JABLONSKI DIAGRAM 2/15/16

Similar documents
JABLONSKI DIAGRAM INTERACTIONS BETWEEN LIGHT AND MATTER LIGHT AS A WAVE LIGHT AS A PARTICLE 2/1/16. Photoelectric effect Absorp<on Emission ScaDering

ELECTROMAGNETIC SPECTRUM LEARNING CHECK 2/1/16. What experiment proved light behaves as a wave? What experiment proved light behaves as a par6cle?

Electronic Excitation by UV/Vis Spectroscopy :

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

Course Details. Analytical Techniques Based on Optical Spectroscopy. Course Details. Textbook. SCCH 211: Analytical Chemistry I

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

Spectroscopy: Introduction. Required reading Chapter 18 (pages ) Chapter 20 (pages )

Instrumental Analysis: Spectrophotometric Methods

Analytical Spectroscopy Review

Complete the following. Clearly mark your answers. YOU MUST SHOW YOUR WORK TO RECEIVE CREDIT.

25 Instruments for Optical Spectrometry

Introduction to Spectroscopic methods

Chem 434 -Instrumental Analysis Hour Exam 1

2001 Spectrometers. Instrument Machinery. Movies from this presentation can be access at

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Overview of Spectroscopy

Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

Spectroscopy Problem Set February 22, 2018

Spectroscopy. Page 1 of 8 L.Pillay (2012)

Lecture 0. NC State University

Skoog Chapter 7 Components of Optical Instruments

Chem 155 Midterm Exam Page 1 of 10 Spring 2010 Terrill

Ch 313 FINAL EXAM OUTLINE Spring 2010

Compact Knowledge: Absorbance Spectrophotometry. Flexible. Reliable. Personal.

CHEM*3440. Photon Energy Units. Spectrum of Electromagnetic Radiation. Chemical Instrumentation. Spectroscopic Experimental Concept.

Atomic Absorption Spectroscopy

levels. The signal is either absorbance vibrational and rotational energy levels or percent transmittance of the analyte

Chemistry 524--Final Exam--Keiderling Dec. 12, pm SES

Light- Ma*er Interac0ons CHEM 314

Spectrochemical methods

9/28/10. Visible and Ultraviolet Molecular Spectroscopy - (S-H-C Chapters 13-14) Valence Electronic Structure. n σ* transitions

Chem 310 rd. 3 Homework Set Answers

Basics of UV-Visible Spectroscopy *

two slits and 5 slits

World Journal of Pharmaceutical Research SJIF Impact Factor 8.074

Atomic Emission Spectroscopy

Outline of Recombinant DNA technology. Application of UV spectroscopy in recombinant DNA technology

Introduction to Chemical Research (CHEM 294) Introduction to Chemical Research (CHEM 294)

Chem Homework Set Answers

Chemistry Instrumental Analysis Lecture 3. Chem 4631

II. Spectrophotometry (Chapters 17, 19, 20)

Chapter 17: Fundamentals of Spectrophotometry

Characterisation & Use of Array Spectrometers

Assumed knowledge. Chemistry 2. Learning outcomes. Electronic spectroscopy of polyatomic molecules. Franck-Condon Principle (reprise)

Practical 1P4 Energy Levels and Band Gaps

Practical 1P4 Energy Levels and Band Gaps

Model Answer (Paper code: AR-7112) M. Sc. (Physics) IV Semester Paper I: Laser Physics and Spectroscopy

Singlet. Fluorescence Spectroscopy * LUMO

1/25/16 ANNOUNCEMENTS SELECTING AN ANALYTICAL METHOD

3 - Atomic Absorption Spectroscopy

Ultraviolet-Visible Spectroscopy

EMISSION SPECTROSCOPY

Chemistry Instrumental Analysis Lecture 8. Chem 4631

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

R O Y G B V. Spin States. Outer Shell Electrons. Molecular Rotations. Inner Shell Electrons. Molecular Vibrations. Nuclear Transitions

