FLUKA simulations of selected topics regarding proton pencil beam scanning

Similar documents
NEUTRON H*(10) INSIDE A PROTON THERAPY FACILITY: COMPARISON BETWEEN MONTE CARLO SIMULATIONS AND WENDI-2 MEASUREMENTS

Estimating proton beam energy spread using Bragg peak measurement

Prompt gamma measurements for the verification of dose deposition in proton therapy. Contents. Two Proton Beam Facilities for Therapy and Research

A Monte Carlo Study of the Relationship between the Time. Structures of Prompt Gammas and in vivo Radiation Dose in.

Monte Carlo Simulation concerning Particle Therapy

THE mono-energetic hadron beam such as heavy-ions or

COMPARISON OF COMPUTER CODES APPLICABILITY IN SHIELDING DESIGN FOR HADRON THERAPY FACILITIES *

arxiv: v2 [physics.med-ph] 29 May 2015

Monte Carlo commissioning of photon beams in medical LINACS using wide-field profiles in a water phantom

Manipulation on charged particle beam for RT benefit.

Radiation protection issues in proton therapy

3 Monte Carlo tools for proton dosimetry

Modelling of a proton spot scanning system using MCNP6

Fluka advanced calculations on stopping power and multiple Coulomb scattering

Instrumentation for Verification of Dose

TITLE: Air Kerma Primary Standard: Experimental and Simulation Studies on Cs-137

Radiation Shielding of a 230 MeV Proton Cyclotron For Cancer Therapy

Towards Proton Computed Tomography

Instrumentation for Verification of Dose

Radiation safety of the Danish Center for Proton Therapy (DCPT) Lars Hjorth Præstegaard Dept. of Medical Physics, Aarhus University Hospital

Chapter V: Cavity theories

Simulations in Radiation Therapy

CHARACTERIZATION OF A RADIATION DETECTOR FOR AIRCRAFT MEASUREMENTS

Towards efficient and accurate particle transport simulation in medical applications

CHARACTERISTICS OF DEGRADED ELECTRON BEAMS PRODUCED BY NOVAC7 IORT ACCELERATOR

Secondary Radiation and Shielding Design for Particle Therapy Facilities

Secondary Neutron Dose Measurement for Proton Line Scanning Therapy

Shielding Design Considerations for Proton Therapy Facilities

Initial Studies in Proton Computed Tomography

The scanning microbeam PIXE analysis facility at NIRS

Beam Optics for a Scanned Proton Beam at Loma Linda University Medical Center

Secondary Particles Produced by Hadron Therapy

Physics of Novel Radiation Modalities Particles and Isotopes. Todd Pawlicki, Ph.D. UC San Diego

Validation of the UFS Bonner Sphere Spectrometer and Monte Carlo Methods at the CERN-EU high energy Reference Field (CERF)

Physics of Particle Beams. Hsiao-Ming Lu, Ph.D., Jay Flanz, Ph.D., Harald Paganetti, Ph.D. Massachusetts General Hospital Harvard Medical School

Optimization of hadron therapy proton beam using Monte Carlo code on GPU

Monte Carlo simulations of neutron and photon radiation fields at the PF 24 plasma focus device

Radiation Shielding. PTCOG 57 Cincinnati, USA (2018)

Ion- and proton-beams: Experience with Monte Carlo Simulation

Improvements and developments of physics models in PHITS for radiotherapy and space applications

Monte Carlo study of the potential reduction in out-of-field dose using a patient-specific aperture in pencil beam scanning proton therapy

assuming continuous slowing down approximation , full width at half maximum (FWHM), W 80 20

MONTE CARLO SIMULATION FOR EVALUATION OF DOSE DISTRIBUTION IN PROTON THERAPY *

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

ESTIMATION OF 90 SCATTERING COEFFICIENT IN THE SHIELDING CALCULATION OF DIAGNOSTIC X-RAY EQUIPMENT

8/3/2016. Chia-Ho, Hua St. Jude Children's Research Hospital. Kevin Teo The Hospital of the University of Pennsylvania

Transport under magnetic fields with the EGSnrc simulation toolkit

Calibration of the GNU and HSREM neutron survey instruments

APPLIED RADIATION PHYSICS

Kaon Identification at NA62. Institute of Physics Particle, Astroparticle, and Nuclear Physics groups Conference 2015

