Validation of TNCO, TSNAs, and PAHs

Similar documents
TSNAs in Tobacco Filler and Cigarette Smoke

Technical Report. Determination of Nitrite and Nitrate in Smokeless Tobacco Products by Ion Chromatography and Continuous Flow Analysis

Validation of analytical methods. Adrian Covaci Toxicological Center, University of Antwerp

British American Tobacco Group Research & Development. Method - Determination of phenols in mainstream cigarette smoke

Method - Determination of aromatic amines in mainstream cigarette smoke

CORESTA Recommended Method No. 86

CORESTA Recommended Method No. 83

serve the goal of analytical lmethod Its data reveals the quality, reliability and consistency of

Chapter 4: Verification of compendial methods

CCME Reference Method for the Canada-Wide Standard for Petroleum Hydrocarbons (PHC) in Soil - Tier 1 Method

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Schedule. Draft Section of Lab Report Monday 6pm (Jan 27) Summary of Paper 2 Monday 2pm (Feb 3)

OF ANALYSIS FOR DETERMINATION OF PESTICIDES RESIDUES IN FOOD (CX/PR 15/47/10) European Union Competence European Union Vote

Method Validation and Accreditation

Traceability, validation and measurement uncertainty 3 pillars for quality of measurement results. David MILDE

VAM Project Development and Harmonisation of Measurement Uncertainty Principles

Work plan & Methodology: HPLC Method Development

ASEAN GUIDELINES FOR VALIDATION OF ANALYTICAL PROCEDURES

Validation Report Determination of isoprothiolane residues in rice by GC-MS/MS (QuEChERS method)

Certified Reference Material - Certificate of Analysis

Validation of an online, real time, soft photon ionisation (SPI) time of flight mass spectrometer for mainstream tobacco smoke analysis

Method Validation. Role of Validation. Two levels. Flow of method validation. Method selection

Certificate of Analysis

GUIDELINES ON PERFORMANCE CRITERIA FOR METHODS OF ANALYSIS FOR THE DETERMINATION OF PESTICIDE RESIDUES IN FOOD AND FEED CXG Adopted in 2017.

Certified Reference Material - Certificate of Analysis Methylone, Primary Standard

Analytical Performance & Method. Validation

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

The Role of and the Place of Method Validation in Drug Analysis Using Electroanalytical Techniques

3.1.1 The method can detect, identify, and potentially measure the amount of (quantify) an analyte(s):

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

Appendix II- Bioanalytical Method Development and Validation

Certified Reference Material - Certificate of Analysis

Copyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Validation Report 18

NATIONAL ASSOCIATION OF TESTING AUTHORITIES (NATA) REQUIREMENTS FOR ACCREDITATION OF ICP-MS TECHNIQUES

Certificate of Analysis

BIOANALYTICAL METHOD VALIDATION M10

DETERMINATION OF NINE VOLATILE NITROSAMINES AND HYDROXY-NITROSAMINES IN CIGARETTE FILLER AND MAINSTREAM TOBACCO SMOKE

Pesticide Standards. Sadat Nawaz. Pesticides Residues Analyst CSL, York, UK

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution

Certificate of Analysis

Certificate of Analysis

Certificate of Analysis

Part IVB Quality Assurance/Validation of Analytical Methods

British American Tobacco Group Research & Development. Method - Determination of ammonia in mainstream smoke

What is measurement uncertainty?

Analytical Method Validation: An Updated Review

INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE

Xinyu LIU, Peter JOZA, Andrew MASTERS, Bill RICKERT

QSM 5.1 FAQs. For a test with a recommended maximum holding time measured in hours, the holding time shall be tracked by the hour.

Rosemary extract liquid

Certificate of Analysis

APPENDIX G EVALUATION OF MEASUREMENT UNCERTAINTY

Precision estimated by series of analysis ISO and Approach Duplicate Approach

Smoke Analytes Sub-Group (SMA) Report 2018

The Uncertainty of Reference Standards

How to develop an ATP.... and verify it has been met. Melissa Hanna-Brown Analytical R & D; Pfizer Global R+D, Sandwich UK.

