The Use of Self-Induced XRF to Quantify the Pu Content in PWR Spent Nuclear Fuel

Similar documents
Quartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays

SPENT NUCLEAR FUEL SELF-INDUCED XRF TO PREDICT PU TO U CONTENT. A Thesis ALISSA SARAH STAFFORD

Characterization of a Portable Neutron Coincidence Counter Angela Thornton and W. Charlton Texas A&M University College Station, TX

FLAT QUARTZ-CRYSTAL X-RAY SPECTROMETER FOR NUCLEAR FORENSICS APPLICATIONS. A Thesis ALISON VICTORIA GOODSELL

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

A New MCNPX PTRAC Coincidence Capture File Capability: A Tool for Neutron Detector Design


WM2010 Conference, March 7-11, 2010, Phoenix, AZ

ITU-Nuclear Safeguards and Security Unit

Computational study of Passive Neutron Albedo Reactivity (PNAR) measurement with fission chambers

TECHNICAL WORKING GROUP ITWG GUIDELINE ON LABORATORY APPLICATIONS OF HIGH-RESOLUTION GAMMA SPECTROMETRY

Evaluation of Nondestructive Assay Characterization Methods for Pipe- Over-Pack Containers

2017 Water Reactor Fuel Performance Meeting September 10 (Sun) ~ 14 (Thu), 2017 Ramada Plaza Jeju Jeju Island, Korea

Uppsala University. Access to the published version may require subscription.

Uncertainty Quantification for Safeguards Measurements

Detection efficiency of a BEGe detector using the Monte Carlo method and a comparison to other calibration methods. Abstract

Introduction. WM2011 Conference, February 27 March 3, 2011, Phoenix, AZ

Nondestructive Fission Gas Measurements by Means of Gamma Spectroscopy and Gamma Tomography. Scott Holcombe

Emerging Capabilities for Advanced Nuclear Safeguards Measurement Solutions

High Precision Nondestructive Assay to Complement DA. H.O. Menlove, M.T. Swinhoe, and J.B. Marlow Los Alamos National Laboratory

Digital simulation of neutron and gamma measurement devices

RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA

Comparison of Several Detector Technologies for Measurement of Special Nuclear Materials i

Gamma Emission Tomography for Determining Pin-wise Percent Fission Gas Release in Fuel Assemblies at the Halden Boiling Water Reactor

Seaborg s Plutonium?

U and Pu Gamma-Ray Measurements of Spent Fuel Using a Gamma-Ray Mirror Band-Pass Filter

IAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES

ASSESSMENT OF THE FINGERPRINTING METHOD FOR SPENT FUEL VERIFICATION IN MACSTOR KN-400 CANDU DRY STORAGE. A Thesis NANDAN GOWTHAHALLI CHANDREGOWDA

VALIDATION OF IQ3 MEASUREMENTS FOR HIGH-DENSITY LOW-ENRICHED-URANIUM WASTE DRUMS AT PELINDABA

WM2012 Conference, February 26 March 1, 2012, Phoenix, Arizona, USA. Segmented Gamma Scanner for Small Containers of Uranium Processing Waste

Melissa A. Schear H. O. Menlove L. G. Evans S. J. Tobin S. C. Croft

Gamma-ray measurements of spent PWR fuel and determination of residual power

AUTOMATIC GAMMA-SCANNING SYSTEM FOR MEASUREMENT OF RESIDUAL HEAT IN SPENT NUCLEAR FUEL

(1) SCK CEN, Boeretang 200, B-2400 Mol, Belgium (2) Belgonucléaire, Av. Arianelaan 4, B-1200 Brussels, Belgium

MEASUREMENTS OF DECAY HEAT AND GAMMA-RAY INTENSITY OF SPENT LWR FUEL ASSEMBLIES XA

EVALUATION OF PWR AND BWR CALCULATIONAL BENCHMARKS FROM NUREG/CR-6115 USING THE TRANSFX NUCLEAR ANALYSIS SOFTWARE

Nuclear Data Uncertainty Quantification for Applications in Energy, Security, and Isotope Production

An Improved U-Pu System for Field Pu Measurements

1 Introduction. 2 Method. Robert Metzger 1,*, Kenneth Van Riper 2, and George Lasche 3

2017 Water Reactor Fuel Performance Meeting September 10 (Sun) ~ 14 (Thu), 2017 Ramada Plaza Jeju Jeju Island, Korea

Parametric Study of Control Rod Exposure for PWR Burnup Credit Criticality Safety Analyses

Neutron Dose near Spent Nuclear Fuel and HAW after the 2007 ICRP Recommendations

NDT as a tool, for Post-Irradiation Examination.

