFS Magnetic Sector GC/MS

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

for XPS surface analysis

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

LTQ XL Linear Ion Trap Mass Spectrometer More Structural Information with MS n

Low level Os isotopic measurements using multiple ion counting

Improvement of bulk analysis of environmental samples by using a multiple collector ICP-MS

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Thermo Scientific 253 Plus 10 kv Isotope Ratio MS. Utilize the Gold Standard. in isotope ratio MS. Robustness Sensitivity Precision

Thermo Scientific TPDRO 1100 Advanced Catalyst Characterization

LCQ Fleet Ion Trap LC/MS n Exceptional Analytical Value

Finnigan TSQ Quantum Discovery MAX

Fast, Effective XPS Point Analysis of Metal Components

The Analyzer. We will deal mainly with magnetic sector instruments here although we will talk briefly about other separation methods later.

Error Analysis. The big questions are: - What value best represents a set of measurements and how reliable is it?

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

ICPMS Doherty Lecture 1

IN QUALITATIVE ANALYSIS,

ARL OPTIM X X-Ray Fluorescence Spectrometer. Optimized Performance for Your Application

Finnigan TRACE DSQ GC/MS

Uncertainty in Measurement of Isotope Ratios by Multi-Collector Mass Spectrometry

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

vacuum analysis plasma diagnostics surface science gas analysis

Interface (backside) & Extraction Lens

THE MEASUREMENT OF SOLAR ULTRAVIOLET SPECTRAL IRRADIANCE PROBLEMS & SOLUTIONS

Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

Catalysis CAPABILITIES

Overcoming Interferences with the Thermo Scientific icap 7000 Plus Series ICP-OES

S8 TIGER Series 2 for ASTM D 6443

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Beam Diagnostics and Instrumentation JUAS, Archamps Peter Forck Gesellschaft für Schwerionenforschnung (GSI)

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

Extrel is widely respected for the quality of mass spectrometer systems that are

ICP-Mass Spectrometer

Following documents shall be used for reference on quantities, units, prefixes and other technical vocabulary in this document:

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

= 6 (1/ nm) So what is probability of finding electron tunneled into a barrier 3 ev high?

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS.

Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

FSA TM Multi-bit Digital Processors

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Nu Plasma II - Collector Configuration

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Thermo Finnigan LTQ. Specifications

Extrel Application Note

OPTICAL PARTICLE SIZER MASS CALIBRATION METHOD

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Alpha-Energies of different sources with Multi Channel Analyzer

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

Mass Spectrometers. for Surface Analysis SURFACE ANALYSIS

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

Thermo Scientific GasBench II

Translational Biomarker Core

Key Words Nanoparticles, spicp-ms, ICP-MS, Qtegra ISDS Software, AF4-ICP-MS

Alpha-energies of different sources with Multi Channel Analyzer (Item No.: P )

Time of Flight Mass Spectroscopy and Velocity Map Imaging

DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS.

The RX-6000 Sulfur in Oil Analyzer For the analysis of Sulfur in Oil and other elements from S to U

Transcription:

m a s s s p e c t r o m e t r y Finnigan TRITON Finnigan NEPTUNE High Resolution Multicollector Mass Spectrometers Analyze Detect Measure Control

Finnigan TRITON / Finnigan NEPTUNE High Resolution Multicollector Mass Spectrometers Finnigan TRITON Finnigan NEPTUNE High Resolution Multicollector Mass Spectrometers Based on more than 25 years experience in variable multicollector instrumentation, Thermo Electron Corporation has developed two instruments based on an innovative multicollector platform. High resolution ion optics corrected for second order image aberrations largest mass dispersion (812 mm) angular and energy focusing image planes are almost coincident Zoom optics to enhance dynamic multicollector measurements precise peak overlap for multi-dynamic measurements Field proven Faraday cups with largest aspect ratio No cup factors Multiple Ion Counting (MIC) Up to 8 moveable miniaturized SEMs in parallel Variable multicollector Variable in position Variable in detector type (Faraday/SEM) Up to 17 collectors in parallel Plug-in design of Faradays and SEMs 17 % relative mass range Virtual Amplifier system No amplifier calibration bias Linear response up to 50 V (positive ion mode) 10 kv acceleration voltage Highest sensitivity All metal-sealed vacuum system Ultra high vacuum system High abundance sensitivity Bakeable at high temperature Retardation lens (RPQ option) Excellent abundance sensitivity Single focusing for thermal ionization source Finnigan TRITON Double focusing for inductively coupled plasma source Finnigan NEPTUNE