Radiation Protection Dosimetry (2006), Vol. 118, No. 3, pp Advance Access publication 6 October 2005

Physics 663. Particle Physics Phenomenology. April 23, Physics 663, lecture 4 1

A Measuring System with Recombination Chamber for Photoneutron Dosimetry at Medical Linear Accelerators

Calculations of Photoneutrons from Varian Clinac Accelerators and Their Transmissions in Materials*

Il picco di Bragg. G. Battistoni INFN Milano. 08/06/2015 G. Battistoni

Interaction of Particles and Matter

Indrin J. Chetty, AAPM 2006 Monte Carlo CE course

MAGNETIC FIELD EFFECTS ON THE NANOSCOPIC CLUSTER-SIZE DISTRIBUTION FOR THERAPEUTIC PROTON BEAMS

7. a XV-2 high spatial resolution lm detector (Kodak). Important parameters of these detectors are given in Table1. The ionization chambers and the di

IBA C400 Cyclotron Project for hadron therapy

Three-Dimensional Nuclear Analysis for the Final Optics System with GIMMs

Monte Carlo simulations of ripple filters designed for proton and carbon ion beams in hadrontherapy with active scanning technique

Detectors in Nuclear Physics: Monte Carlo Methods. Dr. Andrea Mairani. Lectures I-II

Evaluation of backscatter dose from internal lead shielding in clinical electron beams using EGSnrc Monte Carlo simulations

Air Kerma Primary Standard: Experimental and. Simulation Studies on Cs-137. J. Cardoso, L. Santos, C. Oliveira

Simulation of light ion transport in a water phantom using Geant4.

Outline. Physics of Charge Particle Motion. Physics of Charge Particle Motion 7/31/2014. Proton Therapy I: Basic Proton Therapy

Physics sources of noise in ring imaging Cherenkov detectors

RADIOLOGICAL IMPACT OF THE TRIGAACCELERATOR-DRIVEN EXPERIMENT (TRADE)

Neutron interactions and dosimetry. Eirik Malinen Einar Waldeland

Radiation shielding for undulator beamline in Indus-2 synchrotron radiation source

FLUKA calculations for the beam dump system of the LHC : Energy deposition in the dump core and particle spectra in the beam loss monitors

Nuclear Cross-Section Measurements at the Manuel Lujan Jr. Neutron Scattering Center

Today, I will present the first of two lectures on neutron interactions.

Light ion recoil detector

Interactions with Matter Photons, Electrons and Neutrons

Interaction theory Photons. Eirik Malinen

Neutron and/or photon response of a TLD-albedo personal dosemeter on an ISO slab phantom

Heuijin Lim, Manwoo Lee, Jungyu Yi, Sang Koo Kang, Me Young Kim, Dong Hyeok Jeong

Radiation damage calculation in PHITS

Shielding verification and neutron dose evaluation of the Mevion S250 proton therapy unit

Application of a Laser-Wakefield Driven Monochromatic Photon Source to Nuclear Resonance Fluorescence

Evaluation of Various Material Properties to Shield from Cosmic Radiation Using FLUKA Transport Code

Geant4 Monte Carlo code application in photon interaction parameter of composite materials and comparison with XCOM and experimental data

Shielding Considerations

Problem P7. Stéphanie Ménard. Dosimetry Department Fontenay-aux FRANCE IRSN QUADOS IRSN

Polycrystalline CdTe Detectors: A Luminosity Monitor for the LHC

Optimizing the 8 Li yield for the IsoDAR Neutrino Experiment

Hands on LUNA: Detector Simulations with Geant4

Measurement ofdepth-dose distribution ofprotons by an imaging plate

MCNP TRANSPORT CODE SYSTEM & DETECTOR DESIGN

Georgia Institute of Technology. Radiation Detection & Protection (Day 3)

A comparison of methods for monitoring photon beam energy constancy

Geant4 Based Space Radiation Application for Planar and Spherical Geometries

Neutron dose assessments for MATROSHKA using the HPA PADC dosemeter

Light element IBA by Elastic Recoil Detection and Nuclear Reaction Analysis R. Heller

