TABLE 2 MW: TABLE 1 CAS: TABLE 2 RTECS: TABLE 2. METHOD: 1450, Issue 2 EVALUATION: PARTIAL Issue 1: 15 February 1984 Issue 2: 15 August 1994

Similar documents
METHOD: 1403, Issue 3 EVALUATION: FULL Issue 1: 15 August 1990 Issue 3: 15 March 2003

HYDROCARBONS, AROMATIC 1501

METHYLTIN CHLORIDES 5526

HYDROGEN CYANIDE 6017

FORMALDEHYDE by GC 2541

ORGANOPHOSPHORUS PESTICIDES 5600

VINYL CHLORIDE. Recommended by NIOSH, partially evaluated by OSHA Laboratory.

METHYL ETHYL KETONE PEROXIDE 3508

ALDEHYDES, SCREENING 2539

Method for the determination of 1,3-butadiene

ACETIC AND FORMIC ACIDS IN WORKPLACE ATMOSPHERES ppm for Acetic Acid, CH 3 COOH

Media blank result for a single-section sampler (e.g., membrane filter). Media blank result for back section of a sampler.

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

STANDARD OPERATING PROCEDURES

Methods for the determination of vinyl chloride

Real-Time Detection: From Gisclard et al.: A Simple Device for Air Analysis. AIHA Quarterly, 14(1):23-25 (1953)

1. A gas chromatograph equipped with flame ionization detection and a computing integrator.

Method for the determination of dimethyl sulfate

METHOD: 2532, Issue 1 EVALUATION: PARTIAL Issue 1: 15 August PRECISION ( r

METHOTREXATE mg/m 3 (arbitrary). There is no OSHA PEL or AGGIH TLV for

METHOD: 3601, Issue 1 EVALUATION: PARTIAL Issue 1: 15 March NAMES & SYNONYMS: manganous ethylenebis(dithiocarbamic acid), Manzate; Dithane M-22

Validation of. Tetrahydrofuran Using. SKC Passive Sampler Cat. No

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

TECHNICAL TEMEPHOS. 1. Specification. Full specification WHO/SIT/19.R4 Revised 10 December Description

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Date 02/24/96 Page 1 Revison 4.0 OKLAHOMA DEPARTMENT OF ENVIRONMENTAL QUALITY METHODS 8020/8015 (MODIFIED) GASOLINE RANGE ORGANICS (GRO)

Introduction to IH Analytical Chemistry

NCASI METHOD CI/SG/PULP-94.02

A STUDY OF VOLATILE ORGANIC CARBON POLLUTION ON A UNIVERSITY CAMPUS DUE TO TRAFFIC

British American Tobacco Group Research & Development. Method - Determination of phenols in mainstream cigarette smoke

Analytical Methods for Detection and Identification

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Methods for the determination of ethylene oxide

H 3 CO H 3 CO S CH 3

Chemistry Gas Chromatography: Separation of Volatile Organics

PA-DEP 3686, Rev. 1. Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID)

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

Headspace Technology for GC and GC/MS: Features, benefits & applications

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography 1

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

Industrial Hygiene Report

Hexane isomers (except n-hexane) and methylcyclopentane

VOLATILE ACIDS by Ion Chromatography (Hydrogen Chloride, Hydrogen Bromide, Nitric Acid)

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

BUTYL ALCOHOL in urine by GC-FID Code GC05510

Supporting Information

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

Journal of Chemical and Pharmaceutical Research

LEAD by Flame AAS 7082

Anethole. Gas chromatograhpy determination of trans-anethole in Spirit srinks of viti-vinicultural origin

Standard Operating Procedure for the Analysis of Dissolved Inorganic Carbon CCAL 21A.1

THEORETICAL DETERMINATION OF THE SAMPLING RATES OF DIFFUSION SAMPLERS FOR VOCS AND ALDEHYDES

CIPAC. CIPAC Free relevant impurities methods:

This method describes the identification of the following prohibited colorants in cosmetic products:

CHROMIUM, HEXAVALENT 7605 by Ion Chromatography

APPENDIX A TO PART 136 METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER METHOD 609 NITROAROMATICS AND ISOPHORONE

Magnitudes of Back Diffusion During Long-Term Diffusive Sampling of Volatile Organic Compounds Using Carbotrap and Chromosorb 106

Sulfotepp impurities in Chlorpyrifos EC formulations

Method for Characterization of Gum Rosin by Capillary Gas Chromatography

637. Thiamethoxam. HPLC method

Determination of Volatile Substances Proof of Food Adulteration

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

METHOD 3520C CONTINUOUS LIQUID-LIQUID EXTRACTION

Raw Material Finished product By product Exposure standards Length of shift Physical environment

Citric Acid Analysis L-6-1. MOISTURE (Karl Fischer)