No compromise is the common philosophy

Finnigan TRITON / Finnigan NEPTUNE High Resolution Multicollector Mass Spectrometers Finnigan TRITON The Finnigan TRITON sets a new standard in high precision TIMS isotope ratio measurements. The Finnigan TRITON s unique capabilities have earned it the reputation of the natural choice in TIMS instrumentation. Guaranteed external precision of Nd and Sr is 5 ppm (1 SD), both in static and multi-dynamic acquisition 2 ppm external precision has been shown Improved sensitivity 21 position sample turret for high throughput User friendly software for high throughput, with network capabilities

Finnigan NEPTUNE The Finnigan NEPTUNE completes Thermo Electron Corporation s integrated product family for elemental and isotopic analysis. It shares the field proven ICP interface with the Finnigan ELEMENT2, the most advanced single collector high mass resolution ICPMS. Finnigan NEPTUNE and Finnigan TRITON are using the same high precision multicollector platform. The Finnigan NEPTUNE defines a third generation MC-ICPMS, combining, for the first time, the features of high mass resolution, variable multicollection, zoom optics and multiple ion counting (MIC). High mass resolving power with flat top peak sections Excellent short-term and long-term stability of signal intensity and mass bias Full sensitivity with standard sample introduction system Fully integrated software for unattended operation and high throughput

Finnigan TRITON / Finnigan NEPTUNE High Resolution Multicollector Mass Spectrometers Key Technologies Advanced Multicollector Ion Optics Large mass dispersion using an ion optical magnification of 2: The large mass dispersion of 812 mm provides generous space for the versatile collector array. The mass dispersion is achieved by an ion optical magnification of 2, which has the additional advantages of increased focal depth and improved cup performance. d d'=2d High Performance Faraday Cups The Faraday cups are the largest ever produced for a commercial multicollector. They are laser machined from solid carbon to guarantee uniform response, high linearity, low noise and long lifetime. The Faraday cups are designed to completely eliminate the need for cup factors 1. The effect of ion optical magnification on cup performance is depicted in the graph. With increasing ion optical magnification the divergence angles of the ion beams are reduced and the dispersion is increased. As a result, cups can be wider and deeper. Scattered particles released at the cup's side wall by the incoming ion beams are less likely to escape and do not alter the true ion current. Inside view of a Faraday Cup Source Magnet lens Faraday cup Magnification = 1 Secondary particles are released close to the cup entrance Ions Magnification = 2 Faraday cup Source Magnet lens Larger effective depth of cups: less emission of scattered particles 1 Patent No. US 6,452,165 B1

Multi Ion Counting The Variable Multicollector Eight moveable collector supports and one fixed center channel are installed on the optical bench of the new high precision variable multicollector module. The center channel is equipped with a Faraday cup and optionally an ion counter with or without the retardation lens (RPQ) to achieve the ultimate abundance sensitivity. The eight detector supports can be precisely positioned along the focal plane, according to the specific needs of the application. The maximum distance between the outermost channels corresponds to a relative mass range of 17% sufficient for the simultaneous measurement of 6 Li and 7 Li or 202 Hg to 238 U. The variable detector supports are driven by motors. Beneath each variable detector platform there is a position sensor located inside the vacuum chamber. Precise in situ monitoring of the detector position directly at the optical bench of the variable multicollector ensures reliable positioning, which is a must for high precision isotope ratio measurements at high mass resolution. Multiple Ion Counting (MIC) Each moveable support can carry either a Faraday cup, or a miniature Secondary Electron Multiplier (SEM) or a combination of both in a package. All detectors are of plug-in design 2 and can be readily exchanged. It is possible to equip one detector platform with a package of ion counters plus one Faraday cup. The above combination is perfect for fixed counter packages for specific elements in the high mass range e.g. lead and uranium because the packages can be built very compact. The configuration where the ion counter packages are attached to the outer moveable Faraday cups (H4, L4) keeps the full flexibility of the Faraday cup array. The insertion of the additional ion counters at these outer positions does not block any Faraday cup configuration. A fully equipped system can be loaded with a maximum of 17 channels: 9 Faraday cups plus 8 ion counters - all of which can be used in a simultaneous multicollector measurement. 2 Patent applied for US 10/618 285

