Thermal Desorption Technical Support

Similar documents
Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ

Application Note. Application Note 081 Innovative Cryogen-Free Ambient Air Monitoring in Compliance with US EPA Method TO-15. Abstract.

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Target Compound Results Summary

INNOVATIVE PRODUCTS, SUPERIOR SUPPORT. Presenter: Anne Jurek, Senior Applications Chemist, EST Analytical

Determination of Volatile Organic Compounds in Air

US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS

EPA TO-17 Volatile Organic Compounds

Methanol Extraction of high level soil samples by USEPA Method 8260C

Maximizing Sample Throughput In Purge And Trap Analysis

US EPA Method with the Tekmar Lumin P&T Concentrator, AQUATek LVA and Agilent 7890B GC/5977A MS

Analysis of Low Level Volatile Organic Compounds in Air Anne Jurek

Validation of USEPA Method Using a Stratum PTC and the New AQUATek 100 Autosampler

TD-100. Automated thermal desorber. Universal TD system for up to 100 RFID-tagged or untagged tubes

Using Hydrogen as An Alternative Carrier Gas for US EPA 8260

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

CIA Advantage-xr. Cryogen-free automated canister and whole-air sampling system

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Analysis of Volatile Organic Compounds Using USEPA Method 8260 and the 4760 Purge and Trap and the 4100 Autosampler

Roger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1

Validation of Volatile Organic Compound by USEPA. Method 8260C. Application Note. Abstract. Introduction. Experimental-Instrument Conditions

CALA Directory of Laboratories

Analysis of Volatile Organic Compounds in Water and Soil by EPA Method 8260 with the Atomx Concentrator/Multimatrix Autosampler

SUMMARY REPORT OF AIR MONITORING FOR LEED CERTIFICATION PHASE 2 SWANSFIELD ELEMENTARY SCHOOL 5610 CEDAR LANE COLUMBIA, MD PREPARED FOR:

Validation of USEPA Method Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS

Solid Phase Micro Extraction of Flavor Compounds in Beer

Analysis of Volatile Organic Compounds in Soil Samples by EPA Method 8260 with The Stratum PTC and SOLATek 72 Multi-Matrix Autosampler

Validation of Environmental Water Methods on One System: Considerations for Sample Volume, Purge Parameters and Quality Control Parameters

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Exploring US EPA Method 524 Purge and Trap Variables: Water Vapor Reduction and Minimizing Cycle Time

The following report includes the data for the above referenced project for sample(s) received on 5/15/2017 at Air Toxics Ltd.

A Comparison of Volatile Organic Compound Response When Using Nitrogen as a Purge Gas

Validation of USEPA Method 8260C Using Teledyne Tekmar Atomx, and Perkin-Elmer Clarus 600 GC/MS

Analytical Trap Comparison for USEPA Method 8260C

Optimizing. Abstract: is standardd. procedures. altered to

Rapid Determination of TO-15 Volatile Organic Compounds (VOCs) in Air

STANDARD OPERATING PROCEDURES

Analysis. Introduction: necessary. presented. Discussion: As part of be carried. consistent and reliable data. (MoRT) to.

Meeting NJ Low Level TO-15 Air Testing Method Requirements

Series 2 Air Server Automated canister and on-line air/gas analysis

Optimal VOC Method Parameters for the StratUm PTC Purge & Trap Concentrator

U.S. EPA VOLATILE ORGANICS METHOD USING PURGE AND TRAP GC/MS

Enhanced Preconcentrator for the Analysis of Vapor Phase Volatile Organic Compounds

Optimizing of Volatile Organic Compound Determination by Static Headspace Sampling

System and JUREK ANNE. Introduction: in an in purge and. trap sampling. Discussion: As part of. consistent and reliable data. (MoRT) to.

Helium conservation in volatile organic compound analysis using U.S. EPA Method 8260C

Application Note 032

OREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation ALS Environmental - Simi Valley

2017 EPA Method Update Rule and EPA Method 624.1

Headspace Technology for GC and GC/MS: Features, benefits & applications

Thermal Desorption Technical Support

Electronic Supplementary Material Experimentally Validated Mathematical Model of Analyte Uptake by Permeation Passive Samplers

R.E.A.C.T. Roxbury Environmental Action CoaliTion P.O. Box 244 Ledgewood, N.J Website:

Ed George and Anaïs Viven Varian, Inc.

