National Accelerator Laboratory

Similar documents
National Accelerator Laboratory

National Accelerator Laboratory

National Accelerator Laboratory

National Accelerator Laboratory

National Accelerator Laboratory

Measurement of Properties of Electroweak Bosons with the DØ Detector

Measurements of the W Boson Mass and Trilinear Gauge Boson Couplings at the Tevatron

National Accelerator Laboratory

FERMI NATIONAL ACCELERATOR LABORATORY

Diffractive Dijet Search with Roman Pots at CDF

National Accelerator Laboratory

Physics at Hadron Colliders

Fermi National Accelerator Laboratory. Inclusive Jet Production at CDF. Anwar Ahmad Bhatti. For the CDF Collaboration

National Accelerator Laboratory

Scaling between K+ and proton production in nucleus-nucleus collisions *

14 Top Quark. Completing the Third Generation

Top production measurements using the ATLAS detector at the LHC

Electroweak Physics at the Tevatron

Precise measurements of the W mass at the Tevatron and indirect constraints on the Higgs mass. Rencontres de Moriond QCD and High Energy Interactions

Top quark pair properties in the production and decays of t t events at ATLAS

Oliver Stelzer-Chilton University of Oxford High Energy Physics Seminar Michigan State University

ust/ aphysics Division, Argonne National Laboratory, Argonne, Illinois 60439, USA

National Accelerator Laboratory

STI. ANL-HEP-CP June 10, 1997 ISOLATED PROMPT PHOTON PLUS JET PHOTOPRODUCTION AT HERA a

Events/(10 GeV/c 2 ) Average Weight. -ln L. νwt. Reconstructed Mass (GeV/c 2 ) - log(l) m t

Measurement of t-channel single top quark production in pp collisions

PoS(EPS-HEP2011)250. Search for Higgs to WW (lνlν, lνqq) with the ATLAS Detector. Jonas Strandberg

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Measurement of the mass of the W boson at DØ

Optimization of NSLS-II Blade X-ray Beam Position Monitors: from Photoemission type to Diamond Detector. P. Ilinski

National Accelerator Laboratory

W/Z Production Cross Sections and Asymmetries at ECM = 2TeV

LUMINOSITY REQUIREMENTS FOR HIGGS RESONANCE STUDIES AT THE FIRST MUON COLLIDER*

PoS(EPS-HEP2015)309. Electroweak Physics at LHCb

Direct measurement of the W boson production charge asymmetry at CDF

AC dipole based optics measurement and correction at RHIC

arxiv: v1 [hep-ex] 8 Jan 2018

YUNGSu TSAI. Stanford Linear Accelerator Center Stanford University, Stanford, California ABSTRACT

The W-mass Measurement at CDF

Measurement of the W boson mass at Tevatron

Top and Electroweak Physics at. the Tevatron

Determination of Electroweak Parameters

Modeling Laser and e-beam Generated Plasma-Plume Experiments Using LASNEX

Highlights of top quark measurements in hadronic final states at ATLAS

80.6 TEVATRON 80.5 M W. LEP/SLC (indirect) Higgs Mass (GeV/c 2 ) M top.

Hyperon Particle Physics at JHF. R. E. Mischke

FINDING THE HIGGS BOSON: A STATUS REPORT*

PoS(ICHEP2012)194. Measurements of the t t forward-backward asymmetry at CDF. Christopher Hays

PROJECT PROGRESS REPORT (03/lfi?lfibr-~/15/1998):

PoS(CKM2016)117. Recent inclusive tt cross section measurements. Aruna Kumar Nayak

VBF SM Higgs boson searches with ATLAS

Top, electroweak and recent results from CDF and combinations from the Tevatron

Direct Measurement of the W Total Decay Width at DØ. Outline

GA A23736 EFFECTS OF CROSS-SECTION SHAPE ON L MODE AND H MODE ENERGY TRANSPORT

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Precision measurements of the top quark mass and width with the DØ detector

Inclusive top pair production at Tevatron and LHC in electron/muon final states

Use of Gamma Rays from the Decay of 13.8-sec "Be to Calibrate a Germanium Gamma Ray Detector for Measurements up to 8 MeV

Si. Petersburg, FL 33711, U.S.A. bhigh Energy Physics Division, Argonne National Laboratory, Argonne, IL 60439, U.S. A. ABSTRACT

A Distributed Radiator, Heavy Ion Driven Inertial Confinement Fusion Target with Realistic, Multibeam Illumination Geometry

