Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Similar documents
Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Dionex IonPac AS28-Fast-4µm column

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Determination of trace anions in concentrated hydrofluoric acid

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Determination of Organic Acids in Beer Samples Using a High-Pressure Ion Chromatography System

Inline sample preparation for the determination of anions in sodium hydroxide

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

Determinations of Heat Stable Amine Salts and Amines in Amine Scrubbing Solutions Using Suppressed Conductivity and Charge Detection

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

columns IonPac AS17-C Anion Exchange Column

Thermo Scientific. Anion-Exchange Column

columns IonPac AS18 Anion-Exchange Columns

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

Determination of Adsorbable Organic Halogen in Wastewater

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Determination of silicate in high-purity water using ion chromatography and online sample preparation

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

Expanded capabilities in ammonium and amine detection

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

columns IonPac AS22 Anion-Exchange Column

Determination of trace anions in high-nitrate matrices by ion chromatography

Utility of the Charge Detector in Ion Chromatography Applications

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography

anion-exchange column

Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column

Determination of urea in ultrapure water by IC-MS/MS

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Determination of trace anions in organic solvents using matrix elimination and preconcentration

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA

Determination of trace anions in basic solutions by single pass AutoNeutralization and ion chromatography

The determination of trace anions in concentrated phosphoric acid

Thermo Scientific Dionex eluent suppressors for ion chromatography

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column

Direct Determination of Small Organic Acids in Sea Water by IC-MS

Application of Eluent Generation for Trace Anion Analysis of Borated Waters

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Determination of an anionic fluorochemical surfactant in a semiconductor etch bath

Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters

Determination of Methylamine in Drug Products

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

The Determination of Trace Anions in Concentrated Phosphoric Acid

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column

Determination of trace concentrations of oxyhalides and bromide in municipal and bottled waters

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm)

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

suppressors Eluent Suppressors for Ion Chromatography

The power to increase productivity. Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities

Determination of chlorine, bromine, and sulfur in polyethylene materials using combustion IC with a carbonate/bicarbonate eluent

suppressors SRS -ULTRA Self-Regenerating Suppressor

Determination of Trace Cations in Concentrated Acids Using AutoNeutralization Pretreatment and Ion Chromatography

Determination of Trace Anions in Organic Solvents

Determination of adsorbable organic halogen in wastewater using a combustion ion chromatography system

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

Determination of Hexavalent Chromium in Drinking Water Using Ion Chromatography

columns IonPac SCS 1 Silica Cation Separator

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Overcoming Challenging Matrices in Ion Chromatography

Determination of Inorganic Cations and Ammonium in Environmental Waters by Ion Chromatography Using the IonPac CS16 Column

Determination of trace anions in concentrated glycolic acid

ProPac WCX-10 Columns

Determination of Perchlorate in High Ionic Strength Fertilizer Extracts by Ion Chromatography

Direct Determination of Cyanate in a Urea Solution and a Urea-Containing Protein Buffer

for IonPac AG11-HC IonPac AS11-HC

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

Determination of Perchlorate in High Ionic Strength Fertilizer Extracts By Ion Chromatography

Waters. Ion Chromatography

Determination of formic and acetic acids in petroleum products by ion chromatography

Determination of Monochloroacetic Acid in Carbocisteine

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

Determination of Trace Anions in Concentrated Hydrofluoric Acid

Suppression in anion chromatography. More sensitive analysis of anions and organic acids

Sample Preparation for Ion Chromatography

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Determination of Inorganic Anions in Wastewater by Ion Chromatography

Determination of Trace Anions in Concentrated Glycolic Acid

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Determination of Anions and Cations on Multi (2) - Ion Chromatography System

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Determination of Common Inorganic Anions in Environmental Waters Using a Hydroxide Selective Column

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

Transcription:

