Stability Indicating RP-HPLC Method for Determination of Valsartan in Pure and Pharmaceutical Formulation

Similar documents
International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 9(1), 35-42

Impact factor: 3.958/ICV: 4.10 ISSN:

RP-HPLC Estimation of Trospium Chloride in Tablet Dosage Forms

Simultaneous HPLC Determination of Methocarbamol, Paracetamol and Diclofenac Sodium

Reverse Phase High Performance Liquid Chromatography method for determination of Lercanidipine hydrochloride in bulk and tablet dosage form

Development and Validation of Stability Indicating RP-HPLC Method for the Determination of Anagrelide HCl in Pharmaceutical Formulation

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

J Pharm Sci Bioscientific Res (4): ISSN NO

Validated RP-HPLC Method for Estimation of Cefprozil in Tablet Dosage Form

A Simple, Novel Validated Stability Indicating RP-HPLC method for estimation of Duloxetine HCl in Capsule Pharmaceutical Formulation

RP-HPLC Method for the Estimation of Nebivolol in Tablet Dosage Form

RP-HPLC Method Development and Validation of Dapagliflozin in Bulk and Tablet formulation

Development and Validation of Stability Indicating Assay Method of Etodolac by using UV-Visible Spectrophotometer

Development and Statistical Validation of Spectrophotometric Methods for the Estimation of Nabumetone in Tablet Dosage Form

Novus International Journal of Analytical Innovations 2012, Vol. 1, No. 3

STABILITY INDICATING RP HPLC METHOD FOR ANALYSIS OF DORZOLAMIDE HCl IN THE BULK DRUG AND IT S PHARMACEUTICAL DOSAGE FORM

Department of Quality Assurance, Luqman College of Pharmacy, GULBARGA (K.S.) INDIA ABSTRACT

Development and validation a RP-HPLC method: Application for the quantitative determination of quetiapine fumarate from marketed bulk tablets

Development and Validation of a HPLC Method for Determination of Anastrozole in Tablet Dosage Form

Stability-indicating HPLC determination of tolterodine tartrate in pharmaceutical dosage form

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD TO DETERMINE CINITAPRIDE HYDROGEN TARTARATE IN BULK AND PHARMACEUTICAL FORMULATION

Stability indicating RP-HPLC method for determination of azilsartan medoxomil in bulk and its dosage form

Validated First Order Derivative Spectroscopic Method for the determination of Stavudine in Bulk and Pharmaceutical Dosage Forms

Spectrophotometric Determination of Lorsartan Potassium and its Dosage Form by Bromothymol Blue and Phosphate Buffer

Received: ; Accepted:

International Journal of Pharma and Bio Sciences V1(1)2010. HPLC method for analysis of Lercanidipine Hydrochloride in Tablets

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

CHAPTER 19 PARACETAMOL + IBUPROFEN

Analytical Method Development and Validation of Lafutidine in Tablet dosage form by RP-HPLC

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

Development And Validation Of Rp-Hplc Method For Determination Of Velpatasvir In Bulk

UV Spectrophotometric Estimation of Levoceterizine Dihydrochloride in Bulk and Dosage Form

Development of Validated Analytical Method of Mefenamic Acid in an Emulgel (Topical Formulation)

Validated spectrophotometric determination of Fenofibrate in formulation

International Journal of Pharma Research and Health Sciences. Available online at

Journal of Pharmaceutical and Biomedical Analysis Letters. Analysis Letters

Int. J. Pharm. Sci. Rev. Res., 30(2), January February 2015; Article No. 09, Pages: 63-68

Chapter-4 EXPERIMENTAL WORK BY RP-HPLC

Impact factor: 3.958/ICV: 4.10 ISSN:

Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article. Estimation of zaleplon by a new RP-HPLC method

SIMULTANEOUS RP HPLC DETERMINATION OF CAMYLOFIN DIHYDROCHLORIDE AND PARACETAMOL IN PHARMACEUTICAL PREPARATIONS.