Maximizing Production While Minimizing Costs

Optimizing Standard Preparation

National Pollutant Discharge Elimination System (NPDES); BADCT Limits for Volatile Organic Compounds

Performance of a Next Generation Vial Autosampler for the Analysis of VOCs in Water Matrices

A Single Calibration Method for Water AND Soil Samples Performing EPA Method 8260

AUTONOMOUS, REAL TIME DETECTION OF 58 VOCS IN THE PANAMA CANAL

Optimal Conditions for USEPA Method 8260B Analysis using the EST Analytical Sampling system and the Shimadzu GCMS-QP2010s

Solid Phase Micro Extraction of Flavor Compounds in Beer

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application

Optimization of 1,4-Dioxane and Ethanol Detection Using USEPA Method 8260 Application Note

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

1. Introduction. 2. Sampling Activities

Date Issued: April 01, 2013 Expiration Date: June 30, 2013

BIO-CHEM Laboratories, Inc. Work Order Sample Summary. CLIENT: CTRA Project: 6454 T Lab Order: A 6454 Aqueous 3/1/2013.

TDTS. Keywords. Introduction. TD Operation; Calibration; Impedance; Discrimination

CALA Directory of Laboratories

Method 8260C by Purge and Trap Gas Chromatography Mass Spectrometry using the Clarus SQ 8

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

In-Tube Extraction Sample Preparation for Gas Chromatography

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

Solid Phase Microextraction of Cyanogen Chloride and Other Volatile Organic Compounds in Drinking Water with Fast Analysis by GC-TOFMS

Application News AD Quantitative Determination of Volatile Organic Compounds in Drinking Water by EPA Method with Headspace Trap GC-MS

COMPLIANCE EMISSIONS TEST California Dept. of Public Health Standard Method Version 1.1 and FloorScore Flooring Evaluation

Optimization of Method Parameters for the Evaluation of USEPA Method Using a Purge and Trap with GC/MS

Vapor Intrusion Sampling Options: Performance Data for Canisters, Badges, and Sorbent Tubes for VOCs

Study of Residual Solvents in Various Matrices by Static Headspace

TO-17 Extending the Hydrocarbon Range above Naphthalene for Soil Vapor and Air Samples Using Automated

January 19, Dear Mr. Nightingale:

TDTS 16 Round-the-clock, on-line and cryogen-free monitoring of hydrocarbons from acetylene to trimethylbenzene in ambient air

A Single Calibration for Waters and Soil Samples Performing EPA Method Anne Jurek Applications Chemist

Measuring Environmental Volatile Organic Compounds by U.S. EPA Method 8260B with Headspace Trap GC/MS

Accepted for publication in Analytical Chemistry, August, 2011 SUPPORTING INFORMATION FOR. address:

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

Applying the Agilent 5977A MSD to the Analysis of USP<467> Residual Solvents with the 7697A Headspace Sampler and 7890B GC

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Copyright 2009 PerkinElmer LAS and CARO Analytical Services, Inc.

BIO-CHEM Laboratories, Inc. Work Order Sample Summary. CLIENT: Cascade Thornapple River Assoc. Project: Water Analysis Lab Order:

Date: March 6, 2008 RWDI Reference #: W B Pages (Including Cover):

Residual solvents analysis using an Agilent Intuvo 9000 GC system

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

ANALYTICAL REPORT. Job Number: Job Description: Transform Complete

Application. Gas Chromatography February Introduction

NIST gas standards containing volatile organic compounds in support of ambient air pollution measurements

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Texas Commission on Environmental Quality INTEROFFICE MEMORANDUM

Transcription:

