Clean Corona Ionization Technology. Peter Gefter Simco-Ion phone: (1)

Similar documents
Technology Solution. Principles of Sheath Technology and Low Maintenance Ionizers. The Operation of Corona Ionizers. The Creation of White Fuzzballs

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

Generating Air Ionization With No Contaminating Particles

Semiconductor Detectors

Ion Pump Applications

Recent Advances and Challenges in Nanoparticle Monitoring for the Semiconductor Industry. December 12, 2013

PARTICLE MEASUREMENT IN CLEAN ROOM TECHNOLOGY

Secondary Ion Mass Spectroscopy (SIMS)

Mitigating Electrostatic Effects on Measurement Accuracy

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

Table of Content. Mechanical Removing Techniques. Ultrasonic Machining (USM) Sputtering and Focused Ion Beam Milling (FIB)

Chapter 5: Nanoparticle Production from Cathode Sputtering. in High-Pressure Microhollow Cathode and Arc Discharges

Fundamentals of Particle Counting

Double Side Charging of Glass Substrates

Controlled Environment Testing Report

An Estimation for Relaxation Characteristics of an Ionizer Ion Cloud Density Transferred through a Pipe via Hyperbolic Law

Sputter Ion Pump (Ion Pump) By Biswajit

Defining quality standards for the analysis of solid samples

Plasma Surface Modification for Cleaning and Adhesion Ron Nickerson, Vice President AST Products, Inc. Billerica, MA

PHYSICAL VAPOR DEPOSITION OF THIN FILMS

Physics 1000 Half Life Lab

Introduction. Principle of Operation

Sealeze TM SSG515AT2D Static Dissipation Brush Performance in an Operational Environment

Aspects of Single Wafer Cleans Processing and Tools

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

Product data sheet Palas Nanoparticle measurement system DEMC 2000

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Product data sheet Palas U-SMPS 1050 / 1100 / 1200

6.5 Optical-Coating-Deposition Technologies

Etching Issues - Anisotropy. Dry Etching. Dry Etching Overview. Etching Issues - Selectivity

Know thy Enemy : Understand and Control Particle Contamination. March 10th, 2008 Kirk Buecher

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

Mobility-Based Particle Size Classification and Detection down to 2nm Theory to Practice

Lab NUC. Determination of Half-Life with a Geiger-Müller Counter

ION Pumps for UHV Systems, Synchrotrons & Particle Accelerators. Mauro Audi, Academic, Government & Research Marketing Manager

08 - Miscellaneous and historical detectors

Plasma Processing in the Microelectronics Industry. Bert Ellingboe Plasma Research Laboratory

Gaetano L Episcopo. Scanning Electron Microscopy Focus Ion Beam and. Pulsed Plasma Deposition

Field-Free Atmospheric Ionization: Atmospheric Pressure Chemical Ionization & Electrospray

Water Desorption from Metallic Surfaces at Room Temperature

Information about the T9 beam line and experimental facilities

SECTION 8 Part I Typical Questions

arxiv:physics/ v2 27 Mar 2001

Chapter 3 Electrochemical methods of Analysis-Potentiometry

M M e M M H M M H. Ion Sources

Hiden SIMS Secondary Ion Mass Spectrometers. Analysers for surface, elemental and molecular analysis

Interface (backside) & Extraction Lens

PRODUCTION OF DRUG NANOPARTICLES OF CONTROLLABLE SIZE USING SUPERCRITICAL FLUID ANTISOLVENT TECHNIQUE WITH ENHANCED MASS TRANSFER

Multicusp Sources for Ion Beam Lithography Applications

The Franck-Hertz Experiment Physics 2150 Experiment No. 9 University of Colorado

RANGE OF ALPHA PARTICLES

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

Lecture 10. Vacuum Technology and Plasmas Reading: Chapter 10. ECE Dr. Alan Doolittle

Electrical Discharges Characterization of Planar Sputtering System

Experiment Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

INSTRUCTOR RESOURCES

Extrel Application Note

Multi-element process analyzer

Chapter 3 Engineering Science for Microsystems Design and Fabrication

The new 11-R (one part of the Mini WRAS) and GRIMM MINI-WRAS Andreas Jaksch. Symposium Stockholm Mai