New Simple UV Spectrophotometric Method for Determination of Mirtazapine in Bulk and pharmaceutical dosage forms

International Journal of Current Trends in Pharmaceutical Research. International Journal of Current Trends in Pharmaceutical Research

Research Article. Figure 1. Chemical structure of doxofylline. Indonesian J. Pharm. Vol. 24 No. 1 : ISSN-p :

Development and Validation of Stability-Indicating RP-HPLC Method for Estimation of Atovaquone

Zero And First Order Derivative Spectrophotometric Methods For Determination Of Dronedarone In Pharmaceutical Formulation

Validation of Stability-Indicating RP-HPLC Method for the Assay of Ibrutinib in Pharmaceutical Dosage form

Simultaneous estimation of ramipril and valsartan by RP-HPLC method in combined. dosage form

Chapter 4: Verification of compendial methods

Received: ; Accepted:

Pharmacophore 2011, Vol. 2 (4), ISSN Pharmacophore. (An International Research Journal)

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

International Journal of PharmTech Research CODEN (USA): IJPRIF, ISSN: , ISSN(Online): Vol.9, No.7, pp , 2016

International Journal of Pharmaceutical Research & Analysis

STABILITY INDICATING RP-HPLC METHOD FOR DETERMINATION OF EPROSARTAN IN PURE AND PHARMACEUTICAL FORMULATION

Stability Indicating RP-HPLC Method for Determination and Validation of Repaglinide in Pharmaceutical Dosage Form

STABILITY INDICATING METHOD OF RELATED IMPURITIES IN VENLAFAXINE HYDROCHLORIDE SUSTAINED RELEASE TABLETS

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

Research Article METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF ELBASVIR AND GRAZOPREVIR BY RP-HPLC

INTERNATIONAL JOURNAL OF UNIVERSAL PHARMACY AND BIO SCIENCES

CHAPTER - IV. Acharya Nagarjuna University, Guntur 105

Volume 6, Issue 2, January February 2011; Article-015

RP-HPLC Method for Simultaneous Estimation of Atenolol, Hydrochlorothiazide and Losarton in Tablet Dosage form

Development and validation of RP-HPLC method for determination of marker in polyherbal marketed Kankasava formulations

Development and Validation of UV Spectrophotometric Estimation of Diclofenac Sodium Bulk and Tablet Dosage form using Area under Curve Method

UV Spectrophotometric Method for the Estimation of Itopride Hydrochloride in Pharmaceutical Formulation

RP-HPLC Method for the Determination of Cinitapride in the Presence of its Degradation Products in Bulk Drug

Method Development and Validation for the Estimation of Darunavir in Rat Plasma by RP-HPLC

Low-level Determination of 4-Hydrazino Benzoic Acid in Drug Substance by High Performance Liquid Chromatography/Mass Spectrometry

Research Article Available online at

DEVELOPMENT AND VALIDATION OF NEW RP-HPLC METHOD FOR THE DETERMINATION OF AFLOQUALONE IN HUMAN PLASMA AND FORMULATION

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

SIMPLE AND SENSITIVE VALIDATED REVERSE PHASE HPLC-UV METHOD FOR THE DETERMINATION OF LYMECYCLINE IN PHARMACEUTICAL DOSAGE FORMS

Research Article. *Corresponding author S.Ushasri

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF GABAPENTIN IN PURE AND PHARMACEUTICAL FORMULATIONS

International Journal of Pharma and Bio Sciences V1(1)2010 UV- SPECTROPHOTOMETRIC DETERMINATION OF TENATOPRAZOLE FROM ITS BULK AND TABLETS

Pelagia Research Library

World Journal of Pharmaceutical and Life Sciences WJPLS

INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND LIFE SCIENCES

Development and validation of RP-LC method for lisinopril dihydrate in bulk and its pharmaceutical formulations