Finnigan TRITON / Finnigan NEPTUNE High Resolution Multicollector Mass Spectrometers Key Technologies The Amplifier Each Faraday cup is connected to a current amplifier. The amplifier signal is digitized by a high linearity voltage to frequency converter with an equivalent digital resolution of 22 bits. This ensures sub-ppm digital resolution of all measured signals independent of the actual signal intensity. The amplifiers are mounted in a doubly shielded, evacuated and thermostated housing with a temperature stability of ± 0.01 C. The dynamic range of the current amplifiers is extended to 50 V in positive ion detection mode. For negative ions it is restricted to 15 V. The extended dynamic range supports the measurement of large isotope ratios, because it directly leads to an improved signal to noise ratio for the minor isotopes. For classical systems the need for a precise cross calibration of the current amplifiers defines a precision barrier in static multicollection. Even with perfect Faraday cups giving uniform response, results of static measurements are biased by the accuracy and reproducibility of the gain calibration. In the classical method of cross calibration, a high precision, constant current source is sequentially connected to all amplifiers. However, with this method, amplifiers cannot be calibrated to better than ~5 ppm per channel. For instance if one considers an isotope system consisting of three isotopes the best external precision can be estimated to be: 5 ppm x 3 = ~9 ppm. The Virtual Amplifier The goal of the new multicollector development was to break through the 5 ppm precision barrier. Finnigan TRITON and Finnigan NEPTUNE use a patented measurement procedure, which completely eliminates gain calibration biases: the Virtual Amplifier concept 3. In all previous multicollector systems the relation Faraday cups 1 2 3 4 5 6 7 8 9 Relay Matrix relay open relay closed evacuated and thermostated housing (connection) between individual Faraday cups and amplifiers was fixed. In the Virtual Amplifier concept all Faraday cups involved in a certain measurement are sequentially connected to all amplifiers. As a result all signals have been measured with the same set of amplifiers and for the calculation of the isotope ratios all calibration biases of the amplifiers are cancelled. Amplifier and V/F converter 1 2 3 4 5 6 7 8 9 Measurement channels 50 V Dynamic Range Elimination of Amplifier Biases No Cup Factors Up to 17 Ion Beams can be detected simultaneously 3 Patent No. US 6,472,659 B1

Measuring Large Isotope Ratios The measurement of large isotope ratios is affected by scattered ions generated at slits and apertures, the flight tube walls and most importantly the interaction of ions with residual gas particles. Ions which suffered one of these interactions have lost kinetic energy and/or have changed their direction of motion. As a result, these ions appear at incorrect mass positions along the focal plane, typically increasing background at neighbouring masses. The Finnigan TRITON and Finnigan NEPTUNE employ an optional Retarding Potential Quadrupole Lens (RPQ) 4 that acts as a high selectivity filter for ions with disturbed energy or angle. With the Finnigan TRITON, whose thermal ionization source produces ions with a small energy spread (0.5 ev), the RPQ reduces the abundance sensitivity by two orders of magnitude from typical 2 ppm ( 238 U ± 1 u) to 20 ppb. The dark noise of the ion counting system used in the RPQ is less than 10 counts per minute. This combination of low dark noise and high abundance sensitivity allows the determination of large isotope ratios with the highest accuracy. Combining the RPQ with the Finnigan NEPTUNE, whose ICP source generates ions with an energy spread up to ~5 ev, improves the abundance sensitivity by one order of magnitude from guaranteed 5 ppm to 500 ppb with more than 90 % transmission. The abundance sensitivity of the Finnigan NEPTUNE can be further improved by increasing the energy barrier of the RPQ filter: At 50 % transmission, an abundance sensitivity of 150 ppb can be achieved. However, the stability of the system will be reduced. Counts / s 180 150 120 A < 2 x 10-6 90 60 Peak tail of 232 Th 30 0 5 4 3 2 1 0 RPQ A < 5 x 10-9 232 Th / 230 Th = 2 900 000 : 1-1 229.5 Mass (u) 231.5 Finnigan TRITON: abundance sensitivity with and without RPQ filter Finnigan NEPTUNE: abundance sensitivity without RPQ filter 4 Patent No. US 5180913

