SOLID PHASE EXTRACTION FOR THE SPECIATION AND PRECONCENTRATION OF Cr (III) AND Cr (VI) IN WATER SAMPLE

Similar documents
Speciation of Cr (III) and Cr (VI) in Water Sample by Spectrophotometry with Cloud Point Extraction

*Author for Correspondence

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

enable measurement. This method separates these isotopes effectively.

Supporting Information

UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2004/2005. March KAA 502 Atomic Spectroscopy.

JOURNAL OF. Flow Injection. Analysis FIA 研究懇談会会誌

Reverse Flow Injection Analysis for Determination of Manganese(II) in Natural Water. Jintana Klamtet

Ion Exchange Determination of Na+ by Displacement and Zn 2+ Using Preconcentration. Reading: Harris pp , 699

Biosorption of aqueous chromium VI by living mycelium of phanerochaete chrysosporium

A New Cation-Exchange Method for Accurate Field Speciation of Hexavalent Chromium

Title Quantitative Analysis of a Solution Containing Cobalt and Copper

Draft Method proposal: determination of glucoheptonic acid (HGA) in fertilizers.

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

Separation and recovery of mangenese- and cobalt catalysts from wastewater of PTA unit

ProPac WCX-10 Columns

Determination of Some Heavy Metals in Real Samples by FAAS after Preconcentration on 4-Nitro-2-(2-nitrophenelazo)phenol

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

METHOD 9035 SULFATE (COLORIMETRIC, AUTOMATED, CHLORANILATE)

Direct Determination of Chromium(lll) and Chromium(VI) with Ion Chromatography Using Direct Current Plasma Emission as Element-Selective Detector*

Removal of Cd (II) and Cr (VI) from Electroplating Wastewater by Coconut Shell

Seawater Extraction Procedure for Trace Metals

METHOD 7199 DETERMINATION OF HEXAVALENT CHROMIUM IN DRINKING WATER, GROUNDWATER AND INDUSTRIAL WASTEWATER EFFLUENTS BY ION CHROMATOGRAPHY

Kenji Narimura, *Katsutoshi Inoue, Keisuke Ohto, Hiroyuki Harada, Hidetaka Kawakita

LEAD(II) AND COBALT(III) HEPTHYLDITHIOCARBAMATES AS NEW COFLOTATION REAGENTS FOR PRECONCENTRATION OF CADMIUM BEFORE ITS ETAAS DETERMINATION

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Glossary of Common Laboratory Terms

URANIUM IN SOIL. Analytical Procedure (2 GRAM SAMPLE) 1. SCOPE

Design, synthesis, and application of chelating polymers for separation and determination of trace and toxic metal ions. A green analytical method*

Application of Selenium Speciation Analysis to Elucidate Limitations with Accepted Total Selenium Methods

TECHNETIUM-99 IN SOIL

Kapil Dev, Rita Pathak, G.N. Rao *

Test Method: CPSC-CH-E

METHOD #: Approved for NPDES and SDWA (Ed. Rev. 1974, 1978) Fluoride, Total (Colorimetric, SPADNS with Bellack Distillation)

Determination of trace anions in concentrated hydrofluoric acid

Analytica Chimica Acta 452 (2002) Received 20 September 2000; received in revised form 14 August 2001; accepted 26 September 2001

TECHNETIUM-99 IN WATER

Removal of Crystal Violet from Aqueous Solution by Activated Biocharfibers. Maria A. Andreou and Ioannis Pashalidis

Spectrophotometric Determination of Anionic Surfactants in River Water with Cationic Azo Dye by Solvent Extraction- Flow Injection Analysis

RECOVERY OF INDIUM FROM SPENT FLAT PANEL DISPLAY WITH SOLVENT-IMPREGNATED RESINS. K. Inoue, M. Nishiura, H. Kawakita, K.Ohto, and H.