Method Development and Validation Of Prasugrel Tablets By RP- HPLC

Mashhour Ghanem 1 and Saleh Abu-Lafi 2 * ABSTRACT ARTICLE INFO

DEVELOPMENT AND VALIDATION OF A RP-HPLC METHOD FOR DETERMINATION OF LOPINAVIR IN BULK AND PHARMACEUTICAL DOSAGE FORM

Pravin Kumar et al. / SGVU Journal of Pharmaceutical Research & Education, 2017, 2(1), Research Article

Spectrophotometric estimation and validation of hydrochlorothiazide in tablet dosage forms by using different solvents

Spectroscopic Method For Estimation of Atorvastatin Calcium in Tablet Dosage Form

DEVELOPMENT OF AN RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION AND FORCE DEGRADATION OF CEFIXIME AND MOXIFLOXACIN IN BULK AND PHARMACEUTICAL DOSAGE FORM

Available online at Universal Research Publications. All rights reserved

Journal of Advanced Scientific Research DEVELOPMENT AND VALIDATION OF STABILITY-INDICATING RP-HPLC METHOD FOR ESTIMATION OF DABIGATRAN ETEXILATE

Available Online through

Method development and validation for the estimation of metronidazole in tablet dosage form by UV spectroscopy and derivative spectroscopy

International Journal of Pharma and Bio Sciences

Development and Validation of RP-HPLC Method for Quantitative estimation of Indapamide in Bulk and Pharmaceutical dosage forms

4.1 MATERIALS 4.2 EQUIPMENTS

UV Spectrophotometric Method for the Estimation of Tadalafil in Bulk and Tablet Dosage form

Development and Validation of Sensitive RP-HPLC Method for the Estimation of Glibenclamide in Pure and Tablet Dosage Forms

AND VALIDATION FOR SIMULTENEOUS ESTIMATION OF AMBROXOL HYDROCHLORIDE AND DOXOFYLLINE IN PHARMACEUTICAL DOSAGES FORMS AND BULK DRUGS BY RP-HPLC METHOD

ANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF IVABRADINE HCL IN BULK AND FORMULATION

WORLD JOURNAL OF PHARMACEUTICAL AND MEDICAL RESEARCH

Transcription:

ISSN: 0973-4945; CODEN ECJHAO E- Chemistry http://www.e-journals.net 2010, 7(1), 246-252 Stability Indicating RP-HPLC Method for Determination of Valsartan in Pure and Pharmaceutical Formulation S. K. PATRO *, S. K. KANUNGO, V. J. PATRO # and N. S. K. CHOUDHURY Department of Pharmaceutical Analysis & Quality Assurance, Institute of Pharmacy and Technology, Salipur, Cuttack, Orissa-754202, India. # College of Pharmaceutical Sciences, Mohuda, Berhampur, Ganjam, Orissa, India. Department of Pharmacy, S. C.B. Medical College, Cuttack, Orissa, India. skpatro69@gmail.com Received 8 July 2009; Accepted 5 September 2009 Abstract: A simple, rapid and accurate and stability indicating RP-HPLC method was developed for the determination of valsartan in pure and tablet forms. The method showed a linear response for concentrations in the range of 50-175 µg/ml using 0.01 M NH 4 H 2 PO 4 (ph 3.5) buffer: methanol [50:50] as the mobile phase with detection at 210 nm and a flow rate of 1 ml/min and retention time 11.041 min. The method was statistically validated for accuracy, precision, linearity, ruggedness, robustness, forced degradation, solution stability and selectivity. Quantitative and recovery studies of the dosage form were also carried out and analyzed; the % RSD from recovery studies was found to be less than 1. Due to simplicity, rapidity and accuracy of the method, we believe that the method will be useful for routine quality control analysis. Keywords: Valsartan, RP-HPLC, Degradation studies. Introduction Stability indicating methods have become an important aspect of any analytical method validation and a part of US FDA requirements 1. Chemically, valsartan is designated as N-(1-oxopentyl)-N-{[2 -(1H-tetrazol-5-yl)[1,1 -biphenyl]-4-yl]methyl}-l-valine 2. Valsartan is a new antihypertensive drug, which is non-peptide potent highly selective, orally active antagonist at the angiotensin II AT 1 -receptors 3-5. Very few methods appeared in the literature in the spectrophotometric determination of valsartan 6,7. Therefore, we have made an attempt to develop a new, simple, accurate stability indicating RP-HPLC method for the determination of valsartan in pure and tablet forms. The proposed method was validated as per ICH guidelines Q2A 8.