Chapter 17: Fundamentals of Spectrophotometry

INTRODUCTION Atomic fluorescence spectroscopy ( AFS ) depends on the measurement of the emission ( fluorescence ) emitted from gasphase analyte atoms

10/2/2008. hc λ. νλ =c. proportional to frequency. Energy is inversely proportional to wavelength And is directly proportional to wavenumber

Chapter 6 Photoluminescence Spectroscopy

CHAPTER 2. Preliminaries A Review of Optical Physics

Ultraviolet-Visible and Infrared Spectrophotometry

Ultraviolet-Visible and Infrared Spectrophotometry

Effects of Temperature and Concentration on the Rate of Photo-bleaching of Erythrosine in Water

Chemistry 2. Molecular Photophysics

What is spectroscopy?

Atomization. In Flame Emission

Reflection = EM strikes a boundary between two media differing in η and bounces back

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

24 Introduction to Spectrochemical Methods

LABORATORY OF ELEMENTARY BIOPHYSICS

Lecture 7 Pumping & Popula3on Inversion*

SPECTROPHOTOMETERS. Visible and UV-Visible

5.33 Lecture Notes: Introduction to Spectroscopy

Chemistry Instrumental Analysis Lecture 18. Chem 4631

CEE 772: Instrumental Methods in Environmental Analysis

DEPARTMENT OF CHEMISTRY UNIVERSITY OF SWAZILAND

Lecture 3: Light absorbance

GTEK Laboratory Atomic Absorption Spectrometer AAS6000 Brochure

MOLECULAR AND ATOMIC SPECTROSCOPY

Chapter 4. Spectroscopy. Dr. Tariq Al-Abdullah

UNIT I COLORIMETER AND SPECTROPHOTOMETERS PART A

Course: M.Sc (Chemistry) Analytical Chemistry Unit: III

C101-E111. Talk Letter. Vol.2 February 2009

Stray Light Rejection in Array Spectrometers

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

UV-Visible Absorption Analysis of a Two Component System

CHEM Outline (Part 15) - Luminescence 2013

ADVANCED ANALYTICAL LAB TECH (Lecture) CHM

Chapter 18. Fundamentals of Spectrophotometry. Properties of Light

PHYSICS nd TERM Outline Notes (continued)

If you like us, please share us on social media. The latest UCD Hyperlibrary newsletter is now complete, check it out.

Visible and Ultraviolet Molecular Spectroscopy

Wavelength Frequency Measurements

n ( λ ) is observed. Further, the bandgap of the ZnTe semiconductor is

UNIT 2 UV-VISIBLE SPECTROMETRY

2101 Atomic Spectroscopy

Spectrophotometry. Dr. Shareef SHAIK ASST. PROFESSOR Pharmacology

AS 101: Day Lab #2 Summer Spectroscopy

Optical Spectrometers

Transcription:

INDICATE THE EXCITED AND GROUND SINGLET AND TRIPLET STATES. INDICATE THE FOLLOWING TRANSITIONS: ABSORPTION, FLUORESCENCE, PHOSPHORESCENCE, NONRADIATIVE DECAY, INTERNAL CONVERSION AND INTERSYSTEM CROSSING. LABEL THE TRANSITIONS PROBED BY AT LEAST 4 TYPES OF SPECTROSCOPY STUDIED IN CHEM 314. JABLONSKI DIAGRAM 1

ATOMIC SPECTROSCOPY Absorp<on lines broadened by: - Uncertainty Effect - Doppler broadening - Pressure broadening Source spectrum Effec<ve bandwidth: ~0.001nm Sample Absorp0on Effec<ve bandwidth: 0.002-0.005 nm Signal at detector Smaller due to absorp<on in flame and mono throughput LEARNING CHECK 1. How are atomic and molecular spectroscopy different? 2. Diagram an Atomic Absorp0on Spectrophotometer 3. Diagram and explain how a Hollow Cathode Lamp works. 2