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Analytical Strategy: HS 2014 Rafael Hodel, Stefanie Jucker. Quality Control: Quantitative Nuclear Magnetic Resonance

ELISA QUALITY ASSURANCE Analytical Phase

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Examples of Method Validation Studies Conducted in Different Economies

Certificate of Analysis

A basic introduction to reference materials. POPs Strategy

Technical Procedure for Blood Cannabinoid Liquid-Liquid Extraction (BCLLE) for Analysis by LC-MS/MS

VALIDATION OF ANALYTICAL METHODS. Presented by Dr. A. Suneetha Dept. of Pharm. Analysis Hindu College of Pharmacy

The Role of Proficiency Tests in the Estimation of Measurement Uncertainty of PCDD/PCDF and PCB Determination by Isotope Dilution Methods

Practical Statistics for the Analytical Scientist Table of Contents

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Draft Guideline on Bioanalytical Method Validation in. Pharmaceutical Development. (15 April 2013, MHLW, Japan)

Journal of Pharmaceutical and Biomedical Analysis Letters. Analysis Letters

Validation of an Analytical Method

ICH guideline M10 on bioanalytical method validation

The Theory of HPLC. Quantitative and Qualitative HPLC

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

SWGDRUG GLOSSARY. Independent science-based organization that has the authority to grant

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

ENVIRONMENTAL LABORATORY SECTOR VOLUME 1 MANAGEMENT AND TECHNICAL REQUIREMENTS FOR LABORATORIES PERFORMING ENVIRONMENTAL ANALYSIS

Pharmacopeial Forum Vol. 36(1) [Jan. Feb. 2010] 1

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Test Method: CPSC-CH-E

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

CORESTA Guide N 5 Technical Guide for Pesticide Residues Analysis on Tobacco and Tobacco Products

A Laboratory Guide to Method Validation, (Eurachem).

International Journal of Pharmacy and Pharmaceutical Sciences ISSN Vol 2, Suppl 3, 2010

APPENDIX G ESTIMATION OF UNCERTAINTY OF MEASUREMENT

GUIDELINES ON THE USE OF MASS SPECTROMETRY (MS) FOR IDENTIFICATION, CONFIRMATION AND QUANTITATIVE DETERMINATION OF RESIDUES CAC/GL

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

REVIEW. Comparison of various international guidelines for analytical method validation

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

METHOD 3600B CLEANUP

Limit of Detection and Its Establishment in Analytical Chemistry

2.1 2,3 Dichloro Benzoyl Cyanide (2,3 DCBC) and survey of. manufactured commonly for the bulk drug industry, few references were

CHAPTER - IV. Acharya Nagarjuna University, Guntur 105

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Polycyclic Aromatic Hydrocarbons in Water by GC/MS PBM

Multi-residue analysis of pesticides by GC-HRMS

Transcription:

Validation of TNCO, TSNAs, and PAHs Chris Wright British American Tobacco Group R&D UK US FDA Center for Tobacco Products Scientific Workshop 30-31 July 2013 1

General Method Testing for TNCO, TSNAs and PAHs A. Discuss the solution stability for prepared solutions and procedures to ensure their integrity. TNCO Calibration solutions are demonstrably stable for 3 months when stored under refrigeration. Calibration graphs are compared for consistency of slope and intercept. Extraction solutions are demonstrably stable for 3 weeks but are prepared weekly. PAHs Native and labelled PAHs are stable indefinitely (stability >3 years at -20 C & dark) Audit trail (by mass) to assess solvent evaporation during storage. Calibrations are compared to assess stability over time. TSNAs Native and labelled TSNA standard solutions are demonstrably stable for 12 months under refrigeration, but are replaced more frequently due to volume of use. Replacement standards are analysed to assess isotopic purity (e.g. possible presence of native TSNAs or di-deuterated analogues). Calibrations are compared to assess stability over time. Standards are obtained with appropriate certification and traceability from ISO Guide 34 suppliers (e.g. LGC standards) where practicable 2

General Method Testing for TNCO, TSNAs and PAHs B. Describe the typical storage conditions and shelf life (i.e., expiration dates) for tobacco product standards and samples. Tobacco product standards 3R4F cigarettes and tobacco are stored and handled in accordance with storage information provided by the University of Kentucky. CORESTA Smokeless Tobacco Reference Products are stored and handled in accordance with information provided by the North Carolina State University. CORESTA Monitor products are stored and handled in accordance with ISO 16055. For CORESTA CM7, practical experience from previous monitor test pieces has shown the smoke yields to be stable for at least 4 years under the condition that the test pieces are stored unopened and below +4 C. Samples Test samples are stored and conditioned in accordance with ISO 3402. Shelf life is normally 12 months from manufacture for unopened cartons stored under appropriate conditions, can be extended by frozen storage and is reduced by storage at increased temperature / humidity. 3