Stability Indicating RP-HPLC Method 247 Experimental All analytical works were performed on Shimadzu HPLC LC 2010 CHT series equipped with quaternary constant flow pump, auto injector, SPDM 10 A VP Shimadzu Photo Diode array detector, LC Solution Version 1.22 SP1 software, Phenomenex Gemini C18 column (4.6 mm 25 cm, 5 µm particle size) as stationary phase, a calibrated electronic single pan balance Sartorius CP 225 D, ph Meter of LABINDIA, Enertech Fast Clean Ultrasonic cleaner were also used during the analysis. Analytically pure valsartan has been obtained as a gift sample from M/s Torrent Pharmaceutical Ltd., (Ahmedabad, India). Tablet (Diovan R ) was purchased from the local market. All chemicals and reagents used were of AR/HPLC grade. Preparation of mobile phase and standard stock solution The mobile phase was prepared by mixing 500 ml of 0.01 M ammonium dihydrogen orthophosphate [NH 4 H 2 PO 4 ] (ph adjusted to 3.5 with formic acid) buffer with 500 ml of methanol. The mobile phase was sonicated 10 minutes and then it was filtered through a 0.45 µ membrane filter paper. An accurately weighed quantity of 25 mg was transferred to 100 ml volumetric flask, which was then dissolved and made up to volume with mobile phase to give 250 µg/ml. Optimised chromatographic conditions RP- HPLC analysis was performed by isocratic elution with flow rate of 1 ml/min. The mobile phase containing 0.01 M ammonium dihydrogen orthophosphate (ph adjusted to 3.5 with Formic acid) buffer and methanol in the ratio of 50:50 (v/v) to obtain well resolved peak of valsartan (R t = 11.041 min) as shown in Figure 1. Wavelength of maximum absorption was selected by Photo diode Array detector. The drug shows reasonably good response at 210 nm. mau Calibration curve for valsartan Min Figure 1. A typical chromatogram of standard valsartan. Appropriate aliquots of standard stock solution were taken in different 10 ml volumetric flasks and diluted up to the mark with mobile phase to obtain final concentrations of 50, 75, 100, 125, 150 and 175 µg/ml of valsartan respectively. The solutions were injected using a 20 µl fixed loop system and chromatograms were recorded. Calibration curve was drawn by plotting average peak area versus concentrations as shown in the Figure 2. The linearity table of valsartan is shown in Table 1.

248 S.K. PATRO et al. Area Concentration, µg/ml Figure 2. Calibration curve of valsartan. Table 1. Linearity of valsartan. Concentration, µg/ml Area 50 4198917 75 6239634 100 8337972 125 10336689 150 12302522 175 14268455 Analysis of the marketed formulations Twenty tablets were weighed accurately and crushed to form fine powder. Accurately weighed quantity of powder equivalent to 80 mg of valsartan was dissolved in 100 ml of volumetric flask with the mobile phase. The flask was sonicated for 20 min and then the solution was filtered using Whatmann filter paper No. 1. Appropriate volumes of the aliquot were transferred into five different 20 ml volumetric flasks and the volume was made up to the mark with mobile phase to obtain 100 µg/ml of valsartan. The solution was sonicated for 10 min and injected under above chromatographic conditions and peak areas were measured. The results are shown in the Table 2. Table 2. Analysis of commercial Tablet (Diovan R ) (*n=5). Analyte Label claim mg/tablet Amount Found mg/tablet C.I. %RSD t Valsartan 80 79.8625 99.8281±1.1302 0.7114 0.4840 * Mean of 5 determinations Validation of the method The developed method was validated in terms of linearity, accuracy, specificity, limit of detection and limit of quantitation, intra-day and inter-day precision and repeatability of measurement. Linearity The linearity range was found 50-175 µg/ml. The regression equation for valsartan was found to be Y = 81,549.4425 x + 91,187.9057 and correlation coefficient (r 2 = 0.9998).

