Test Report. Applicant : RECOM Engineering GmbH & Co. KG. Date : Jun 03, 2016

ICP Test Report Certification Packet

ICP Test Report Certification Packet

ICP Test Report Certification Packet

ICP Test Report Certification Packet

TEST REPORT NUMBER: SHAH S1 APPLICANT: LITEON SEMICONDUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.

TEST REPORT NUMBER: SHAH DATE: AUG 18, 2008 APPLICANT: LITEON SEMICONDUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.

TEST REPORT NUMBER: SHAH S1 APPLICANT: LITEON SEMICONDUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.

ICP Test Report Certification Packet

ICP Test Report Certification Packet

ICP Test Report Certification Packet


ICP Test Report Certification Packet

ICP Test Report Certification Packet

Test Report Number: SHAH Applicant: TE CONNECTIVITY Date: 22 Feb, 2017 BUILDING A5,NO.1528 GUMEI ROAD, SHANGHAI,CHINA Attn: CC WU

ICP Test Report Certification Packet

ICP Test Report Certification Packet

ICP Test Report Certification Packet

Certificate of non-use of The Controlled Substances

Certificate of non-use of The Controlled Substances

TEST REPORT NUMBER: SHAH TESTS CONDUCTED. (A) TEST RESULT SUMMARY FOR RoHS DIRECTIVE:

ICP Test Report Certification Packet

TEST REPORT Reference No. : TRHZ Date : Sep. 18, 2013 Page No. : 1 of 5

ICP Test Report Certification Packet

TEST REPORT. Page : 1 of 9 Report No. RT14R-U E Date: Oct. 13, : The following submitted sample(s) said to be:-

Certificate of non-use of The Controlled Substances

ICP Test Report Certification Packet

TEST REPORT. : The following submitted sample(s) said to be:-

TEST REPORT. : The following submitted sample(s) said to be:- SAMPLE RECEIVED : Jan. 07, 2019 TESTING DATE : Jan. 07, 2019 ~ Jan.

APPLICANT: CACTUS TECHNOLOGIES LTD DATE : JUL 25, 2007 SUITE /F BILLION TRADE CENTER 31 HUNG TO ROAD KWUN TONG KOWLOON HONG KONG

: DAM1-125,DAM1-160,DAM1-400,DAM1-630,DAM1-800, DAM1-1600

Applicant: Cactus Technologies Ltd Date : Apr 07, 2010 Suite C 15/F Capital Trade Center 62 Tsun Yip Street Kwun Tong Kowloon Hong Kong

ICP Test Report Certification Packet

TEST REPORT. Address : , Doksan-dong, Geumcheon-gu, Seoul, Korea Page: 1 of 12 Report No. RT16R-S E Date: Jul.

TEST REPORT. : Lead Frame / Ag is plated on Ni-Fe Alloy-A42 material

ICP Test Report Certification Packet

Test Report No. : KE/2016/B2076 Date : 2016/11/24 Page : 2 of 8 Test Result(s) PART NAME NO.1 : GRAY Test Item (s): Unit Method Cadmium (Cd) mg/kg Wit

Page 2 of 11 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of

ICP Test Report Certification Packet

TEST REPORT. ADDRESS : 77, Seokam-ro 13-gil, Iksan, Jeonllabuk-do, Korea PAGE: 1 of 8 REPORT NO. RT17R-U2181-E DATE: Dec. 29, 2017

Test Report No. : CE/2014/B4428 Date : 2014/12/03 Page : 1 of 12 PELNOX CO., LTD. 8-7 BODAI, HADANO CITY, KANAGAWA , JAPAN *CE/2014/B4428* The

Page 2 of 12 Test Result(s) PART NAME No.1 IC TRANSCEIVER Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performed by

Page 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN PASTE Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and pe

Page 2 of 12 Test Result(s) PART NAME No.1 DK. BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Beryllium (Be) Test Item(s) Hexavalent Chr

ICP Test Report Certification Packet

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KE/2017/40842 Date : 2017/04/17 ROGERS CORPORATION 245 WOODSTOCK ROAD, WOODSTOCK, CT. 06

Page 2 of 12 Test Result(s) PART NAME No.1 YELLOW LUMP Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs Monobro

TEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.

ICP Test Report Certification Packet

Test Report No. : KA/2012/21431 Date : 2012/02/24 Page : 2 of 12 Test Result(s) PART NAME NO.1 : SILVER GRAY DIE ATTACH PASTE Test Item (s): Unit Meth

Test Report No. : KA/2014/61579 Date : 2014/07/07 Page : 2 of 14 Test Result(s) PART NAME NO.1 : GOLD BONDING WIRE Test Item (s): Unit Method Cadmium

Test Report No. : CE/2014/50660 Date : 2014/05/22 Page : 2 of 14 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Test

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KA/2017/50850 Date : 2017/05/25 HERAEUS MATERIALS SINGAPORE PTE LTD BLOCK 5002, ANG MO K

Page 2 of 10 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of

Test Report. Report No. SCL03H Page 1 of 7

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Test Item(s) Unit Method mg/kg With reference

Test Report No _rev01 Date: 06/DEC/2017 Page 1 of 5

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs

Test Report No. : CE/2014/32788 Date : 2014/03/27 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Test

Page 2 of 8 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) ( ) Sum of

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Test Report No Date : 27/NOV/2017 Page 1 of 5

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Cadmium (Cd) Test Item(s) Unit Method mg/kg With r

Chemical Laboratory - Kao., Test Report No. : KE/2018/11379 Date : 2018/01/25 Page : 2 of 8 Test Result(s) PART NAME NO.1 : CLEAR FAL FILM WITH ADHESI

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) H

Test Report No. : CE/2013/51536 Date : 2013/05/29 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa

ICP Test Report Certification Packet

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Test Item(s) Unit Method With reference to IEC (2013) an

Test Report No. CE/2014/43454A Date 2014/04/23 Page 2 of 11 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Ite

ICP Test Report Certification Packet

ICP Test Report Certification Packet

Test Report No. : KA/2012/40043 Date : 2012/04/10 Page : 2 of 8 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUNDS Test Item (s): MDL Resul

TEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.

Test Report. Report No. ECL01H Page 1 of 9

Page 2 of 9 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs

ICP Test Report Certification Packet

Page : 2 of 12 Test Result(s) PART NAME No.1 : MIXED ALL PARTS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Test Report No. CE/2016/43515 Date 2016/04/22 Page 2 of 7 Test Result(s) PART NAME No.1 AMBER FILM Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) He

Test Report No. CRSSA/01754/18 Date : 19/02/2018 Page: 1 of 11 CRS Ref. CRSSA/18/0368/Ametek

ICP Test Report Certification Packet

Test Report No. CRSSA/02575/18 Date : 09/03/2018 Page: 1 of 13 CRS Ref. CRSSA/18/0530/Dynacraft

Test Report No. KE/2017/C1499 Date 2018/01/02 Page 2 of 7 Test Result(s) PART NAME No.1 WHITE POLYOXYMETHYLENE Test Item(s) Cadmium (Cd) Lead (Pb) Mer

Test Report No. CE/2015/C2965A Date 2016/02/16 Page 2 of 7 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item

Page 2 of 10 Test Result(s) PART NAME No.1 LT.GRAY SHEET Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and perf

Transcription:

ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: ATOF Product #: 287xxx Series Issue Date: October 23, 2013 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC, 2011/65/EU)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: [Global EHS Engineer] (1) Parts, sub-materials and unit parts This document covers the ATOF series RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 Remarks: Non-HF contains Chlorine (Cl) in white foil & orange colorant. 1 Decemeber 01, 2005 Littelfuse, Inc. Page 1

Table 1: List of Raw Materials covered by this report Item Raw Material Part Number Raw Material Description Page(s) Part Number 1 57357 Molding Resin 3-12 257040.PXAPC, 028707.5PXCN 2 955412-001 Plated Zinc Strip 13-18 257040.PXAPC 028707.5PXCN 3 425498 White Foil 19-28 257040.PXAPC 028707.5PXCN 4 57874 Colorant- Gray 29-38 5 57875 Colorant- Violet 39-47 6 57876 Colorant- Pink 49-58 7 57878 Colorant- Brown 59-68 028707.5PXCN 8 57879 Colorant- Red 69-78 9 57880 Colorant- Blue 79-88 10 57877 Colorant- Tan 89-98 11 57883 Colorant- Green 99-107 12 57884 Colorant- Orange 108-117 257040.PXAPC 13 57899 Colorant- Yellow 118-127 2

Number : TWNC00299229 Applicant: Littelfuse, S.A. de C.V. Date : Feb 25, 2013 Blvd. Fausto Z. Martinez #1800 Col. Magisterio Seccion 38 C.P. 26070 Piedra Negras, Coahuila, Mexico Sample Description: One (1) group of submitted samples said to be : Part Description : VYDYNE 21SP-C Nylon Part Number : 057357 Date Sample Received : Feb 19, 2013 Date Test Started : Feb 19, 2013 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0299229* Page 1 of 10

