Protocol for Use of BCMP Jasco J-815 Circular Dichroism Spectropolarimeter

Similar documents
Jasco V-670 absorption spectrometer

Kinetics of Crystal Violet Bleaching

Zetasizer Nano-ZS User Instructions

Measuring ph with Smart Cuvettes

Size Determination of Gold Nanoparticles using Mie Theory and Extinction Spectra

Determining the Concentration of a Solution: Beer s Law

Introduction to Spectroscopy: Analysis of Copper Ore

Connect the Vernier spectrometer to your lap top computer and power the spectrometer if necessary. Start LoggerPro on your computer.

Determining the Concentration of a Solution: Beer s Law

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Fluorescence Spectrophotometry


Chemical Kinetics: Integrated Rate Laws. ** updated Procedure for Spec 200 use **

Photosynthesis. LabQuest OBJECTIVES

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Physics Department. Experiment 03: Work and Energy

Spectrometer User s Guide

1iI1E. The Determination of 0 an Equilibrium Constant [LU. Computer

CH 112 Special Assignment #4 Chemistry to Dye for: Part C

The Determination of an Equilibrium Constant

Determining the Concentration of a Solution: Beer s Law. Evaluation copy. Figure 1

The Determination of an Equilibrium Constant

Determining the Concentration of a Solution: Beer s Law

The Determination of an Equilibrium Constant

Spectroelectrochemistry Part 2: Experiments and Data evaluation

Introduction. Concepts Kinetics Order of reaction Reaction rate Colorimetry. Background

AP BIOLOGY Photosynthesis

Introduction to Spectroscopy: Analysis of Copper Ore

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

Rate Law Determination of the Crystal Violet Reaction. Evaluation copy

2 (aq) [FeSCN [Fe 3JSCN] Figure 1

ICP-OES DETERMINATION OF IRON. Introduction:

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

Aspirin Lab By Maya Parks Partner: Ben Seufert 6/5/15, 6/8/15

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

Photoluminescence Spectrometer (FLS980)

REVIEW OF LAB TECHNIQUES

Electrochemical Techniques: Cyclic Voltammetry

Hydration of Propionaldehyde by Temperature-Jump Relaxation 1

Circular Motion and Centripetal Force

The Synthesis and Analysis of Aspirin

Investigating Food Dyes in Sports Beverages. Sample

Lab 5: Calculating an equilibrium constant

Predictor Assay Setup Guide on the Tecan Safire 2 Microplate Reader

Instructor s Advance Preparation

Chirascan 6-Cell Peltier Cell Holder: Rapid Optimisation of Buffer Conditions for Stabilising Protein Therapeutics

Predictor Assay Setup Guide on the BMG LABTECH CLARIOstar Microplate Readers

How to Make Photometric & Colorimetric Measurements of Light Sources using an Ocean Optics Spectrometer and SpectraSuite Software

Finding the Constant K c 4/21/15 Maya Parks Partners: Ben Seufert, Caleb Shumpert. Abstract:

Structural Analysis of an Unknown Compound and Determination of its pk a by NMR Spectroscopy

Surface Zeta Potential Cell (ZEN1020)

LAB 3: WORK AND ENERGY

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013

Chemical Equilibrium: Finding a Constant, Kc

Lab 1a Wind Tunnel Testing Principles & Drag Coefficients of Golf balls

Standard Operating Procedure. edaq Potentionstat. Miramar College Potentiostat. -Report by Marianne Samonte, Dec 2009

Mnova Software for Analyzing Reaction Monitoring NMR Spectra

Experiment 11 Beer s Law

Spectrophotometer for Life Science. BioSpec-nano C101-E112D

CRL MASS SPECTROMETRY FACILITY USER MANUAL LCT CLASSIC A & B

Atomic Spectra HISTORY AND THEORY

Background The power radiated by a black body of temperature T, is given by the Stefan-Boltzmann Law

Shown below is a sample titration curve for a diprotic acid. Note the two equivalence points.