Inaccuracy Determination in Mathematical Model of Labsocs Efficiency Calibration Program

Library of uranium and plutonium reference spectra Introduction

Three-dimensional RAMA Fluence Methodology Benchmarking. TransWare Enterprises Inc., 5450 Thornwood Dr., Suite M, San Jose, CA

Effect of Co-60 Single Escape Peak on Detection of Cs-137 in Analysis of Radionuclide from Research Reactor. Abstract

MOx Benchmark Calculations by Deterministic and Monte Carlo Codes

Comparison of PWR burnup calculations with SCALE 5.0/TRITON other burnup codes and experimental results. Abstract

Neutron and Gamma Ray Imaging for Nuclear Materials Identification

DEVELOPMENT OF A REAL-TIME DETECTION STRATEGY FOR MATERIAL ACCOUNTANCY AND PROCESS MONITORING DURING

G. Jossens a, C. Deyglun a, P. Gironès b, C. Mathonat a *, and A.Godot a

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

An introduction to Neutron Resonance Densitometry (Short Summary)

Fundamentals of Nuclear Power. Original slides provided by Dr. Daniel Holland

M.Cagnazzo Atominstitut, Vienna University of Technology Stadionallee 2, 1020 Wien, Austria

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software

The Use of Curium Neutrons to Verify Plutonium in Spent Fuel and Reprocessing Waste

SUB-CHAPTER D.1. SUMMARY DESCRIPTION

A Germanium Detector with Optimized Compton Veto for High Sensitivity at Low Energy

Application of Spectral Summing to Indeterminate Suspect Low-Level Drums at Los Alamos National Laboratory

Estimation of Control Rods Worth for WWR-S Research Reactor Using WIMS-D4 and CITATION Codes

ACTIVATION ANALYSIS OF DECOMISSIONING OPERATIONS FOR RESEARCH REACTORS

The Effect of Burnup on Reactivity for VVER-1000 with MOXGD and UGD Fuel Assemblies Using MCNPX Code

SMOPY a new NDA tool for safeguards of LEU and MOX spent fuel

Neutron Multiplicity Counting for Future Verification Missions: Bias When the Sample Configuration Remains Unknown

Characterization of radioactive waste and packages

Determining Plutonium Mass in Spent Fuel with Non-destructive Assay Techniques NGSI Research Overview and Update on NDA Techniques, Part I

arxiv:nucl-ex/ v2 21 Jul 2005

English text only NUCLEAR ENERGY AGENCY NUCLEAR SCIENCE COMMITTEE

PRACTICAL GAMMA SPECTROSCOPY ASSAY TECHNIQUES FOR LARGE VOLUME LOW-LEVEL WASTE BOXES

The outermost container into which vitrified high level waste or spent fuel rods are to be placed. Made of stainless steel or inert alloy.

NEUTRON PHYSICAL ANALYSIS OF SIX ENERGETIC FAST REACTORS

MA/LLFP Transmutation Experiment Options in the Future Monju Core

DESIGN AND OPERATION OF THE COMBINED TECHNOLOGY AUTOMATED WASTE CHARACTERISATION SYSTEM

SIMPLIFIED BENCHMARK SPECIFICATION BASED ON #2670 ISTC VVER PIE. Ludmila Markova Frantisek Havluj NRI Rez, Czech Republic ABSTRACT

Development of depletion models for radionuclide inventory, decay heat and source term estimation in discharged fuel

Study of Burnup Reactivity and Isotopic Inventories in REBUS Program

SPentfuel characterisation Program for the Implementation of Repositories

EFFICIENCY CALIBRATION STUDIES FOR GAMMA SPECTROMETRIC SYSTEMS: THE INFLUENCE OF DIFFERENT PARAMETERS

2 Korea Atomic Energy Research Institute, Yuseong gu, Daejeon, South Korea, Abstract

Determination of research reactor fuel burnup

PWR and BWR Fuel Assay Data Measurements

Estimation of Performance of an Active Well Coincidence Counter Equipped with Boron-Coated Straw Neutron Detectors 13401

Application of Spectral Summing to Suspect Low Level Debris Drums at Los Alamos National Laboratory

DEVELOPMENT OF HIGH RESOLUTION X-RAY CT TECHNIQUE FOR IRRADIATED FUEL ASSEMBLY

Application of LaBr 3 detector for neutron resonance densitometry

Los Alamos. OF nm LA-"'- Title: HYBRID KED/XRF MEASUREMENT OF MINOR ACTINIDES IN REPROCESSING PLANTS. S. T. Hsue and M. L.