Stability Indicating RP-HPLC Method 249 Precision Intra-day and inter-day precision of the assay samples containing valsartan (75,100,125,150 µg/ml) were analyzed five times in the same day (intraday) and for three consecutive days by different analysts. Precision was calculated as intra and inter-day coefficient of variation [% C.V. = (S. D. /mean) x 100] as shown in the Table 3. Table 3. Precision data of the proposed method (*n=5). Analyte Valsartan Accuracy Intraday measurement Inter-day measurement Conc. Conc. Area %C.V. µg/ml µg/ml Area % C.V. 75 6244337.09 0.081 75 6225047.16 0.213 100 8334707.85 0.064 100 8313498.93 0.317 125 10340506.14 0.062 125 10331080.65 0.137 150 12289328.99 0.090 150 12266412.46 0.317 * Mean of 5 determinations It was found out by recovery study using standard addition method. Known amounts of standard valsartan was added to pre-analyzed samples at a level from 50% up to 100% and then subjected to the proposed HPLC method 9. Results of recovery studies are shown in Table 4. Table 4. Recovery studies of valsartan. Analyte Formulation µg/ml Valsartan Amount of Standard drug added, µg/ml Amount recovered, µg/ml C.I. %RS D 75 37.5 37.485 99.96±1.089 0.685 0.342 0.116 75 56.25 56.045 99.63±0.624 0.393 0.196 1.858 75 75 75.0275 100.03±0.550 0.345 0.172 0.212 SD: Standard deviation, SE: standard error, C.I.: Confidence Interval within which true value may be found at 95% confidence level = R ± ts/ n, R: Mean percent result of analysis of Recovery study (n = 4). Theoretical t values at 95% confidence level for n - 1 degrees of freedom t (0.05, 3) = 3.182. Robustness By introducing small but deliberate changes in the mobile phase ph (± 0.1), mobile phase composition (±2%), detection wavelength (±5.0 nm), flow rate (±10.0 % of absolute value) robustness of the described method were studied. The robustness of the method was assessed for 3 different amounts of the calibration plot (75, 100, 125 µg/ml). Sensitivity The sensitivity of the method was determined with respect to LOD and LOQ. The LOD and LOQ were separately determined based on the standard calibration curve. LOD = (3.3 x S.D /S and LOQ = 10 x S.D/S, where, S.D is the standard deviation of the y- intercepts of regression line and S is the average slope of the calibration curve. Forced degradation studies Forced degradation studies were performed to evaluate the stability indicating properties and specificity of the method. Intentional degradation was carried out by exposing the 20 mg SE t

250 S.K. PATRO et al. of samples in three different 20 ml volumetric flasks containing acid (0.1 N HCl, at 40 0 C), basic (0.1 N NaOH, at 40 0 C) and hydrogen peroxide (3% H 2 O 2 ) and kept for 2 hours. Then aliquot 2 ml was transferred into another three 20 ml volumetric flasks and made up to the mark with mobile phase in order to get 0.1 mg/ml. All these three volumetric flasks were kept in the darkness to exclude the possible degradation effect of light. 20 µl of sample solutions were injected and analyzed against control samples (lacking of degradation treatment). The results of forced degradation studies are shown in Table 5. Table 5. Forced degradation study of valsartan. Agent Exposure time, h Condition Assay % 0.1 N HCl * 2 Heat 93.55 0.1 N NaOH * 2 Heat 101.402 3 % H 2 O 2 2 Normal 92.42 *Heat at 40 0 C mau Min Figure 3. Acid degradation of valsartan. mau Min Figure 4. Basic degradation of valsartan.

