Author. Abstract. Introduction

Similar documents
Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

A Direct 5 ms Column Performance Comparison for Active Semi-Volatile Analytes

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

U.S. EPA Method 8270 for multicomponent analyte determination

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application

Solid Phase Micro Extraction of Flavor Compounds in Beer

Application. Gas Chromatography February Introduction

Validation of USEPA Method Using a Stratum PTC and the New AQUATek 100 Autosampler

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Validation of USEPA Method Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

Rapid Analysis of Food and Fragrances Using High-Efficiency Capillary GC Columns. Application. Authors. Abstract. Introduction

Application. Gas Chromatography March 1998

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

Pesticides Analysis Using the Agilent 5977A Series GC/MSD

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Validation of USEPA Method 8260C Using Teledyne Tekmar Atomx, and Perkin-Elmer Clarus 600 GC/MS

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Analysis of Volatile Organic Compounds Using USEPA Method 8260 and the 4760 Purge and Trap and the 4100 Autosampler

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

U.S. EPA VOLATILE ORGANICS METHOD USING PURGE AND TRAP GC/MS

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Optimization of 1,4-Dioxane and Ethanol Detection Using USEPA Method 8260 Application Note

GC Analysis of Polybrominated Flame Retardants Application

Analysis of Natural Oils and Extracts Using the Low Thermal Mass LTM Series II System

Fast Analysis of USP 467 Residual Solvents using the Agilent 7890A GC and Low Thermal Mass (LTM) System

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Using Hydrogen as An Alternative Carrier Gas for US EPA 8260

US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS

System and JUREK ANNE. Introduction: in an in purge and. trap sampling. Discussion: As part of. consistent and reliable data. (MoRT) to.

Optimizing of Volatile Organic Compound Determination by Static Headspace Sampling

Highly Sensitive and Rugged GC/MS/MS Tool

Application Note. Abstract. Authors. Introduction

US EPA Method with the Tekmar Lumin P&T Concentrator, AQUATek LVA and Agilent 7890B GC/5977A MS

Methanol Extraction of high level soil samples by USEPA Method 8260C

Selection of a Capillary GC Column

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

Application. Authors. Abstract. Introduction. Hydrocarbon Processing

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Agilent J&W PoraBOND Q PT Analyzes Oxygenates in Mixed C4 Hydrocarbon Streams by GC/FID and GC/MSD

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Selection of a Capillary

Characterization and Classification of Heroin from Illicit Drug Seizures Using the Agilent 7200 GC/Q-TOF

Automated Characterization of Compounds in Fire Debris Samples

Maximizing Sample Throughput In Purge And Trap Analysis

Analysis. Introduction: necessary. presented. Discussion: As part of be carried. consistent and reliable data. (MoRT) to.

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

Application Note. Abstract. Authors. Environmental

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

INNOVATIVE PRODUCTS, SUPERIOR SUPPORT. Presenter: Anne Jurek, Senior Applications Chemist, EST Analytical

Enhanced Sensitivity for Biomarker Characterization in Petroleum Using Triple Quadrupole GC/MS and Backflushing

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

ENVIRONMENTAL analysis

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Spring 2010 updated March 24 Determination of Aromatics in Gasoline by Gas Chromatography- Mass Spectrometry: Comparison of Grades and Brands

Determination of EU-Banned Disperse Dyes by LC/MSD TOF Application

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Signal, Noise, and Detection Limits in Mass Spectrometry

CEE 772: Instrumental Methods in Environmental Analysis

CEE 772: Instrumental Methods in Environmental Analysis

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

Secrets of GC Column Dimensions

Agilent G2350A Atomic Emission Detector (AED)

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Validation of Volatile Organic Compound by USEPA. Method 8260C. Application Note. Abstract. Introduction. Experimental-Instrument Conditions

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

Detection of Chemical Warfare Agents by Transportable GC/MS

Transcription:

Improved Performance for the Analysis of Aromatics in Gasoline by ASTM Method D5769 Using the Agilent 5973 inert Gas Chromatography/Mass Spectrometry System Application Author James D. McCurry Agilent Technologies, Inc. 285 Centerville Road Wilmington, DE 1988-161 USA Abstract The new Agilent 5973 inert gas chromatography/mass spectrometry system can be used to measure high concentrations of aromatic compounds in gasoline using American Society of Testing and Materials Method D5769. This system provides improved linear calibrations when equipped with the optional extended linearity ion source kit. This makes Method D5769 easier and faster to set up, with more reliable results. The Agilent 5973 inert with the extended linearity source was also shown to quickly and easily pass the D5769 method performance tests for resolution, sensitivity, and spectral integrity. Introduction The levels of aromatic compounds in gasoline are adjusted upward or downward by refiners to comply with environmental regulations and to improve the properties and performance of the finished product. Due to the complex hydrocarbon matrix, it is difficult to chromatographically separate all aromatics from the other nonaromatic hydrocarbons. The American Society of Testing and Materials (ASTM International) has developed Method D5769 that uses gas chromatography/mass spectrometry (GC/MS) to quickly separate, identify, and quantitate benzene, toluene, other specific and total aromatic hydrocarbons in gasoline [1]. This method is designed to measure these compounds between.1 and 42 weight percent. One difficulty encountered when using Method D5769 is obtaining linear calibrations for compounds at concentrations higher than 1 weight percent. Modern GC/MS systems are designed to provide extremely low analytical sensitivity (ppm to ppb), with linear response over several orders of magnitude. However, when trying to analyze compounds at percent levels, the mass spectrometer electron ionization (EI) source can be saturated with sample, resulting in a nonlinear response over a relatively narrow concentration range. There are a number of remedies to this issue that include custom mass spectrometer tuning, time programmed interface splitters, very small injections (<1 µl), very large split ratios (>15:1), nonlinear curve fitting, and a specialized inlet pressure program [2]. These can be used individually or in combinations to meet the calibration requirements of the ASTM method. However, these approaches significantly add to the complexity of a method that is already very complex to successfully set up and run. The best solution to a detector response problem would be to have an EI source that is designed specifically for enhanced linearity.