W mass measurement in the ATLAS experiment

Data Comparisons Y-12 West Tower Data

The ATLAS Detector at the LHC

GA A26474 SYNERGY IN TWO-FREQUENCY FAST WAVE CYCLOTRON HARMONIC ABSORPTION IN DIII-D

National Accelerator Laboratory

Summary Report: Working Group 5 on Electron Beam-Driven Plasma and Structure Based Acceleration Concepts

arxiv: v1 [hep-ex] 27 Nov 2017

EW Physics at LHC. phi= mu_4: pt=7.9 GeV, eta=-1.13, phi=0.94. Toni Baroncelli:

Top results from CMS

Abstract of paper proposed for the American Nuclear Society 1997 Winter Meeting Albuquerque, New Mexico November 16-20, 1997

arxiv: v1 [hep-ex] 18 Jul 2016

Measurement of W-boson Mass in ATLAS

QCD at CDF. Régis Lefèvre IFAE Barcelona On behalf of the CDF Collaboration

Evidence for Single Top Quark Production. Reinhard Schwienhorst

Overview of the Higgs boson property studies at the LHC

Plasma Response Control Using Advanced Feedback Techniques

ATLAS-CONF October 15, 2010

CONSTRAINTS ON THE PROTON S GLUON DENSITY FROM. High Energy Physics Division, Argonne National Laborato~, Argonne, IL6O439, USA

Results from D0: dijet angular distributions, dijet mass cross section and dijet azimuthal decorrelations

Electroweak results. Luca Lista. INFN - Napoli. LHC Physics

PoS(ICHEP2012)300. Electroweak boson production at LHCb

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Measurement of the W-mass with the ATLAS detector

National Accelerator Laboratory

arxiv: v1 [hep-ex] 16 Jan 2019

Identification of the Higgs boson produced in association with top quark pairs in proton-proton

Observation of the Top Quark

arxiv:hep-ex/ v1 8 Jun 2001

CQNl_" RESPONSE TO 100% INTERNAL QUANTUM EFFICIENCY SILICON PHOTODIODES TO LOW ENERGY ELECTRONS AND IONS

Electroweak physics at the LHC

Precision Electroweak Measurements at the Tevatron

1 GeV CW nonscaling FFAG for ADS, and magnet parameters

Standard Model Measurements at ATLAS

Invited Contribution to XXXVII th Recontres de Moriond Electroweak Conference. March 2002, Les Arcs 1800, France.

Dilepton Forward-Backward Asymmetry and electroweak mixing angle at ATLAS and CMS

From the TeVatron to the LHC UK HEP Forum, 7-8 May 2009 Emily Nurse

(4) How do you develop an optimal signal detection technique from the knowledge of

Analysis of Shane Telescope Aberration and After Collimation

2 ATLAS operations and data taking

Analysis and discussion of the recent W mass measurements

Transcription:

Fermi National Accelerator Laboratory FERMILAB-Conf-99/292-E CDF and D0 New W Mass Results from CDF and D0 Bill Carithers Lawrence Berkeley Laboratory Berkeley, California Fermi National Accelerator Laboratory P.O. Box 500, Batavia, Illinois 60510 October 1999 Published Proceedings of the International Europhysics Conference on High Energy Physics, Tampere, Finlad, July 15-21, 1999 Operated by Universities Research Association Inc. under Contract No. DE-AC02-76CH03000 with the United States Department of Energy

Disclaimer This report was prepared as an account of work sponsored byan agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specic commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reect those of the United States Government or any agency thereof. Distribution Approved for public release; further dissemination unlimited. Copyright Notication This manuscript has been authored by Universities Research Association, Inc. under contract No. DE-AC02-76CH03000 with the U.S. Department of Energy. The United States Government and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a nonexclusive, paid-up, irrevocable, worldwide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government Purposes.