THORIUM, PLUTONIUM, AND URANIUM IN WATER

PointH Standard Addition Method for Simultaneous Determination of Zinc (II) and Aluminum (III) Ions

Cu-Creatinine- Metol system

Column Preconcentration and Determination of Cobalt(II) Using Silica Gel Loaded with 1-Nitroso-2-naphthol

Determination of Trace Metals in Waters by FAAS after Enrichment as Metal-HMDTC Complexes Using Solid Phase Extraction

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS

Carbonate content. SCAN-N 32:98 Revised White, green and black liquors and burnt lime sludge

Available online at ScienceDirect. Procedia Environmental Sciences 31 (2016 )

Determination of Chloride, Fluoride, Bromide, Nitrate, Sulphate and Phosphate in Water Sample...

SOUTH AFRICAN NATIONAL STANDARD. Standard test methods for lead in water

Available online Research Article

EXPERIMENT 7. Determination of Sodium by Flame Atomic-Emission Spectroscopy

ICP-OES Application Note Number 35

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

TECHNETIUM-99 IN WATER

Application of Fe 2 O 3 nanoparticles in Heavy Metal Removal

METHOD 9200 NITRATE. 1.2 The applicable range of concentration is 0.1 to 2 mg NO -N per liter. 3 of sample.

Automated Determination of PPQ Levels of Thorium in High Purity Copper

Removal of Cu 2+, Cd 2+, Hg 2+, and Ag + from Industrial Wastewater by Using Thiol-Loaded Silica Gel

Spectrophotometric Evaluation of Stability Constants of Copper, Cobalt, Nickel and Zinc with 2-Thiobarbituric Acid in Aqueous Solution

RegulatoryScience. Elimination of Sodium Chloride Interference on Heavy Metal Analysis in High-Salt Food

12 Nicarbazin Nicarbazin (4,4 -dinitro carbanilid (DNC) and 2-hydroxy-4,6-dimethyl pyrimidine (HDP))

SCIENTIFIC INSTRUMENT NEWS. Introduction. Tsuyoshi Ebina

Chapter 3 Electrochemical methods of Analysis-Potentiometry

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Orderly Arranged Fluorescence Dyes as a Highly Efficient Chemiluminescence Resonance Energy Transfer Probe for Peroxynitrite

9/13/10. Each spectral line is characteristic of an individual energy transition

Sodium Chloride - Analytical Standard

ANALYTICAL SCIENCES OCTOBER 2002, VOL The Japan Society for Analytical Chemistry

Environment Protection Engineering REMOVAL OF HEAVY METAL IONS: COPPER, ZINC AND CHROMIUM FROM WATER ON CHITOSAN BEADS

LEAD (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 500 C

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

PRECONCENTRATION AND EXTRACTION OF COPPER(II) ON ACTIVATED CARBON USING ETHYL-2-QUINOLYL-β(p-CARBOXYPHENYL HYDRAZONE)DIOXO PROPIONATE

Extraction of Ultra Trace Amounts Bismuth in Water Samples Using Cloud Point Extraction with 2-Amino-Cyclopentene-1-Dithiocarboxylic Acid

Chromatographic Methods of Analysis Section - 4 : Ion Exchange Chrom. Prof. Tarek A. Fayed

Research Article Application of Pneumatic Flow Injection-Tandem Spectrometer System for Chromium Speciation

Automated on-line separation preconcentration system for platinum determination by electrothermal atomic absorption spectrometry

ANALYTICAL SCIENCES JUNE 1998, VOL The Japan Society for Analytical Chemistry

Diquat 1,1 -ethylene-2,2 -bipyridium dibromide salt Paraquat 1,1 -dimethyl-4,4 -bipyridium dichloride salt Initial Preparation

DISCLAIMER: This method:

Annex 2 Formaldehyde

Standard Methods for the Examination of Water and Wastewater

Determination of urea in ultrapure water by IC-MS/MS

Development of a Sampling and Analysis Method for the Measurement of Hexavalent Chromium in Ambient Air

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Removal of Nickel ions from Aqueous Solutions on Packed bed of Zeolite NaX

Chapter 4 Materials and Methods

2-Hydroxy-4-n-propoxy-5-bromoacetophenone (HnPBAO) oxime as a gravimetric reagent for Ni(II) and Cu(II) and spectrophotometric study of the complexes

Remember - Ions are more soluble in water than in organic solvents. - Neutrals are more soluble in organic solvents than in water.