TECHNICAL NOTE 122 Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC Authors Terri Christison and Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA Keywords Petrochemical, Dionex IonPac AS11-HC-4µm, HPIC, heat stable salts, amine wastewater, methyldiethanolamine, MDEA, Dionex ICS-5000 +, HPIC Goal Demonstrate high efficiency separations of heat stable salts in amine solutions using 4 µm anionexchange separation columns on a high pressure ion chromatography system. Introductory Crude natural gas (methane) must be chemically processed to remove impurities before the gas can be sold as a pure product. Some natural gas wells may contain high concentrations of carbon dioxide (CO 2 ) and hydrogen sulfide (H 2 S), the later known as sour gas because of the mercaptan odor. 1,2 The high sulfide content and acidity from dissolved carbon dioxide causes corrosion of metal pipes and acid rain, making sour gas undesirable as a commercial product. Therefore, sour gas is typically treated with amine (amine rich) solutions (e.g., ethanolamine, methanolamine, and methyldiethanolamine) to absorb hydrogen sulfide and carbon dioxide. 1,2 The resulting pure natural gas, defined as containing < 5.7 mg/m 3 hydrogen sulfide, is called sweet gas by the industry. 1 The amine processing solutions (amine lean) are stripped and regenerated to remove the sulfur compounds as elemental sulfur. However, the amine solutions also extract other contaminants which form salts of organic acids and sulfur species, such as oxalic acid, propanoic acid, formic acid, acetic acid, thiosulfate, and thiocyanate. 2 These respective anions are collectively termed heat stable amine salts because the salts are not removed by the amine stripping process. Furthermore, the high salt content in the amine solution increases the solution viscosity, reduces acid-absorbing capacity and increases corrosion-induced maintenance costs. These amine waste solutions must also be characterized to comply with discharge permits.

The latest advancement in ion chromatography (IC) instrumentation, the high-pressure Thermo Scientific Dionex ICS-5000 + HPIC system, can operate continuously at 5000 psi for both analytical and capillary scale formats. The Dionex ICS-5000 + HPIC system can therefore exploit the high-efficiency separations offered by smaller particle size separation columns. When combined with the advantages and ease-of-use of a Reagent-Free IC (RFIC ) system, this system permits excellent enhanced resolution of closely eluting peaks with excellent reproducibility, thereby yielding greater quantification accuracy and consistently reliable results. In this study, we determined the anions in mixtures of both common inorganic anions and heat stable amine salts (fluoride, chloride, nitrate, nitrite, bromide, sulfate, phosphate, acetate, formate, propionate, sulfite, thiosulfate, thiocyanate) added to methyldiethanolamine solutions. The anions were separated by anionexchange chromatography using a Thermo Scientific Dionex IonPac AS11-HC-4µm (2 250 mm) highefficiency guard column and detected using suppressed conductivity. This column is optimized for high-efficiency separations of organic acids and is well suited for this application. Table 1. Consumables list. Product Name Type Dionex Part Number Dionex EGC 500 KOH Anion Eluent Generator cartridge* 075778 Dionex CR-ATC 500 Anion electrolytic trap column* 075550 Dionex IonPac AG11-HC-4µm Anion guard column* 078036 Dionex IonPac AS11-HC-4µm Anion separation column* 078035 Dionex ASRS 300 Anion suppressor 064555 Dionex HP Degas Module Degas module* 075522 Dionex HP fittings (blue) * high pressure Equipment Dionex ICS-5000 + HPIC system SP/DP Pump module Bolts / Ferrules* EG Eluent Generator module with high pressure degas module DC Detector/Chromatography module Dionex AS-AP Autosampler 074449 / 074373 Thermo Scientific Dionex Chromeleon Chromatography Data System (CDS) software ver. 6.8 or 7.1. Dionex AS-AP Autosampler Fresh 18 M Ω-cm Deionized Water Eluent In Dionex ICS-5000 + Reagent-Free HPIC System Regen SRS 300* suppressor CD Syringe Needle Columns* Tray carousel Heat Exchange Tubing Regen Fresh 18 M Ω-cm Deionized Water Sample Loop Degas Module* CR-TC 500 * EGC 500* Pump* Waste Vent * High-pressure device Waste Figure 1. Flow diagram for the high-pressure, Reagent-Free Dionex ICS-5000 + HPIC system. 2