Background Reduction Using Collimators on a Portable HPGe Nuclide Identifier

Minimum Detectable Activity Estimates for a Germanium-Detector Based Spectroscopic Portal Monitor

DESIGN AND PERFORMANCE OF THE INTEGRATED WASTE ASSAY SYSTEM (IWAS)

Gamma-Spectrum Generator

EFFICIENCY AND RESOLUTION OF GERMANIUM DETECTORS AS A FUNCTION OF ENERGY AND INCIDENT GEOMETRY

arxiv:nucl-ex/ v1 29 Aug 2005

The Concentration of 236 Pu Daughters in Plutonium for Application to MOX Production from Plutonium from Dismantled US Nuclear Weapons

Measurement Methods Training and Software Developed for Inspection of Small Gaseous Diffusion Plants

REACTOR POWER HISTORY FROM FISSION PRODUCT SIGNATURES. A Thesis DAVID J. SWEENEY

Observables of interest for the characterisation of Spent Nuclear Fuel

Proliferation-Proof Uranium/Plutonium Fuel Cycles Safeguards and Non-Proliferation

Transcription:

The Use of Self-Induced XRF to Quantify the Pu Content in PWR Spent Nuclear Fuel William S. Charlton, Daniel Strohmeyer, Alissa Stafford Texas A&M University, College Station, TX 77843-3133 USA Steve Saavedra Oak Ridge National Laboratory, Oak Ridge, TN 37831 USA Andrew S. Hoover and Clifford Rudy Los Alamos National Laboratory, Los Alamos, NM 87545 USA Abstract: The development of techniques for the accurate quantification of the plutonium content in spent nuclear fuel would provide significant advances for shipper/receiver differences and for input accountability at reprocessing facilities. Several techniques have been studied previously for achieving this goal but these have met with limited success. Due to the radioactive nature of spent fuel, decay energy is being deposited in the fuel at a relatively constant rate. That decay energy leads to self-induced x-ray fluorescence of the uranium and plutonium atoms in the fuel. These resulting x-rays are then emitted by the fuel rod and can be measured in an appropriately designed and implemented instrument. The presence of uranium x-rays has been observed on numerous occasions; however, due to its dilute nature in the spent fuel and the presence of a large background, the plutonium x-rays have only been observed in a small number of experiments and generally with fuel containing very large loadings of plutonium. In this work, a feasibility study was conducted using both Monte Carlo simulations and measurements of PWR spent fuel rods at Oak Ridge National Laboratory as part of the Coupled End-to-End (CETE) demonstration. This feasibility study demonstrated the measurability of the plutonium x-rays for PWR spent fuel with burnups ranging from 35 to 70 GWd/MTU and the potential application of this technique as a quantitative assay tool. Keywords: spent fuel; nondestructive analysis; x-ray fluorescence; plutonium quantification 1. Introduction One of the most difficult non-destructive assay (NDA) problems in safeguards is quantitative measurements of plutonium (Pu) in spent nuclear fuel. Light water reactor spent fuel contains approximately 1% Pu and 3% fission products with the remainder uranium (U). The fission products produce an intense gamma-ray field that obscures the Pu gamma rays. The radioactive decay of the spent fuel however will induce fluorescence in the U and Pu and produce K x-rays. These x-rays might prove to be a useful NDA signature of the Pu to U ratio in the spent fuel. The U and Pu K x-rays range from about 94 to 120 kev. The energy and relative intensities of these x- rays is shown in Table 1. Since the bulk of the spent fuel is U, the Pu x-rays with similar energy to the U x-rays will likely be obscured. However, the 103.7 kev K 1 x-ray of Pu is relatively well separated from the U x-rays and may be measureable in spent fuel.