FERMILAB/PUB/CONF-99/292-E New W mass results from CDF and D0 Bill Carithers Lawrence Berkeley National Laboratory On behalf of the CDF and D0 collaborations E-mail: carithers@fnal.gov Abstract This article describes recent measurements of the W mass by the CDF and D0 Collaborations. CDF obtains a preliminary result of 80.473 0.113 GeV for the W mass in the electron channel and D0 reports a preliminary result of 80.766 0.234 GeV for electrons in the more forward (Endcap) rapidities. When combined with all previous measurements, the current average for the W mass measured at the Tevatron is 80.450 0.063 GeV. 1. Introduction The W mass is a direct and stringent test of the Standard Model. The value at tree level is precisely predicted and loop corrections are sensitive to the square of the top mass and the logarithm of the higgs mass. Just as precise EWK measurements gave indirect evidence for a top mass near 175 GeV before the top was discovered, precise measurements of the W mass will either give some indication of the higgs mass or a signal for new physics. The recent Tevatron run was divided into two periods, usually denoted Run Ia (1992-93) and Run Ib (1993-95). Both CDF and D0 have published [1] W mass results from Run Ia and achieved a combined uncertainty of 150 MeV. Using the higher statistics from Run Ib( 90 pb,1 ), D0 has published [2] results based on W decays to the electron channel in the central region,jj < 1. CDF has presented preliminary results [3] for W s decaying in the muon channel. This paper describes two new results and combines all previous Tevatron measurements into the current best average. D0 has augmented their analysis by extending the electron pseudorapidity coverage into the endcap region,1:5 < jj < 2:5. CDF has completed the analysis in the electron channel and improved the systematic uncertainty in the muon channel. 2. Measurement technique The hadron collider environment imposes many restrictions on the detectors and consequently on experimental observables. One of the most important of these is a restricted rapidity coverage so that longitudinal momentum conservation is no longer a useful constraint. Consequently, the W mass analysis uses the transverse components of momentum and energy. Moreover, the neutrino from W decays is not directly detected but inferred from the missing transverse energy, 6E T, required to conserve momentum in the transverse plane. The most useful measure of the W mass is the transverse mass, M T, the two-dimensional analogue of the invariant mass since this quantity is independent of the W P T to first order. The transverse mass is given by q M T = 2P l T 6E T(1, cos ) where is the angle between ~ 6E T and ~ P l T. It is also convenient to split 6E T into two components, the (dominant) lepton transverse momentum and a (usually small) recoil term, ~ U: ~ 6E T =,( ~ U + ~ P l T ) The recoil term contains contributions from QCD initial state radiation and from any additional pp interactions that occur in the same beam crossing as the W production. These are treated in more detail in later sections. 3. Energy scale Any error in the energy/momentum scale of the lepton enters directly in the W transverse mass. Both CDF and D0 use the Z mass reconstructed from leptonic decays to set the scale. The scale is adjusted until the Z mass agrees with the very precise value from LEP. In that