General Method Testing for TNCO, TSNAs and PAHs C. Describe the standard, reference, or known sample solutions used as blanks or for quality control (QC), working, and check standards when testing TNCO, TSNAs, and PAHs. TNCO Standards Nicotine ERM AC802b (LGC Standards), for calibration and calibration check, certified purity 99.7 mass% Blanks Conditioned 44mm Cambridge Filter Pad, extracted as for samples QC 3R4F cigarette, internal control product (RAL1) PAHs Standards PAH-CVS-A, PAH-ISS-A & PAH-LCS-A, ex Wellington Laboratories Blanks Conditioned 92mm Cambridge Filter Pad, extracted as for samples QC 3R4F cigarette, internal control product (RAL1) TSNAs Standards Kinesis S-163406 (IS 40-80µg/ml); LGC CUS-12395 (native TSNAs10-20 µg/ml) Blanks - Conditioned 44mm Cambridge Filter Pad, extracted as for samples QC 3R4F cigarette, internal control product (RAL1) 4

General Method Testing for TNCO, TSNAs and PAHs D. Discuss the system suitability and acceptance criteria for each test method. The discussion may include calibration, QC, working, bracketing, and verification standards, confirmation ion ratio for mass spectrometry, chromatographic parameters (i.e., retention times, tailing factor, or peak resolution), injector precision, and blanks. TNCO System suitability - as ISO 3308:2012, ISO 4387:2000, ISO 10315:2013, ISO 10362-1:1999; Environmental conditions; smoke machine calibration; balance calibration checks Nicotine/water peak tail factor and GC calibration (slope, intercept, R 2 ) PAHs System - as ISO 22634:2008; calibration (slope, intercept, R 2 ), chromatographic separation (D 12 -benzo(b)fluoranthene/d 12 -benzo(k)fluoranthene), signal/noise for lowest native calibrants TSNAs System calibration (slope, intercept, R 2 ), chromatographic separation (D 4 -NAB/D 4 - NAT), signal/noise for lowest native calibrants For all methods, data acceptance criteria blank value < limit; calibration check within specification; smoking QC results (puff number, TPM, nicotine, water, CO) within control limits, calibration check acceptable; QC results within limits. For TSNAs and PAHs, inspection of RT for native substance relative to IS and isotopic abundance / MRM response ratios. 5

General Method Testing for TNCO, TSNAs and PAHs E. Discuss the critical system suitability parameters that are critical when testing TNCO, TSNAs, and PAHs. Critical system suitability parameters 1. Demonstration of chromatographic selectivity peak separation; peak purity 2. Demonstration of adequate detectability - signal/noise ratio; impact of recovery, artefacts, suppression 3. Stability of calibration - drift check throughout analytical sequence; - short and long-term repeatability of calibration 4. Minimisation of blank contribution - materials specification; washing / conditioning of media; blank checks 5. Precision of analysis - batch to batch and over time; between analysts and instruments; Shewhart charts are used to monitor precision over time 6

General Method Testing for TNCO, TSNAs and PAHs F. Discuss the major sources of method variability, e.g., include sources from the smoking machine or regimen, sample preparation, separation, and detection of different tobacco product types and strengths. For tobacco filler and STPs, sample homogeneity and extraction efficiency require attention to avoid impact on quality of results. Matrix artefacts can bias results for substances that do not have an exact match IS. TPM delivery differs between products but is stable for individual products. For TPM, cleanup of the extract (PAHs, TSNAs) significantly reduces the effect of matrix artefacts on analysis but can reduce recoveries. Evaporative and adsorptive losses should be minimised during sample workup to avoid effects on LoQ, but are corrected for by SID. Naphthalene is not completely retained in TPM and may be further lost during sample handling. 7

General Method Testing for TNCO, TSNAs and PAHs G. Discuss specific method challenges and limitations when testing NNN and NNK. Matrix suppression is greater for NNN and NNK than NAT and NAB Clean up step in the method would be beneficial Poor peak shape is obtained for NNN when filler is extracted with aqueous buffer 8

Validation or Method Performance A. Discuss the specific details when evaluating each validation parameter. B. Discuss how each criterion is determined for each validation parameter. In accordance with ICH Q2B Methodology, IUPAC Harmonized guidelines for single-laboratory validation of methods of analysis and Commission Decision 2002/657/EC. Linearity of response dynamic range, correlation coefficient, residuals; Calibration assessment matrix (standard addition) vs solvent; Extraction efficiency incurred residue from matrix; compare techniques (e.g. shake, macerate, ASE) and solvents; Recovery of native and internal standard each stage of method, whole method; Specificity chromatographic peak purity (GC/HRTOF or LC/HRTOF) informs optimisation of chromatography and matrix reduction; Quantification limit lowest concentration in sample eliciting RSD < 20%; Accuracy (trueness) use certified reference material where available, otherwise a reference product or a proficiency sample; Repeatability vary analyst, instrument, batch/lot of calibrants, matrix type, incurred or fortified level, time (days/weeks), consumables (e.g. column) 9