Table 1. Uranium and plutonium x-ray data [1]. X Ray Energy (kev) Relative Intensity Uranium Plutonium Uranium Plutonium K 1 98.44 103.76 100 100 K 2 94.67 99.55 61.9 62.5 K 1 111.30 117.26 22.0 22.2 K 2 114.50 120.60 12.3 12.5 K 3 110.41 116.27 11.6 11.7 Measurement of U and Pu x-rays has been performed previously. This signature is routinely measured in small aliquots of spent fuel dissolutions [2]. However, the plutonium K x-rays have only rarely been measured in solid spent fuel. Observations of the 103.7 kev Pu x-ray from spent nuclear fuel previously have been reported by A. Bushuev et al. in 1982 [3] and C. Rudy et al. in 2005 [4]. In the latter paper, x- ray measurements and determinations of Pu/U ratios of BN-350 fast breeder reactor fuel that had been cooling for 5-10 years were reported. The ratio of the 103.7 kev peak area to the continuum was low and the peak areas had large errors, but the detector being used for this measurement was not specifically designed to measure these x-rays. Thus, it is expected that an optimized and collimated detector system might be capable of measuring this signal for spent fuel in a dry hot cell. In this work, a study was performed to determine the feasibility of using self-induced x-ray fluorescence (XRF) as a direct measure of the Pu content of solid spent fuel pins in a dry hot cell. Experiments were performed on spent fuel rods at Oak Ridge National Laboratory (ORNL) to determine if a well designed measurement system could measure the 103.7 kev x-ray from Pu and if it could be correlated to Pu content in the fuel. Simulations were also performed to aid in detector design, data analysis, and fundamental understanding of this technique. 2. Spent Fuel Measurements Three measurement campaigns were performed at ORNL in May 2008, July 2008, and January 2009. All measurements were performed in the hot cells at Building 3525 at ORNL and all measurements were for PWR spent fuel in individual rod segments. The measurements in May 2008 failed to produce a viable Pu x-ray measurement due to the large Compton continuum from gamma-ray interactions in the fuel, detector, shielding, and other materials. The detector arrangement was simulated with MCNPX [5] and these simulations suggested possible changes to the detector shielding which would decrease the Compton continuum by as much as a factor of 10. In July 2008, modifications to the detector shielding were performed based on the results from these simulations and this resulted in a measureable Pu x-ray signal. In January 2009, additional modifications to the detector and experimental arrangement were performed to provide an increased signal-to-noise ratio. Thus, Pu/U x-ray ratios were shown to be measureable for LWR spent fuels with burnups ranging from 30-70 GWd/tU. The description in the remainder of this paper is limited to the January 2009 measurement campaign which covered a burnup range of 25-50 GWd/tU. 2.1 Spent Fuel Characteristics All measurements described here were performed on rod D5 from assembly NJ05YU from TMI-1. This rod had an average burnup of approximately 50 GWd/tU. The characteristics of the rod and assembly are given in Table 2. The rod had been previously cut into segments of varying lengths. These segments were then packaged into stainless steel shipping tubes with a thickness of approximately 0.16 cm. The rods were measured while still in the shipping tubes.

Table 2. Characteristics of TMI-1 spent fuel rod D5 from assembly NJ05YU [6]. Parameter Value Assembly and reactor data Design B&W PWR Lattice geometry 15x15 Rod pitch (cm) 1.4427 Number of fuel rods 208 Number of guide tubes 16 Number of instrumentation tubes 1 Assembly pitch (cm) 21.8110 Fuel rod data Fuel material UO 2 Fuel pellet density (g/cm 3 ) 10.196 Fuel pellet diameter (cm) 0.9362 Clad material Zircaloy-4 Clad inner diameter (cm) 0.9576 Clad outer diameter (cm) 1.0922 Guide/instrument tube data Guide/ instrumentation tube material Zircaloy-4 Guide tube inner diameter (cm) 1.2649 Guide tube outer diameter (cm) 1.3462 Instrumentation tube inner diameter (cm) 1.1201 Instrumentation tube outer diameter (cm) 1.2522 Figure 1. Collimator, fuel rod, and rod positioning system arrangement inside hot cell.