Supporting Information

Instrumentation and Operation

Chapter 7 Separation of Particles from a Gas

PHI 5000 Versaprobe-II Focus X-ray Photo-electron Spectroscopy

COPLEY S C I E N T I F I C. A multi-function aerosol system with aerosol generation, classification and monitoring capabilities for:

Test method to assess the suitability of materials and surfaces to avoid problems from static electricity by measurement of capacitance loading

Alpha-particle Stopping Powers in Air and Argon

DETECTORS. I. Charged Particle Detectors

Chem 481 Lecture Material 3/20/09

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

Chapter Seven (Nuclear Detectors)

AMS MEASUREMENTS OF DEUTERIUM CAPTURED IN TUNGSTEN LAYERS DEPOSITED BY MAGNETRON SPUTTERING

Chlorine and Hydrogen Chloride Monitoring Utilizing Ion Mobility Spectroscopy (IMS)

ISO INTERNATIONAL STANDARD. Determination of particle size distribution Differential electrical mobility analysis for aerosol particles

Low Voltage Contact Electrostatic Discharge Phenomena

STRONG DOUBLE LAYER STRUCTURE IN THERMIONIC VACUUM ARC PLASMA *

Processing of Semiconducting Materials Prof. Pallab Banerji Department of Metallurgy and Material Science Indian Institute of Technology, Kharagpur

Technical Data Sheet. Pb Free. Specification GR101 SSC. Customer. Rev. 02 January 서식번호 : SSC- QP (Rev.0.

NUCLEI, RADIOACTIVITY AND NUCLEAR REACTIONS

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Quality Assurance. Purity control. Polycrystalline Ingots

Differential Mobility Particle Sizer (Aerosol measurements)

Study of DC Cylindrical Magnetron by Langmuir Probe

AIR-O-CELL CSI. Bioaerosol Sampling Cassette For the collection of viable and non-viable airborne particles. Laboratory & User Manual

Attention is drawn to the following places, which may be of interest for search:

Chapter 4 Scintillation Detectors

Auger Electron Spectroscopy (AES)

Electric Field Measurements in Atmospheric Pressure Electric Discharges

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Effect of Spiral Microwave Antenna Configuration on the Production of Nano-crystalline Film by Chemical Sputtering in ECR Plasma

Department of Physics & Astronomy Undergraduate Labs. Measuring the Electric Force with the Milligram Balance

ETCHING Chapter 10. Mask. Photoresist

LAAPD Performance Measurements in Liquid Xenon

3 A NEW FRENCH FACILITY FOR ION PROPULSION RESEARCH

ICPMS Doherty Lecture 1

PRINCIPLES OF PLASMA DISCHARGES AND MATERIALS PROCESSING

RADIATION-METER TM-91/TM-92

Ionization Detectors. Mostly Gaseous Detectors

On Pulse Charging of Lead-Acid Batteries Cyril Smith, November 2010

MARINELLI BEAKERS CATALOG

Transcription:

Clean Corona Ionization Technology Peter Gefter Simco-Ion phone: (1) 510-217-0614 email: pgefter@simco-ion.com Jack Menear Jack Menear Associates phone: (1) 831-462-9338 email: jack.menear@gmail.com) Abstract - A need for clean corona ionizers has been long recognized (but unrealized) within the semiconductor, disk drive, and photonics industries. Particle-ion mobility separation provides the solution. Lower-weight ions reach the target; higher-weight particles are trapped. Cleanliness matches X-ray and nuclear ionizers with lower cost, less maintenance, and fewer installation/safety barriers. I. SUMMARY Clean (particle free) corona ionizers for static charge neutralization are an understood need, particularly for semiconductor processing, disk drive, photonics and other critical technologies. The semiconductor industry is expanding operation in noble and electropositive gases like argon and nitrogen to avoid oxidation of sensitive objects (products). Super clean conductive gas streams are ideal solutions for many static related problems [1, 2]. Protection of an ion emitter from ambient air with a dry air or nitrogen sheath is an effective method to decrease debris buildup. However, that method cannot protect ion emitter from corona/plasma related erosion or sputtering [3]. That means corona generated particle will move to the product by the same protective CDA/ nitrogen gas streams. The technique to achieve corona ionizer cleanliness in the nanoparticle range, especially for electro-positive gases, has been elusive for two reasons. First, ion balance control of bipolar corona discharge in electro-positive gases is forced to operate within an extremely tight range to prevent negative (electrons) current avalanches [3,4]. Corona feedback is optimized to maintain that tight ion current range. Page 1