Proton and neutron radiation facilities in the PS East hall at CERN

Interactions of Particulate Radiation with Matter. Purpose. Importance of particulate interactions

arxiv: v1 [physics.ins-det] 29 Jun 2011

IAC-08-A MONTE CARLO SIMULATIONS OF ENERGY LOSSES BY SPACE PROTONS IN THE CRATER DETECTOR

Transcription:

FLUKA simulations of selected topics regarding proton pencil beam scanning C. Bäumer, J. Farr, J. Lambert and B. Mukherjee Westdeutsches Protonentherapiezentrum Essen, Germany T. Mertens, and B. Marchand IBA Dosimetry, Schwarzenbruck/Germany

Contents Simulation techniques Lateral scattering of pencil beams Integral depth-dose distributions with pencil-beam scanning (PBS) Large-electrode MLIC/zebra Neutron radiation protection Outlook Conclusions

Simulations technique Performed on a single workstation with 4x Intel Xeon processors, 3 GHz 64bit Linux Debian Lenny (with additional packages, e.g. g77, from older Etch edition) Most recent FLUKA and FLAIR releases Use combinatorial geometry No user routines employed and HADROTHE defaults for the projects presented today No variance reduction techniques Typically a few million primaries. Suffices for problems where primaries dominate statistics Mainly use USRBIN and USRYIELD estimators, postprocessing in Matlab MCNPX 2.7 on Windows computer to cross-check some type of FLUKA simulations

Pencil Beam Scanning Source: 230 MeV cyclotron with continuous energy selection Basic measurement: completely capture static pencil beam at depth z Gantry mounted PBS nozzle spot size 3 mm sigma @ 230 MeV in air z Figures adapted from PTW catalog and T. Lomax, ESTRO 2009 Bragg Peak ionization chamber in water tank or Multi-layer ionization chamber

Understanding the problem (1) FLUKA Monte Carlo modeling performed 230 MeV 230 MeV Radial distribution (cylindr./cartes.) 5 PDF of dose ( Radial weighting )

Understanding the problem (2) Default physics settings: Hadronic interactions off: Test depth 230 MeV 230 MeV Low dose enhancement at about 15 cm 20 cm Hadronic interactions direct dose to intermediate depths

Understanding the problem (3) Used 1 cm size bins in depth direction. Limited simulation to radius of 25 cm. Maximum relative statistical error about 0.001. 230 MeV diagram shows relative dose loss, e.g. at 10-3 0.001 of the charge is not collected (i.e. geometrical collection efficiency is 0.999) typically the dose is underestimated by a few percent for realistic electrode radii

Understanding the problem (4) measure integral depth dose curves with large electrode ionization chamber and static pencil beam on central axis Shape of depth-dose distribution changes when limiting sensing radius Also see G. Sawakuchi et al., An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle, Med. Phys. 37 (2010) 4960

Understanding the problem (5) Experiment with Gafchromic EBT2 film Simulation/Computation: MCNPX 2.7 Experiment: ambiguous analysis: fit of optical density (OD) or dose in 1d or 2d give different results Note BG Highland : analytical approach by subdividing water into 0.5 cm slabs and using Gottschalks integrable form of Highlands formula (B. Gottschalk et al., Nucl. Instr. Meth. B74 (1993) 467).

Static pencil beam in water Very good match between simulation and experiment (4.1 cm radius BPC). Slight deviations: simulation underestimates the dose in plateau region for intermediate and highest energies. Magnitude of deviation is about 1% (relative to BP height) Preliminary expmtl. data!!! Simulation: I H2O = 75 ev virtual source-axis distance: 0.6 m (preliminary) assumed 5 mrad (fwhm) angular divergence of source energy dispersion tuned to fit distal fall-off of Bragg peak statistical error per depth bin typically below 1%, maximum 1.5%

MLIC/zebra (1) MLIC Electro-mechanical properties: Multi-layer ionization chamber (commercial name zebra ) 120 mm physical diameter collecting cross-section 180 layers spaced 0.8 mm apart (2 mm pitch). State-of-the-art printed circuit board material Electronic readout: two possibilities for adjustment of charge collection: bias voltage charge collection quantum (CCQ). MLIC Testing Acquire depth dose distribution with zebra detector Repeat measurements with depth scans in water phantom using the same settings

Radiological detector test PBS Nozzle Beam 180 layers Bias and signal cables 120 mm diameter electrode

MLIC/zebra (2) Geometry and cavity effects Stack of air and dense water 4.1 cm radius 6.0 cm radius Stack of air and dense water water tank MLIC/ zebra Material effects Tank with Zebra- Equivalent material Tank with Zebra- Equivalent material Compare large electrode MLIC/zebra with 4.1 cm radius Bragg Peak Chamber!!!