Number : TWNC00299229 (Ⅰ) Test Result Summary: Result Test Item Unit Test Method Semitransparent RL plastic pellets Heavy Metal With reference to IEC 62321: 2008, Cadmium (Cd) Content by microwave digestion and ND 2 determined by ICP- OES. With reference to IEC 62321: 2008, Lead (Pb) Content by microwave digestion and ND 2 determined by ICP- OES. With reference to IEC 62321: 2008, Mercury (Hg) Content by microwave digestion and ND 2 determined by ICP- OES. With reference to IEC 62321: 2008, by alkaline Chromium VI (Cr 6+ ) Content digestion and ND 1 determined by UV- Vis Spectrophotometer. *THJ0299229* Page 2 of 10

Number : TWNC00299229 Result Test Item Unit Test Method Semitransparent RL plastic pellets Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) With reference to Tetrabrominated Biphenyls IEC 62321: 2008, (TetraBB) by solvent Pentabrominated Biphenyls extraction and (PentaBB) determined by GC- Hexabrominated Biphenyls MS and further (HexaBB) HPLC-DAD Heptabrominated Biphenyls confirmation when (HeptaBB) necessary. Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) With reference to Tetrabrominated Diphenyl IEC 62321: 2008, Ethers (TetraBDE) by solvent Pentabrominated Diphenyl extraction and Ethers (PentaBDE) determined by GC- Hexabrominated Diphenyl Ethers MS and further (HexaBDE) HPLC-DAD Heptabrominated Diphenyl confirmation when Ethers (HeptaBDE) necessary. Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) *THJ0299229* Page 3 of 10

Number : TWNC00299229 Result Test Item Unit Test Method Semitransparent RL plastic pellets Phthalates Di(2-ethylhexyl) Phthalate With reference to (DEHP) EN 14372: 2004, by 0 Dibutyl Phthalate (DBP) solvent extraction 0 Benzyl Butyl Phthalate (BBP) and determined by GC-MS. 0 Halogen Content Fluorine (F) With reference to 0 Chlorine (Cl) EN 14582:2007 by 0 calorimetric bomb Bromine (Br) 0 Iodine (I) Others Hexabromo cyclododecane (HBCDD) with oxygen and determined by Ion Chromatograph. With reference to USEPA 3540C, by solvent extraction and determined by GC-MS. 0 ND 10 Remarks: = parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample Responsibility of Chemist: Kevin Liu/ Irene Chiou/ Vico Lin Date Sample Received : Feb 19, 2013 Test Period : Feb 19, 2013 to Feb 21, 2013 (Ⅱ) Limit: RoHS Limit Restricted Substances Limits Cadmium (Cd) content 0.01% (100) Lead (Pb) content 0.1% (1000) Mercury (Hg) content 0.1% (1000) Chromium VI (Cr 6+ ) content 0.1% (1000) Polybrominated Biphenyls (PBBs) 0.1% (1000) Polybrominated Diphenyl Ehters (PBDEs) 0.1% (1000) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0299229* Page 4 of 10

Number : TWNC00299229 (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 For non-metal part Sample preparation For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component PBBs/PBDEs Cr 6+ Cd/Pb/Hg Substrate Plating Weigh sample and add organic solvent Weigh sample and add alkaline solution For different material, digest the sample with appropriate acid *1 Cr 6+ By Soxhlet extraction or Solvent extraction Definite temp. extraction Confirm the tested samples are totally dissolved By spot test Negative *2 Get 50cm 2 sample Concentrate the extract and make up with organic solvent Cool and filter the extract Make up with deionized water By boiling water extraction Analyzed by GC-MSD Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by UV-VIS *THJ0299229* Page 5 of 10

Number : TWNC00299229 Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0299229* Page 6 of 10

Number : TWNC00299229 Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography *THJ0299229* Page 7 of 10

Number : TWNC00299229 Test For Phthalates Contents Reference Method: EN 14372: 2004 Sampling/grinding or cutting Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD *THJ0299229* Page 8 of 10

Number : TWNC00299229 Test For Hexabromocyclododecane (HBCDD) Reference Standard:USEPA 3540C Sampling/grinding or cutting Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0299229* Page 9 of 10

Number : TWNC00299229 Photo *THJ0299229* Page 10 of 10

Number : TWNC00336072 Applicant: Littelfuse, S.A. de C.V. Date : Oct 18, 2013 Blvd. Fausto Z. Martinez #1800 Col. Magisterio Seccion 38 C.P. 26070 Piedra Negras, Coahuila, Mexico Sample Description: One (1) group of submitted samples said to be : Part Description : Blade Part Number : 955408-108 Date Sample Received : Oct 09, 2013 Date Test Started : Oct 11, 2013 : As requested by the applicant, for details please refer to attached pages. Tested Components: (1) Grey metal substrate (2) Silvery plating layer Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0336072* Page 1 of 6

Number: TWNC00336072 Test Result Summary: Heavy Metal Test Item Unit Test Method Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr 6+ ) content mg/kg with 50 cm 2 With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by boiling water extraction and determined by UV-Vis Spectrophotometer. Result (1) (2) RL ND ND 2 19 284 2 ND ND 2 Negative Negative 0.02 Remarks: = parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample mg/kg with 50cm 2 = milligram per kilogram with 50 square centimeter Negative = A negative test result indicated positive observation was not found at the time of test. Responsibility of Chemist: Kevin Liu/ Irene Chiou Date Sample Received : Oct 09, 2013 Test Period : Oct 11, 2013 to Oct 18, 2013 RoHS Limit Restricted Substances Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr 6+ ) content Limits 0.01% (100) 0.1% (1000) 0.1% (1000) 0.1% (1000) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0336072* Page 2 of 6

Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI) Reference Method: IEC 62321 edition 1.0:2008 Number: TWNC00336072 Sample preparation Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Substrate Plating For different material, digest the sample with appropriate acid *1 Cr 6+ By spot test Confirm the tested samples are totally dissolved Negative *2 Get 50cm 2 sample Make up with deionized water By boiling water extraction Analyzed by ICP-OES Make up with deionized water and add diphenylcarbazide solution Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3,HCl,HF,H 2 O 2,H 3 BO 3 Metals HNO 3,HCl,HF Electronics HNO 3,HCl,H 2 O 2,HBF 4 Analyzed by UV-VIS *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0336072* Page 3 of 6

Number: TWNC00336072 End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for anyparticular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and onlyaccepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes nowarranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conductthe Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0336072* Page 4 of 6

Number: TWNC00336072 *THJ0336072* Page 5 of 6

Number: TWNC00336072 *THJ0336072* Page 6 of 6

Number : TWNC00336789 Applicant: Littelfuse, S.A. de C.V. Date : Oct 21, 2013 Blvd. Fausto Z. Martinez #1800 Col. Magisterio Seccion 38 C.P. 26070 Piedra Negras, Coahuila, Mexico Sample Description: One (1) group of submitted samples said to be : Part Description : Hot Stamp White Foil Part Number : 425498 Date Sample Received : Oct 15, 2013 Date Test Started : Oct 15, 2013 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0336789* Page 1 of 12

Number: TWNC00336789 Test Result Summary: Test Item Unit Test Method Result White foil RL Heavy Metal Cadmium (Cd) content With reference to IEC 62321-5: 2013, by microwave or acid digestion and determined by ND 2 ICP-OES. Lead (Pb) content With reference to IEC 62321-5: 2013, by microwave or acid digestion and determined by ND 2 ICP-OES. Mercury (Hg) content With reference to IEC 62321-4: 2013, by microwave or acid digestion and determined by ND 2 ICP-OES. Antimony (Sb) Content With reference to USEPA 3052, by microwave digestion and 92 2 determined by ICP-OES. Chromium VI (Cr 6+ ) content With reference to IEC 62321: 2008, by alkaline digestion and determined by UV-Vis Spectrophotometer. ND 1 Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) With reference to IEC 62321: Pentabrominated Biphenyls 2008, by solvent extraction (PentaBB) and determined by GC-MS and Hexabrominated Biphenyls further HPLC-DAD confirmation (HexaBB) when necessary. Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) *THJ0336789* Page 2 of 12

Number: TWNC00336789 Test Item Unit Test Method Result White foil Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) With reference to IEC 62321: Pentabrominated Diphenyl 2008, by solvent extraction Ethers (PentaBDE) and determined by GC-MS and Hexabrominated Diphenyl further HPLC-DAD confirmation Ethers (HexaBDE) when necessary. Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) With reference to EN 0 Chlorine (Cl) 14582:2007 by combustion 10493 50 bomb with oxygen and Bromine (Br) 0 determined by Ion Iodine (I) Chromatography. 0 Phthalates Di(2-ethylhexyl) Phthalate (DEHP) ND 10 Dibutyl Phthalate With reference to EN 14372: ND 10 (DBP) 2004, by solvent extraction Benzyl Butyl Phthalate and determined by GC-MS. ND 10 (BBP) Diisobutyl phthalate (DIBP) ND 10 Others With reference to USEPA Hexabromocyclododecane 3540C, by solvent extraction (HBCDD) and determined by GC-MS. ND 10 RL *THJ0336789* Page 3 of 12

Number: TWNC00336789 Remarks: = parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample Responsibility of Chemist: Kevin Liu/ Irene Chiou/ Vico Lin Date Sample Received : Oct 15, 2013 Test Period : Oct 15, 2013 To Oct 21, 2013 RoHS Limit Restricted Substances Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr 6+ ) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Limits 0.01% (100) 0.1% (1000) 0.1% (1000) 0.1% (1000) 0.1% (1000) 0.1% (1000) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0336789* Page 4 of 12

Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents Reference Standard:Cd/Pb: IEC 62321-5:2013; Hg: IEC 62321-4:2013; Chromium (VI)/PBBs/PBDEs: IEC 62321:2008 Number: TWNC00336789 For non-metal part Sample preparation For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component PBBs/PBDEs Cr 6+ Cd/Pb/Hg Substrate Plating Weigh sample and add organic solvent Weigh sample and add alkaline solution For different material, digest the sample with appropriate acid *1 Cr 6+ By solvent extraction By spot test Definite temp. extraction Confirm the tested samples are totally dissolved Get 50cm 2 sample Negative *2 Concentrate the extract and make up with organic solvent Cool and filter the extract Make up with deionized water By boiling water extraction Analyzed by GC-MS Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3,HCl,HF,H 2 O 2,H 3 BO 3 Metals HNO 3,HCl,HF Electronics HNO 3,HCl,H 2 O 2,HBF 4 Analyzed by UV-VIS *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0336789* Page 5 of 12

Measurement Flowchart: Test for Heavy Metal (Sb) Contents Reference Method:USEPA 3052 Number: TWNC00336789 Sampling Weigh sample and digest in microwave digestion oven with suitable acid Confirm the tested samples are totally dissolved Transfer the digested solution and make up with deionized water Analyzed by ICP-OES *THJ0336789* Page 6 of 12

Test for Halogen Contents Reference Method:EN 14582 Number: TWNC00336789 Sampling Add absorbent in a combustion bomb & place weighed sample into sample cup Fill oxygen into the combustion bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by Ion Chromatography *THJ0336789* Page 7 of 12

Test for Phthalates Contents Reference Method: EN 14372: 2004 Number: TWNC00336789 Sampling Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MS *THJ0336789* Page 8 of 12

Test for Hexabromocyclododecane (HBCDD) Content Reference Method:USEPA 3540C Number: TWNC00336789 Sampling Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MS *THJ0336789* Page 9 of 12

Number: TWNC00336789 End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for anyparticular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and onlyaccepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes nowarranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conductthe Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0336789* Page 10 of 12

Number : TWNC00299230 Applicant: Littelfuse, S.A. de C.V. Date : Feb 25, 2013 Blvd. Fausto Z. Martinez #1800 Col. Magisterio Seccion 38 C.P. 26070 Piedra Negras, Coahuila, Mexico Sample Description: One (1) group of submitted samples said to be : Part Description : Color concentrate gray Part Number : 057874 Date Sample Received : Feb 19, 2013 Date Test Started : Feb 19, 2013 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0299230* Page 1 of 10

Number : TWNC00299230 (Ⅰ) Test Result Summary: Heavy Metal Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Test Item Unit Test Method Chromium VI (Cr 6+ ) Content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by alkaline digestion and determined by UV-Vis Spectrophotometer. Result Dark gray plastic pellets RL ND 2 ND 2 ND 2 ND 1 With reference to IEC 62321: 2008, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary. *THJ0299230* Page 2 of 10

Number : TWNC00299230 Result Test Item Unit Test Method Dark gray plastic RL pellets Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl With reference to IEC Ethers (TetraBDE) 62321: 2008, by solvent Pentabrominated Diphenyl extraction and Ethers (PentaBDE) determined by GC-MS and Hexabrominated Diphenyl Ethers further HPLC-DAD (HexaBDE) confirmation when Heptabrominated Diphenyl necessary. Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Phthalates Di(2-ethylhexyl) Phthalate With reference to EN (DEHP) 14372: 2004, by solvent 0 Dibutyl Phthalate (DBP) extraction and 0 Benzyl Butyl Phthalate (BBP) determined by GC-MS. 0 Halogen Content Fluorine (F) With reference to EN 0 Chlorine (Cl) 14582:2007 by 0 calorimetric bomb with Bromine (Br) oxygen and determined 0 Iodine (I) by Ion Chromatograph. 0 Others With reference to USEPA Hexabromo cyclododecane 3540C, by solvent (HBCDD) extraction and determined by GC-MS. ND 10 *THJ0299230* Page 3 of 10

Number : TWNC00299230 Remarks: = parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample Responsibility of Chemist: Kevin Liu/ Irene Chiou/ Vico Lin Date Sample Received : Feb 19, 2013 Test Period : Feb 19, 2013 to Feb 21, 2013 (Ⅱ) Limit: RoHS Limit Restricted Substances Limits Cadmium (Cd) content 0.01% (100) Lead (Pb) content 0.1% (1000) Mercury (Hg) content 0.1% (1000) Chromium VI (Cr 6+ ) content 0.1% (1000) Polybrominated Biphenyls (PBBs) 0.1% (1000) Polybrominated Diphenyl Ehters (PBDEs) 0.1% (1000) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0299230* Page 4 of 10

Number : TWNC00299230 (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 For non-metal part Sample preparation For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component PBBs/PBDEs Cr 6+ Cd/Pb/Hg Substrate Plating Weigh sample and add organic solvent Weigh sample and add alkaline solution For different material, digest the sample with appropriate acid *1 Cr 6+ By Soxhlet extraction or Solvent extraction Definite temp. extraction Confirm the tested samples are totally dissolved By spot test Negative *2 Get 50cm 2 sample Concentrate the extract and make up with organic solvent Cool and filter the extract Make up with deionized water By boiling water extraction Analyzed by GC-MSD Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by UV-VIS *THJ0299230* Page 5 of 10

Number : TWNC00299230 Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0299230* Page 6 of 10

Number : TWNC00299230 Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography *THJ0299230* Page 7 of 10

Number : TWNC00299230 Test For Phthalates Contents Reference Method: EN 14372: 2004 Sampling/grinding or cutting Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD *THJ0299230* Page 8 of 10

Number : TWNC00299230 Test For Hexabromocyclododecane (HBCDD) Reference Standard:USEPA 3540C Sampling/grinding or cutting Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0299230* Page 9 of 10

Number : TWNC00299230 Photo *THJ0299230* Page 10 of 10

Number : TWNC00325494 Applicant: Littelfuse, S.A. de C.V. Date : Aug 02, 2013 Blvd. Fausto Z. Martinez #1800 Col. Magisterio Seccion 38 C.P. 26070 Piedra Negras, Coahuila, Mexico Sample Description: One (1) group of submitted samples said to be : Part Description : Colorant-Violet Part Number : 057875 Date Sample Received : Jul 30, 2013 Date Test Started : Jul 30, 2013 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0325494* Page 1 of 12

Number: TWNC00325494 Test Result Summary: Test Item Unit Test Method Result Violet plastic pellets RL Heavy Metal With reference to IEC 62321: Cadmium (Cd) content 2008, by microwave digestion ND 2 and determined by ICP-OES. With reference to IEC 62321: Lead (Pb) content 2008, by microwave digestion ND 2 and determined by ICP-OES. With reference to IEC 62321: Mercury (Hg) content 2008, by microwave digestion ND 2 and determined by ICP-OES. With reference to USEPA 3052, Antimony (Sb) Content by microwave digestion and ND 2 determined by ICP-OES. With reference to IEC 62321: Chromium VI (Cr 6+ ) content 2008, by alkaline digestion and determined by UV-Vis ND 1 Spectrophotometer. Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) With reference to IEC 62321: Pentabrominated Biphenyls 2008, by solvent extraction (PentaBB) and determined by GC-MS and Hexabrominated Biphenyls further HPLC-DAD confirmation (HexaBB) when necessary. Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) *THJ0325494* Page 2 of 12

Number: TWNC00325494 Test Item Unit Test Method Result Violet plastic pellets RL Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) With reference to IEC 62321: Pentabrominated Diphenyl 2008, by solvent extraction Ethers (PentaBDE) and determined by GC-MS and Hexabrominated Diphenyl further HPLC-DAD confirmation Ethers (HexaBDE) when necessary. Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) With reference to EN 128 50 Chlorine (Cl) 14582:2007 by calorimetric 0 bomb with oxygen and Bromine (Br) 0 determined by Ion Iodine (I) Chromatograph. 0 Phthalates Di(2-ethylhexyl) Phthalate (DEHP) ND 10 Dibutyl Phthalate With reference to EN 14372: ND 10 (DBP) 2004, by solvent extraction Benzyl Butyl Phthalate and determined by GC-MS. ND 10 (BBP) Diisobutyl Phthalate (DIBP) ND 10 *THJ0325494* Page 3 of 12

Number: TWNC00325494 Others Test Item Unit Test Method Hexabromocyclododecane (HBCDD) With reference to USEPA 3540C, by solvent extraction and determined by GC-MS. Result Violet plastic pellets RL ND 10 Remarks: = parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample Responsibility of Chemist: Kevin Liu/ Irene Chiou/ Vico Lin Date Sample Received : Jul 30, 2013 Test Period : Jul 30, 2013 To Aug 02, 2013 RoHS Limit Restricted Substances Limits Cadmium (Cd) content 0.01% (100) Lead (Pb) content 0.1% (1000) Mercury (Hg) content 0.1% (1000) Chromium VI (Cr 6+ ) content 0.1% (1000) Polybrominated Biphenyls (PBBs) 0.1% (1000) Polybrominated Diphenyl Ethers (PBDEs) 0.1% (1000) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0325494* Page 4 of 12

Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents Reference Method: IEC 62321 edition 1.0:2008 Number: TWNC00325494 For non-metal part Sample preparation For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component PBBs/PBDEs Cr 6+ Cd/Pb/Hg Substrate Plating Weigh sample and add organic solvent Weigh sample and add alkaline solution For different material, digest the sample with appropriate acid *1 Cr 6+ By Soxhlet extraction or Solvent extraction Definite temp. extraction Confirm the tested samples are totally dissolved By spot test Get 50cm 2 sample Negative *2 Concentrate the extract and make up with organic solvent Cool and filter the extract Make up with deionized water By boiling water extraction Analyzed by GC-MS Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3,HCl,HF,H 2 O 2,H 3 BO 3 Metals HNO 3,HCl,HF Electronics HNO 3,HCl,H 2 O 2,HBF 4 Analyzed by UV-VIS *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0325494* Page 5 of 12

Measurement Flowchart: Test for Heavy Metal (Sb) Contents Reference Method:USEPA 3052 Number: TWNC00325494 Sampling Weigh sample and digest in microwave digestion oven with suitable acid Confirm the tested samples are totally dissolved Transfer the digested solution and make up with deionized water Analyzed by ICP-OES *THJ0325494* Page 6 of 12

Test for Halogen Contents Reference Method:EN 14582 Number: TWNC00325494 Sampling Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography *THJ0325494* Page 7 of 12

Test for Phthalates Contents Reference Method: EN 14372: 2004 Test Report Sampling Number: TWNC00325494 Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MS *THJ0325494* Page 8 of 12

Test for Hexabromocyclododecane (HBCDD) Content Reference Method:USEPA 3540C Test Report Number: TWNC00325494 Sampling Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MS *THJ0325494* Page 9 of 12

Number: TWNC00325494 End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for anyparticular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and onlyaccepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes nowarranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conductthe Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0325494* Page 10 of 12

Number : TWNC00325496 Applicant: Littelfuse, S.A. de C.V. Date : Aug 02, 2013 Blvd. Fausto Z. Martinez #1800 Col. Magisterio Seccion 38 C.P. 26070 Piedra Negras, Coahuila, Mexico Sample Description: One (1) group of submitted samples said to be : Part Description : Colorant Pink Part Number : 057876 Date Sample Received : Jul 30, 2013 Date Test Started : Jul 30, 2013 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0325496* Page 1 of 12

Number: TWNC00325496 Test Result Summary: Test Item Unit Test Method Result Pink plastic pellets RL Heavy Metal With reference to IEC 62321: Cadmium (Cd) content 2008, by microwave digestion ND 2 and determined by ICP-OES. With reference to IEC 62321: Lead (Pb) content 2008, by microwave digestion ND 2 and determined by ICP-OES. With reference to IEC 62321: Mercury (Hg) content 2008, by microwave digestion ND 2 and determined by ICP-OES. With reference to USEPA 3052, Antimony (Sb) Content by microwave digestion and ND 2 determined by ICP-OES. With reference to IEC 62321: Chromium VI (Cr 6+ ) content 2008, by alkaline digestion and determined by UV-Vis ND 1 Spectrophotometer. Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) With reference to IEC 62321: Pentabrominated Biphenyls 2008, by solvent extraction (PentaBB) and determined by GC-MS and Hexabrominated Biphenyls further HPLC-DAD confirmation (HexaBB) when necessary. Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) *THJ0325496* Page 2 of 12

Number: TWNC00325496 Test Item Unit Test Method Result Pink plastic pellets RL Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) With reference to IEC 62321: Pentabrominated Diphenyl 2008, by solvent extraction Ethers (PentaBDE) and determined by GC-MS and Hexabrominated Diphenyl further HPLC-DAD confirmation Ethers (HexaBDE) when necessary. Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) With reference to EN 0 Chlorine (Cl) 14582:2007 by calorimetric 74 50 bomb with oxygen and Bromine (Br) 0 determined by Ion Iodine (I) Chromatograph. 0 Phthalates Di(2-ethylhexyl) Phthalate (DEHP) ND 10 Dibutyl Phthalate With reference to EN 14372: ND 10 (DBP) 2004, by solvent extraction Benzyl Butyl Phthalate and determined by GC-MS. ND 10 (BBP) Diisobutyl Phthalate (DIBP) ND 10 *THJ0325496* Page 3 of 12

Number: TWNC00325496 Others Test Item Unit Test Method Hexabromocyclododecane (HBCDD) With reference to USEPA 3540C, by solvent extraction and determined by GC-MS. Result Pink plastic pellets RL ND 10 Remarks: = parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample Responsibility of Chemist: Kevin Liu/ Irene Chiou/ Vico Lin Date Sample Received : Jul 30, 2013 Test Period : Jul 30, 2013 To Aug 02, 2013 RoHS Limit Restricted Substances Limits Cadmium (Cd) content 0.01% (100) Lead (Pb) content 0.1% (1000) Mercury (Hg) content 0.1% (1000) Chromium VI (Cr 6+ ) content 0.1% (1000) Polybrominated Biphenyls (PBBs) 0.1% (1000) Polybrominated Diphenyl Ethers (PBDEs) 0.1% (1000) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0325496* Page 4 of 12

Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents Reference Method: IEC 62321 edition 1.0:2008 Number: TWNC00325496 For non-metal part Sample preparation For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component PBBs/PBDEs Cr 6+ Cd/Pb/Hg Substrate Plating Weigh sample and add organic solvent Weigh sample and add alkaline solution For different material, digest the sample with appropriate acid *1 Cr 6+ By Soxhlet extraction or Solvent extraction Definite temp. extraction Confirm the tested samples are totally dissolved By spot test Get 50cm 2 sample Negative *2 Concentrate the extract and make up with organic solvent Cool and filter the extract Make up with deionized water By boiling water extraction Analyzed by GC-MS Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3,HCl,HF,H 2 O 2,H 3 BO 3 Metals HNO 3,HCl,HF Electronics HNO 3,HCl,H 2 O 2,HBF 4 Analyzed by UV-VIS *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0325496* Page 5 of 12

Measurement Flowchart: Test for Heavy Metal (Sb) Contents Reference Method:USEPA 3052 Number: TWNC00325496 Sampling Weigh sample and digest in microwave digestion oven with suitable acid Confirm the tested samples are totally dissolved Transfer the digested solution and make up with deionized water Analyzed by ICP-OES *THJ0325496* Page 6 of 12

Test for Halogen Contents Reference Method:EN 14582 Number: TWNC00325496 Sampling Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography *THJ0325496* Page 7 of 12

Test for Phthalates Contents Reference Method: EN 14372: 2004 Test Report Sampling Number: TWNC00325496 Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MS *THJ0325496* Page 8 of 12

Test for Hexabromocyclododecane (HBCDD) Content Reference Method:USEPA 3540C Test Report Number: TWNC00325496 Sampling Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MS *THJ0325496* Page 9 of 12

Number: TWNC00325496 End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for anyparticular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and onlyaccepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes nowarranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conductthe Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0325496* Page 10 of 12

Number : TWNC00325498 Applicant: Littelfuse, S.A. de C.V. Date : Aug 01, 2013 Blvd. Fausto Z. Martinez #1800 Col. Magisterio Seccion 38 C.P. 26070 Piedra Negras, Coahuila, Mexico Sample Description: One (1) group of submitted samples said to be : Part Description : Colorant-Brown Part Number : 057878 Date Sample Received : Jul 30, 2013 Date Test Started : Jul 30, 2013 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0325498* Page 1 of 12

Number: TWNC00325498 Test Result Summary: Test Item Unit Test Method Result Brown plastic pellets RL Heavy Metal With reference to IEC 62321: Cadmium (Cd) content 2008, by microwave digestion ND 2 and determined by ICP-OES. With reference to IEC 62321: Lead (Pb) content 2008, by microwave digestion ND 2 and determined by ICP-OES. With reference to IEC 62321: Mercury (Hg) content 2008, by microwave digestion ND 2 and determined by ICP-OES. With reference to USEPA 3052, Antimony (Sb) Content by microwave digestion and ND 2 determined by ICP-OES. With reference to IEC 62321: Chromium VI (Cr 6+ ) content 2008, by alkaline digestion and determined by UV-Vis ND 1 Spectrophotometer. Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) With reference to IEC 62321: Pentabrominated Biphenyls 2008, by solvent extraction (PentaBB) and determined by GC-MS and Hexabrominated Biphenyls further HPLC-DAD confirmation (HexaBB) when necessary. Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) *THJ0325498* Page 2 of 12

Number: TWNC00325498 Test Item Unit Test Method Result Brown plastic pellets RL Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) With reference to IEC 62321: Pentabrominated Diphenyl 2008, by solvent extraction Ethers (PentaBDE) and determined by GC-MS and Hexabrominated Diphenyl further HPLC-DAD confirmation Ethers (HexaBDE) when necessary. Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) With reference to EN 0 Chlorine (Cl) 14582:2007 by calorimetric 0 bomb with oxygen and Bromine (Br) 0 determined by Ion Iodine (I) Chromatograph. 0 Phthalates Di(2-ethylhexyl) Phthalate (DEHP) ND 10 Dibutyl Phthalate With reference to EN 14372: ND 10 (DBP) 2004, by solvent extraction Benzyl Butyl Phthalate and determined by GC-MS. ND 10 (BBP) Diisobutyl Phthalate (DIBP) ND 10 *THJ0325498* Page 3 of 12