International Journal of Pharma and Bio Sciences V1(2)2010 SOLVENT EXTRACTION OF CHROMIUM (VI) FROM MINERAL ACID SOLUTIONS BY TRIBUTYL AMINE

Pelagia Research Library. Spectrophotometric determination of Ametoctradin and in its commercial formulations

Quality Control Procedures for Graphite Furnace AAS using Avanta Software

TKI CU01 V-1.0_EN Cu separation from irradiated targets 01/12/10

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

Determination of Cr(VI) in Water, Waste Water, and Solid Waste Extracts

PHYSICAL CONSTANTS: MELTING POINTS, BOILING POINTS, DENSITY

Comparision of Langmuir and Freundlich Equilibriums in Cr, Cu and Ni Adsorption by Sargassum

Sodium Chloride - Analytical Standard

DRAFT EAST AFRICAN STANDARD

Transcription:

SOLID PHASE EXTRACTION FOR THE SPECIATION AND PRECONCENTRATION OF Cr (III) AND Cr (VI) IN WATER SAMPLE * Maryam Derakhshandeh 1, Jafar Burromandpiroze 1 and Kobra Moteabed 2 1 Department of Chemistry, College of Chemical Engineering, Mahshahr Branch, Islamic Azad University, Mahshahr, Iran 2 Marun Petrochemical Company, Pet. zone, P.O. Box 15815/1513, Mahshahr, Iran *Author for Correspondence ABSTRACT A sensitive and selective method for the preconcentration and speciation of sub μg L 1 levels of chromium species in aqueous solutions. The agarose-based chelating adsorbents with, respectively, iminodiacetic acid (IDA) and an Poly styrene Crosslinked - DVB anion exchanger (Purolite C100), were studied for the separation and preconcentration of Cr(III) and Cr(VI) species in water. Column recoveries of all the adsorbents were plotted against ph, and it was found that at ph 3.0 the IDA adsorbent selectively adsorbs Cr(III), with a 100 ± 1.0% recovery. The Purolite C100 accumulated only Cr(VI) at this ph, again with a recovery of 99.8 ± 1.2%. A dual column system was accordingly designed, using the two adsorbents in tandem, for the separation and preconcentration of the chromium species. The effects of ph, sample flow rate, column length, eluent type, eluent volume, acid concentration and interfering ions on the recoveries of Cr (III) and Cr (VI) were carefully studied. It was shown that by passing test solutions, at ph 3.0; through the dual column system, the two chromium species could be individually collected on the columns, respectively, and eluted, one after the other. A portion of 2 mol L 1 hydrochloric acid was used for elution of each column before final measurement by flame AAS method. A preconcentration factor of 12, a detection limit of 7.7 ± 0.1μg L 1 and a precision expressed as relative standard deviation of 0.4% (at 0.3 mg L 1 ) were achieved for six replicates. Application of the developed method to the determination of chromium species in spiked river and tap water and wastewater samples, from a dye production plant, resulted in excellent agreements with accepted concentrations. Keywords: Water Analysis; Iminodiacetic Acid; Purolite C100; Separation; Agarose Adsorbents; AAS Method; Chromium Speciation INTRODUCTION Speciation, separation and preconcentration of metal ions are of great interest in analytical, industrial and environmental fields of studies. Direct analysis of natural samples can give rise to unreliable results unless a separation step is used before final measurement. In addition, many of the separation And/ or preconcentration techniques result in valuable speciation information. Solid phase extraction by polypropylene columns packed by chelating or ion exchange sorbents has been widely used for this purpose. The usefulness of a solid phase extraction column depends on its functional groups, support material, particle size, etc. Agarose-based adsorbents, due to their hydrophilicity and chemical resistance in a wide ph range of 0 14, have been shown to be excellent support materials for column preconcentration and speciation experiments. Chelating ion exchangers have been frequently used for preconcentratior separation and speciation of metal ions prior to their determination in bot off line and on line modes. Chromium preconcentration and speciation is of great interest from an environmental point of view, because of different toxicities of its species and low concentrations of this element in natural waters. Cr (III) is an important nutrient for humans; the insulin hormone does not function without it. Cr (VI), on the other hand, is known as a poison that causes cancer. A number of different methods have been employed for chromium speciation and/or preconcentration. Among them, column techniques are of great interest. In these methods, usually only one column is used to adsorb one of the chromium species. Hence, the sample must be either oxidized or reduced in order to determine total chromium. Copyright 2014 Centre for Info Bio Technology (CIBTech) 1179