Second, corona ionization is highly energetic, and the ion emitter surface is under continuous electron/ ion bombardment [1, 2]. Ion emitter reactions eventually generate particles in the 10-100 nm range. Some particle generation within a corona discharge is currently considered unavoidable. Clean corona ionizers are designed for operation in facilities, mini-environments and equipment, where compliance with ISO 14644 Class 1 (at 0.1 micron) and extended ISO Class 1 (at 10 nm) is specified. II. SEPARATING PARTICLES FROM IONS VIA ELECTRICAL MOBILITY Corona generated particles can be separated from charge carriers, like ions and electrons, using electrical mobility differences and vacuum. This separation occurs within the ion/electron generation plasma zone, which is close to the corona emitter tip. For example, diatomic nitrogen ions weigh 28 amu, and move quickly from the ion generation zone toward a reference (non-ionizing electrode). Then the ions continue moving toward a charged target via electrostatic repulsion. Particles are much heavier than nitrogen ions, move slower in an electric field, and are removed from the ionization zone with an internal vacuum strategy. In short, ions move toward the target of charge neutralization. In contrast, particles move away from the target (and toward the vacuum port), where they are captured with an internal filter. Ionization frequency, service gas flow rate, ionization zone dimensions, and vacuum flow rate are balanced to optimize performance. It should be noted that neither an external vacuum source nor an external filter is needed. The following diagram figure 1 visualizes concept the ion/particle separation. PARTICLES IONS Nitrogen flow Voltage Particles to vacuum and filter Fig. 1. In- line ionizer structure visualizing concept of the ion/particle separation Page 2

A high pressure source of gas (nitrogen or CDA) is connected to a channel inside the ionizer. A high velocity stream of clean gas flows through the channel at 30-100 liters/minute. An ion emitter is configured as a sharp point and positioned inside a protective nonconductive shell. The emitter tip is recessed relative to output orifice of the shell. High voltage power is connected to the blunt end of emitter. The back of the shell is connected to vacuum port and filter. A reference electrode is positioned outside the channel, and is connected to the same ground as the high voltage power supply. Gas ionization occurs when the high voltage exceeds corona threshold for the emitter/gas combination. Positive and negative charge carriers are produced by an AC corona discharge near the emitter tip. Electrical and diffusion forces move charge carriers from plasma region toward the reference electrode. In corona drift region (close to reference electrode), the intensity of the electric field is low, and the gas stream moves positive and negative ions through the channel outlet to target of charge neutralization. Ion emitters are usually made from corrosion-resistant metals, such as stainless steel, tungsten or titanium. According to Roger [1] stainless steel has the highest erosion rate, followed by thoriated tungsten emitters. Single-crystal silicon emitters have the lowest erosion rate. Moreover, semiconductor applications prefer non single-crystal silicon emitters to avoid contamination by metallic particles [1]. Corona discharge produces ions, electrons and byproduct particles in the plasma region [3]. Without a protective shell (see Figure 2) these particles would eventually be delivered to the charge neutralization target. With a protective shell, the gas flow pattern differs. The shell produces a pressure difference between the outlet and the vacuum port. Vacuum flow creates a drag force that moves particles from plasma region to vacuum port. Charge carrying ions move via the high intensity electrical field into the main gas stream, past the reference electrode, and to the target. Corona generated particles move by vacuum flow in the opposite direction to the filter, where they are trapped. Vacuum flow can be applied closer to the emitter tip through a side vacuum port as shown below. Page 3

Nitrogen - - + + - + Target vacuum and filter Fig. 2. Ion emitter protective shell with vacuum port. III. Testing Clean Corona Ionizers A. Simultaneous Measurements of Particles, Discharge Time and Ion Balance The test apparatus employed for simultaneous measurements is shown in Figure 3. Page 4