Number: TWNC00325498 Others Test Item Unit Test Method Hexabromocyclododecane (HBCDD) With reference to USEPA 3540C, by solvent extraction and determined by GC-MS. Result Brown plastic pellets RL ND 10 Remarks: = parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample Responsibility of Chemist: Kevin Liu/ Irene Chiou/ Vico Lin Date Sample Received : Jul 30, 2013 Test Period : Jul 30, 2013 To Aug 01, 2013 RoHS Limit Restricted Substances Limits Cadmium (Cd) content 0.01% (100) Lead (Pb) content 0.1% (1000) Mercury (Hg) content 0.1% (1000) Chromium VI (Cr 6+ ) content 0.1% (1000) Polybrominated Biphenyls (PBBs) 0.1% (1000) Polybrominated Diphenyl Ethers (PBDEs) 0.1% (1000) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0325498* Page 4 of 12

Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents Reference Method: IEC 62321 edition 1.0:2008 Number: TWNC00325498 For non-metal part Sample preparation For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component PBBs/PBDEs Cr 6+ Cd/Pb/Hg Substrate Plating Weigh sample and add organic solvent Weigh sample and add alkaline solution For different material, digest the sample with appropriate acid *1 Cr 6+ By Soxhlet extraction or Solvent extraction Definite temp. extraction Confirm the tested samples are totally dissolved By spot test Get 50cm 2 sample Negative *2 Concentrate the extract and make up with organic solvent Cool and filter the extract Make up with deionized water By boiling water extraction Analyzed by GC-MS Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3,HCl,HF,H 2 O 2,H 3 BO 3 Metals HNO 3,HCl,HF Electronics HNO 3,HCl,H 2 O 2,HBF 4 Analyzed by UV-VIS *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0325498* Page 5 of 12

Measurement Flowchart: Test for Heavy Metal (Sb) Contents Reference Method:USEPA 3052 Number: TWNC00325498 Sampling Weigh sample and digest in microwave digestion oven with suitable acid Confirm the tested samples are totally dissolved Transfer the digested solution and make up with deionized water Analyzed by ICP-OES *THJ0325498* Page 6 of 12

Test for Halogen Contents Reference Method:EN 14582 Number: TWNC00325498 Sampling Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography *THJ0325498* Page 7 of 12

Test for Phthalates Contents Reference Method: EN 14372: 2004 Test Report Sampling Number: TWNC00325498 Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MS *THJ0325498* Page 8 of 12

Test for Hexabromocyclododecane (HBCDD) Content Reference Method:USEPA 3540C Test Report Number: TWNC00325498 Sampling Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MS *THJ0325498* Page 9 of 12

Number: TWNC00325498 End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for anyparticular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and onlyaccepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes nowarranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conductthe Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0325498* Page 10 of 12

Number : TWNC00325499 Applicant: Littelfuse, S.A. de C.V. Date : Aug 01, 2013 Blvd. Fausto Z. Martinez #1800 Col. Magisterio Seccion 38 C.P. 26070 Piedra Negras, Coahuila, Mexico Sample Description: One (1) group of submitted samples said to be : Part Description : Colorant-Red Part Number : 057879 Date Sample Received : Jul 30, 2013 Date Test Started : Jul 30, 2013 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0325499* Page 1 of 12

Number: TWNC00325499 Test Result Summary: Test Item Unit Test Method Result Red plastic pellets RL Heavy Metal With reference to IEC 62321: Cadmium (Cd) content 2008, by microwave digestion ND 2 and determined by ICP-OES. With reference to IEC 62321: Lead (Pb) content 2008, by microwave digestion ND 2 and determined by ICP-OES. With reference to IEC 62321: Mercury (Hg) content 2008, by microwave digestion ND 2 and determined by ICP-OES. With reference to USEPA 3052, Antimony (Sb) Content by microwave digestion and ND 2 determined by ICP-OES. With reference to IEC 62321: Chromium VI (Cr 6+ ) content 2008, by alkaline digestion and determined by UV-Vis ND 1 Spectrophotometer. Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) With reference to IEC 62321: Pentabrominated Biphenyls 2008, by solvent extraction (PentaBB) and determined by GC-MS and Hexabrominated Biphenyls further HPLC-DAD confirmation (HexaBB) when necessary. Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) *THJ0325499* Page 2 of 12

Number: TWNC00325499 Test Item Unit Test Method Result Red plastic pellets RL Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) With reference to IEC 62321: Pentabrominated Diphenyl 2008, by solvent extraction Ethers (PentaBDE) and determined by GC-MS and Hexabrominated Diphenyl further HPLC-DAD confirmation Ethers (HexaBDE) when necessary. Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) With reference to EN 0 Chlorine (Cl) 14582:2007 by calorimetric 0 bomb with oxygen and Bromine (Br) 0 determined by Ion Iodine (I) Chromatograph. 0 Phthalates Di(2-ethylhexyl) Phthalate (DEHP) ND 10 Dibutyl Phthalate With reference to EN 14372: ND 10 (DBP) 2004, by solvent extraction Benzyl Butyl Phthalate and determined by GC-MS. ND 10 (BBP) Diisobutyl Phthalate (DIBP) ND 10 *THJ0325499* Page 3 of 12

Number: TWNC00325499 Others Test Item Unit Test Method Hexabromocyclododecane (HBCDD) With reference to USEPA 3540C, by solvent extraction and determined by GC-MS. Result Red plastic pellets RL ND 10 Remarks: = parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample Responsibility of Chemist: Kevin Liu/ Irene Chiou/ Vico Lin Date Sample Received : Jul 30, 2013 Test Period : Jul 30, 2013 To Aug 01, 2013 RoHS Limit Restricted Substances Limits Cadmium (Cd) content 0.01% (100) Lead (Pb) content 0.1% (1000) Mercury (Hg) content 0.1% (1000) Chromium VI (Cr 6+ ) content 0.1% (1000) Polybrominated Biphenyls (PBBs) 0.1% (1000) Polybrominated Diphenyl Ethers (PBDEs) 0.1% (1000) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0325499* Page 4 of 12

Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents Reference Method: IEC 62321 edition 1.0:2008 Number: TWNC00325499 For non-metal part Sample preparation For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component PBBs/PBDEs Cr 6+ Cd/Pb/Hg Substrate Plating Weigh sample and add organic solvent Weigh sample and add alkaline solution For different material, digest the sample with appropriate acid *1 Cr 6+ By Soxhlet extraction or Solvent extraction Definite temp. extraction Confirm the tested samples are totally dissolved By spot test Get 50cm 2 sample Negative *2 Concentrate the extract and make up with organic solvent Cool and filter the extract Make up with deionized water By boiling water extraction Analyzed by GC-MS Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3,HCl,HF,H 2 O 2,H 3 BO 3 Metals HNO 3,HCl,HF Electronics HNO 3,HCl,H 2 O 2,HBF 4 Analyzed by UV-VIS *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0325499* Page 5 of 12

Measurement Flowchart: Test for Heavy Metal (Sb) Contents Reference Method:USEPA 3052 Number: TWNC00325499 Sampling Weigh sample and digest in microwave digestion oven with suitable acid Confirm the tested samples are totally dissolved Transfer the digested solution and make up with deionized water Analyzed by ICP-OES *THJ0325499* Page 6 of 12

Test for Halogen Contents Reference Method:EN 14582 Number: TWNC00325499 Sampling Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography *THJ0325499* Page 7 of 12

Test for Phthalates Contents Reference Method: EN 14372: 2004 Test Report Sampling Number: TWNC00325499 Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MS *THJ0325499* Page 8 of 12

Test for Hexabromocyclododecane (HBCDD) Content Reference Method:USEPA 3540C Test Report Number: TWNC00325499 Sampling Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MS *THJ0325499* Page 9 of 12

Number: TWNC00325499 End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for anyparticular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and onlyaccepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes nowarranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conductthe Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0325499* Page 10 of 12

Number : TWNC00299231 Applicant: Littelfuse, S.A. de C.V. Date : Feb 25, 2013 Blvd. Fausto Z. Martinez #1800 Col. Magisterio Seccion 38 C.P. 26070 Piedra Negras, Coahuila, Mexico Sample Description: One (1) group of submitted samples said to be : Part Description : Color concentrate blue Part Number : 057880 Date Sample Received : Feb 19, 2013 Date Test Started : Feb 19, 2013 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0299231* Page 1 of 10

Number : TWNC00299231 (Ⅰ) Test Result Summary: Heavy Metal Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Test Item Unit Test Method Chromium VI (Cr 6+ ) Content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by alkaline digestion and determined by UV-Vis Spectrophotometer. Result Blue plastic pellets RL ND 2 ND 2 ND 2 ND 1 With reference to IEC 62321: 2008, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary. *THJ0299231* Page 2 of 10