Mondal et al. reported selective retention of Cr (III) and Cr (VI), respectively, by changing the ph of a 2- naphtol-3,6-disulphonic- acid column from 6.5 to 1.5. Marques and co-workers, on the other hand, accumulated both chromium species on an activated alumina column, followed by selective elution by nitric acid and ammonium hydroxide, respectively. Use of a dual column system, in which each species was retained on one column with their respective elution, was first reported by Naghmush et al., (1994). In this method, however, the effluent ph of the first column must be readjusted before it enters the other column, which makes the procedure somewhat complicated. In this work, two different types of adsorbents are studied in an attempt to design a dual column method in which the adsorption ph and other conditions for the two columns are the same, while each column accumulates only one species of chromium. MATERIALS AND METHODS Chemicals and Apparatus Agarose-based chelating adsorbents functionalized by iminodiacetic acid (IDA-Novarose), was gift from Inovata AB (Stockholm, Sweden). Purolite C100, is a high-capacity, based from conventional gel polystyrene sulphonate cation -exchanger resin was obtained from purolite (usa). All other chemicals were purchased from Merck or Fluka. The chemicals were analytical grade and used as they were received. Measurements were performed by a flame AAS instrument (PG 990, UK). Spectrophotometric determination of Cr (VI) was made by a PG T-80 spectrophotometer. For ph determinations, a Metrohm model 827 ph meters with a combined glass electrode was used after calibration against standard Merck buffers. All the dilutions were made by double distilled water, prepared by a Fision (UK) double distiller. Preconcentration columns were 5.6mm i.d. polypropylene tubes with two frits at their bottoms and tops, packed with an adsorbent. A peristaltic pump (EYLA RP- 1000, Japan) was used for pumping solutions through the columns. Methods Stock solutions of Cr (III) were prepared by dissolution of required amounts of Cr (NO 3 ) 3 salts in 0.1M hydrochloric acid and its dilution to volume by the same acid. Cr (VI) stock solutions were prepared in the same way using K 2 Cr 2 O 7 salt. Test solutions and standard solutions for calibration curves were prepared by dilution of the same stocks. Test solutions were prepared by dilution of required volumes of the stocks in an acetate buffer media. The final concentrations of chromium and acetate were usually 0.3 mgl 1 and 0.01 M, respectively. Droplets of 1M hydrochloric acid or sodium hydroxide were used for adjustment of ph before dilution of the solutions to the volume. For packing the columns, suspensions of the adsorbents were pipetted into an empty column with a frit at the bottom. A gentle vacuum was applied for faster settling of the particles before mounting the top frit. The column pretreatment was made by passing 10 ml double distilled water, 10ml 2M hydrochloric acid and 10 ml 0.1M acetate buffer (ph 5.5) through it. Preconcentration and recovery experiments were made, usually, by pumping 40 ml of a buffered (by 0.01M acetate buffer) test solution through a pretreated column with a flow rate of 3.5 4.0 mlmin 1. The column was then washed with a few milliliters of double distilled water and eluted by 6ml 2M hydrochloric acid (unless otherwise stated). The eluate was collected in small capped vessels and analyzed by flame AAS against matched standards. Column length was usually 20mm for the adsorbents. The mahshahr s river and tap water samples were acidified to ph 2 on collection, filtered through a membrane filter (0.45µ), spiked by Cr(III) and Cr(VI), and ph adjusted by the addition of drops of sodium hydroxide before column preconcentration. Waste water from a dye production plant was also acidified on collection and used as a real sample. This sample was filtered, ph adjusted and analyzed as soon as possible after collection. About 40 ml of the field samples were enriched on selected columns and they were eluted by 6ml HCl before measurement. Spectrophotometric determination of Cr (VI) in real samples, for evaluation of the speciation method, was made by addition of diphenylcarbazide in acidic media to the samples, and absorbance determination at 540 nm in accordance with standard procedures. Copyright 2014 Centre for Info Bio Technology (CIBTech) 1180