Determination of an Equilibrium Constant

Fourier Transform Infrared Spectroscopy (Perkin Elmer - Spectrum One)

Experiment 1 Chemical Kinetics 1

Boyle s Law and Charles Law Activity

IncuCyte ZOOM NeuroTrack Fluorescent Processing

User Manual Chirascan CS/ORD

Experiment 7. Determining the Rate Law and Activation Energy for the Reaction of Crystal Violet with Hydroxide Ion

Ocean Optics Educational Spectrometers. Getting Started Manual

In-Solution Digestion: Multi-Plate v1.0 Quick Start Guide

Protein extraction and quantification by Teresa Fan, University of Kentucky BUFFER PREPARATION AND STORAGE

Chemical Equilibrium: Finding a Constant, Kc

Soil Cation Analysis Using High-Performance Capillary Zone Electrophoresis Last Modified: October 20, 2006

Experiment 11 Beer s Law

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

EXPERIMENT 6 INTRODUCTION TO SPECTROSCOPY

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Using a mini-gas Chromatograph (GC): Identifying Unknown Compounds

Introduction to Spectroscopy: Analysis of Copper Ore

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Physics Department

Spectroscopy II Introduction: Spectrophotometry and Fluorometry

Enzymes. Lab Exercise 7. Introduction. Contents. Objectives

CHEMISTRY SEMESTER ONE

Chem Page IX - 1 LAB MANUAL Differential Scanning Calorimetry 09_dsc131.docx EXPERIMENT IX

pka AND MOLAR MASS OF A WEAK ACID

Supplemental Material

Measuring the time constant for an RC-Circuit

v Prerequisite Tutorials GSSHA WMS Basics Watershed Delineation using DEMs and 2D Grid Generation Time minutes

A Study of Beer s Law Prelab

Physical Chemistry Lab: The Hydrolysis of Aspirin. Each collaborative team determines the rate constant for the hydrolysis of aspirin.

UV-Vis optical fiber assisted spectroscopy in thin films and solutions

Virtual Cell Version 4.0 Membrane Potential

Introduction to Chemistry Techniques Prelab (Week 1) 2. Determine the number of significant figures in each of the following numbers.

Determination of the Rate of a Reaction, Its Order, and Its Activation Energy

Rate law Determination of the Crystal Violet Reaction Using the Isolation Method

CEE 697K Bromide Lab

C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science

DOAS measurements of Atmospheric Species

Transcription:

Protocol for Use of BCMP Jasco J-815 Circular Dichroism Spectropolarimeter Getting Started 1. Turn on the nitrogen: Open the valve on the nitrogen tank (max 10 psi) so that the pressure gauge on the left side of the CD reads ~15 units. If the attached tank is less than ½ full, then please tell Kelly. If the tank is empty, DO NOT PROCEED. Nitrogen gas is essential. 2. Turn on water bath (Usually set at 20 C, may be set to 25 for variable temperature measurements). 3. Turn on the Peltier temperature control unit. 4. Turn on the Jasco J-815 CD. Spectral Scan Measurement Set Up computer and temperature control 1. Open the program Spectrum Manager 2 on the desktop. 2. To measure the spectrum, double click Spectra Measurement. 3. Instrument will be initialized and self tested. a. Allow the N2 purge step to complete b. Lamp will be automatically turned on c. allow about 30 minutes for lamp to warm up 4. Connect the Peltier Cell Holder Accessory a. Control Menu Select Accessory b. Check box for Peltier Type FDCD Cell Holder c. Click ok 5. Set temperature from settings in temperature control window or Control Menu accessory PFD-425S. 6. Set parameters: a. Go to Measure menu Parameters b. General standard settings i. Photometric mode channels # 2 channel 1 CD channel 2 HT (voltage) i. Sensitivity Standard ii. D.I.T 1-2 seconds (data integration time, longer times give cleaner data but smooth out finer features) iii. Band Width 1 nm (try 2 nm if signal is low, especially for β) iv. Start 260nm v. End 190 nm vi. Data Pitch 0.1-0.5 nm