Finnigan TRITON / Finnigan NEPTUNE High Resolution Multicollector Mass Spectrometers Finnigan TRITON Thermal Ionization Source The thermal ionization source is characterized by a very small (~0.5 ev) kinetic energy spread of the ions. Therefore, a single focusing geometry that focuses for angular divergence only is fully sufficient. Chromatic aberrations due to the initial energy spread of the ions can be neglected. In this configuration the magnetic sector lens focuses ions of different mass along an inclined focal plane with 45 angle. The magnet is laminated for high speed peak jumping and low hysteresis. The inner width of the flight tube is 14 mm, ensuring minimal scattering. Baffles are present along the flight path to directly catch any diverging ions and to minimize scattering at the side walls. The New TI Source The new ion source optics of the Finnigan TRITON have been optimized for maximum ion transmission for both single and double filament techniques. It makes the Finnigan TRITON about twice as sensitive as the Finnigan MAT 262. The new sample turret holds 21 single or double filaments. The filaments can be easily exchanged without using any tools. Special care has been taken by shaping the ion source lens elements so that the build up of contaminations and memory in the source are minimized. The lens stack is easily accessible by the user for inspection and maintenance. The ion source is held at an acceleration potential of 10 kv to achieve optimum sensitivity.

The Zoom Optics Multi-dynamic measurements can be used to eliminate cross calibration biases of Faraday cup detectors or multiple-ioncounting (MIC) detectors. The philosophy of no compromises led us also to achieve the ultimate performance using this procedure. Historically, the collectors had to be set to compromise positions in order to fully catch the ion beams in all different cup configurations. The Zoom Optics is a tool to change mass dispersion. If used synchronously with switching the ion beams, perfect overlap of all peaks in all configurations is achieved. This scheme is fully integrated into Finnigan TRITON s automatic measurement. For instance, the Zoom Optics allows measurement of all isotopes of UO in the same detector configuration as U without the need of mechanical readjustment of the detector positions. Multicollector configurations for Nd and Sr, along with the amplifier rotation scheme (Virtual Amplifier) 140 Ce 142 Nd 143 Nd 144 Nd 145 Nd 146 Nd 147 Sm 148 Nd 150 Nd Faraday Faraday Faraday Faraday Faraday Faraday Faraday Faraday Faraday Cup L4 Cup L3 Cup L2 Cup L1 Center Cup H1 Cup H2 Cup H3 Cup H4 Blockwise Amplifier Rotation 1 2 3 4 5 6 7 8 9 9 1 2 3 4 5 6 7 8 8 9 1 2 3 4 5 6 7 7 8 9 1 2 3 4 5 6 6 7 8 9 1 2 3 4 5 5 6 7 8 9 1 2 3 4 4 5 6 7 8 9 1 2 3 3 4 5 6 7 8 9 1 2 2 3 4 5 6 7 8 9 1 Amplifier Number 84 Sr 85 Rb 86 Sr 87 Sr 88 Sr Faraday Faraday Faraday Faraday Far/IC Faraday Faraday Faraday Faraday Cup L4 Cup L3 Cup L2 Cup L1 Center Cup H1 Cup H2 Cup H3 Cup H4