ATOMIC VS MOLECULAR SPECTROSCOPY 2.0 Absorbance (arb.) 1.5 1.0 0.5 0.0 300 400 500 600 700 800 wavelength (nm) FLAME ATOMIC ABSORPTION SCHEMATIC Ebert monochromator 3

ATOMIC EMISSION SPECTROSCOPY Excited state popula<on ATOMIC FLUORESCENCE SPECTROSCOPY 4

HOLLOW CATHODE LAMP (HCL) MOLECULAR SPECTROSCOPY CH 13-15 CHEM 314 5

OBJECTIVES Differen<ate between atomic and molecular spec. Iden<fy, diagram, and describe how the following instrument components func<on. Also know why these components are used. Sources: Xe arc, Deuterium arc, tungsten filament, LED Sample cuve/es: plas<c, glass, quartz Label, diagram, describe each of the following instruments: Single beam UV-Vis single element detector Single beam UV-Vis mul<-element detector Double beam UV-Vis in <me and space Fluorimeter BEER S LAW: THE RELATIONSHIP BETWEEN CONCENTRATION AND ABSORBANCE Absorbance (arb) 1.0 0.8 0.6 0.4 0.2 A=1.9 [Kool-aid] r 2 =0.97 ε molar absorb<vity 0.0 0.0 0.1 0.2 0.3 0.4 0.5 [Kool-aid] y=mx + b A=ε b [Kool-aid] b= path length 6

SOURCES OF NONLINEARITY OF BEER S LAW 1. Solu<on factors 2. Non-monochroma<c light 3. Not analyzing at l max 4. Stray light 5. Mismatched cuveles 6. Instrument noise Absorbance (arb) 3.0 2.5 2.0 1.5 1.0 0.5 0.0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 [Kool-aid] BUILDING A SPECTROSCOPIC INSTRUMENT Components 1. Stable radia<on source 2. Wavelength isola<on- monochromator 3. Transparent sample holder/ op<cs 4. Detector- PMT, photodiode, PDA 5. Signal processing 7

BUILDING A SPECTROSCOPIC INSTRUMENT Components 1. Stable radia<on source deuterium arc lamp, Tungsten filament, LED, Xe arc lamp 2. Wavelength isola<on- monochromator 3. Transparent sample holder/ op<cs Quartz, glass, plas<c 4. Detector- PMT, photodiode, PDA 5. Signal processing SOURCES Con<nuum sources with constant output as a func<on of wavelength required for molecular spectroscopy 8

BLACKBODY RADIATION Wein s Displacement Law λ max = max output λ T= temp (K) L= luminosity A= surface area α=constant hlps://docs.kde.org/stable/en/kdeedu/kstars/ai-blackbody.html TUNGSTEN FILAMENT 100 um Output spectrum at 2870 K 9

DEUTERIUM ARC XE ARC Range 200-1000 nm, peak 500 nm www.wikipedia.com hlp://zeiss-campus.magnet.fsu.edu/ar<cles/lightsources/images/ 10

LIGHT EMITTING DIODE Light emiing diode (LED) GaAlAs λ max =900 nm GaAsP λ max =650 nm GaP λ max =550 nm GaN λ max =465 nm InGaN λ max =450 nm White LED InGaN diode plus phosphor Range: 400-800 nm www.greenprophet.com hlps://lasermom.files.wordpress.com/2012/04/ledspectrum.png SEMICONDUCTORS Band gap (Eg)- Energy of gap between HOMO and LUMO HOMO- highest occupied molecular orbital LUMO- lowest unoccupied molecular orbital 11

PN JUNCTIONS Light emiing diode (LED) GaAlAs λ max =900 nm GaAsP λ max =650 nm GaP λ max =550 nm GaN λ max =465 nm InGaN λ max =450 nm White LED InGaN diode plus phosphor Range: 400-800 nm LED VS SILICON PHOTODIODE LED- Source Photodiode- Detector 12