Loading Sample vii. Start mode Immediate viii. Scanning Mode Continuous ix. Scanning Speed 50-100 nm/min x. Accumulation 5 Accumulations/Repeat Mode toggled = accumulation, measures 5 times and averages untoggled = repeat mode, saves each cycle separately c. Control i. correction none (baseline subtraction not recommended) ii. make sure checkbox to open the shutter is checked d. Accessory i. control Temp 20 C ii. control sensor holder iii. Monitor sensor holder iv. start conditions start immediately or keep within ±0.3 C for 3-5s e. Information add experimental details (optional) f. Data i. enable AutoSave (optional, but recommended) ii. chose AutoSave directory and select name format (eg: date, number) 1. Total sample should equal approximately 300 μl, for standard 1mm cuvette a. concentration around 0.2 mg/ml (1-10 μm. see guidelines for protein concentration) 2. fill cuvette with sample, remove air bubbles 3. Once the sample is loaded, place the cap back on the cuvette and clean it with a kimwipe. Next, open the hinged lid on the right side of the top of the CD. 4. In the middle of this space should be a black circular cap with two screws in the top. Remove this cap. Underneath this cap is a rectangular cell holder. When using a 1 mm patch cuvette, place the black rectangular cuvette spacer in the cell holder. Make sure that the side with the hole is down when you place it in the holder and that light can pass through it. 5. Next, place the cuvette in the cell holder. 6. Replace the black cap, and the hinged lid. 7. Leave this for a few minutes, then remove the cuvette and check for bubbles that have formed due to the temperature change. If any have formed tip the cuvette 45 degrees, and tap it carefully to dislodge the bubbles. 8. Wipe the cuvette again and replace it.

Running a Scan 1. In the Spectra Measurement program, Go to Measure Sample (or click the S button) 2. The data will be graphed from right to left. 3. The top graph is the CD, the bottom is the HT(voltage). a. A good CD graph will not dip below -50 (Unit) b. A good HT graph will not get above 600 (Unit) until ~200 nm or lower c. If the CD goes below -50 (Unit) or the HT gets above 600 (Unit) before 200 nm, it may mean that the concentration of the sample is too high or there s an absorbing component in the buffer (such as chloride). 4. These scans can be viewed in the Spectra Analysis program (see below) Shutting Down and Clean Up 1. Remove cuvette and cuvette holder from CD, replacing the lid and cap afterwards. 2. Dispose of sample by either recollecting it or throwing it out in the appropriate manner. 3. Wash Cuvette. 4. Turn off CD, Water Bath, Temperature Control Unit, and computer/monitor, but DO NOT turn off the gas. 5. Let gas run for 5 minutes to remove the ozone from the system, then shut off the 6. gas 7. You can save the data as a txt file (save as) and thus import in rapidly into a graphing program for further manipulation.

Spectra Measurement Data Analysis 1. Open the program Spectrum Manager 2. 2. To analyze data, double click spectra analysis 3. Open buffer file: File open <your buffer blank> 4. Open sample file (it will be active, if not, select sample trace to designate active spectrum) 5. Overlay data a. Drag one spectrum onto another view to overlay spectra 6. Subtract baseline a. Overlay sample and baseline spectra b. Go to Processing Subtraction c. A subtracted file is created in memory d. Select the subtracted file and Save As molar ellipticity, [θ] (deg cm 2 dmol -1 ) [θ] = & (()*+) -. 01 234 5 6 7(8() where: θ = ellipticity (mdeg) C = concentration (mol/l) l =pathlength (cm) mean residue ellipticity [θ]mrw (deg cm 2 dmol -1 ) For proteins/peptides, mean residue ellipticity is often preferred where: Cresidue = n Cpolymer n = number of residues [θ] = & (()*+) -. 0 9:;<=>: 1 234 5 6 7(8() OR [θ] (?@ = where: MWR θ c l ABC & (()*+) -. 8( D 5 ) 7(8() = mean residue weight = molecular mass/n-1, N = number of amino acids (~110 for most proteins) = ellipticity (mdeg) = concentration (g/l) =pathlength (cm)