METHYLISOBUTYLKETONE (4-methyl-2 pentanone) IN URINE BY GC/MS Headspace Code GC10510

METHYLETHYLKETONE (M.E.K.) IN URINE BY GC/MS in head space Code GC10010

GAS CHROMATOGRAPHY (GC)

Muliple Gas#3 plus Sulfur GC Configuration

Ondansetron Hydrochloride Tablets

Research Report. Validation of Methyl Methacrylate (MMA) using SKC Passive Sampler Abstract

METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS

METHOD 3520B CONTINUOUS LIQUID-LIQUID EXTRACTION

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Uncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Method 615. The Determination of Chlorinated Herbicides in Municipal and Industrial Wastewater

TO-15 Checklist Determination of VOCs in Air by GC-MS

MEDROXYPROGESTERONE INJECTION

METHOD 3665 SULFURIC ACID/PERMANGANATE CLEANUP

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Corn Sugar (crude & refined) Analysis F MOISTURE (Karl Fischer)

LAP-013. Procedure Title: Date: 6/28/96. Author: Raymond Ruiz and Tina Ehrman ISSUE DATE: 8/26/96 SUPERSEDES: 11/01/94.

Method 633. The Determination of Organonitrogen Pesticides in Municipal and Industrial

ADVANTAME (TENTATIVE)

METHOD 9035 SULFATE (COLORIMETRIC, AUTOMATED, CHLORANILATE)

*Correspondence to:

British American Tobacco Group Research & Development. Method - Determination of ammonia in mainstream smoke

Determination of Polymer Modifier in Asphalt

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

GB/T Translated English of Chinese Standard: GB/T

TETRACHLOROETHYLENE IN URINE BY GC/MS Headspace Code GC15010

Electronic Supplementary Material Experimentally Validated Mathematical Model of Analyte Uptake by Permeation Passive Samplers

TRICHLOROETHYLENE IN URINE BY GC/MS Headspace Code GC16110

Experiment DE: Part II Fisher Esterification and Identification of an Unknown Alcohol

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

Transcription:

ESTERS I 1450 TABLE 2 MW: TABLE 1 CAS: TABLE 2 RTECS: TABLE 2 METHOD: 1450, Issue 2 EVALUATION: PARTIAL Issue 1: 15 February 1984 Issue 2: 15 August 1994 OSHA : Table 2 PROPERTIES: Table 2 NIOSH: Table 2 ACGIH: Table 2 COMPOUNDS: n-amyl acetate t-butyl acetate isobutyl acetate sec-amyl acetate (synonyms 2-ethoxyethyl acetate methyl isoamyl acetate n-butyl acetate ethyl acrylate in Table 2) n-propyl acetate sec-butyl acetate isoamyl acetate SAMPLER: FLOW RATE: SAMPLING SOLID SORBENT TUBE (coconut shell charcoal, 100 mg/50 mg)) 0.01 to 0.2 L/min VOL-MIN 1 L @ OSHA PEL -MAX 10 L SHIPMENT: refrigerated SAMPLE STABILITY: not determined BLANKS: 2 to 10 field blanks per set ACCURACY RANGE STUDIED: 0.5 to 2X OSHA PEL [1] (10-L samples) BIAS: See EVALUATION OF METHOD OVERALL PRECISION (S rt ): 0.05 to 0.09; see EVALUATION OF METHOD MEASUREMENT TECHNIQUE: GAS CHROMATOGRAPHY, FID ANALYTE: compounds above DESORPTION: INJECTION VOLUME: 1 ml CS 2, 30 min 5 L TEMPERATURE - INJECTION: 200-225 C - DETECTOR: 250-300 C - COLUMN: 60 to 100 C (Table 1) CARRIER GAS: N 2 or He, 30 ml/min COLUMN: stainless steel, 3 m x 3-mm, 5% FFAP on 100/120 mesh Chromosorb WHP CALIBRATION: solutions of compounds in CS 2 RANGE: Table 1 ESTIMATED LOD: 0.02 mg per sample [2] PRECISION ( r ): 0.02 [1] ACCURACY: See EVALUATION OF METHOD APPLICABILITY: This method can be used for simultaneous analysis of 2 or more substances by changing the gas chromatographic conditions (e.g., temperature programming). High humidity greatly reduces sampler capacity and breakthrough volume. INTERFERENCES: None identified. Alternate columns (e.g., 10% SP-1000 on Chromosorb WHP) may be useful if interferences are encountered. OTHER METHODS: This method combines and replaces Methods S31, S32, S35, S37, S41, S44 through S48, and S51 [3]. Method 1457 (Ethyl Acetate) gives a capillary column procedure which may be useful for the esters in this method.