Stability Indicating RP-HPLC Method 251 mau Min Figure 5. Oxidative degradation of valsartan. Results and Discussion A mobile phase consisting of buffer (ph 3.5) and methanol in the ratios of 50:50 gave a well resolved, sharp peak for valsartan with a retention time of 11.041 min. The flow rate was 1 ml/min and effluent was monitored at 210 nm and a Phenomenex Gemni C18 column and 25 o C temperatures for the HPLC system and were found to be the best for the analysis. System suitability was performed by injecting five replicate injections of working standard solution (100 µg/ml). The system suitability results are shown in Table 6. Table 6. System suitability. Parameter Results Retention time, min 11.041 Theoretical plate 3273.605 Capacity factor 1102.75 Asymetric factor 1.405 Repeatability 0.071 (% RSD ) The results of specificity studies indicated no interference from excipients, impurities and degraded products due to various stress conditions and assured that the peak response was due to a single component only. The chromatogram of samples degraded with acid, base and hydrogen peroxide showed one small peak having retention time 5.398, 5.424 and 5.392 mins and well resolved from the drug peak, the chromatograms are shown in Figures 3, 4 and 5. The % RSD was less than 1 in intraday, inter-day precision and in each parameter of robustness. So the proposed method is more precise and robust. The lower limit of Detection and the limit of quantitation were found to be 0.0388 and 0.1176 µg/ml respectively. Conclusion The modalities adopted in experimentation were successfully validated as per analytical procedures laid down in routine. The proposed method was validated by preliminary analysis of standard sample and by recovery studies. The percentage of average recoveries was obtained in the range of 98.89 to 100.587. The results of analysis of average recoveries obtained in each instance were compared with the theoretical value of 100 percent by means

252 S.K. PATRO et al. of Student s t test. As the calculated t values are less than theoretical values (Table 4), it is concluded that the results of recoveries obtained in agreement with 100 percent for each analyte are accurate. The absence of additional peaks in the chromatogram indicates noninterference of the common excipients used in the tablets. This demonstrates that the developed HPLC method is new, simple, linear, accurate, sensitive and reproducible, and stability indicating assay. Thus, the developed method can be easily used for the routine quality control of bulk and tablet form. Acknowledgement The authors are thankful to the Director of Startech Pvt Ltd, Hyderabad for providing the necessary facilities to carry out this work. References 1. Rockville M D, United States Pharmacopoeia; 25 th Edn., United States Pharmacopoeial Convention Inc, 2002, 2150. 2. Budavri S, The Merck Index; 12 th Edn; Merk & Co, Inc., Whitehouse Station, NJ, 1996, 1691. 3. Crisscione L, Gasparo M D, Buhlamayer P, Whitebread S, Ramjoune and Wood J Br J Pharmacol., 1993, 110, 761-771. 4. Criscione L, Bradlely W A, Buhlmayer P, Whitebread S, Glazer R P, Lloyd P, Mueller M and Gasparo M D, Drug Rev., 1995, 13, 230-250. 5. Thurmann P V, Expert Opin Pharmacother., 2000, 1, 337-350. 6. Satana E, Altinay S, Goeger S A and Ozkan Z Sanmurk, J Pharm Biomed Anal., 2001, 25, 1009-1013. 7. Tatar S and Saglik S, J Pharm Biomed Anal., 2002, 30, 371-375. 8. Carstensen J T and Rhodes C T, Drug Stability; 2 nd Edn., Marcel Dekker, New York, 2008, 358. 9. Snyder L R, Kirkland J J and Glajch J L, Practical HPLC method development, 2 nd Edn., Wiley-interscience Publication, John Wiley & Sons, Inc, 1997, 709.

International Medicinal Chemistry Photoenergy International Organic Chemistry International International Analytical Chemistry Advances in Physical Chemistry International Carbohydrate Chemistry Quantum Chemistry Submit your manuscripts at The Scientific World Journal International Inorganic Chemistry Theoretical Chemistry Catalysts International Electrochemistry Chromatography Research International Spectroscopy Analytical Methods in Chemistry Applied Chemistry Bioinorganic Chemistry and Applications International Chemistry Spectroscopy