Thermal Desorption Technical Support Note 86a: US EPA Method TO-17 for Monitoring Air Toxics in Ambient Air Using Sorbent Tubes and Automated, Cryogen-free Thermal Desorption Application Note Environmental, Tube, TO-17, Air Monitoring Introduction Volatile (vapor-phase) organic air toxics or Hazardous Air Pollutants (HAPs) are monitored in many industrial and urban environments as a measure of air quality. They range in volatility from methyl chloride to hexachlorobutadiene and trichlorobenzenes, and include polar as well as nonpolar compounds. Several national and international standard methods have been developed for air toxics and related applications including US EPA Method TO-17 (Determination of volatile organic compounds in ambient air using active sampling onto sorbent tubes). In response to increasing demand for ambient air toxics measurement, cryogen free thermal desorber (TD) technologies have been developed, presenting an automated, method compliant analytical platform for both tubes and canisters (for US EPA Method TO-1, see TDTS 81). The latest systems typically feature innovations such as repeat analysis for tubes, together with internal standard addition options for both canister and tube operation. Description of the TD-GC/MS Analytical System The analytical system used for this study comprised a Markes International Series ULTRA-UNITY TD (Figure 1) coupled to a GC/MS. Using this TO-17 compliant system, the sorbent tubes were heated in a flow of carrier gas transferring the analytes to an electrically cooled, sorbent-packed focusing trap inside the UNITY. Figure 1. ULTRA-UNITY. Extensive evaluation work was carried out to determine the best combination of sorbents and trapping temperatures for the focusing trap. A combination of Tenax, Carbopack X and Carboxen sorbents held at a trapping temperature of C, was ultimately found to work best, offering both quantitative recovery of target compounds and selective elimination of water.

N.B. Quantitative recovery of compounds as volatile as propylene from purge volumes up to L has also been demonstrated using this trap under these focusing conditions. Once the process of transferring vapors from the sample/sorbent tube to the focusing trap was complete (primary desorption), the trap was purged with dry carrier gas in the sampling direction to remove residual water. Then, the flow of carrier gas was reversed, and the trap heated rapidly. The retained organics were desorbed into the carrier gas stream and transferred/injected into the GC analytical column. Desorption of a UNITY focusing trap is so efficient, that splitless analysis is possible without significant peak broadening; that is, all of the retained organics can be transferred to the analytical column in a narrow band of vapor, ensuring optimum sensitivity. Air sampling tubes Air Toxic Analyzer (ATA) tubes, packed with a combination of Carbograph 1TD and Carboxen, were used for most of this study. This sorbent combination has demonstrated quantitative retention of air toxics, including the most volatile target compounds, from over L* of air at C. Pumped air sampling flow rates were maintained at ml/min. Universal tubes packed with Tenax TA, Carbograph 1TD, and Carboxen were used for some experiments. Universal tubes limit retention volumes to 1 L for the most volatile air toxics, but facilitate analysis of labile monoterpenes such as D-limonene. *Note: Breakthrough volumes can be compromised by high humidity or elevated ambient temperatures. Analytical Conditions This project was carried out using an Agilent J&W DB 6 column and a mixed air toxic standard containing over 6 analytes, ranging in polarity and volatility. Sample preparation A 6 component 1 ppm gas standard in nitrogen, available from Markes International (p/n CGS1-1PPM), in combination with an air actuated 6-port Valco valve was used to inject 1 ml aliquots of standard gas, carried in pure nitrogen, into the sorbent tubes (Figure ). Parameter UNITY parameters Cold trap: Tubes: Value Cold trap low temperature: C Tube desorption temperature: C Tube desorption time: Trap purge time: Cold trap high temperature: Split ratio: Trap heating rate: Markes Air Toxic Analyser/Soil Gas trap (p/n U-T1ATA-S) Markes Air Toxic Analyser tubes (p/n C AXXX-7) Markes Universal stainless steel tubes (p/n C-AXXX-66) packed with a combination of Tenax, Carbograph 1TD and Carboxen minutes. minutes C for minutes splitless or :1 outlet split C/s TD flow path: C GC parameters Carrier gas: He Column: Agilent DB-6, 6 m. mm, 1.8 µm Constant pressure mode: Temperature program: MS conditions psi MS source temperature: C MS quadrupole temperature: C MSD transfer line temperature: C Full scan mode mass range: C ( minutes), C/min to C ( minutes) - amu 1 ml Standard loop 1 ml Standard loop Needle valve Needle valve Standard out Standard out Standard in Flow meter Carrier in Sample tube Stage 1: 1 ml loop filled with standard Standard in Flow meter Carrier in Sample tube Stage : Carrier flushes standard into the tube Figure. Apparatus for loading 1 ml aliquots of standard gas onto sorbent tubes in a stream of pure nitrogen.