MLIC/zebra (3) Study possible geometry and cavity effects: Model virtual detector which is stack of air and dense water. ρ( dense H 2 O ) = 1.55 g/cm 3 E beam = 210 MeV E beam = 210 MeV Stacked structure and contiguous water volume show no difference Increasing the electrode radius from 4 cm to 6 cm increases the geometrical collection efficiency at intermediate depths

MLIC/zebra (4) Working with 180 MLIC layers in simulations is quite cumbersome Establish simple MLIC model by defining zebra-equivalent (ZEQ) material ZEQ represents average material composition in zebra detector, i.e. add elemental contributions of Duraver, Polyimide and Graphite weighted by respective masses in single layer. Calculate mass density with mass density and thickness of each component and include WEQ factor of 1.855 mm/ch ρ = 1.136 g/cm 3 Weight fraction 626.0 204.7 17.1 60.3 21.0 101.0 4.5 4.7 1.8 22.0 960.5 84.5 Element O Si B Al Mg Ca Na Ti F H C N

MLIC/zebra (5) -ZEQ

MLIC/zebra (6) Use simple stack of materials per layer Duraver = 60% polyimide + 40% E-Glass Beam direction Graphite 0.08 mm Duraver 0.76 mm Polyimide 0.36 mm Air 0.8 mm Not to scale! Colors do not match!

MLIC/zebra (7) Simulation Simulation

MLIC/zebra (8) Simulation Experiment

MLIC/zebra (9) Geometry and cavity effects Stack of air and dense water 4.1 cm radius 6.0 cm radius Stack of air and dense water water tank irrelevant + Improve beam capturing at intermediate depths MLIC/ zebra Material effects Tank with Zebra- Equivalent material Tank with Zebra- Equivalent material - Distort integral depth dose curve thru large-angle scattering + partly recover from distortion of depth dose curve

Neutron Radiation Protection (1) Number of neutrons generated in inelastic interactions per beam particle E beam (MeV) FLUKA MCNPX Def. CEM 100 0.20 0.19 0.15 160 0.51 0.45 0.38 230 1.03 0.87 0.75 See also: S. Agosteo et al., Double differential distributions and attenuation in concrete for neutrons by 100-400 MeV protons on iron and tissue targets, Nucl. Instr. Meth. B 114 (1996) 70 and J. V. Siebers et al., Shielding Calculations for 230-MeV Protons Using the LAHET Code System, Nucl. Sci. And Eng. 122 (1996) 258

Neutron Radiation Protection (2) Motivation: Neutron source term for health physics calculations Simulated Geometry: 0.5 cm radius annular beam incident on 2.5 cm radius copper cylinder (6.5 cm length) FLUKA: USRYIELD MCNPX: E4 + F4 (n/cm 2 averaged over concentric rings with 90 m < r < 91 m) Graphs clipped for low fluences such to show only data points with maximum of 5% statistical error n/p/gev/sr n/p/gev/sr

Outlook Test prototype of 6 cm radius Bragg Peak Chamber from iba dosimetry Establish framework of correction factors to scale MLIC/zebra acquired depth-dose distributions to equivalent measurements in water More elaborated source model (adapted to commissioning data) Build Linux cluster and set-up parallel computing of FLUKA jobs MC for dose verification PET (i.e. voxel geometry and activation)

Conclusions When measuring depth doses for individual pencil beams (beamlets) care must be taken due to components of dose, primarily from nuclear reactions, that extend relatively far out transverse to the beam direction. For use in a scanning system of nominal 3 mm beam size (in air/230 MeV) a new multi-element ionization detector with capture cross-section of 12 cm has been developed, tested and simulated with FLUKA. FLUKA MC simulations correctly predict trend of distortion of MLIC/zebra depth dose curve compared to water. Main requirements on FLUKA: Good condensed-history implementation of multiple Coulomb scattering Good model of inelastic interactions