FLOW DIVIDERS "XV 3 serie" ENGLISH VERS:

Similar documents
BOLOGNA - ITALY UNIDIRECTIONAL PUMPS ENGLISH

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

XV-0P. unidirectional pump - series XV. STANDARD PUMP ø22 FLANGE - PARALLEL SHAFT. Technical data table. Dimensions table.

VOLUMEC. Valve Position Indicator 5

Thermohydrodynamic Lubrication Characteristics of High-Speed Tilting Pad Journal Bearings

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

Applied Fluid Mechanics

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS

External gear pump Type G3, Series 3X

INTERNATIONAL STANDARD

Flow Divider Type MH2FA, Series 4X (Differential lock) Size 12 to 32 up to 420 bar up to 300 L/min

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design

NATIONAL CERTIFICATE (VOCATIONAL) APPLIED ENGINEERING TECHNOLOGY NQF LEVEL 4 NOVEMBER 2009

Vane pump theory for mechanical efficiency

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1

Brakes. Dr. Mostafa Rostom A. Atia Associate Prof. M.Atia 1

Cartridge Valves Technical Information. Quick reference

Sliding Bearings. Fig.(1) (a) Full-journal bearing and (b) partial-journal bearing

UNI EN ISO 9001:2008 UNI EN ISO 14001:2004 BS OHSAS 18001:2007 EC DIRECTIVE 2014/34/EU (ATEX) CERTIFIED MANAGEMENT SYSTEM

Cooling Water Flow Regulator

Pneumatic Universal. Actuator MOTORIZED VALVES USE TECHNICAL FEATURES OF THE ACTUATOR. Data sheet

14:1400 (0206) KRAL Volumeter - OMG

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

2-way proportional throttle valve for block installation

ENERGY DISTRIBUTION ANALYSIS IN A LOW HEAD FRANCIS TURBINE DURING THERMODYNAMIC EFFICIENCY MEASUREMENTS

S.C. Rulmenti S.A. Barlad Romania Republicii Street No

CHAPTER 1 INTRODUCTION Hydrodynamic journal bearings are considered to be a vital component of all the rotating machinery. These are used to support

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features

Sliding Contact Bearings

Atlas Copco Air motors. A full range of compact, high performance air motors

Linear guide drives. Synchronous shafts The use of synchronous shafts enables several linear axes to be operated with one drive.

Chapter 3: Fundamentals of Mechanics and Heat. 1/11/00 Electromechanical Dynamics 1

RESEARCH ON AIRBORNE INTELLIGENT HYDRAULIC PUMP SYSTEM

R-Plus System Frontespizio_R_PlusSystem.indd 1 11/06/ :32:02

Flow rates to 485 l/min

Flow rates to 485 l/min

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

Non Newtonian Fluid Dynamics

Dimensions of propulsion shafts and their permissible torsional vibration stresses

RFM. 300 kpa (3 bar) Return Filters RFM. Ports: 3/8 2 1/2 Flow rates: l/min

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

Flow rates to 485 l/min

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

VK2 volume flow controller Overview

Prima range. Alifter range. magnetical driven pumps in thermoplastic materials TMP TMA. centrifugal. self-priming

Rotary modules.

Cooler-Bypass Thermostat Valve, Size 10

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min

Brueninghaus Hydromatik Rexroth A4VSG Pump

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H

Product description. Compact Modules. Characteristic features. Further highlights

New Way Porous Gas Bearings as Seals. Bearings Seals

WORK SHEET FOR MEP311

Rodless cylinders Series 1600

MECHANICAL CHARACTERISTICS OF STARCH BASED ELECTRORHEOLOGICAL FLUIDS

Frictional Characteristics of Thrust Bearing in Scroll Compressor

K 080/12 F 10 K 3-2X/.. Features

Investigation of basic elements loading and tension of heavy hydraulic presses for metallurgical production