Relay & Timer (ON/OFF control) 12 inches 6 inches ionizer filter 90-105 feet/minute CPM DAC / Computer LPC CNC DAC / Computer DAC / Computer Fig. 3. Test setup for simultaneous monitoring ionizer performance and particle emission. In this test setup, the Monroe Model 280 CPM was 12 inches below the ionizer. Two particle counter probes were 6 inches below outlet of the ionizer - between the ionizer and the CPM. One laser particle counter had measuring sensitivity 100 nm. One Hach Model 1104 CNC particle counter had measuring sensitivity 10 nm. The main reason for this experimental setup is to collect data on particles and performance stability simultaneously. There is an option to turn on and of ionizer and monitor particles and performance during start up periods. This setup is efficient and allows a valid long term test. But naturally, discharge times are longer because particle probes are positioned between the CPM plate and the ionizer outlet. Page 5

Discharge Time (Seconds) or Balance (Volts) B. Long Term Discharge Times and Balance An example graph of discharge time (upper section of the graph) and ion balance (lower section of the graph) stability shown in Figure 4. Data was collected using the test setup in Figure 3. Ionizer was connected to Dewar with liquid nitrogen at 99.999 % purity. Discharge Time and Balance versus Time for Beta 4214 in Mini-environment #2 30 25 20 40 lpm nitrogen Model 280A CPM, 12 inches below 4214 (with particle count probes at 6 inches) Power cycled ON and OFF. Only ON cycle is plotted. Readings above 20 are associated with experimental changes = positive discharge time = negative discharge time = balance Plotted points are hourly averages 15 10 5 0 0-5 233 Hours Time Fig. 4. Discharge time and ion balance long term test results in nitrogen for clean corona ionizer. C. Shorter Performance Term Tests (without Particle Counts) To measure discharge times without interference from particle probes, Figure 3 was modified. The particle probes were removed, and the CPM was centered directly below the ionizer. The distance between ionizer and CPM was changed from 12 inches to 6 inches. As expected, much shorter discharge times are recorded. See Table 1 as an example. Page 6

Table 1: In-line ionizer performance in super clean nitrogen D isch arg e T im e (S eco n d s) an d B alance (V olts) at 6 Inches / No M anifold P ositive N egative Test Num ber Discharge Discharge Balance 1 2.4 2.7-4 2 2.4 2.7-5 3 2.5 2.7-5 4 2.4 2.8-4 5 2.4 2.5-6 Discharge times are defined as the time needed for the ionizer to reduce 1000 volts (either polarity) on a 20 Pico Farad CPM plate to 100 volts. D. Cleanliness Based on Particles 10 Nanometers Figures 5 and 6 show cleanliness achieved with the differential ion- particle mobility technology. In both cases, particle levels were below the extended ISO Class 1 (at 10 nm) limit. The limit of 34 per cubic foot is calculated by using the formula in ISO 14644, Section 3.2, entitled Classification Number *. * Note that extended ISO Class 1 (at 10 nm) is an in-house standard based on ISO Standard 14644. However, ISO Standard 14644 does not formally support extrapolation to 10 nm. Page 7

Particles per Cubic Foot of Nitrogen 10 nm 10 nm Particle Counts versus Time for Beta 4214 in Mini-environment #2 40 lpm nitrogen CNC probe was 6 inches below 4214. 50 45 40 35 30 25 20 15 10 5 0 Measurements made after a firmware change to V1.0. Power cycled ON and OFF. Data points may mix ON and OFF conditions. Plotted points are hourly averages Extended ISO Class 1 limit = 34 70 Hours Time Fig. 5. In-line ionizer cleanness test results in nitrogen with cycled power on and off. Page 8

Particles per Cubic Foot of Ionized Nitrogen 6 Inches below Outlet 100 nm particles/ft 3 averaged 0.011. The ISO Class 1 limit is 0.283. 10 nm particles/ft 3 averaged 4.7. The extended ISO Class 1 limit is 34. Balance (not plotted) ranged from 0 to -3 volts. 340 Extended ISO Class 2 Limit for 10 nm Particles = 340 60 50 Ionizer flow rate was 90 liters/minute = 10 nm particles = 100 nm particles 40 30 Extended ISO Class 1 Limit for 10 nm Particles = 34 20 10 0 21.75 Hours Fig. 6. In-line ionizer cleanness test results with high flow rate of super clean nitrogen gas. Ionizers in Figures 5 and 6 used single crystal silicon emitters. Ionization voltage at nominally 40 khz was applied to the emitter. Voltage amplitude was optimized to minimize emitter erosion, to minimize particle generation, and to deliver robust ion output. Tests were performed in ISO 14644 Class 1 (at 0.1 micron) clean rooms. Temperature and humidity were monitored, but not controlled. The differential mobility cleanliness strategy reduced 10 nm particles by a factor of 261 when vacuum flow was between 3 and 10 liters/minute. In one example without vacuum applied, 10 nm particles averaged 1226 per cubic foot. With vacuum applied, 10 nm particles averaged dropped to 4.7 per cubic foot (refer to Figure 6). Page 9