Number : TWNC00299231 Result Test Item Unit Test Method Blue plastic RL pellets Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl With reference to IEC Ethers (TetraBDE) 62321: 2008, by solvent Pentabrominated Diphenyl extraction and Ethers (PentaBDE) determined by GC-MS and Hexabrominated Diphenyl Ethers further HPLC-DAD (HexaBDE) confirmation when Heptabrominated Diphenyl necessary. Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Phthalates Di(2-ethylhexyl) Phthalate With reference to EN (DEHP) 14372: 2004, by solvent 0 Dibutyl Phthalate (DBP) extraction and 0 Benzyl Butyl Phthalate (BBP) determined by GC-MS. 0 Halogen Content Fluorine (F) With reference to EN 0 Chlorine (Cl) 14582:2007 by 0 calorimetric bomb with Bromine (Br) oxygen and determined 0 Iodine (I) by Ion Chromatograph. 0 Others With reference to USEPA Hexabromo cyclododecane 3540C, by solvent (HBCDD) extraction and determined by GC-MS. ND 10 *THJ0299231* Page 3 of 10

Number : TWNC00299231 Remarks: = parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample Responsibility of Chemist: Kevin Liu/ Irene Chiou/ Vico Lin Date Sample Received : Feb 19, 2013 Test Period : Feb 19, 2013 to Feb 21, 2013 (Ⅱ) Limit: RoHS Limit Restricted Substances Limits Cadmium (Cd) content 0.01% (100) Lead (Pb) content 0.1% (1000) Mercury (Hg) content 0.1% (1000) Chromium VI (Cr 6+ ) content 0.1% (1000) Polybrominated Biphenyls (PBBs) 0.1% (1000) Polybrominated Diphenyl Ehters (PBDEs) 0.1% (1000) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0299231* Page 4 of 10

Number : TWNC00299231 (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 For non-metal part Sample preparation For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component PBBs/PBDEs Cr 6+ Cd/Pb/Hg Substrate Plating Weigh sample and add organic solvent Weigh sample and add alkaline solution For different material, digest the sample with appropriate acid *1 Cr 6+ By Soxhlet extraction or Solvent extraction Definite temp. extraction Confirm the tested samples are totally dissolved By spot test Negative *2 Get 50cm 2 sample Concentrate the extract and make up with organic solvent Cool and filter the extract Make up with deionized water By boiling water extraction Analyzed by GC-MSD Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by UV-VIS *THJ0299231* Page 5 of 10

Number : TWNC00299231 Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0299231* Page 6 of 10

Number : TWNC00299231 Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography *THJ0299231* Page 7 of 10

Number : TWNC00299231 Test For Phthalates Contents Reference Method: EN 14372: 2004 Sampling/grinding or cutting Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD *THJ0299231* Page 8 of 10

Number : TWNC00299231 Test For Hexabromocyclododecane (HBCDD) Reference Standard:USEPA 3540C Sampling/grinding or cutting Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0299231* Page 9 of 10

Number : TWNC00299231 Photo *THJ0299231* Page 10 of 10

Number : TWNC00325497 Applicant: Littelfuse, S.A. de C.V. Date : Aug 01, 2013 Blvd. Fausto Z. Martinez #1800 Col. Magisterio Seccion 38 C.P. 26070 Piedra Negras, Coahuila, Mexico Sample Description: One (1) group of submitted samples said to be : Part Description : Colorant-Tan Part Number : 057877 Date Sample Received : Jul 30, 2013 Date Test Started : Jul 30, 2013 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0325497* Page 1 of 12

Number: TWNC00325497 Test Result Summary: Test Item Unit Test Method Result Light brown plastic pellets RL Heavy Metal With reference to IEC 62321: Cadmium (Cd) content 2008, by microwave digestion ND 2 and determined by ICP-OES. With reference to IEC 62321: Lead (Pb) content 2008, by microwave digestion ND 2 and determined by ICP-OES. With reference to IEC 62321: Mercury (Hg) content 2008, by microwave digestion ND 2 and determined by ICP-OES. With reference to USEPA 3052, Antimony (Sb) Content by microwave digestion and ND 2 determined by ICP-OES. With reference to IEC 62321: Chromium VI (Cr 6+ ) content 2008, by alkaline digestion and determined by UV-Vis ND 1 Spectrophotometer. Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) With reference to IEC 62321: Pentabrominated Biphenyls 2008, by solvent extraction (PentaBB) and determined by GC-MS and Hexabrominated Biphenyls further HPLC-DAD confirmation (HexaBB) when necessary. Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) *THJ0325497* Page 2 of 12

Number: TWNC00325497 Test Item Unit Test Method Result Light brown plastic pellets RL Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) With reference to IEC 62321: Pentabrominated Diphenyl 2008, by solvent extraction Ethers (PentaBDE) and determined by GC-MS and Hexabrominated Diphenyl further HPLC-DAD confirmation Ethers (HexaBDE) when necessary. Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) With reference to EN 0 Chlorine (Cl) 14582:2007 by calorimetric 0 bomb with oxygen and Bromine (Br) 0 determined by Ion Iodine (I) Chromatograph. 0 Phthalates Di(2-ethylhexyl) Phthalate (DEHP) ND 10 Dibutyl Phthalate With reference to EN 14372: ND 10 (DBP) 2004, by solvent extraction Benzyl Butyl Phthalate and determined by GC-MS. ND 10 (BBP) Diisobutyl Phthalate (DIBP) ND 10 *THJ0325497* Page 3 of 12

Number: TWNC00325497 Others Test Item Unit Test Method Hexabromocyclododecane (HBCDD) With reference to USEPA 3540C, by solvent extraction and determined by GC-MS. Result Light brown plastic pellets RL ND 10 Remarks: = parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample Responsibility of Chemist: Kevin Liu/ Irene Chiou/ Vico Lin Date Sample Received : Jul 30, 2013 Test Period : Jul 30, 2013 To Aug 01, 2013 RoHS Limit Restricted Substances Limits Cadmium (Cd) content 0.01% (100) Lead (Pb) content 0.1% (1000) Mercury (Hg) content 0.1% (1000) Chromium VI (Cr 6+ ) content 0.1% (1000) Polybrominated Biphenyls (PBBs) 0.1% (1000) Polybrominated Diphenyl Ethers (PBDEs) 0.1% (1000) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0325497* Page 4 of 12

Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents Reference Method: IEC 62321 edition 1.0:2008 Number: TWNC00325497 For non-metal part Sample preparation For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component PBBs/PBDEs Cr 6+ Cd/Pb/Hg Substrate Plating Weigh sample and add organic solvent Weigh sample and add alkaline solution For different material, digest the sample with appropriate acid *1 Cr 6+ By Soxhlet extraction or Solvent extraction Definite temp. extraction Confirm the tested samples are totally dissolved By spot test Get 50cm 2 sample Negative *2 Concentrate the extract and make up with organic solvent Cool and filter the extract Make up with deionized water By boiling water extraction Analyzed by GC-MS Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3,HCl,HF,H 2 O 2,H 3 BO 3 Metals HNO 3,HCl,HF Electronics HNO 3,HCl,H 2 O 2,HBF 4 Analyzed by UV-VIS *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0325497* Page 5 of 12

Measurement Flowchart: Test for Heavy Metal (Sb) Contents Reference Method:USEPA 3052 Number: TWNC00325497 Sampling Weigh sample and digest in microwave digestion oven with suitable acid Confirm the tested samples are totally dissolved Transfer the digested solution and make up with deionized water Analyzed by ICP-OES *THJ0325497* Page 6 of 12

Test for Halogen Contents Reference Method:EN 14582 Number: TWNC00325497 Sampling Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography *THJ0325497* Page 7 of 12

Test for Phthalates Contents Reference Method: EN 14372: 2004 Test Report Sampling Number: TWNC00325497 Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MS *THJ0325497* Page 8 of 12

Test for Hexabromocyclododecane (HBCDD) Content Reference Method:USEPA 3540C Test Report Number: TWNC00325497 Sampling Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MS *THJ0325497* Page 9 of 12

Number: TWNC00325497 End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for anyparticular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and onlyaccepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes nowarranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conductthe Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0325497* Page 10 of 12

Test Reoort Applicant: Litteltuse, S,A, de C.V, Bvd. Fausto Z. Martinez #1800 Col. ltlagisterio Seccion 38 C.P. 26070 Piedra Negras, Coahuila, I\4erico Numb r Date TWNC00322214 Jul 16, 2013 Sample Description: One (1) grcup of submitted samdesaidtobe: Paft Description Green colorant Part Number 0s7883 Date Sample Re{eiled Jul 08, 2013 Date Test Stard Jul 09, 2013 l As requested by the applicant, fior details please refer to attached pages. Authorized byi on Behalf of Intertek Testing S rvices Talwan Limited K, Y. Uang Director Intert k Testlng Services Taiwan Ltd. 8F., No.423, Ruiguang Rd., Nein! Dist ict, Taipei 11492, Taiwan, R.o.c. a@a\;h&e&&i'aprae 114s2 ijlif^ldethrtflf 423 trt I lh T t: l+08e2) 6602,288a 2797-8a85 F3r: (+88F2) 660 2410 llllllllllllllllllllllllllllllilllllllil p"g" 1of 11