The new Agilent Technologies 5973 inert GC/MS system has an EI source, constructed of a solid inert material, to provide high sensitivity for difficult samples containing pesticides, nitrophenols, and active sulfur compounds. At first glance, an instrument with this degree of sensitivity would not have the required linear dynamic range necessary to analyze aromatics in gasoline using Method D5769. However, the Agilent 5973 inert GC/MS system offers an optional extended linearity source kit that provides greater linear dynamic range for major compound analysis. This application note will demonstrate the improved performance of Method D5769 using this system. Experimental The Agilent 5973 inert GC/MS system components used for this work are outlined in Table 1. Analysis conditions were set exactly as described by Method D5769 and are shown in Table 2. The ChemStation Autotune program was used to tune the Agilent 5973 inert. No changes were made to the electron multiplier voltage obtained by Autotune. Method D5769 calibration standards were obtained from Accustandard (125 Market Street, New Haven, CT, USA). These standards contained all 23 aromatic compounds specified by the ASTM Table 1. Agilent 5973inert GC/MS hardware G1778A 5973inert with standard turbo pump and ChemStation G2589-245 Ultra large aperture drawout plate for extended linearity source G1942N 689N GC with capillary inlet and mass spectrometer direct capillary interface G2613A Agilent 7683 Automatic Liquid Injector (ALS) with nanoliter adapter G2614A 1-sample tray for ALS Columns Capillary column Consumables Syringe Inlet liner Agilent 5973inert Hardware Configuration for ASTM Method D5769 1 µm film HP-1, 6 m.25 mm id (Agilent part number 1991Z-236) 1 µl fixed needle (Agilent part number 5181-1267) Split optimized, low pressure drop liner (Agilent part number 5183-4647) Table 2. GC Conditions Carrier gas Conditions for the GC/MS Analysis of Aromatics in Gasoline by ASTM Method D5769 method along with four deuterated internal standards; benzene-d6, toluene-d9, ethylbenzene-d1, and naphthalene-d8. The calibration standards were used to construct a five-point calibration curve using the quantitation ions specified for each compound by the ASTM method. Other system performance tests for chromatographic resolution, mass spectral integrity, and sensitivity were performed using samples obtained from Accustandard that met ASTM Method D5769 requirements. Results and Discussion Helium at 28.5 psig constant pressure mode 35 cm/s average linear velocity at 5 C Inlet Capillary at 25 C 25:1 split ratio Oven temp 6 C ( min) 3 C/min to 12 C ( min) 1 C/min to 25 C ( min) Injection size.2 µl using a 1-µL syringe Mass Spectrometer Conditions GC/MS Interface Direct capillary at 28 C Ion source 25 C Quadrupole 15 C Solvent delay 3 min. Electron energy 7 ev Emission current 35 amps Scan range 45 to 3 Daltons Sampling rate 2 3 A/D Scan speed 2.89 scans/s Autotune Standard Since ASTM Method D5769 is a complex application, there are a number of system measures that must be met before calibration and sample analysis. First, the chromatographic resolution was tested under normal operating conditions using 1-methyl-2-ethylbenzene and 1,3,5-trimethylbenzene at 3 mass % each. The resolution between these two peaks must be greater than 2. Figure 1 shows that the resolution between these two compounds was 6.5 using the Agilent 5973 inert system, therefore exceeding the method requirements. 2