Capacity measurements for the chelating adsorbents were performed in column mode as reported elsewhere. A 100 ml solution of 100 mgl 1 copper at ph 5.5 was used for saturation of a column before its elution with 2M hydrochloric acid. The capacity for copper was considered as a measure of total active sites of a chelating adsorbent. The detection limit of the system used was calculated from the detection limit of AAS for direct determination of chromium, using ordinary methods, divided by the highest sample preconcentration factor (PF) achieved. All the experiments were performed with at least two and usually three replicates. RESULTS AND DISCUSSION Comparison of the Adsorbents Column recoveries of Cr (III) and Cr (VI) were determined as a function of ph for the two different adsorbents in order to find the most suitable column packing for the purpose of speciation and preconcentration. The adsorbent studied was IDA-Novarose, with a capacity of 92.6 ± 7μmol ml 1 for Cu (II). This adsorbent is negatively charged in the ph range studied and, as expected, does not significantly adsorb Cr (VI) anionic species. Cr (III) shows a quantitative recovery, beginning at ph 3.0 and decreasing gradually with increasing ph. Figures 1 and 2 summarize the results. Purolite C-100 is an anion exchanger with polystyrene sulphonate functional groups. Its recovery for Cr(III) with positive charges is expected to be negligible, but it should efficiently scavenge negatively charged Cr(VI). The results (Figures 1 and 2) confirm these expectations. As shown, the recovery of Cr (VI) on this adsorbent was quantitative in the whole ph range. Cr (III), on the other hand, is not significantly recovered in the ph range of 2 8. The capacity of this adsorbent for Cr(VI) was measured at up to 247 μmol ml 1 under optimized conditions. Compared to the chelating adsorbents studied this adsorbent contained more functional groups per milliliter. It was also observed that Purolite C-100 particles are softer than Novarose sorbents and therefore produced higher backpressures in column. Taking into consideration the results obtained from the recovery experiments, it was decided to use the IDA-Novarose and Purolite C-100 adsorbents to design a dual column system for separation and preconcentration of Cr (III) and Cr (VI). At ph 3.0, the IDA-Novarose selectively adsorbs Cr (III) with no effect on Cr (VI). The Purolite C-100, on the other hand, accumulates only Cr (VI) at the same ph. At ph 3.0, Cr (III) species are positively charged and are adsorbed or chelated efficiently by the negatively charged iminodiacetate functional groups of the IDA-Novarose. Cr (VI), on the other hand, is mainly in the anionic form of HCrO 4 at the same ph and is hold only by the positively charged groups of the Purolite C-100 anion exchanger. Hence, the two columns can be enriched using the same ph and the accumulated analytes may be then eluted one after the other from the columns. Effect of Different Parameters After selection of suitable adsorbents, the effect of different parameters on the accumulation and recovery of Cr (III) and Cr (VI) was studied in order to optimize conditions for achieving the best results. A one-ata-time method was used for this purpose, changing one parameter each time while keeping the others constant. The effect of sample flow rate was the first parameter studied. When the sample flow rate was increased from 2 to 7mlmin 1, the recovery of Cr(III) decreased slightly for the IDA-Novarose, from 100 ± 1.0% to 98.7 ± 1.1%. The sample flow rate had no significant effect on the accumulation of Cr (VI) by Purolite C-100. Higher flow rates were not tested due to high backpressures encountered and some limitations of the peristaltic pump used. Four different types of eluents were tested for elution of the analytes. Six-millilitre portions of 2M HCl or 2M H2SO4 efficiently desorbed both the analytes from the columns. Using nitric acid (2 M) as an eluent for Cr (III) on the IDA adsorbent also resulted in quantitative recoveries. An average value of 82 ± 2% was obtained, however, for triplicate measurements of Cr (VI) recovery from the Purolite C-100 column. The use of an EDTA solution (0.1 M) as eluent resulted in low recoveries of 40 ± 4 and 63 ± 3 for Cr (III) and Cr (VI), respectively, from the adsorbents. Copyright 2014 Centre for Info Bio Technology (CIBTech) 1181