Results and Discussion Figure A shows the chromatogram obtained for a sample equivalent to 1 L of 1 ppb standard analyzed splitless. Figure B shows the chromatogram obtained for a sample equivalent to 1 L of 1 ppb standard analyzed with a :1 outlet split. The peak at. minutes was due to SO released from the carbon molecular sieve sorbent used at the back of the sampling tubes. 8 6 8 6 18 16 1 1 8 6 1 SO 6 7 8 9 1,1 11 1,16 1 18,19 17, 6,7 1 8 9 1 8 6 7 9 1 6 Figure A. Sample equivalent to 1 L of a 1 ppb standard analyzed splitless using ATA tubes and an Agilent J&W DB-6 column. 8,9 7,1 6 8 7 1 9 6 61 6 6 8 8 61 6 6 8 SO 1 1,16 8,9 16 1 8 1 6 7 11 8 9 1,1 18,19 17 1,6,7 1 8 9 6 7 9 7 6 1,1 6 7 8 1 Figure B. Sample equivalent to 1 L of a 1 ppb standard analyzed with a :1 split using ATA tubes and an Agilent J&W DB-6 column. 9 6

Table 1. Elution order for the air toxics standard run on an Agilent J&W DB-6 column. 1. Propylene. Dichlorodifluoromethane. 1,-Dichlorotetrafluoroethane. Methyl chloride. Chloroethane 6. 1,-Butadiene 7. Vinyl chloride 8. Methyl bromide (bromomethane) 9. 1,-Dichloroethane. Trichlorotrifluoroethane (Freon 11) 11. Ethanol 1. 1,1-Dichloroethylene 1. 1,1,-Trichlorotrifluoroethane 1. Acetone 1. Carbon disulfide 16. Isopropyl alcohol 17. Methylene chloride 18. tert-butyl methyl ether 19. cis-1,-dichloroethylene. n-hexane 1. 1,1-Dichloroethane. Vinyl acetate. trans-1,-dichloroethylene. Methyl ethyl ketone. Ethyl acetate 6. Tetrahydrofuran 7. Chloroform 8. 1,1,1-Trichloroethane 9. Cyclohexane. Carbon tetrachloride 1. Benzene. n-heptane. Trichloroethylene. 1,-Dichloropropane. 1,-Dioxane 6. Bromodichloromethane 7. cis-1,-dichloropropene 8. Methyl isobutyl ketone 9. Toluene. trans-1,-dichloropropene 1. 1,1,-Trichloroethane. Tetrachloroethylene. Methyl n-butyl ketone. Dibromochloromethane. 1,-Dibromoethane 6. Chlorobenzene 7-) o-, m-, p-xylene + ethylbenzene 1 Styrene Tribromomethane 1,1,,-Tetrachloroethane. Trimethylbenzene. Trimethylbenzene 6. 1-Ethyl--methyl benzene 7. Dichlorobenzene 8. Dichlorobenzene 9. Chloromethylbenzene (alpha) 6. Dichlorobenzene 61. 1,,-Trichlorobenzene 6. Hexachloro-1,-butadiene 6 Original data 1 1 Figure. 1 L of a 1 ppb air toxics standard, as shown in Figure B. Note the minor baseline anomaly due to residual water early in the run and increasing column bleed and noise as the GC oven reaches its top temperature.

ClearView reprocessed data Note clean selected ion spectrum of Freon 11 (peak ) Original data S/N=1:1 S/N = :1 Minimum detection limits were found to be below.1 ppb for all 6 components tested under both :1 split and splitless conditions, assuming a minimum 1 L air/gas sample volume and full scan mode. Measurement at lower concentrations could readily be achieved using the MS in Selected Ion monitoring (SIM) mode. Linearity Figure 7 illustrates system linearity under splitless conditions with R values of.99 for trichlorotrifluoroethane (Freon 11), dichlorodifluoromethane, chloroform, bromodichloromethane, and hexachloro-1,-butadiene. Note higher interferences in original data Figure. Expanded portions of the air toxics standard analyzed split (Figures B and ). Trap desorption efficiency leads to good peak shape and optimum sensitivity. Trap performance in this case is best illustrated by a close-up of the results for the challenging polar compound isopropyl alcohol (IPA) (Figure 6). Peak area 7 8 7 6 1 Freon 11 Dichlorodifluoromethane Chloroform Bromodichloromethane 6 8 1 1 L ppb equivalents Figure 7. Linearity plots from 1 to ppb standards collected using ATA tubes, and analyzed splitless. 9. 9. 9. Figure 6. Peak shape for IPA at 1 ppb analyzed splitless using ATA tubes and extracted mass ion.