Validation or Method Performance C. Describe the steps taken when validation parameter criteria are not met. C. Review raw data and procedures followed. Identify root cause of failure to meet criterion. Evaluate options for technical improvement, e.g. additional calibration point, include IS, introduce clean-up step. Implement technical improvement and evaluate method performance. If no improvement achieved, evaluate method scope and purpose. D. Discuss validation parameters that are performed with reference tobacco products or standards. D. The following parameters are investigated using reference tobacco products linearity of response; calibration; extraction efficiency; recovery; specificity; quantification limit; repeatability / intermediate precision Additionally, parameters investigated using reference and commercial tobacco products are linearity of response; calibration; extraction efficiency; specificity; quantification limit; intermediate precision 10

Validation or Method Performance E. Discuss the types and strengths of tobacco product samples used during validation and method development. Tobacco filler and smokeless tobacco products - CORESTA STRPs; Swedish-style snus, US-style moist snuff, US-style dry snuff & loose leaf tobacco - University of Kentucky Reference Cigarettes; 3R4F blend - Commercial products (e.g. chewing tobacco, other blends) Cigarettes - University of Kentucky Reference Cigarettes; 3R4F - Products tested comply with the Tobacco Products Directive (2001/37/EC) [10mg tar, 1mg nicotine, 10mg CO maximum], therefore high yield monitor products (e.g. CM7) are used only for research purposes - Commercial products also used as internal control samples, generally <7mg tar. 11

Validation or Method Performance F. Discuss the process taken to revalidate a test method when changes to the method (i.e., solvent, extraction method, or column) are made. Review of performance parameters that could be affected - e.g. for column change, selectivity, peak shape, impact of matrix artefacts Design of experiments to evaluate impact of change - re-assess the performance parameter, compare to original method performance if within specification, e.g. no increase in intermediate precision. G. Discuss the validation process when using a rotary and linear smoking machine with a nonintense and intense smoking regimen. For TNCO determination, linear smoke machines are used. TSNA analysis utilises linear smoke machines. PAH analysis utilises rotary smoke machines. Validation includes ISO and Canadian intense regimes.

Validation or Method Performance H. Describe the robustness or ruggedness tests that are conducted for extraction efficiency, solution stability, and small changes in instrument parameters. Extraction efficiency - Comparison of solvents with reference to product and analyte chemistry, peer published methods and related matrices (e.g. food, environmental) - Comparison with peer reference methods, e.g. Soxhlet extraction, ASE or multiple partitioning extraction Solution stability - Comparison of concentration between solutions stored at room temperature/daylight; room temperature dark; 4 C dark; -20 C dark - All comparisons against freshly prepared control solution Instrument parameters - Intermediate precision requires >1 analyst, >1 instrument, which usually covers small instrument variations: - Also includes performance close to limits of system suitability 13

Validation or Method Performance Concluding comments Fitness for purpose criteria should include within- and between laboratory precision. For example, target Reproducibility RSD R can be calculated from the Horwitz function. PRSDR (%) = 2 C -0.1505 Reproduced from AMC technical Brief 17, Royal Society of Chemistry 2004. Table 6. Comparison of published and predicted reproducibility for measurement of tobacco-specific N-nitrosamines in mainstream cigarette smoke. Smoking Tobacco-specific N-nitrosamine conditions NNN NAT NAB NNK ISO High Low High Low High Low High Low Mean, µg/cig 277 9.6 145 11 20 1.5 122 3.3 R 70 5.8 74 6.2 9 0.9 41 2.1 RSD R, % 25.3 60.4 51 56.4 45 60 33.6 63.6 Mass fraction 2.77 10 07 9.6 10 09 1.45 10 07 1.1 10 08 2 10 08 1.5 10 09 1.22 10 07 3.3 10 09 PRSD R, % 19.4 32.2 21.4 31.5 28.8 42.6 22 37.8 HorRat 1.3 1.9 2.4 1.8 1.6 1.4 1.5 1.7 Intense Mean, µg/cig 603 34.9 322 39.4 42.9 5.5 297 12.1 R 225 28.6 214 25.2 21.4 6.2 144 9.3 RSD R, % 37.3 81.9 66.5 64 49.9 112.7 48.5 76.9 Mass 6.03 10 07 3.49 10 08 3.22 10 07 3.94 10 08 4.29 10 08 5.5 10 09 2.97 10 07 1.21 10 08 fraction PRSD R, % 17.3 26.5 19 26 25.7 35 19.2 31.1 HorRat 2.2 3.1 3.5 2.5 1.9 3.2 2.5 2.5 Concentration data from CORESTA Recommended Method 75, Determination of TSNAs in mainstream smoke by LC-MS-MS from Wright 2013 in preparation 14