143 EEX gerotor pump unit. For use in oil circulation systems in gas- and dust-ex-atmospheres

the foundation of any business starts here

Identification system for short product names. Changes/amendments at a glance. 2 Bosch Rexroth AG OBB omega modules R ( )

Applied Fluid Mechanics

Flow rates to 750 l/min

EVO Product SAE Flange Chart

Flow rates to 750 l/min

N. 1 ELECTRIC ARC FURNACE SECOND HAND 50 TONS. TAPPING CAPACITY

2016 Engineering Science. Higher. Finalised Marking Instructions

Cam Roller Guides. The Drive and Control Company. Service Automation. Electric Drives and Controls. Linear Motion and Assembly Technologies

SEM-2016(03)-II MECHANICAL ENGINEERING. Paper -11. Please read each of the following instructions carefully before. attempting questions.

DBS315 1-phase SIDE CHANNEL BLOWERS

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00

h p://edugen.wileyplus.com/edugen/courses/crs1404/pc/b02/c2hlch...

High Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters

2D - STRIP ANCHOR LIFTING SYSTEM

A 954 C HD. Technical Description Hydraulic Excavator. Machine for Industrial Applications

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8" Discharge: 8" Spherical solids handling: 3"

260A Tractor, Loader & Backhoe S/n & up

ELECTROHYDROSTATIC PUMP UNIT

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

HD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 8700 psi Nominal flow rate up to gpm us

(Refer Slide Time: 00:01:30 min)

LMP series Filter element according to DIN Maximum pressure up to 30 bar - Flow rate up to 2000 l/min

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

4/3-way servo solenoid directional control valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)

Polyflex JB and Micro-V Belt Drive Selection Procedures

Design of Restricted Orifice Surge Tank

Pressure transmitters for industrial applications MBS 32 and MBS 33

Flow rates to 475 l/min

Direct-operated 2/2-way compact solenoid valves Type EV210A

HRN/HRN-C Series Hydraulic Vane Rotary Actuators

Step 1: Mathematical Modeling

Variable Speed Tri-Rotor Screw Compression Technology

Part /Assy Parts List. Production Order. Badge, Perkins/Sabre M215C. Description

Stability of Water-Lubricated, Hydrostatic, Conical Bearings With Spiral Grooves for High-Speed Spindles

Series 3000 and XE-Series Engineering Data

Lecture 6 mechanical system modeling equivalent mass gears

Transcription:

FLOW DIVIDERS "XV serie" ENGLISH VERS:07-0-01 0 VERS:0-0-008

XV-D FLOW DIVIDER XV-G FLOW DIVIDER + MOTOR This is the flow divider standard version, it simply divide the incoming flow without allowing the phase correction The XV-G typology is the motorized version of the XV-D divider. It has a motor conneted to the flow divider elements. This solution is important when the incoming and/or outgoing pressure is below the minimum pressure required to start. Giving flow to the motor, help the flow divider rotation start. Typical use: plants with single effects hydraulic jack. The flow division error is lower than ± 1.% with a pressure difference between one element and another until 0 Bars. For bigger differences we can approximate an error increase of 1 % for each 1 0 additional bars. Vivoil Oleodinamica Vivolo s.r.l. - Società a Socio Unico - via Leone Gingburg - 00 Budrio (BO) Italy tel: +9 01 80689 fax: +9 01 800061