Test Reoort Number: TWNC00322214 Test Re$lt Summa Test ltem udt Test lvlethod Result Green olastic oellets B! Heavv Metal Cadmium (Cd) content with reference to IEc 52321: 2008, by mlcrowave digestion ND 2 and determined bv ICP-OES. Lead (Pb) content with reference to IEc 62321: 2008, by microwave digestion ND 2 and determined bv ICP-OES, Mercury (Hg) content With reference to IEC 62321: 2008, by microwave digestion ND 2 and d termined bv ICP-OES. Chromium VI (Cr5*) content With reference to IEC 62321: 2008, by alkaline digestion and determined by UV-Vis SoectroDhotometer. ND 1 Polybrofiinat d Biph nyls (PBB6) Monobrominated Biphenyls al\4onobb) Dlbromhated Biphenyls (DiBB) Tribrominated Biphenyls ftribb) Tetrabrominated Biphenyls fietrabb) Pentabrom jnated Wi$ reference to IEc 62321: Biphenyls (PentaBB) 2008, by solvent extradion and determined by GC-[.{S and Hexabrominated Biphenyls (HexaBB) further HPLC-DAD confirmation wnen ne@ssary, Heptabrominated Biphenyls (HeDtaBB) Octabrominated Blphenyls foctebbl Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) fiilililil1t illtililfl t il]ilililnl Int n k Testng Services Taiwan Ltd. 8F., No.423, Ruiguang Rd., Nsihu Dislricl, Taipei 11,192, Taiwan, R.O.C. a@aaa&&&6 Fa\d 114s26jLfidg{E#}6t6 423 Ai I E Teli(+8aGa 6602-2884 2797{845 Fa* (+846-2) 66@-2410 Page 2 of 11

Number TWNC003222r4 Test ltem Uoit Test l,4ethod Result Green olastic oellets Bt Polybrominated DiDhenyl Ethers (PBDES) Iqonobrominated Diphenyl Ethe6 (N,lonoBDE) Dibrominated Diphenyl Ethe6 (DiBDE) PPM Trlbrominated Diphenyl Ethe6 firibde) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Wth reference to IEC 62321: Ethe$ (PentaBDE) 2008, by solvent extraction and determined Hexabrominated by GC-I4S and Diphenyl fu rther HPLC-DAD Ethers (HexaBDE) confirmation when necessary. Heptabrominated Diphenyl Ethers (HeptaBDE) octabrominated Diphenyl Ethers (OctaBDE) Nonabromlnated Diphenyl Ethers (NonaBDE) Decabrominated Dlphenyl Ether (D c BDE) Haloqen Content Ftuonne (Fl With reference to EN 0 Chlorine (Cl) 14582:2007 by calorimetric 0 bomb wlth oxygen and Bromlne (Br) determined by Ion 0 Iodine {I) 0 Phthalates Di(2-ethylheryl) Phthalate (DEHP'I ND 10 With reference to EN 14372: Dibutyl Phthalate (DBP) 2004, by solvent extraction ND 10 and determined by GC-14S. Benzyl Butyl Phthalate {BBP') ND 10 IntEn k Testlng serulces Telwan Ltd. 8F., No.423, Ruiguang Rd. Neihu Dislricl,Taipei11492, Taiwan, RO C e@a\;a&ffi&ita[r^a 11,192 tjliitrjjfltdiffi)bl* 423!* 8 lf Ter (+88G2) 6602'28s8. 2?9t4485 Fd:(+88&2) 6602'2410 ililllllllllllllllllllllllllllllllll Pase 3 or 11

Test Reoort Number: TWNC00322214 Othe]s Test ltem udt Test Metfiod Hexabromocyclododecane (HBCDD) With reference to USEPA 352()C, by solvent extraction and determined W GC-I\4S. Result Green olastic oellets ND E! l0 Remarks: = pbrts p r million bas d on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample Responsibility of Chemist: Kevin Liu/ Irene Chiou/ Vico Lin Date Sample Received : Ju 08,2013 Test Period i Jul08, 2013 ToJul 12, 2013 RoHS Limit Restricted Substances!i!oG Cadmium (Cd) content 0.01Yo f100oom) Lead (Pb) content 0.1olo (100000m) Mercurv (Ho) content 0.1olo (1000oDm) Chromium VI (Cf') content 0.1olo (1000) Polvbrominated Biohenvls (PBBS) 0.10,6 (1000oDm) Polvbrominated Diohenvl Ethers (PBDES) 0.1% (100000m) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material, Intertek T$ting Services Talwan Ltd. 8F., No. 423, Ruiguang Rd.. Neihu Oistict, Taipei 11492, Taiwan, R.O.C. aelaffi&efii?6 Ke\a 114e2 bjlfidsle i{}c[s 423!fi I E Tel:(+886-a 66m-2888. 279ru885 Fax (+886-2) 6602-2410 lllllllllllllllllllllllllllllllllllllll pase4or 11

Measurement Flowchart: Number: TWNC00322214 Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Refrerence Method: IEC 62321 edition 1.0:2008 Take sarnple and immerse into Aqua Regia, srart to strip plating layer Stop the shg plredure upon (olor change completely Take $e Aqua solution as plating component and stripped body as sub6trate component P8Bs/PADES Y ' I weish sample and add I I ds.nicsor nt ---------------- I Y ' I By Soxhlet ext'aclion or I V ' sotvent extraclion I I t---------------- l I Derlnite temp. I I exbadion ---------------- I Y, I concentrate the ertnct I r l I and make up with oqanic I I cool and filter the I I ---------------- extect I l s o ' v e n t l - v r (_ t"'t*,t - "t, V r,4ake up v/ith deionized wat r and add diphenyl dazid Remarks: *1r List ol Acid It4aterial Acid Added for Dioestion HNO1,HCI,HF,H'O',H1BO1 lletals HNOT,HCI,HF Electronics HNOT,HCI,H,O,,HBF. *2: If the result of spot test is posiuve, Chromium VI would be determined as detected. Intertek lesting sewices Taiwan Ltd. 8F., No.423, Ruiouano Rd., N6ihu Dislricl, rsip6i 11492, Taiwan, R.O.C. a@^\a&e{^[e'i? FR^\FJ 11492 fijb rjrfjjlflld.ftxeg 423 li 8 ig l [ (+88e2) 6602-28a8. 2797-8485 Fsr: (+68F2) 6602-2410 l[lll]illlilllllllllll ]lllllllilllll Paee s or 11

Test for Halogen Contents Reference l4ethod : EN 14582 Ir$-Berglt Number: TWNC00322214 Md absoftent in a combustion flask & place weighed sample in equipment Transtur the absorb nt into a volumetric flask t4ake up with deionized water Analyzed by ion chromatography uililililililil]ilililil ilt!tl htenek T stlng Servlces Tilwan Ltd. 8F., No,423, Ruiguang Rd.. Neihu Dislrict, Taipei 11492. Taiwan, R.O.C. a@a-a&&&toaf^e 114e2 rljlfi/streitttt* 423 fr 3 E Tel:{+88G2)6602-2884 2797{845 Fd:(+84&2)66@-2410 Page 6 of 11

T st Reoort T st Conducd Test for Phthalatescontents Reference! ethod: EN 14372: 2004 Number: TWNC00322214 Weigh sample and add organic solvent By solvent extradion Concentrate the extrad and make up with organic solvent Analyzed by GC-MS Intertet T8ting Sewlces Talwan Ltd. 8F,, No. 423, Ruigusng Rd., Neihu Districi, Taipei 11492, Taiwan, R.o.c. effia;f&ffi&i,) FEa\d 11492 AJt fi 'j*eefty6ld# 423 ffi I B Teli (+88S2) 6602-2888. 279ru885 Fax (+88&2)6602-2410 lli illlllllllllllillllllllllllllllllllil pase 7 or 11

Test Reoort Test Conduded Test for HgGbromocyclododecane (HBCDD) Content Reference Method : USEPA 3540C Number: TWNC00322214 Analyzed by GC-llS Intertek Testins Services Taiwan Ltd. 8F., No. 423. Ruiquang Rd,, Neihu District, Taip i 11492, Taiwan, R.O.C. a@atr&&&.tt [Fa-d 114926.]1fid$!Eg$*t$ 423 l,t 0 {q TeI (+88G2) 6602-2888. 2797{885 Fax (+88G2) 6602-2410 illlllfl llllllllilllllllllllllllllllllll Page I of 11

Test Reoort Numt'er: TWNC00322214 (o lo I crt (\, FI o 0 1 23 4 5 6 7 I End of Report thebtteztd.elayenebq,af d!t *1tdiwar{arffini@edkateftrt awld byw ItE t1.fkfje bb.. @naiadd t*arlendrta.@oracrn. Ltf'tr,lk tu d ett 2 d6/ or@ q 4 cdts t e@ew b tr res ods tan tu b du.dte @@ e a diet tu M bds tu M tu Maapt a.t, ranty b tnu h,ey hs diw M of q n tu M tu @t lndix'6r'byfugee4.xqlbfufudfug 6.4l9mddfuM htertek T6ting Seryicas Taiwan Ltd. 8F,No 423, Rligua.q Rd. Nehu D stnd, Taipei11492, Taiwan, R O C +El'a\#t&Efi ief6 [Et1d 114s2 h)1fi,'ttstu;tbwn 4x M 3 t4 Tel (+886.2) 6602-2888. 2797-E885 F8x {+E86-2) 6602-2410 lllllllllllllilllllllllllllltrlllllllllllll p"s" g tt "r