WAVELENGTH SELECTION MONOCHROMATORS 1. Entrance slit- provides rectangular op<cal image 2. Collima<ng lens or mirror- makes light beams parallel 3. Dispersive element- disperses light into component wavelengths 4. Focusing element- reforms rectangular op<cal image focused on focal plane 5. Exit slit- on focal plane, selects desired bandwidth 13

OPTICS AND SAMPLE HOLDERS Absorbance 4 3 2 Quartz Plas<c 1 0 190 490 790 1090 Wavelength (nm) DETECTORS Vacuum phototube Photomul0plier tube (PMT) Silicon photodiode Photodiode array (PDA) 14

MOLECULAR SPECTROSCOPIC INSTRUMENTS UV-Vis Spectrophotometer single beam double beam mul<channel Fluorimeter SINGLE BEAM UV-VIS PHOTODIODE ARRAY UV-VIS 15

DOUBLE BEAM UV-VIS Double beam in space Double beam in <me FLUORIMETER scan mono ex mono em Excita<on scan fixed Emission fixed scan 16

REVIEW WHAT KIND OF INSTRUMENT IS PICTURED? HOW DO YOU KNOW? Ebert monochromator 17

WHAT KIND OF INSTRUMENT IS PICTURED? HOW DO YOU KNOW? WHAT KIND OF INSTRUMENT IS PICTURED? HOW DO YOU KNOW? 18

WHAT KIND OF INSTRUMENT IS PICTURED? HOW DO YOU KNOW? WHAT KIND OF INSTRUMENT IS PICTURED? HOW DO YOU KNOW? Excited state popula<on 19

WHAT KIND OF INSTRUMENT IS PICTURED? HOW DO YOU KNOW? WHAT KIND OF INSTRUMENT IS PICTURED? HOW DO YOU KNOW? 20

WHAT KIND OF INSTRUMENT IS PICTURED? HOW DO YOU KNOW? WHAT KIND OF INSTRUMENT IS PICTURED? HOW DO YOU KNOW? 21

WHAT KIND OF INSTRUMENT IS PICTURED? HOW DO YOU KNOW? BEER S LAW DERIVTATION 22

A SIMPLE ABSORPTION EXPERIMENT Beer s Law T= transmission P 0 = incident power P= transmiled power A= absorbance ε= molar absorp<vity b= path length C= analyte concentra<on DERIVATION OF BEER S LAW T= transmission P 0 = incident power P= transmiled power A= absorbance ε= molar absorp<vity b= path length C= analyte concentra<on 23

WRITING A PROCEDURE 1. Descrip<ve Title 2. Purpose 3. Background 4. Safety- print MSDS 5. Sample prepara0on 6. Instrument parameters 7. Data tables- in lab notebook 8. Data analysis 9. References 10. What do you need? 11. Appendices CONTRIBUTING RESOURCES TO WEBSITE (5 PTS EA) 5 pts each- up to 20 pts extra credit Resources 1. Descrip0ve 0tle- What have you found? books, ebooks, websites, anything 2. Source- Where to find the resource (cita<on or web link) 3. Content- Describe what is available (2-3 sentences) 4. Reliability and Usefulness- your opinion about resource reliability and helpfulness 5. Who s Contribu0ng? Your name or pseudonym Contribu0ons are only accepted before the applicable report is due Submit via email 24

LOOKING AHEAD Monday (Feb 8)- Molecular Spectroscopy (Ch 13-15), Wri0ng Procedures Tuesday/Thursday (Feb 9, 11)- Experiment 1 Metals Due Thursday: Annotated Figures 1, Experiment 1 Monday (Feb 15)- Vibra0onal Spectroscopy Due: Project Overview Tuesday/Thursday (Feb 16,18)- Experiment 2- Plas0cs 25

WHAT KIND OF UV-VIS INSTRUMENT IS PICTURED? HOW DO YOU KNOW? WHAT KIND OF UV-VIS INSTRUMENT IS PICTURED? HOW DO YOU KNOW? 26