INTRODUCTION XV- A flow divider is made up of two or more modular elements (sections) with gears mechanically linked by an internal shaft that causes them to turn at the same speed. Unlike multiple pumps, in which the input power is mechanical (shaft connected to a motor), in a flow divider the input power is of a fluid-mechanical nature, i.e. a flow of oil under pressure parallelly supplies the modular elements, which are in turn connected to the hydraulic circuits serving the users. The portion of flow utilized by each element is solely determined by its nominal flow rate. Therefore, unlike standard static dividers with variable ports, the flow dividers do not cause dissipation and are also much more precise. The use of flow dividers in a system reduces the number of pumps necessary as well as the associated individual mechanical power takeoffs and complex mechanical couplers (with greater losses). Leaving aside small losses for the time being, at any given moment the total input power is equal to the sum of the powers supplied by all elements making up the flow divider. Therefore, if in an interval of time the power required by a hydraulic circuit is equal to zero (inactive drained circuit), the power supplied by the element feeding that circuit becomes available for the other elements, which may use it in their own circuits, also operating at higher pressures than the intake pressure. Most frequent applications of flow dividers Supply of two or more independent hydraulic circuits by means of a single pump, with an overall flow rate equal to the sum of the flow rates. Examples of this kind of application: - lifting platforms and bridges; - hydraulic bending presses and shearing machines; - hoisting of freight containers; - lubrication systems; - hydraulic opening / closing of gates; - automatic hydraulically-driven machines; - actuation of formwork for construction; - wood processing machinery; - conveyance of trolleys driven by hydraulic cylinders or motors; - equipment for the food industry; - military installations. Pressure amplifiers. When in a hydraulic system one user requires a much higher operating or peak pressure than all the others, it is more convenient to supply it by means of a flow divider than to upgrade the whole system to work with higher pressure. With a two-element flow divider flow may be discharged from the outlet of one element so that the pressure in the other will become much higher than that of the pump supplying the system. Examples of this kind of application: - presses with rapid approach - machine tools Constructive features FLOW DIVIDER BODY FLANGE AND COVER Extruded alloy Serie 00, heat treated and anodised Rp= N/mm (Yield Strength) Rm= N/mm (Breaking Strength) GEAR BUSH BEARINGS Special Heat Treated tin alloy with excellent mechanical features and high anti-friction capacity. Self-lubricating bushes DU Rp=0 N/mm (Yield Strength) Rm=90 N/mm (Breaking Strength) GEARS Steel UNI 786 GASKET A 77 Acrolonitrile Standard F 97 Viton FKM Rs=980 N/mm (Yield Strength) Rm=1 1 N/mm (Breaking Strength) 90 Shore, thermal resistance 1 0 C 80 Shore, thermal resistance 00 C Vivoil Oleodinamica Vivolo s.r.l. - Società a Socio Unico - via Leone Gingburg - 00 Budrio (BO) Italy tel: +9 01 80689 fax: +9 01 800061

