EXPERIMENT 1. Object: Measurement of ph of Water THEORY

Similar documents
PRACTICAL 3 ph AND BUFFERS

Buffer Preparation. Learning Objectives:

Environmental Engineering Laboratory

Combination ph, ORP, T Electrode with Transmitter

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

EXPERIMENT 11 Acids, Bases, and ph

EXPT. 4 DETERMINATION OF pka OF ORTHOPHOSPHORIC ACID

What is ph? Power of Hydrogen

GETTING THE END POINT TO APPROXIMATE. Two hours

Downloaded from

Ch07. Exploring Acid Base Reactions. Measuring acidity. version 1.5. Nick DeMello, PhD

20 ACIDS AND BASES Standard Curriculum

INTRODUCTION TO ACIDS, BASES AND TITRATION

Acids and Bases. How does ph affect biological solutions? Introduction. Prelab Preparation Review Section 2.3 on acids and bases in your textbook.

EXPERIMENT 6. Properties of Buffers INTRODUCTION

Chapter 9. Volumetric Analysis

CHLORINE THEORY & MEASUREMENT

Lesson Five: Acids, Bases, ph, and Buffers

LCS Laboratory Inc. 700 Collip Circle, Unit 218, London ON, N6G 4X8, (519) ,

This lab will be conducted in groups but the lab report must be completed and submitted individually.

Standard Methods for the Examination of Water and Wastewater

Buffers, Electrochemistry. Jan Pláteník & Tomáš Navrátil 2010/2011

11. Introduction to Acids, Bases, ph, and Buffers

Total, active and effective alkali

Application Note #97 Alkalinity and Hardness by Potentiometric Titration Using TRIS Buffer

Experiment 8 and 9 Weak Acids and Bases: Exploring the Nature of Buffers

Determination of the K a of a Weak Acid and the K b of a Weak Base from ph Measurements

Chemistry Determination of Mixed Acids

Experiment 7 Buffer Capacity & Buffer Preparation

NCERT. [H O] Since water is in large excess, its concentration can be assumed to be constant and combining it with K provides a new constant K w

Lab #3 ph and Buffers

Chapter 9: Acids, Bases, and Salts

( 1 ) Concept of acid / base

Potentiometric measurement of ph

Determination of the Equivalent Weight and Ionization Constant of a Weak Acid

4. Acid Base Equilibria

DPD Test N Tube Method *

First week Experiment No.1 / /2013. Spectrophotometry. 1. Determination of copper via ammine complex formation using standard series method

Identification Of The Common Laboratory Glassware, Pipettes And Equipment. BCH 312 [Practical]

OCR (A) Chemistry A-level Topic Acids, Bases and Buffers

Practical 1P3 Electrode Potentials

1.12 Acid Base Equilibria

Analysis of cations and anions by Ion- Selective Electrodes (ISEs)

EXPERIMENT 9 BUFFERS PURPOSE: To understand the properties of a buffer solution

12. Acid Base Equilibria

not to be republished NCERT YOU are already aware that a substance is analysed to establish its qualitative TITRIMETRIC ANALYSIS UNIT-6

CHEMISTRY LABORATORY - I

Using Conductivity to Find an Equivalence Point

mohd faisol mansor/chemistry form 4/chapter 7 CHAPTER 7 ACIDS AND BASES HCl (g) H 2 O H + (aq) + Cl - (aq) NaOH(s) H 2 O Na + (aq) + OH - (aq)

Experiment Nein! Acid Base. Equilibria. Last Week. This week. CH 204 Fall 2008 Dr. Brian Anderson

Alkalinity. LabQuest INTRODUCTION

EXPERIMENT. Estimate the strength of given sodium carbonate solution by titrating it against HCl solution using methyl orange as indicator.

Form 4 Chapter 7: Acid and Bases

#13 Electrochemical Cells

General Medicine 2016/17

AQA Chemistry A-Level : Acids and Bases

Name Date Class. Chapter 19 Acids, Bases, and Salts EXPERIMENT. ESTIMATION OF ph PURPOSE BACKGROUND MATERIALS (PER PAIR)

Introduction. Concepts Kinetics Order of reaction Reaction rate Colorimetry. Background

Science 30 Unit B Chemistry and the Environment

Volumetric analysis involving acids and alkalis

Lab- Properties of Acids and Bases. Name. PSI Chemistry

Rapid RH Portable ph Meter. User's Manual

1.8K: Define a buffer as relatively large amounts of a weak acid or base and its conjugate in equilibrium that maintain a relatively constant ph when

Chapter 14. Principles of Neutralization Titrations

ACID BASE TITRATION Aim: Determination of Alkalinity of water

Final Concentration 0 excess 0.1 M 0.1 M

Titration with an Acid and a Base

Name: CE 310 Sample First Exam Fall 20xx Closed Book Portion B.A. DeVantier

STANDARD OPERATING PROCEDURE

Volumetric analysis selected tasks

Chapter 3 Electrochemical methods of Analysis-Potentiometry

aa + bb cc + dd Equation 1

EXPT. 8 IODOMETRIC DETERMINATION OF AVAILABLE CHLORINE IN A SAMPLE OF BLEACHING POWDER

Prince George s Community College PL 2: CHARACTERIZATION OF A MONOPROTIC WEAK ACID BY POTENTIOMETRIC TITRATION

chemrevise.org 20/08/2013 Titration curves N Goalby Chemrevise.org 25 cm 3 of base

MEASUREMENT OF ph: INTRODUCTION TO BUFFER AND BASICS OF ph Meter

ACIDS, BASES AND SALTS

To measure ph s in a variety of solutions and mixtures and to account for the results obtained.