Finnigan TRITON / Finnigan NEPTUNE High Resolution Multicollector Mass Spectrometers Finnigan NEPTUNE Double Focusing High Resolution MC-ICP-MS The kinetic energy distribution of ions generated in an ICP source is large (~20 ev), compared to ions from a thermal ionization source. A double focusing analyzer, focusing both ion energy and angular divergence, is the best technical solution for this challenge. Reduced Energy Spread Using a CD-System Finnigan NEPTUNE s ICP interface reduces the initial kinetic energy spread from ~20 to ~5 ev by capacitively decoupling (CD) the plasma from the load coil using a grounded platinum guard electrode. This low kinetic energy distribution, together with a wide energy acceptance of the mass analyzer and 10 kv ion acceleration voltage, eliminates all effects of ion energy spread on isotope ratios and mass bias. Plasma interface at ground potential The plasma interface is held at ground potential, allowing easy access to the nebulizer, spray chamber and torch. Changing from solution to laser ablation is as easy as the connection of an autosampler. The plasma interface can be isolated from the analyzer through an automatic gate valve. The ion transfer optics focus the ions from the plasma interface onto the entrance slit of the double focusing analyzer. Mass bias is mainly generated in the plasma interface and the ion transfer optics. Finnigan NEPTUNE s excellent mass bias stability, sensitivity and low background result from Thermo Electron Corporation s unique ion transfer optics 5. 5 Patent No. US 5625185 Reduced Energy Spread Using a CD-System

Interference Free Measurements by High Mass Resolution Multicollection High Mass Resolution The ion optics of the Finnigan NEPTUNE achieve high mass resolving power on all detectors along the image plane. This capability is based on its refined ion optics with Almost coincident angular and energy image planes Large focal depth due to large ion optical magnification (see page 6) Finnigan NEPTUNE can be operated in three different resolution settings: Low, medium and high resolution. In high resolution settings the resolving power can go up to m/ m = 10.000. The m/ m is derived from the peak slope of the rising edge measured at 5% and 95% relative peak height. For single collector sector field instruments the mass resolution is changed by switching both the source slit width and the detector slit width. For high mass resolution a small source slit and a small detector slit is used. This typically results into very narrow triangular shaped peaks in the mass spectrum and ensures safe peak separation of interfering species. However, for high precision isotope ratio measurements a wide peak flatness range is required and triangular peak shapes cannot be used. In order to separate molecular interferences from elemental peaks on a multicollector instrument a small source slit has to be selected as well, however, the detector slit can be kept at low resolution setting. The individual detectors of the variable multicollector can be positioned such that just the elemental ions can enter the detector whereas the interfering ions are stopped on one side of the detector slit. The typical operation mode of a multicollector instrument is a static operation mode where the magnetic field remains constant and the interferences are stopped at the detector slit. According to the systematics of the nuclear mass defect all molecular interferences in the low and medium mass range are heavier than the elemental species and all interferences can readily be stopped at the same side of the detector slit. The use of the wide detector slit for all resolution settings is the best choice because it guarantees the widest peak flatness at high resolving power, which is a must for high precision and accurate isotope ratio measurements. Peakscan of all Fe isotopes and molecular interferences at high resolving power. Fe isotopes can be measured free of any interferences in the first peak plateau at the low mass side. At the multicollector mass position indicated in the figure just the elemental ion beams enter the Faraday cups while the molecular interferences are stopped at one side of the detector slit (see right hand side Figure). signal [V] normalized to 56 Fe + 7 6 5 4 3 2 1 54 F e + 56 F e + 57 F e + 58 F e + multicollector mass Fe + Interferences 40 Ar 16 O + 40 Ar 16 O 1 H + 40 Ar 18 O + 40 Ar 14 N + 56 Fe collector slit 40 Ar 16 O 57 Fe collector slit 40 Ar 16 O 1 H 0 55.85 55.90 55.95 mass 56.00 56.05 Faraday 1 Faraday 2