Carryover for 1 L of ppb standard analyzed splitless was less than.% (Figure 8). SecureTD-Q Quantitative recollection of split flow facilitates repeat analysis and validation of TO-17 method/data. The repeat analysis of a sample equivalent to 1 L of 1 ppb air toxics standard, split :1 (Figure 9), demonstrates quantitative recovery across the analyte volatility range. Six repeat analyses were carried out on samples equivalent to a 1 L volume of 1 ppb standard under splitless conditions. Table shows example % relative standard deviation (RSD) for eight compounds, covering the volatility and polarity range of the standard. Typical RSDs were less than 6%. 8 6 8 16 1 8 CO SO 1 Figure 8. Carryover (blue) <.% from 1 L 1 ppb standard (black) analyzed splitless using ATA tubes. CO SO Artifact Recollected (Secure TD) sample - - - - - Original sample 1 Figure 9. Recollection and repeat analysis results from a 1 ppb standard analyzed using ATA tubes and a :1 outlet split. 6

Table. System reproducibility demonstrated using eight compounds, covering a typical range of air toxic volatilities and polarities (n = 6). Conditions: ATA tubes, splitless. Compound Dichlorodifluoromethane.8 1,-Butadiene. Methylene chloride. Freon 11 1.8 Chloroform 1.8 Benzene 6. Toluene 1.7 Hexachloro-1,-butadiene.8 % RSD Real air samples Real air samples were collected onto Universal sorbent tubes. A FLEC pump was used to sample at a flow rate of ml/min for minutes giving a total volume of 1 L in each case. Three different ambient locations were sampled: office, laboratory, and semirural outside air. Each sample tube was analyzed splitless using a full scan MS method from - amu. The data were processed using ClearView and overlaid (Figure ). 1 6 7 8 9 1,11 1 11 16 17 18 19,1 Office air 6 Abundance 1 Laboratory air Semirural outside air 1 Figure. Chromatograms from three 1 L real air samples collected using Universal sorbent tubes and desorbed splitless. Table. Selected compounds detected from three real air samples, run splitless. 1. Methanol. -Methyl butane. Ethanol. Acetone. Isopropyl alcohol 6. -Methyl pentane 7. -Methyl pentane 8. Hexane 9. Ethyl acetate. -Methyl hexane 11. Cyclohexane 1. -Methyl hexane 1. Heptane 1. Acetic acid 1. 1-Methy--propanol 16. Toluene 17. Hexanal 18. Xylene 19. Xylene. alpha-pinene 1. Cyclohexanone. alpha-myrcene. D-Limonene. Phenol. Menthol 6. -Phenoxy ethanol 7

Conclusions These results clearly demonstrate the fundamental sensitivity of the series ULTRA-UNITY Air Toxics Analyzer configuration run with GC/MS. Quantitative detection of TO-17 air toxics ranging from methyl chloride to hexachloro-1,-butadiene has been demonstrated down to.1 ppb on sorbent tubes, and even lower levels would be possible using the MS in SIM mode or sampling larger air volumes. Applications were performed under the stated analytical conditions. Operation under different conditions, or with incompatible sample matrices, may impact the performance shown. Reference 1. E. Hunter Daughtrey, K. D. Oliver, J. R. Adams, K. G. Kronmiller, W. A. Lonneman, W. A. McClenny. A comparison of sampling and analysis methods for low ppbc levels of volatile organic compounds in ambient air. J. Environ. Monit. 1,, 166-17. For More Information These data represent typical results. For more information on our products and services, visit our Web site at www.agilent.com/chem. www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 17 Printed in the USA July 6, 17 991-88EN