E. Particles 100 Nanometers Particles 100 nm averaged 0.011 per cubic foot of air. This is well below the ISO Class 1 (at 0.1 micron) of 0.283 per cubic foot. IV. PARTICLE MEASUREMENT EQUIPMENT AND PARAMETERS A. Particles 100 nm were measured with a Hach [Met One] Model 2100C laser particle counter. The Model 2100C samples air or nitrogen at a rate of 1 cubic foot per minute. Each sample period was 10 minutes with a 5 minute hold period between samples. For data reduction, particle counts in each 10-minute sample period were divided by 10 to get average particles per cubic foot. B. Particles 10 nm were measured with a Hach [Met One] Model 1104 CNC particle counter. The Model 1104 samples air or nitrogen at a rate of 0.1 cubic foot per minute. Each sample period was 10 minutes with a 5 minute hold period between samples. Particle counts in each 10-minute sample period represent the particles per cubic foot. No division is needed. V. DISPERSION NOZZLE FOR LARGE AREA DISCHARGE Because the ions are created close to the ionizer s delivery tube, addition of a fast-through dispersion nozzle or manifold allows to cover wide area static charges neutralization [8]. With an ionizer 500 mm from a target plane, a 1000 mm by 400 mm rectangle era can be discharged within useful time periods. VI. EDUCTOR FOR INTERNAL VACUUM / CONSERVATION OF NITROGEN An on-board eductor captures some of the energy of incoming pressurized nitrogen/ CDA to generate the particle removal vacuum. External vacuum is not needed. Nitrogen (or other gas) is not lost in the filtration process. After particles are removed by filtration, evacuated nitrogen is returned to the main nitrogen flow. Page 10

VII. OPERATION WITH CDA OR HIGH PURITY NITROGEN / CLEANLINESS TARGETS The above information focuses on application to a nitrogen/argon environment. However, the technology is adaptable to CDA (clean dry air). Corona discharge in CDA further generates byproducts like ozone and nitrogen oxides. Vacuum flow in plasma zone significantly reduces all corona byproducts. In both electropositive and negative gases, particle concentrations in the ionized gas are below the quality control specification of 34 particles per cubic foot of gas 10 nm. REFERENCES 1. W.W. Roger at al Contamination and ESD control in high-technology manufacturing, book, p.p. 86-88. Wiley - Inter Science publication, 2006. 2. K. D. Murray at al. Clean Corona Ionization EOS/ESD Technology Dec. 1991/Jan 1992. 3. R.P. Donovan Particle control for semiconductor manufacturing, book, Marcel Dekker, Inc, 1990. 4. A. S. Biris at al. Corona generation and deposition of metal nanoparticles on conductive surfaces and their effect on the substrate surface texture and chemistry. Particulate Science and Technology, An International Journal, vol. 22, Issue 4, 2004. 5. F. J. Romay at al. A sonic jet corona ionizer for electrostatic discharge and aerosol neutralization. Aerosol Science and Technology, 20:1, p.p. 31-41, 1994. 6. C.G.Noll Balanced static elimination in variable ion mobility environments. Journal of Electrostatics vol. 49, Issues 3-4, 2000, p.p. 169-194. 7. C.G.Noll at al. Charge-carrier extraction from air and nitrogen gas streams that entrain charge from a radioactive ionizer Journal of Electrostatics vol. 54, Issues 3-4, 2002, p. p.283-291. 8. P.Gefter at al Covering wide areas with ionized gas streams US patent application number 20100925519. Page 11

Page 12

Page 13

Page 14