For a.1 mass % sample of 1,4-diethylbenzene, the signal-to-noise ratio must be at least 5 at mass 134. This sample was run with the Agilent 5973 inert system and the signal-to-noise ratio (peak-to-peak) was found to be 21. 35 3 1-Methyl-2-ethylbenzene 21.27 min 1,3,5-Trimethylbenzene 21.79 min 25 Abundance 2 15 1 R = 6.5 5 21. 21.2 21.4 21.6 21.8 22. 22.2 min. Figure 1. The chromatographic resolution between 1-Methyl-2-ethybenzene and 1,3,5-Trimethylbenzene exceeds the minimum requirement of 2. specified by ASTM method D5769. The mass spectral integrity performance was measured by running a 3 mass % sample of 1,2,3-trimethybenzene. The spectrum of this compound must meet certain mass and relative abundance criteria to assure that the instrument is properly tuned and functioning. Figure 2 shows that this test was successfully met using the enhanced linearity Agilent 5973 inert. 1 15 9 Relative intensity 8 7 6 5 4 Ion (m/z) 12 15 91 Relative intensity ASTM Spec Agilent 5973inert 3 _ 6 45 1 1 7 _ 15 1 12 3 2 1 77 91 51 63 115 59 4 5 6 7 8 9 1 11 12 m/z Figure 2. For a 3 mass % of 1,2,3-trimethylbenzene sample, the spectral integrity requirements of the ASTM D5769 method are met using the Agilent 5973inert enhanced linearity source. 3

Calibration of the system was performed with standards containing 23 analytical compounds and four deuterated internal standards. The resulting five-point calibration curves for each aromatic compound spanned concentrations in gasoline of.1 to 42 weight percent. Figure 3 shows a total ion chromatogram (TIC) for one of these standard mixes. 1.6e+7 Toluene 1.4e+7 1.2e+7 Abundance 1e+7 8.e+6 6.e+6 4.e+6 2.e+6 Benzene Benzene-d6 Toluene-d8 Ethylbenzene-d1 Ethylbenzene m,p-xylene o-xylene 1-Methylethylbenzene n-propylbenzene 1-Methyl-3-ethylbenzene 1-Methyl-4-ethylbenzene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,2,3-Trimethylbenzene Indan n-butylbenzene 1,2,-Diethylbenzene 1,2,4-Tetramethylbenzene 1,2,4,5-Tetramethylbenzene Naphthalene-d8 Naphthalene 2-Methylnaphthalene 1-Methylnaphthalene 8. 1. 12. 14. 16. 18. 2. 22. 24. 26. 28. 3. min. Figure 3. TIC of a calibration standard containing all 23 analytical compounds and four internal standards for the analysis of aromatics in gasoline. 4

Reconstructed ion chromatograms (RIC) were made from characteristic ions for each calibrated compound. These RICs were integrated and the responses used to construct the calibration curves for each compound. Using conventional, highsensitivity ion sources, the high-concentration standards can saturate the ion source, resulting in a flat or non-linear response for that compound. This effect is shown in Figure 4 for a 1 weight percent standard of toluene. In the upper chromatogram, the toluene RIC peak (m/z 91) shows a flat top, indicating that the ion source contains too much toluene. However, by simply switching to the Agilent 5973 inert extended linearity source, the same toluene standard has the expected peak shape and response. This is shown in the lower chromatogram of Figure 4. Ion source saturation 8 Abundance 6 4 2 Toluene (Ion 91) standard source 1.95 11. 11.5 11.1 11.15 11.2 min. 8 Abundance 6 4 2 Toluene (Ion 91) enhanced linearity source 1.95 11. 11.5 11.1 11.15 11.2 min. Figure 4. RIC of m/z 91 for the analysis of toluene. The upper chromatogram was obtained with the high sensitivity source of the Agilent 5973inert system. The lower chromatogram shows the same standard run using an Agilent 5973inert equipped with an enhanced linearity source. 5

The result of this ion source saturation was calibration curves that do not meet the ASTM Method D5769 linearity specification. This problem was completely overcome when using the Agilent 5973 inert extended linearity source. Figure 5 shows a comparison of toluene calibration for the two different source designs on the Agilent 5973 inert. A. Standard Agilent 5973inert source B. Enhanced linearity Agilent 5973inert source Figure 5. Two toluene calibrations for ASTM Method D5769. A) the standard source does not meet the ASTM method requirements for linearity. B) using the enhanced linearity source, the requirements are easily achieved for toluene. 6

Conclusion The new Agilent 5973 inert equipped with the optional extended linearity source kit was shown to meet or exceed all performance measures for the analysis of aromatics in gasoline by ASTM Method D5769. By quickly and easily obtaining linear calibration curves for percent level components, analysts using this method do not have to apply complex remedies such as specialized tuning, time programmed interface splitters, very small injections, very large split ratios, non-linear curve fitting, and specialized inlet pressure programs. More time can be spent running samples and producing analytical results. References 1. Annual Book of ASTM Standards, Vol. 5.3 Petroleum Products and Lubricants (III), D 4928 - D 595, ASTM, 1 Bar Harbor Drive, West Conshohocken, PA 19428 USA. 2. Leibrand, Roger J., Latest Enhancements to the GC/MS Analysis of Gasoline by ASTM Method D-5769, Agilent Technologies publication 5966-2798E, December 1999. www.agilent.com/chem For More Information For more information on our products and services, visit our Web site at www.agilent.com/chem. 7

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc. 23 Printed in the USA October 13, 23 5989-93EN