Reagents and standards 18 MΩ-cm degassed deionized water ACS Grade reagents, Fisher Scientific Samples Synthetic mixtures of heat stable salts added to deionized water, and 10, 20, 30, 50 wt% MDEA Conditions Columns: Dionex IonPac AG11-HC-4µm (2 50 mm) AS11-HC-4µm (2 250 mm) Eluent source: Thermo Scientific Dionex EGC 500 KOH Eluent Generator Cartridge Thermo Scientific Dionex CR-ATC 500 Continuously Regenerated Cation Trap Column Gradient: 1 mm from -10 to 8 min, 1 30 mm from 8 to 28 min, 30 72 mm from 28 to 38 min, (72 100 mm from 38 to 60 min for elution of thiocyanate) Flow rate: 0.38 ml/min Column temp.: 30 C Inj. volume: 5 µl Detection: Suppressed conductivity, Thermo Scientific Dionex ASRS 300 Anion Self-Regenerating Suppressor, recycle mode, 68 ma Background conductance: 0.2 0.5 µs Noise: 2 3 ns System backpressure: 3200 3600 psi Tip: It is important to use 18 MΩ-cm resistivity, deionized water for standards, eluent, and autosampler flush solution. It is recommended to degas the deionized water intended for eluent in anion determinations. (An appropriate degassing method is vacuum filtration.) Using deionized water with resistivity less than 18 MΩ-cm can reduce sensitivity, introduce contamination, and affect calibration, thereby resulting in inaccurate quantification. Results can vary and contamination introduced from samples can affect the chromatography Instrument Setup and Installation Tip: To achieve the best chromatography with high pressure IC, it is important to use high pressure connectors and ferrules (see Table 1) for all connections prior to the suppressor. The high pressure Dionex ICS-5000 + HPIC Reagent-Free system is designed to operate up to 5000 psi. To setup this application, plumb the consumables and modules of the Dionex ICS-5000 + HPIC system, according to Figure 1. Install and hydrate the Dionex EGC 500 KOH cartridge, Dionex CR-ATC 500, and 2 mm Dionex ASRS 300 suppressor according to the product manual instructions. Complete the installation according to flow diagram. Use high-pressure connectors and ferrules (blue) for all of the fittings from the pump to prior to the suppressor. Standard pressure fittings can be used for the suppressor and detector connections. Detailed instructions are described in Technical Note (TN) 129, the product manuals, and the instrument installation and operator s manuals. 3 6 Standard and Sample Preparation Prepare individual stock solutions and a combined spiking solution of propionate, acetate, bromide, formate, chloride, nitrate, nitrite, sulfate, oxalate, carbonate, thiocyanate, thiosulfate, and sulfite by mixing the appropriate amounts with DI water to achieve the concentrations in Figure 2. Prepare 10, 20, 30, 40, and 50 wt% MDEA solutions spiked with the above anions in deionized water. The standards containing sulfite must be prepared daily. Calibration standards were prepared by diluting the stock standards appropriately. Results and Discussion Determinations of heat stable amine salts is needed to monitor the efficiency of the amine processing of the sour natural gas. To resolve these peaks, a high-capacity, high-efficiency Dionex AS11-HC-4µm anion-exchange column is used. 3