Number : TWNC00299232 Applicant: Littelfuse, S.A. de C.V. Date : Feb 25, 2013 Blvd. Fausto Z. Martinez #1800 Col. Magisterio Seccion 38 C.P. 26070 Piedra Negras, Coahuila, Mexico Sample Description: One (1) group of submitted samples said to be : Part Description : COLOR CONCENTRATE ORANGE Part Number : 057884 Date Sample Received : Feb 19, 2013 Date Test Started : Feb 19, 2013 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0299232* Page 1 of 10

Number : TWNC00299232 (Ⅰ) Test Result Summary: Heavy Metal Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Test Item Unit Test Method Chromium VI (Cr 6+ ) Content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by alkaline digestion and determined by UV-Vis Spectrophotometer. Result Dark orange plastic pellets RL ND 2 ND 2 ND 2 ND 1 With reference to IEC 62321: 2008, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary. *THJ0299232* Page 2 of 10

Number : TWNC00299232 Result Test Item Unit Test Method Dark orange plastic RL pellets Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl With reference to IEC Ethers (TetraBDE) 62321: 2008, by solvent Pentabrominated Diphenyl extraction and Ethers (PentaBDE) determined by GC-MS and Hexabrominated Diphenyl Ethers further HPLC-DAD (HexaBDE) confirmation when Heptabrominated Diphenyl necessary. Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Phthalates Di(2-ethylhexyl) Phthalate With reference to EN (DEHP) 14372: 2004, by solvent 0 Dibutyl Phthalate (DBP) extraction and 0 Benzyl Butyl Phthalate (BBP) determined by GC-MS. 0 Halogen Content Fluorine (F) With reference to EN 0 Chlorine (Cl) 14582:2007 by 3595 50 calorimetric bomb with Bromine (Br) oxygen and determined 0 Iodine (I) by Ion Chromatograph. 0 Others With reference to USEPA Hexabromo cyclododecane 3540C, by solvent (HBCDD) extraction and determined by GC-MS. ND 10 *THJ0299232* Page 3 of 10

Number : TWNC00299232 Remarks: = parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample Responsibility of Chemist: Kevin Liu/ Irene Chiou/ Vico Lin Date Sample Received : Feb 19, 2013 Test Period : Feb 19, 2013 to Feb 21, 2013 (Ⅱ) Limit: RoHS Limit Restricted Substances Limits Cadmium (Cd) content 0.01% (100) Lead (Pb) content 0.1% (1000) Mercury (Hg) content 0.1% (1000) Chromium VI (Cr 6+ ) content 0.1% (1000) Polybrominated Biphenyls (PBBs) 0.1% (1000) Polybrominated Diphenyl Ehters (PBDEs) 0.1% (1000) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0299232* Page 4 of 10

Number : TWNC00299232 (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 For non-metal part Sample preparation For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component PBBs/PBDEs Cr 6+ Cd/Pb/Hg Substrate Plating Weigh sample and add organic solvent Weigh sample and add alkaline solution For different material, digest the sample with appropriate acid *1 Cr 6+ By Soxhlet extraction or Solvent extraction Definite temp. extraction Confirm the tested samples are totally dissolved By spot test Negative *2 Get 50cm 2 sample Concentrate the extract and make up with organic solvent Cool and filter the extract Make up with deionized water By boiling water extraction Analyzed by GC-MSD Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by UV-VIS *THJ0299232* Page 5 of 10

Number : TWNC00299232 Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0299232* Page 6 of 10

Number : TWNC00299232 Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography *THJ0299232* Page 7 of 10

Number : TWNC00299232 Test For Phthalates Contents Reference Method: EN 14372: 2004 Sampling/grinding or cutting Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD *THJ0299232* Page 8 of 10

Number : TWNC00299232 Test For Hexabromocyclododecane (HBCDD) Reference Standard:USEPA 3540C Sampling/grinding or cutting Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0299232* Page 9 of 10

Number : TWNC00299232 Photo *THJ0299232* Page 10 of 10

Number : TWNC00331293 Applicant: Littelfuse, S.A. de C.V. Date : Sep 14, 2013 Blvd. Fausto Z. Martinez #1800 Col. Magisterio Seccion 38 C.P. 26070 Piedra Negras, Coahuila, Mexico Sample Description: One (1) group of submitted samples said to be : Part Description : YELLOW COLORANT Part Number : 057899 Date Sample Received : Sep 10, 2013 Date Test Started : Sep 10, 2013 to Sep 13, 2013 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0331293* Page 1 of 12

Number: TWNC00331293 Test Result Summary: Test Item Unit Test Method Result Orange plastic pellets RL Heavy Metal Cadmium (Cd) content With reference to IEC 62321: 2008, by microwave digestion ND 2 and determined by ICP-OES. Lead (Pb) content With reference to IEC 62321: 2008, by microwave digestion ND 2 and determined by ICP-OES. Mercury (Hg) content With reference to IEC 62321: 2008, by microwave digestion ND 2 and determined by ICP-OES. Antimony (Sb) Content With reference to USEPA 3052, by microwave digestion and ND 2 determined by ICP-OES. Chromium VI (Cr 6+ ) content With reference to IEC 62321: 2008, by alkaline digestion and determined by UV-Vis Spectrophotometer. ND 1 Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) With reference to IEC 62321: Pentabrominated Biphenyls 2008, by solvent extraction (PentaBB) and determined by GC-MS and Hexabrominated Biphenyls further HPLC-DAD confirmation (HexaBB) when necessary. Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) *THJ0331293* Page 2 of 12

Number: TWNC00331293 Test Item Unit Test Method Result Orange plastic pellets Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) With reference to IEC 62321: Pentabrominated Diphenyl 2008, by solvent extraction Ethers (PentaBDE) and determined by GC-MS and Hexabrominated Diphenyl further HPLC-DAD confirmation Ethers (HexaBDE) when necessary. Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) With reference to EN 0 Chlorine (Cl) 14582:2007 by combustion 0 bomb with oxygen and Bromine (Br) 0 determined by Ion Iodine (I) Chromatography. 0 Phthalates Di(2-ethylhexyl) Phthalate (DEHP) ND 10 Dibutyl Phthalate With reference to EN 14372: ND 10 (DBP) 2004, by solvent extraction Benzyl Butyl Phthalate and determined by GC-MS. ND 10 (BBP) Diisobutyl phthalate (DIBP) ND 10 Others With reference to USEPA Hexabromocyclododecane 3540C, by solvent extraction (HBCDD) and determined by GC-MS. ND 10 RL *THJ0331293* Page 3 of 12

Number: TWNC00331293 Remarks: = parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample Responsibility of Chemist: Kevin Liu/ Irene Chiou/ Vico Lin Date Sample Received : Sep 10,2013 Test Period : Sep 10,2013 to Sep 13,2013 RoHS Limit Restricted Substances Limits Cadmium (Cd) content 0.01% (100) Lead (Pb) content 0.1% (1000) Mercury (Hg) content 0.1% (1000) Chromium VI (Cr 6+ ) content 0.1% (1000) Polybrominated Biphenyls (PBBs) 0.1% (1000) Polybrominated Diphenyl Ethers (PBDEs) 0.1% (1000) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0331293* Page 4 of 12

Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents Reference Method: IEC 62321 edition 1.0:2008 Number: TWNC00331293 For non-metal part Sample preparation For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component PBBs/PBDEs Cr 6+ Cd/Pb/Hg Substrate Plating Weigh sample and add organic solvent Weigh sample and add alkaline solution For different material, digest the sample with appropriate acid *1 Cr 6+ By Soxhlet extraction or Solvent extraction Definite temp. extraction Confirm the tested samples are totally dissolved By spot test Get 50cm 2 sample Negative *2 Concentrate the extract and make up with organic solvent Cool and filter the extract Make up with deionized water By boiling water extraction Analyzed by GC-MS Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3,HCl,HF,H 2 O 2,H 3 BO 3 Metals HNO 3,HCl,HF Electronics HNO 3,HCl,H 2 O 2,HBF 4 Analyzed by UV-VIS *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0331293* Page 5 of 12

Measurement Flowchart: Test for Heavy Metal (Sb) Contents Reference Method:USEPA 3052 Number: TWNC00331293 Sampling Weigh sample and digest in microwave digestion oven with suitable acid Confirm the tested samples are totally dissolved Transfer the digested solution and make up with deionized water Analyzed by ICP-OES *THJ0331293* Page 6 of 12

Measurement Flowchart: Test for Halogen Contents Reference Method:EN 14582 Number: TWNC00331293 Sampling Add absorbent in a combustion bomb & place weighed sample into sample cup Fill oxygen into the combustion bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by Ion Chromatography *THJ0331293* Page 7 of 12

Measurement Flowchart: Test for Phthalates Contents Reference Method: EN 14372: 2004 Number: TWNC00331293 Sampling Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MS *THJ0331293* Page 8 of 12

Measurement Flowchart: Test for Hexabromocyclododecane (HBCDD) Content Reference Method:USEPA 3540C Number: TWNC00331293 Sampling Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MS *THJ0331293* Page 9 of 12

Number: TWNC00331293 End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for anyparticular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and onlyaccepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes nowarranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conductthe Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0331293* Page 10 of 12