2 sense, both collaborations actually measure the ratio of the W and Z masses. Specifically, D0 assumes that the observed E T is given by a scale factor which multiplies the true E T plus an offset term. The scale factor and offset are determined by simultaneous fits to the Z mass as a function of the Z P T,theJ= mass from J=! e + e, decays, and to 0 double-dalitz decays [1]. The scale factor is transferred to electrons in the endcap by using Z decays where one electron is in the central region and the other in the endcap. CDF uses the Z mass in Z! +, decays to set the momentum scale. Any non-linearities in the momentum scale are limited by measuring the Z mass, the mass from! decays, and the J= mass also from decays, all as a function of track curvature. The electron energy scale is set by the Z mass in Z! e + e, decays. A small non-linearity in the electron energy measurement is determined by measuring the ratio of electron transverse energy to transverse momentum, E/p, as a function of E T in the high-statistics W! e sample. Parenthetically, CDF also attempted an absolute scale measurement based on E/p but this was abandoned when the simulation was not adequate to reproduce the correct value for the Z mass. Both CDF and D0 use the line shape of the Z mass to determine the lepton energy resolution which enters directly in the fits to the M W T distribution for the W mass. 4. W production model The details of how the W is produced enter the mass measurement in two ways. First, in the transverse direction any P W T will boost the Pl T and 6E T distributions and enter directly when these distributions are fit for the W mass. The transverse mass is less sensitive but P W T effects do enter at higher order. In the longitudinal direction, the W rapidity would be irrelevant if the detectors had full coverage. With limited coverage, the shape of the M W T distribution would be biased if the W production were not well-modelled. The W P T distribution is determined by measuring the Z P T distribution in leptonic decays where the resolution is very good and then appealing to the theoretically well-known ratio of W to Z production. The uncertainty is entirely limited by the statistics of the Z sample. The Z sample is also used to understand how the detectors respond to the recoil energy when the W is produced with appreciable P T as noted earlier in the discussion of 6E T. The recoil measured by the calorimeters is compared to the Z P T. The recoil component transverse to the Z direction is unbiased and shows a resolution expected from minimum bias events. The recoil component parallel to the Z direction is influenced by jets in the event and typically shows a poorer resolution and a bias, < U k, P Z T >.Thisbias enters as a correction in modelling the W recoil. The uncertainties are limited by the Z statistics and translate typically to an uncertainty in the W mass of about 25-40 MeV. The W rapidity distribution is determined by the parton distribution functions (PDF). The W mass is sensitive to any differences in the momentum fraction carried by the up quark compared to the down quark. Experimentally, the up quark does carry a larger fraction of the proton momentum and this leads to a charge asymmetry in the W decays. Specifically, the W +(,) is produced preferentially along the p(p) direction. CDF has measured the charge asymmetry [4] as a function of rapdity, and both CDF and D0 use this measurement to constrain the systematic uncertainty due to the PDF s. 5. Mass fits To fit for the W mass, a full simulation is used to generate templates of the M W T at discrete values of the W mass and width. These simulations include backgrounds, W production details, detector resolutions, and detector responses as described above. A maximum likelihood fit for data comparisons with the templates gives the most likely value of mass and width. Having shown that the best fit value for the width is compatible with the Standard Model prediction, the data are re-fit for the mass with the width fixed at the Standard Model value. The fits for the D0 endcap data and the CDF muon and electron data are shown in Figure 1. The P l T and 6E T distributions can also be fit for the W mass. As discussed above, these distributions are more sensitive to P W T. They are very highly correlated with the M T distribution but do contain some independent information. D0 uses this information to reduce the systematic uncertainties somewhat while CDF uses the P l T and 6E T fits only as consistency checks. The uncertainties are shown in Table 1. In this table, the uncertainty labelled statisitcal refers only to the uncertainty in the maximum likelihood fits to the M W T templates. We emphasize that, although the remaining uncertainties are usually considered systematic, they are in fact determined by the statistics of ancillary data sets. 6. Conclusions Both CDF and D0 have reported new measurements of the W mass. When combined with previously published values, D0 reports a value of 80.474 0.093 GeV and CDF obtains 80.433 0.079 GeV. The combined Tevatron average is then 80.450 0.063 GeV where a common systematic error of 25 MeV includes the highly correlated PDF s and QED corrections. For the first time, both collaborations have reduced the total error

3 Error source D0(EC) CDF(e) CDF() Statistical 107 65 100 Lepton (E,p) scale 188 75 85 P W T and recoil 52 40 40 Detector resolution 46 25 20 PDF 35 15 15 Backgrounds 20 5 25 other systematics 11 20 21 Total error 234 113 143 Mass value(gev) 80.440 80.473 80.465 Combined mass(gev) 80.497.098 80.470 0.089 Table 1. Summary of uncertainties (in MeV). The D0 combined value includes the published data from the central region. below 100 MeV and the combined Tevatron average is comparable to the combined LEPII results. Taken together, the Tevatron plus LEPII results still prefer a light higgs mass [5]. References [1] F. Abe, et al., 1995 Phys. Rev. Lett. 75 11, S. Abachi, et al., 1996 Phys. Rev. Lett. 77 3309 [2] B. Abbott, et al., 1998 Phys. Rev. Lett. 80 3000 [3] M. Lancaster 1997 Proceedings of Les Recontres de Physique de la Vallee d Aoste, La Thuile, 233 [4] F. Abe, et al., 1998 Phys. Rev. Lett. 81 5754 [5] See LEP Electroweak Working Group at URL http://www.cern.ch/lepewwg

4 # Events 2000 1500 1000 CDF(1B) Preliminary W eν χ 2 /df = 82.6/70 (50 < M T < 120) χ 2 /df = 32.4/35 (65 < M T < 100) Mw = 80.473 +/- 0.065 (stat) GeV Backgrounds KS(prob) = 16% 500 Fit region 0 50 60 70 80 90 100 110 120 Transverse Mass (GeV) # Events 500 450 400 350 300 250 200 150 100 50 0 CDF(1B) Preliminary W µν Fit region χ 2 /df = 147/131 (50 < M T < 120) χ 2 /df = 60.6/70 (65 < M T < 100) Mw = 80.465 +/- 0.100 (stat) GeV Backgrounds KS(prob) = 21% 50 60 70 80 90 100 110 120 Transverse Mass (GeV) Figure 1. Transverse mass distributions compared to the best fit. LEFT : D0 s published central-electron analysis and preliminary end-cap analysis. RIGHT : CDF s electron and muon channel analyses. The fit likelihood and residuals are also shown for the two DO/ distributions.