Figure 3 depicts the effect of eluent (HCl) concentration on the recoveries of Cr (III) and Cr (VI) from IDA-Novarose and Purolite C-100 columns, respectively. The results indicate that an efficient elution of the chromium species requires minimum acid concentrations of 1 and 2M, respectively. The effect of eluent volume also was investigated using 2M HCl for elution. As shown in Figure 4, at least 6.0 6.5 ml of acid is required to achieve quantitative recoveries from both columns. Different sample volumes of 40, 60 and 80 ml for enrichment of the columns were tested and no significant decrease in the recovery was observed. All the samples contained the same amount of an analyte, i.e. 0.012 mg Cr (III) or Cr (VI), despite of their different volumes. The recoveries in no case were less than 100 ± 1%. Matrix ions can often affect recovery of an analyte or interfere with its final measurement. Na +, K +,Mg 2+ and Ca 2+ cations and NO 3, PO 4 3, F, Cl and SO 4 2 anions are the most commonly occurring ions in natural waters. Effects of the matrix cations on the recovery of Cr (III) and the matrix anions on the recovery of Cr (VI) were carefully investigated. In each case, at least four different concentrations of the potentially interfering ion were added to the sample and the recovery was determined. The optimum column length for IDA-Novarose and Purolite C-100 was found to be 2.1 and 0.8 cm, respectively. Longer columns increased backpressure, and a shorter column did not scavenge the analyte completely. A study of the effect of acetate buffer concentration resulted in recoveries of 77 ± 2% for Cr (III) and 63 ± 2% for Cr (VI) when an acetate concentration of 0.05M was used. This means that a high acetate or ammonium ion concentration can partly elute the Purolite C-100 or IDA-Novarose columns, respectively, and may be explained by incorporation of an ion exchange mechanism in the adsorption of the analytes. Ammonium acetate concentrations higher than 0.01M were, hence, avoided. It was found that temperature also affects column recoveries by affecting backpressure and, accordingly, sample flow rates. On hot summer days some losses of analytes were observed. It was, therefore, decided to perform all the experiments at a temperature not higher than 25 C. Design of the Dual Column System Decisions regarding the best experimental conditions for the preconcentration and speciation system were based on the results obtained from the parameters study. Table 2 lists the optimized settings for the IDA- Novarose and Purolite C-100 columns. A tandem, dual column system was accordingly designed for the separation and preconcentration of the chromium species. A schematic representation of the system is depicted in Figure 5. In this system, the sample s ph is set at 3.0 and then passed through the system. The first column, containing the IDA-Novarose adsorbent, accumulates Cr (III) with no effect on the Cr (VI) species. The Purolite C-100 column then adsorbs Cr (VI) with no need to readjust the ph. In the elution step, a rotating valve allows the columns to be eluted individually by a similar eluent. Then the eluates are collected in small vessels and analysed later in an offline mode or, alternatively, they can be monitored by a flame AAS instrument in an online flow system. The efficiency of the system was tested first in an offline mode with synthetic standard solutions containing both Cr (III) and Cr (VI) at known concentrations (see Table 3). Quantitative recoveries were obtained for both the analytes. The detection limit for the chromium species was calculated to be 7.7 ± 0.1μg L 1 for a preconcentration factor of 12. The detection limit of the method easily can be reduced further by using a more sensitive analytical technique, such as electrothermal AAS or ICP-MS. The precision of the method was estimated by six times analysis of a mixed Cr (III) and Cr (VI) sample by the speciation system. A precision expressed as relative standard deviation of 0.4% (at 0.3 mg L 1 ) was obtained. To see how the system works for real samples, spiked (with 0.3 mg L 1 chromium species) river water and a wastewater sample from a dye production plant were analysed. Certification of the results was performed by determination of Cr (VI) with a diphenyl carbazide spectrophotometric method and measurement of total chromium by the flame AAS instrument. The Cr (III) concentration then was calculated by difference. The system was also tested for a low concentration sample by preconcentration of a tap water sample spiked by only 50µg L 1 chromium species. The results, as shown in Table 3, indicate a good confirmation between reference and determined concentrations by the designed method with a maximum relative error of only 1.3%.The results are shown in Table 3. Copyright 2014 Centre for Info Bio Technology (CIBTech) 1182