Collecting Thermal Denaturation Data There are two methods for collecting thermal melt (denaturation) data. A Variable Temperature Measurement measures one or more wavelengths as a function of temperature. A Temperature Interval Measurement measures an entire spectral scan at each temperature. Perform Getting Started as outlined above for Spectra Measurement. Variable Temperature Measurement Set Up computer and temperature control 1. Open the program Spectrum Manager 2 on the desktop. 2. Double click Variable Temperature Measurement. 3. Instrument will be initialized and self tested. a. Lamp will be automatically turned on b. lamp will need ~30 min. for stabilization 4. Set parameters: Measure menu Parameters standard settings a. Temp i. Start temp 20 C ii. sampling C 1 C iii. Target C 95 C iv. Ramp Rate 1 C/min v. Wait 6-60 sec (longer for slow unfolding kinetics) more than one ramp stage can be combined if you know the approx. Tm eg. stage 1: measure every 5C from 20-40C stage 2: measure every 1C from 40-60C stage 3: measure every 5C from 60-95C b. Start/End i. start condition keep within ± 0.2 C for 3 sec ii. end condition return to start temp (or 20C) c. General i. Photometric mode channels # 2 channel 1 CD channel 2 HT (voltage) ii. Wavelengths wavelength of interest (222, 218, 208, etc) iii. Sensitivity Standard iv. D.I.T. 2 sec v. Bandwidth 1 nm d. Control, Info and Data i. as for Spectra Measurement

ii. if you do NOT use AutoSave, you must remember to "Save All Data" when collecting more than one wavelength. "Save Data" will only save the active wavelength 5. Load the sample according to Loading the Sample above. 6. Go to Measure Sample (or click S button) 7. If you did not select AutoSave, then Save ALL Data (to save all wavelengths) or Save Data (to only save the active wavelength) 8. When the run is finished, shut down as described above in Shutting Down and Clean Up, as for Spectra Measurement. a. NOTE: One thing to note with these temperature measurements is that they can take a while depending on how the parameters are set. b. NOTE: after thermal denaturation experiments, proteins are more likely to precipitate on the cuvette, wash cuvette with care. Variable Temperature Data Analysis 1. Open the program Spectrum Manager 2. 2. To analyze data, double click spectra analysis 3. Open sample file: File open <your sample file> 4. Truncate Data a. Processing Corrections Truncate Data b. click apply for default parameters c. default method: 3 rd order spline d. temperature range may be truncated, as needed 5. Calculate 1 st Derivative a. Processing Operations Derivatives b. click ok to apply default methods c. defaults i. Algorithm: Savitzky-Golay ii. Order of derivatives: 1 st order iii. Order of polynomial: 1 st order iv. data points: 7 (adjust to increase smoothing) 6. Find Tm peak a. Processing Peak Processing Peak Find b. select Parameters: Top c. click apply d. the peak center is the melting temperature (Tm)

Temperature Interval Measurement A Temperature Interval Measurement measures an entire spectral scan at each temperature, and will therefore take longer than a Variable Temperature Measurement due to the delay to collect a complete scan (or multiple scans in accumulation mode). For this reason a wider sampling interval (2-5 C) is recommended. Set Up computer and temperature control 1. Open the program Spectrum Manager 2 on the desktop. 2. Double click Temperature Interval Measurement. 3. Instrument will be initialized and self tested. a. Lamp will be automatically turned on b. lamp will need ~30 min. for stabilization 4. Set parameters: Measure tab Parameters standard settings a. Temp i. Start/End 20-95 C ii. Data Pitch (2-5 C) iii. Temp. Gradient 1-2 C/min iv. Delay time 6 sec v. start condition keep within ±0.2C for 3 sec vi. end condition return to start (or move to 20C) b. All Other tabs as for Spectra Measurement 5. Set wavelengths to monitor: Measure tab Monitor Parameters a. Enter up to 4 wavelengths to monitor during data collection b. Check boxes next to wavelengths to be used last edited: 2018-02-21