Figure 2. Detector and collimator arrangement outside hot cell. 2.2 Experimental Arrangement and Procedure The spent fuel rod segments were placed in the hot cell in building 3525 at ORNL. This hot cell contains a rod positioning system (shown in Figure 1) that allowed the rod to be moved laterally in front of a collimator that would collimate gamma rays into a thin beam projecting through the hot cell wall. The collimator was 65.75 long and the hot cell walls were 36.0 thick. The collimator extended 27.5 into the hot cell. The fuel rod was 8 from the end of the collimator inside the hot cell. There was an extension on the collimator that extended 12.25 outside the hot cell wall. A Canberra Model GL0515R planar detector was placed directly against this extension (shown in Figure 2). The tungsten collimator on the detector was removed and no shielding was placed around the detector. Thus, the detector front face was 73.75 from the fuel rod. A similar set of measurements were also performed with a coaxial detector to acquire a broad energy spectrum for each location as well. Spectra were collected from various positions along the fuel rod with the majority of positions being near the top of the fuel rod (where the fuel burnup changed the most with change in distance from the end of the rod). Count times varied from 1-16 hours. Detector dead times ranged from 6-16% depending upon the rod position. With the detector and collimator in this arrangement and using fairly long count times, the 103.7 kev x-ray peak from Pu was clearly visible. An example spectrum is shown in Figure 3. Figure 3. Measured spectra from TMI spent fuel rod D5 showing the Pu x-ray peak at 103.7 kev.

Figure 4. Example peak fit for Pu x-ray peak at 103.7 kev using the GENIE 2000 interactive peak fit. 2.3 Spectrum Analysis The measured spectra were analyzed using Canberra s GENIE 2000 interactive peak fit. An example peak fit is shown in Figure 4. As can be seen, there is a peak at 105.3 kev from Eu-155 that is near to the Pu K x-ray peak, but with a high resolution detector, these peaks are easily separable. The spectra were analyzed to acquire count rates for the U K x-ray at 98.4 kev, the Pu K x-ray at 103.7 kev, the Cs-134 gamma ray at 604 kev, and the Cs-137 gamma ray at 661 kev. The ratio of Cs-134/Cs-137 is an indicator of fuel burnup [7]. The measured Pu/U K x-ray ratio was then plotted versus the measured Cs- 134/Cs-137 gamma ray ratio (Figure 5). As can be seen, a strong correlation between Pu/U x-ray ratio and Cs-134/Cs-137 gamma ray ratio is found. Figure 5. Measured Pu/U x-ray ratio versus measured Cs-134/Cs137 gamma ray ratio for TMI fuel rod D5.

Pu/U Atom Ratio 3. Simulations and Results Destructive analysis of the samples measured for rod D5 had not yet been performed at the time of writing this paper. Thus, simulations were used to relate the measured Cs-134/Cs-137 gamma-ray ratio to burnup and expected Pu/U content in the spent fuel to prove the feasibility of this technique. A twodimensional TransLAT simulation [8] was used to determine the expected spent fuel isotopics as a function of fuel burnup and radial position in the fuel pin. This simulation included 20 radial fuel regions in the fuel pin. The fuel pin was burned from 0 to 70 GWd/tU and included the declared decay time for the TMI-1 D5 rod from time of discharge to time of measurement. The calculated average Pu/U atom ratio in the fuel pin versus Cs-134/Cs-137 atom ratio in the pin is shown in Figure 6. When correlated to the measured Cs-134/Cs-137 ratio from Figure 5, we find that the Pu/U atom ratio predicted using Figure 6 is very low. For example a measured Cs-134/Cs-137 ratio of 0.025 would correspond to a measured Pu/U ratio of approximately 0.016 using Figure 5. However, the same Cs- 134/Cs-137 ratio of 0.025 would correspond to a Pu/U ratio of 0.003 from Figure 6. It was discovered that this is because the measured Pu/U x-ray ratio is heavily influenced by the concentration of Pu on the outer surface of the fuel pin due to the strong attenuation of the 103.7 kev x-rays in the fuel. Figure 7 shows the Pu concentration as a function of radial position in the fuel for several burnups. The U concentration only changes slightly as a function of position within the pin, but the Pu concentration is almost a factor of 5 higher on the outer surface of the pin than in the center of the pin. The Cs-134/Cs- 137 atom ratio change only slightly (about 5-10%) as a function of radial position in the pin as well, and there is only minimum attenuation of the 605 and 661 kev gamma rays from Cs-134 and Cs-137 regardless of where in the pin they are produced in the pin. Thus, the measured Cs-134/Cs-137 gammaray ratio is a good indicator of the average Cs-134/Cs-137 atom ratio in the entire pin. The TransLAT calculated Pu/U atom ratio on the surface of the fuel pin was correlated to the average Cs- 134/Cs-137 atom ratio for the pin. This correlation was then used to infer the Pu/U atom ratio at the surface of the pin from the measured Cs-134/Cs-137 gamma-ray ratio. A plot of the measured Pu/U x-ray ratio versus the inferred Pu/U atom ratio at the surface of the pin is shown in Figure 8. This plot shows that the measured x-ray ratio is a good measure of the Pu/U concentration at the surface of the pin. The Pu/U concentration at the surface of the pin can be directly related to the average Pu/U ratio for the entire pin given knowledge of the pin dimensions (which we would expect would be known). Thus, it is feasible to measure the Pu/U x-ray ratio and Cs-134/Cs-137 gamma ray ratio for LWR spent fuel pins with burnups from 30-70 GWd/tU and use this data to determine the Pu/U atom ratio in the pin. 0.009 0.008 0.007 0.006 0.005 0.004 0.003 0.002 0.001 0 0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 Cs134/Cs137 Atom Ratio Figure 6. Calculated volumetrically averaged Pu/U atom ratio versus Cs-134/Cs-137 atom ratio for TMI fuel rod D5.