Recovery Recovery Indian Journal of Fundamental and Applied Life Sciences ISSN: 2231 6345 (Online) A t-test indicated no significant difference between the reference and measured values, with a 95% confidence level. It can be concluded that the dual column system can efficiently separate and preconcentrate Cr (III) and Cr (VI) species in water samples. The system is simple and can be easily automated and used in online modes as well. Samples with high ionic strengths or high calcium contents, however, are not recommended to be used with this system due to a risk of some analytes losses. 100 90 80 70 60 50 40 30 20 10 0 IDA-Nov. Purolite c-100 2 3 4 5 6 7 8 ph Figure 1: Percent recovery of Cr(III) from IDA-Novarose and Purolite C-100 adsorbents as a function of ph. Sample volume 40 ml, 0.01M acetate buffer, eluent 6.5 ml 2M HCl, flow rate 4ml min 1, column length 2.0 cm. 120 100 80 60 40 IDA-Nov. Purolite c-100 20 0 2 3 4 5 6 7 8 ph Figure 2: Percent recovery of Cr(VI) from IDA-Novarose and Purolite C-100 adsorbents as a function of ph. Other conditions are as in Figure 1 Copyright 2014 Centre for Info Bio Technology (CIBTech) 1183

Recovery Indian Journal of Fundamental and Applied Life Sciences ISSN: 2231 6345 (Online) 120 100 80 60 IDA-Nov. Purolite c-100 40 20 0 0 0.5 1 1.5 2 2.5 3 3.5 HCl Concentration(M) Figure 3: Percent recoveries of Cr(III) from IDA-Novarose and Cr(VI) from Purolite C-100 as functions of HCl concentration. Other conditions are as in Figure 1 Table 1: Effect of interfering ions on the recovery of Cr(III) and Cr(VI) Analte Interfering ion Maximum tolerance (mg l 1 ) Interfering ion/analyte mole ratio Recovery Cr(III) K + 550 2122 99.6( ±0.8) Na + 400 3014 99.9 (±0.8) Mg 2+ 100 a 713 99.7 (±1.0) Ca 2+ 50 217 99.8 (±0.8) Cr(VI) NO 3 500 1398 99 (±1) PO 4 3 1000 a 1825 100 (±1) F 1000 a 9123 100 (±1) Cl 500 2441 100 (±1) SO 4 2 120 217 99 (±1) Here, the recoveries are reported only when the maximum tolerable amount of an interfering ion is used. Other conditions are as in Figure 1. The numbers in parentheses are standard deviations for triplicate measurements. a The maximum concentration studied. Table 2: The optimum conditions for the preconcentration of Cr (III) and Cr (VI) on the IDA- Novarose and Purolite C-100 columns, respectively Parameter Optimum condition Sample ph 3.0 Flow rate 3ml min 1 Eluent type HCl Eluent concentration 2M Eluent volume 6.5 ml Sample volume 80 ml or less Buffer concentration 0.01M or less Column length (for IDA-Novarose) 2.1 cm Column length (for Purolite C-100 ) 0.8 cm Copyright 2014 Centre for Info Bio Technology (CIBTech) 1184