Column: Dionex IonPac AG11-HC-4µm, AS11-HC-4µm, 2 250 mm Eluent Source: Dionex, EGC 500 KOH Gradient: Potassium hydroxide 1 mm from -10 to 8 min, 1 30 mm from 8 to 28 min 3 72 mm from 28 to 38 min Flow Rate: 0.38 ml/min Inj. Volume: 5 µl Column Temp.: 30 C Detection: Suppressed conductivity Dionex ASRS 300, 2 mm, recycle mode Samples: Heat stable salts in A: Water; B: 10% MDEA*; C: 30% MDEA* IC System: High-pressure Dionex ICS-5000 + HPIC Peaks: 1. Fluoride 2 mg/l 8. Nitrate 100 2. Acetate 10 9. Carbonate 50 3. Propionate 10 10. Sulfite 100 4. Formate 10 11. Sulfate 100 5. Chloride 100 12. Oxalate 20 6. Nitrite 10 13. Phosphate 20 7. Bromide 10 14. Thiosulfate 10 * Methyldiethanolamine Column: Dionex IonPac AG11-HC-4µm, AS11-HC-4µm, 2 250 mm Eluent Source: Dionex, EGC 500 KOH Gradient: Potassium hydroxide 1 mm from -10 to 8 min, 1 30 mm from 8 to 28 min 3 72 mm from 28 to 38 min Flow Rate: 0.38 ml/min Inj. Volume: 5 µl Column Temp.: 30 C Detection: Suppressed conductivity Dionex ASRS 300, 2 mm, recycle mode Samples: Heat stable salts in 30% MDEA* IC System: High-pressure Dionex ICS-5000 + HPIC Peaks: 1. Fluoride 2 mg/l 8. Nitrate 100 2. Acetate 10 9. Carbonate 50 3. Propionate 10 10. Sulfite 100 4. Formate 10 11. Sulfate 100 5. Chloride 100 12. Oxalate 20 6. Nitrite 10 13. Phosphate 20 7. Bromide 10 14. Thiosulfate 10 15. Thiocyanate 10 * Methyldiethanolamine 25 5 10 11 25 5 11 3620 psi 14 3620 psi 10 µs -2 0 C B A 2 4 1 3 6 8 7 9 12 10 20 30 Minutes Figure 2. Separations of heat stable salts in MDEA using a shallow gradient and high-pressure IC. 13 38 µs -2 0 2 4 1 3 6 7 8 9 12 13 10 20 30 Minutes Figure 3. Separation of heat stable salts in 30% MDEA using a shallow gradient and high-pressure IC. 14 40 15 51 Figure 2 compares the separations of the 14 heat stable amine salts in deionized water, 10% and 30% MDEA with excellent recoveries from 95 to 100% as compared to the deionized water. Recoveries are reduced to ~80% when spiked into the 50% MDEA (not shown here). All peaks elute within 35 min from the column with large separations between peaks 4 and 5 and between peaks 12 and 13. Figure 3 shows the separation of thiocyanate and 14 anions spiked into 30% MDEA solution. The gradient was increased at 38 min to elute thiocyanate from the column within 50 min. A step change could also be used to reduce the run time. The peaks in both chromatograms show very high efficiency which is characteristic of this 4 µm particle size column. The system pressure is 3620 psi which is only possible with RFIC technology when using a high-pressure IC system, such as the Dionex ICS-5000 + HPIC system. 4

Conclusion This technical note demonstrates the high-resolution, high-efficiency separations possible using a Dionex IonPac AS11-HC-4µm and a high-pressure Reagent-Free IC system, such as the Dionex ICS-5000 + HPIC system. The Dionex ICS-5000 + HPIC system permits continuous operations up to 5000 psi to deliver high-resolution separations across all column formats including standard bore, microbore, and capillary scale. Additional information on inorganic anion determinations in environmental and industrial wastewater samples using standard bore and microbore IC are reviewed in application update AU 138, and application notes AN 135 and AN 138. 7 9 References 1. Natural Gas.org, http://www.naturalgas.org/naturalgas/ processing_ng.asp#sulphur, accessed Dec. 10, 2012. 2. Rooney, P.C.; Bacon, T.R.; DuPart, M.S. Effect of Heat Stable Salts on MDEA Corrosivity, Parts 1 and 2. Hydrocarbon Processing, 1996, Mar, 95 103; 1997, Apr, 65 71. 3. Christison, T.; Bahten, K.; Briggs, J.; Lopez, L. Technical Note 129: Configuring High-Pressure IC Systems for Analytical Flow Rates, TN70317_E, Sunnyvale, CA, 2012. 4. Thermo Fisher Scientific. Dionex Anion Self- Regenerating Suppressor 300 and Cation Self- Regenerating Suppressor 300 Product Manual. Dionex Doc No. 031956-06, Sunnyvale, CA, 2009. 5. Thermo Fisher Scientific. Dionex ICS-5000 + Ion Chromatography System Installation instructions. Dionex Doc No. 065447-01, Sunnyvale, CA, 2012. 6. Thermo Fisher Scientific. Dionex AS-AP Autosampler Operator s Manual. Dionex Doc No. 065361-07, Sunnyvale, CA, 2012. 7. Thermo Fisher Scientific. Application Update 138, Determination of Ethanolamines in Industrial Waters by Cation-Exchange Chromaotgraphy, Dionex LPN 0995, Sunnyvale, CA, 1998. 8. Thermo Fisher Scientific. Application Note 135: Determination of Inorganic Anions in Wastewater by Ion Chromatography, Dionex LPN 1226, Sunnyvale, CA, 2000. 9. Thermo Fisher Scientific. Application Note 138: Determination of Thiosulfate in Refinery and Other Wastewaters, Dionex LPN 1237, Sunnyvale, CA, 2001. Find out more at www.thermofisher.com/ic 2017 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representatives for details. TN70192-EN 1017S