Finnigan TRITON / Finnigan NEPTUNE High Resolution Multicollector Mass Spectrometers Software Package The Finnigan TRITON and Finnigan NEPTUNE software package Most of the software modules are common to both instruments: Cup configuration editor to define and select cup configurations Method editor to set up user-defined measurement procedures On-line and off-line data evaluation packages including statistical capabilities and display of the results in spreadsheet or graphical form Sequence editor for automatic, unattended acquisition and evaluation of samples including sample/standard bracketing and blank substraction. Automated report generation of analytical results. Tuning the Source Finnigan TRITON (TI source) Fully automated sample turret manipulation Configurable and automated filament heating Pyrometer readout of the filament temperature Finnigan NEPTUNE (ICP source) Fully automated plasma start sequence Easy auto sampler setup Finnigan NEPTUNE Tune Window Method Setup Selection of cup configuration Cup position Faraday or SEM Assignment of isotope masses to the detector Data collection strategy: Static measurements Dynamic measurements Fast single collector peak jumping measurements Integration of sample heating program (Finnigan TRITON) Selection of bias/fractionation corrections Definition of isotope ratios Outlier tests Interference correction Equation editor for user-defined data reduction Switch key to synchronize start of data acquisition with Laser ablation (Finnigan NEPTUNE) Finnigan TRITON Method Editor

Sequence Editor Automatic acquisition of samples, standards and/or blanks Computer control of autosampler Online blank subtraction and mass bias correction using an external standard Report of delta-values Online ASCII export Sequence accepts external trigger for starting (i.e. from Laser system) Sequence Editor Evaluation On-line and off-line evaluation User configurable display of results: Spreadsheet Graphical display Access to all raw data On-line monitoring of ratios, intensities, statistics vs. time Result Display Process Control Language (PCL) Script language based on C programming language Modification of existing procedures: Baseline determinations Gain calibration Definition of new procedures Open for user-defined experiments Scripts can be: Run individually Combined with existing software modules PCL Script Editor The software runs under the latest Microsoft Windows operating system. The software package is optimized for stability, performance and is fully compatible with future operating systems. The software combines the strength of an optimized, Windows-based package written in C++ with the power and flexibility of a user-friendly open structure, realized in our unique Process Control Language, PCL. The Microsoft Windows operating system allows the data system to be easily connected to a network, enabling data transfer and remote control of the instrument.

History of the Inorganic Product Lines In addition to these offices,thermo Electron Corporation maintains a network of representative organizations throughout the world. Laboratory Solutions Backed by Worldwide Service and Support Tap our expertise throughout the life of your instrument. As an industry leader in analytical instruments, Thermo extends its support throughout our worldwide network of Thermo-trained and certified engineers who are experts in laboratory technologies and applications. Put our team of experts to work for you in a range of disciplines, from system installation, training and technical support, to complete asset management and regulatory compliance consulting. Improve your productivity and lower the cost of instrument ownership through our product support services. Maximize uptime while eliminating the uncontrollable cost of unplanned maintenance and repairs. When it s time to enhance your systems, Thermo also offers certified parts and a range of accessories and consumables suited to your application. To learn more about our products and comprehensive service offerings, visit our Web site at www.thermo.com. Australia +61 2 8844 9500 analyze.au@thermo.com Austria +43 1 333 50340 analyze.at@thermo.com Belgium +32 2 482 30 30 analyze.be@thermo.com Canada +1 800 532 4752 analyze.ca@thermo.com China +86 10 5850 3588 analyze.cn@thermo.com France +33 1 60 92 48 00 analyze.fr@thermo.com Germany +49 6103 4080 analyze.de@thermo.com India +91 22 2778 1101 analyze.in@thermo.com Italy +39 02 950 591 analyze.it@thermo.com Japan +81 45 453 9100 analyze.jp@thermo.com Netherlands +31 76 587 98 88 analyze.nl@thermo.com Nordic +46 8 556 468 00 analyze.se@thermo.com South Africa +27 11 570 1840 analyze.sa@thermo.com Spain +34 91 657 4930 analyze.es@thermo.com Switzerland +41 61 48784 00 analyze.ch@thermo.com UK +44 1442 233555 analyze.uk@thermo.com USA +1 800 532 4752 analyze.us@thermo.com www.thermo.com DIN EN ISO 9001:2000 Thermo Electron (Bremen) GmbH is certified DIN EN ISO 9001:2000 2005 Thermo Electron Corporation. All rights reserved. Windows is a registerd trademark of Microsoft Corporation. All other trademarks are the property of Thermo Electron Corporation and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. BR30028_E02/05C