Acids, Bases, Salts, and Buffers

ph / Temperature Meter for Cheese with Application Specific Probe

Acid Soil. Soil Acidity and ph

Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste

CHEMISTRY HIGHER LEVEL

E. Incorrect. Look carefully there is a statement that is true about weak acid dissociation.

ACID-BASE TITRATION AND PH

Exercise 4-3. Titration of Weak Acids EXERCISE OBJECTIVE DISCUSSION OUTLINE. The 5% rule DISCUSSION

H + [ ] [ ] H + NH 3 NH 4. = poh + log HB +

Properties of Acids and Bases

Exercise 2-4. Titration of a Buffer Solution EXERCISE OBJECTIVES

ION DIFFUSION OBJECTIVES

By: Michael Wild, Matt Huber, Jasmine Gilbert and Dr. Faith Yarberry

ACID-BASE TITRATION (MICROSCALE)

5.1.3 Acids, Bases and Buffers

Microscale Acid-Base Titration

Guide to ph Analysis.

# 12 ph-titration of Strong Acids with Strong Bases

Stoichiometry Lab Final this is not a proper title, so change it to be more descriptive

C4S: ACID BASE EQUILIBRIUM Lesson 3

ph METERS, HYDROLYSIS, AND BUFFER CAPACITY

NANDI CENTRAL DISTRICT JOINT MOCK 2013

Transcription:

EXPERIMENT 1 Object: Measurement of ph of Water THEORY ph as defined by Sorenson is negative logarithm of hydrogen ion concentration. At a given temperature the acidic or basic character of a solution is indicated by ph or hydrogen ion activity. Actually the alkalinity and acidity of the water is something different. The alkalinity and acidity are the acid and base neutralizing capacities of water and are usually expressed as milligrams of CaCO 3 per litre. The ph is important in every phase of environmental engineering practice. In water treatment process it is a factor that is to be considered in chemical coagulation, disinfection, water softening and corrosion control. Coagulation means the mixing of alum like chemicals to make flocks and to increase the settlement of colloidal particles in water purification. The efficiency of the chemical coagulant like alum depends upon the ph of water and it is most efficient in the ph range of 6.5 to 8.5. Similarly chlorine is added to water to kill the bacteria and other microorganism and this process is known as disinfection. The efficiency of chlorine is also dependent on the ph of water. So the determination and then the required adjustment of ph is a must for the efficient use of coagulant and disinfectants. The pure water dissociates to yield a concentration of hydrogen ions equal to about 10 7 mol/l. H 2 O H + + OH The amount of hydroxyl ions is equal to the hydrogen ions, so 10 7 mol of hydroxyl ion is produced simultaneously. The equilibrium equation gives {H + } {OH }/H 2 O = K As the concentration of water is so extremely large and is diminished so much little by the slight degree of ionization it may be considered as constant and the above equation can be written as

2 Environmental Engineering Lab Manual {H + } {OH } = K w For pure water at 25 o C {H + } {OH } = 10 7 10 7 = 10 14 This is known as the ion product or ionization constant for water When an acid is mixed in water it ionizes in the water and the H ion activity increases. Consequently the OH ion activity must decrease according to the ionization constant. For example if acid is added to increase the {H + } to 10 2, the {OH } must decrease to 10 12 10 2 10 12 = 10 14 Similarly if a base is added to increase the {OH } to 10 3, the {H + } decreases to 10 11. However the {H + }or the {OH } can never be reduced to zero no matter how basic or acidic the solution may be. Designating the hydrogen ion concentration in terms of molar concentration is cumbersome and to overcome this difficulty, Sorenson gave such value in terms of their negative logarithms as ph. So ph = log {H + } Or ph = log 1/ {H + } The ph scale is represented as ranging from 0 to 14 with ph 7 at 25 o C designating absolute neutrality. ph lesser than 7 is acidic and more than 7 is a basic solution. MEASUREMENT OF ph Although the hydrogen electrode is the absolute standard for the measurement of ph, due to the difficulties in its operation, the glass electrodes are more useful. They are available in a vide range, i.e. portable battery operated units suitable for field measurements to highly precise laboratory instruments. Depending upon the type of electrode ph measurements can be done for extreme test conditions. The ph measurement of semisolid substances can be done with a spear type electrode. The instruments are standardized with buffer solutions of known ph values. The ph of the buffer solution should be within 1 to 2 units of the sample whose ph is to be measured. The ph value can be determined either electrometrically or colorimetrically. The electometric is more accurate but as it requires special apparatus colorimetric methods are generally used for normal determinations of ph useful for environment engineers. (A) Electrometric Determination of ph The basic principle of electrometric ph measurement is determination of activity of hydrogen ions by potentiometric measurements using a glass electrode. Contact between the test solution and electrode is achieved by means of a liquid junction. The electromotive force is measured with a ph meter, that is high impedance voltmeter calibrated in terms of ph.