Measured Pu/U X-Ray Ratio Pu Concentration (g/cm 3 ) 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0.00 0.10 0.20 0.30 0.40 0.50 Radius (cm) 10 GWd/tU 30 GWd/tU 65 GWd/tU Figure 7. Calculated Pu concentration versus radius for TMI fuel rod D5. 0.025 0.02 0.015 y = 1.019x R² = 0.9638 0.01 0.005 0 0 0.005 0.01 0.015 0.02 0.025 Inferred Pu/U Atom Ratio at Fuel Pin Surface Figure 8. Measured Pu/U x-ray ratio versus Pu/U atom ratio at fuel pin surface inferred from the measured Cs- 134/Cs-137 gamma-ray ratio. 4. Conclusion Measurements and simulations were used to demonstrate that with a properly configured detector system, it is feasible to measure the Pu/U atom ratio at the surface of a fuel pin using measurements of the 103.7 kev K x-ray from Pu. Since the Pu/U atom ratio at the surface of the pin is directly related to the average Pu/U concentration for the pin, this implies that this technique will be feasible for measuring the Pu/U concentration in an LWR spent fuel pin. However, this requires knowledge of the fuel pin design and operating history to properly correlate surface Pu to average Pu for a pin. Also, the count times that were used in these measurements were longer than would be acceptable in most applications. These measurements were also restricted to individual fuel pins and it is unlikely that this technique could be

extrapolated to entire fuel assemblies. For future work, optimized detector systems and measurement approaches will be explored to develop a system that can measure the Pu/U x-ray ratio with shorter count times. Also, the sensitivity of this method to variations in system parameters will be studied to determine the expected accuracy of this technique. 5. References 1. D. Reilly, N. Ensslin, and H. Smith, Passive Nondestructive Assay of Nuclear Materials, United States Nuclear Regulatory Commission, Washington, DC, NUREG/CR-5550, 1991. 2. H. Ottmar and H. Eberle, The Hybrid K-edge/X-XRF Densitometer: Principles-Design-Performance, KfK 4590, Kernforschungszentrum Karlsruhe, 1991. 3. A. V. Bushuev, V. I. Galkov, A. V. Zbonarev, A. F. Zolotov, A. A. Kutuzov, N. A. Mel'nichenko, V. N. Ozerkov and V. V. Chachin, A Nondestructive Method of Determining the Pu/U ratio in Fast Reactor Fuel Elements, Based on x-ray Spectrometry, Atomic Energy, vol. 53, no. 5, pp 776-778, 1982. 4. C. Rudy, P. Staples, K. Seredniuk, and I Yakovlev, Determination of Pu in Spent Fuel Assemblies by X-Ray Fluorescence, Proceedings of the 2005 INMM Annual Meeting, Phoenix, AZ, 2005. 5. D.B. Pelowitz, et al., MCNPX 2.7A Extensions, LA-UR-08-07182, Los Alamos National Laboratory, 2008. 6. Summary Report of Commercial Reactor Criticality Data for Three Mile Island Unit 1, TDR-UDC-NU- 000004 Rev 01, Bechtel SAIC Company, Las Vegas, Nevada, 2001. 7. C. Willman, A. Hakansson, O. Osifo, A. Backlin, and S.J. Svard, Nondestructive Assay of Spent Nuclear Fuel with Gamma-Ray Spectroscopy, Annals of Nuclear Energy, vol. 22, pp. 427-438, 2006. 8. TransFX Computer Software Manuals: Advanced Particle Transport Software Using Three- Dimensional Deterministic Methods in Arbitrary Geometry, Transware Enterprises, 2001.