XV-D FLOW DIVIDER "XV" Series Code: 9D NN CC Cm /rev 1 18 1 7 7 1 61 6 7 90 9D Flow Divider Typology NN Number of elements CC Displacement Code Example: Flow divider with two elements (same displacement): 9D XV-D / x 0 78 Example: Flow Divider with elements with different displacement (max 7): 9D 0 CC Displacem. XV-D / 1 +1 +1 + 86 NOTE: to define codes for flow dividers with more than 7 different displacement, please contact our sales department. Code 66 68 7 7 78 79 80 8 8 8 86 87 89 Table: 1 Max Pressure bar 00 00 80 0 0 0 0 0 0 0 0 1 0 00 1 80 1 0 One element flow rate l/min MIN RECOMMENDED MAX 18 1,, 1 7 1 6 7 6 66, 7, 8 7 60 6,, 76, 8 8 91 96 11 7 7,, 67, 80 91 99 1 08 11 7 1 1 6 1 8 1 0 1 8 1 80 REFERENCES: Cm /rev 1 18 1 7 7 1 61 6 7 90 A IN 66 68 71 7 80 8 89 9 9 98 1 0 1 06 111 11 1 Table: OUT 1 " BSP 1 / BSP 1 " BSP 1 / BSP 1 " BSP 1 / BSP 1 " BSP / BSP 1 " BSP / BSP 1 " BSP / BSP 1 " BSP 1 " BSP 1-1 / BSP 1-1 / BSP Table: Li = Distance between fixing hole centres (single displacement flow divider) Number of elements 6 7 8 9 1 0 11 1 1 1 1 1 6 0 06 1 0 0 0 60 66 76 9 98 1 8 6 7 90 61 0 60 66 68 6 68 71 7 76 786 8 8 97 06 1 9 8 6 7 60 680 690 7 77 79 0 8 80 86 880 90 90 9 806 8 86 860 890 90 9 96 980 998 1 08 1 06 1 076 1 09 11 9 96 967 99 1 00 1 06 1 09 111 11 11 6 11 91 1 1 1 7 1 68 1 1 08 1 07 1 098 11 0 11 1 1 0 1 1 66 1 90 1 1 1 1 78 1 1 8 1 1 11 8 1 0 1 9 1 6 1 1 0 1 1 91 1 1 8 1 1 7 1 1 7 1 1 89 1 61 6 1 6 1 1 0 1 0 1 60 1 00 1 0 1 00 1 0 1 1 600 1 60 1 680 1 71 0 1 760 1 790 1 890 1 6 1 8 1 91 1 1 90 1 6 1 689 1 7 1 7 1 788 1 8 1 876 1 91 1 96 07 1 6 1 86 1 6 1 6 1 70 1 790 1 8 1 87 1 91 0 1 96 006 0 1 0 1 8 1 688 1 71 1 7 1 80 1 8 1 9 1 987 06 06 1 0 1 69 08 7 1 1 1 8 1 88 1 90 01 0 080 1 6 1 78 0 6 7 86 66 1 90 1 9 01 07 1 0 8 0 7 0 9 0 61 660 0 066 098 1 6 1 0 90 8 0 78 68 6 786 8 99 in this table the number of inlets in function of the number of elements are indicated. Number of elements "IN" Number of inlets XD01 1 6 7 8 9 1 0 11 1 1 1 1 1 6 6 6 7 7 8 Vivoil Oleodinamica Vivolo s.r.l. - Società a Socio Unico - via Leone Gingburg - 00 Budrio (BO) Italy tel: +9 01 80689 fax: +9 01 800061 8

FLOW DIVIDER "XV" Series XV-D INTERNAL DRAIN In table 1 the functioning range of single flow divider elements is indicated. The higher is the feeding capacity ( q ), the higher is the precision of flow division, but in opposition there are losses of loading and higher noise. Therefore we suggest to feed the elements with capacities equal or a few superior to the ones indicated in the column " RECOMMENDED ". It's important remember to verify the capacities even in phase of flow reunion. The pressures indicated are to be considered as maximum of functioning, the flow divider is able to bear peaks of pressure 0% superior. How to calculate the "Li" and Lt measures of flow dividers: From table it is possible to obtain the Li measure for flow dividers up to 1 6 elements with equal displacements; for flow dividers with different elements or with more than 1 6 elements the "Li" and Lt measure have to be calculated by the following formula: 11 0 = + Li = [(n-1 ) x 60] + 11 0 + (A1 + A + A +.) n = Number of elements of flow divider A1... An = heights of elements of flow divider Lt = Li + 0 0 = 1 + 1 EXAMPLE: To obtain the measures Li and Lt of a flow divider with three elements (n=), XV-D 7 + + Distance between fixing hole centres Li = [(-1 ) x 60] + 11 0 + 7 + 8 + 98 =88 mm Total Lenght Lt = 88 + 0 = 1 8 mm In table the number of inlets in fuction of the number of elements are indicated. For flow dividers with many inlets, as they are all communicating it is even possible to use only one of them, by plugging the other ones. We suggest to use at least one 1 " BSP inlet every 00 l/min capacity and at least one 1-1 /" BSP inlet every 60 l/min capacity To obtain errors of division inferior to % there must be no difference of pressure between the elements superior to 0 bar. To obtain high precisions the respect of the following parametres is also important: Enviroment temperature: -1 0 c +60 c Oil temperature: +0 c +60 c Hydraulic oil based on hlp, hv (din 1 ) minerals Oil Viscosity 0 0 cst Oil filtering 1 0 µ Vivoil Oleodinamica Vivolo s.r.l. - Società a Socio Unico - via Leone Gingburg - 00 Budrio (BO) Italy tel: +9 01 80689 fax: +9 01 800061