Experiment 1: Measurement of ph of Water 3 Apparatus The apparatus consists of a ph meter with glass and reference electrode with temperature compensation. The ph meter contains a glass electrode which generates a potential varying linearly with the ph of the solution in which it is immersed. A calomel or Ag/AgCl/KCl reference electrode is generally located around the glass electrode stem. Procedure (i) Calibrate the electrodes with two standard buffer solutions of ph 4.0 and 9.2 (The buffer solution is a solution offering resistance to change in ph and whose ph value is known) (ii) The temperature of sample is determined simultaneously and is entered into the meter to allow for a correction of temperature. (iii) Wash the electrodes carefully with distilled water and wipe with tissue paper. (iv) Immerse the electrodes into the sample of water (whose ph is to be determined) and wait upto one minute for steady reading. (v) The reading is observed after the indicated value becomes constant. (B) Colorimetric Method Apparatus and reagents Aquascope complete with cell and slides of standard colours Universal indicator for ph 4 to ph 11 Bromothymol blue indicator for ph 6 to ph 7.6 Procedure (i) Take four test tubes and fill them half with sample water. (ii) Add 10 drops of the universal indicator to each of the test tubes. (iii) Mix the solution in the test tubes by turning them up and down (iv) Observe the tinge of the colours developed in the test tubes and match them with the colour scale given on the indicator bottle. (v) The colour scale given on the bottle will directly give the ph value. If the ph value is between 6 and 7.6 a more accurate method is used. (i) Fill the sample of water in the aquascope upto black line mark. Put 15 drops of Bromothymol Blue indicator in the middle compartment of the cell and stir it with the stirrer. (ii) After 5 minutes observe the developed colour and match it with the colour slides available on the Aquascope. (iii) The indicated ph of the matching slide will give the ph of the sample.

4 Environmental Engineering Lab Manual Observations S. No. Sample ph with ph meter ph with Universal ph with indicator Bromothymol blue indicator 1 A 2 B 3 C 4 D Results The ph values of the given samples are as follows. A : B : C : D : Comments (i) The acceptable value of ph for potable water is 7.0 to 8.5. Water having ph below 6.5 and above 9.2 is rejectionable. (ii) Higher value of ph accelerates the scale formation in water heating apparatus and the boilers. (iii) Higher values of ph reduce the germicidal potential of Chlorine. (iv) ph value below 6.5 starts corrosion in pipes thereby releasing toxic metals like Zn. (v) In biological treatment of waste waters if the ph goes below 5 the decomposition is severely affected. There is a suitable range of 5 to 10 ph for aerobic decomposition of organic matter present in the waste waters. If the ph is beyond this range then it has to be adjusted by addition of acid or alkali. (vi) ph value is very much important for any chemical reaction as a chemical is highly effective at a particular ph. Chemical coagulation (use of Alum), disinfection (use of Chlorine), water softening and corrosion control are governed by ph adjustment. So the observed ph value of the sample indicates that......

Experiment 1: Measurement of ph of Water 5 Quiz Questions 1. ph is defined as (i) Logarithm of Hydrogen ions (ii) Negative logarithm of Hydrogen ions (iii) Hydrogen ion concentration (iv) OH ion concentration 2. ph of neutral water is (i) less than7 (ii) more than 7 (iii) 7.0 (iv) 0.o 3. For pure water at 25 C, the product of H+ and OH ions is (i) 10 7 (ii) 10 14 (iii) 10 (iv) 107 4. The acceptable value of ph of potable water is (i) 7.0 to 8.5 (ii) 6.5 to 9.5 (iii) 6 to 8.5 (iv) 6.5 to 10 5. Acidity of water means (i) ph of water in acidic range (ii) ph of water in alkaline range (iii) base neutralizing capacity of water (iv) acid neutralizing capacity of water 6. The alum is most effective as a coagulant in the ph range of (i) 6.5 to 8.5 (ii) 6 to 9.0 (iii) 6.5 to 9.5 (iv) 7.0 to 7.5

6 Environmental Engineering Lab Manual 7. For the aerobic decomposition of organic matter the ph should not go below (i) 5.0 (ii) 6.0 (iii) 7.0 (iv) 9.0 8. Following indicator is used for ph determination of water between 4 to 11 ph (i) Phenolphthalein (ii) Methyl orange (iii) Universal Indicator (iv) Bromthymol Indicator Correct Answers 1. (ii) 2. (iii) 3. (ii) 4. (i) 5. (iii) 6. (i) 7. (i) 8. (iii)