Recovery Indian Journal of Fundamental and Applied Life Sciences ISSN: 2231 6345 (Online) 120 100 80 IDA-Nov. Purolite c-100 60 40 20 0 0 2 4 6 8 10 12 HCl Volume(mL) Figure 4: Percent recoveries of Cr(III) from IDA-Novarose and Cr(VI) from Purolite C-100 as functions of eluent (2M HCl) volume. Other conditions are as in Figure 1 Table 3: Results obtained for synthetic, natural water and wastewater samples by the designed dual column system in the optimized conditions mentioned in Table 2 Sample Reference values (mg l 1 ) Measured values (mg l 1 ) Relative error (%) Cr(III) Cr(VI) Cr(III) Cr(VI) Cr(III) Cr(VI) Synthetic 0.300 0.300 0.299 (±1.3) 0.299 (±1.2) 0.3 0.3 Spiked Mahshar s river water 0.300 0.300 0.299 (±1.4) 0.299 (±1.3) 0.3 0.3 Wastewater from a dye plant 0.415 (±1.2) 0.300 (±2.1) 0.410 (±1.6) 0.296 (±1.5) 1.2 1.3 Spiked Mahshar s tap water a 0.0500 0.0500 0.0492 (±0.1) 0.0509 (±2.1) 1.6 1.8 The figures in parentheses are relative standard deviations (%) for duplicate measurements. a Chromium concentrations in this case were measured by an electro thermal AAS instrument (Model PG 990 UK) Figure 5: Schematic diagram of the flow system. The peristaltic pump forces a sample, buffer or eluent through the columns. The valve (V) allows separate elution of the columns for their final measurement by the flame AAS method Copyright 2014 Centre for Info Bio Technology (CIBTech) 1185

ACKNOWLEDGEMENT We are grateful for the financial support from the Mahshahr Branch Research Council,Islamic Azad University. REFERENCES Alonso EV, de Torres AG and Pavone JMC (2001). Flow injection on-line electrothermal atomic absorption spectrometry. Talanta 55 219. Bag H, Turker AR, Lale M and Tunceli A (2000). Separation and speciation of Cr(III) and Cr(VI) with saccharomyces cerevisiae immobilized on sepiolite and determination of both species in water by FAAS. Talanta 51 895. Crompton TR (1997). The Analysis of Natural Water (Oxford University Press) New York 1. Hirata S, Honda K, Shikino O, Norihiro M and Aihara M (2000). Determination of chromium(iii) and total chromium in seawater by on-line column preconcentration inductively coupled plasma mass spectrometry. Spectrochimica Acta Part B: Atomic Spectroscopy 55 1089. Hashemi P and Olin Å (1997). Equilibrium and kinetic properties of a fast iminodiacetate based chelating ion exchange and its incorporation in a FIA-ICP-AES System. Talanta 44 1037. Hashemi P, Noresson B and Olin Å (1999). Properties of a high capacity IDA-Novarose adsorbent and its application in a flow system. Talanta 49 825. Manzoori JL, Sorouraddin MH and Shemirani F (1995). Chromium speciation by a surfactant-coated alumina micro column using electro thermal atomic absorption spectrometry. Talanta 42 1151. Marques MJ, Morales-Rubio A, Salvador A and de la Guardia M (2001). Chromium speciation using activated alumina microcolumns and sequential injection analysis-flame atomic absorption spectrometry. Talanta 53 1229. Mollah CBS (1997). Speciation of Chromium(vi) and Chromium(iii) using pneumatically. Assisted Electrospray Masss Spectrometry, Journal of Analytical Atomic Spectrometry 12 503. Mondal BC, Das D and Das AK (2002). Synthesis and characterization of a new resin functionalized with 2-naphthol 3,6-disulphonic acid and its application for the speciation of chromium in natural water- B.C.Mondal. Talanta 56 145. Naghmush AM, Pyrznska K and Trojanowicz M (1994). Flame AAS determination of lead in water with flow-injection preconcentration and speciation using functionalized cellulose sorbent. Analytica Chimica Acta 288 247. Nielsen S and Hansene EH (1998). Selective flow-injection quantification of ultra-trace amounts of Cr(VI) via on line complexation and preconcentration with APDC followed by determination by electrothermal atomic absorption spectrometry. Analytica Chimica Acta 366 163. Rao TP, Karthikeyan S and Iyer CSP (1998). Speciative determination of chromium (VI) and chromium(iii) using flow-injection on-line preconcentration and flame atomic-absorption spectrometric detection. Analytica Chimica Acta 369 69. Willie N, Sturgeon RE and Berman SS (1983). Determination of Total Chromium in seawater by Graphite Furnace Atomic Absorption Spectrometry. Analytica Chimica Acta 55 981. Copyright 2014 Centre for Info Bio Technology (CIBTech) 1186