EST ERS 1: MET HOD 1450, Iss ue 2, date d 15 Au gust 1994 - Page 2 of 6 REAGENTS: 1. Eluent: Carbon disulfide* (chromatographic grade) with 0.1% (v/v) benzene or 1% (v/v) tridecane, dodecane, undecane or other suitable internal standard 2. Analyte, reagent grade 3. Helium, purified. 4. Hydrogen, prepurified. 5. Air, compressed, filtered. * See SPECIAL PRECAUTIONS. EQUIPMENT: 1. Sampler: glass tube, 7 cm long, 6-mm OD, 4-mm ID, flame-sealed ends, containing two sections of activated (600 C) coconut shell charcoal (front = 100 mg; back = 50 mg) separated by a 2-mm urethane foam plug. A silylated glass wool plug precedes the front section and a 3- mm urethane foam plug follows the back section. Pressure drop across the tube at 1 L/min airflow m ust be les s than 3.4 kpa. Tubes are commercially available. 2. Perso nal sam pling pump, 0.01 to 0.2 L/min, with flexible connecting tubing. 4. Refrigerant, bagged ("Blue Ice," or equivalent). 4. Gas chromatograph, FID, integrator and column (page 1450-1). 5. Vials, glass, 2-mL, PTFE-lined crimp caps. 6. Syringe, 10- L, readable to 0.1 L, 25-, 50- and 100- L 7. Volumetric flasks, 10 8. Pipet, volumetric, 1-mL, with pipet bulb. SPECIAL PRECAUTIONS: Carbon disulfide is toxic and an acute fire and explosion hazard (flash point = 30 C); w ork with it only in a hood. SAMPLING: 1. Calibrate each personal sampling pump with a representative sampler in line. 2. Break the ends of the sam pler imm ediately before sampling. Attach sampler to personal sampling pump with flexible tubing. 3. Sample at an accurately known flow rate between 0.01 and 0.2 L/min for a total sample size of 1 to 10 L. 4. Cap the samplers with plastic (not rubber) caps and pack securely for shipment with bagged refrigeran t. SAMPLE PREPARATION 5. Place the front and back sorbent sections of the sampler tube in separate vials. Discard the glass wool and foam plugs. 6. Add 1.0 ml eluent to each vial. A ttach crim p cap to e ach vial. 7. Allow to stand 30 min with occasional agitation. NOTE: The de sorption efficiency of 2-ethox yethyl acetate ha s been found to decreas e with the resident time of the desorbed solution with charcoal [4]. After 30 min. desorption transfer the supernatant solution of 2-ethoxyethyl acetate to a clean 2-mL vial and seal with a crimp cap.

EST ERS 1: MET HOD 1450, Iss ue 2, date d 15 Au gust 1994 - Page 3 of 6 CALIBRATION AND QUALITY CONTROL: 8. Calibrate daily with at least six working standards over the range 0.02 to 10 mg analyte per sample. a. Add known amounts of analyte to eluent in 10-mL volumetric flasks and dilute to the mark. b. Analyze together with sam ples and blanks (steps 11 and 12). c. Prepare calibration graph (ratio of peak area of analyte to peak area of internal standard vs. mg analyte). 9. Determine desorption efficiency (DE) at least once for each lot of charcoal used for sampling in the calibration range (step 8). Prepare three tubes at each of five concentrations plus three media blanks. a. Remove and discard back sorbent section of a media blank sampler. b. Inject a known amount of analyte directly onto front sorbent section with a microliter syringe. c. Cap the tube. Allow to stand overn ight. d. Desorb (steps 5 through 7) and analyze together with working standards (steps 11 and 12). e. Prepare a graph of DE vs. mg analyte recovered. 10. Analyze three quality control blind spikes and three analyst spikes to insure that the calibration graph and DE graph are in control. MEASUREMENT: 11. Set gas chromatograph according to manufacturer's recommendations and to conditions given on page 1450-1. Inject sample aliquot with autosampler, or manually using solvent flush technique. NOTE: If peak are a is above the line ar range of the working standards, dilute with eluent, reanalyze and apply the appropriate dilution factor in calculations. 12. Measure peak area. Divide the peak area of analyte by the peak area of internal standard on the same chromatogram CALCULATIONS: 13. Determine the mass, mg (corrected for DE) of analyte found in the sample front (W f ) and back (W b ) sorbent sections, and in the average m edia blank front (B f ) and back (B b ) sorbent sections. NOTE: If W b > W f /10, report breakthrough and possible sample loss. 14. Calculate concentration, C, of analyte in the air volume sampled, V (L): EVALUATION OF METHOD: The methods listed below were issued on December 6, 1974, except for S51, which was issued on January 17, 1975 [2]. Atmospheres of each compound were generated in dry air by calibrated syringe drive and 10-L air samp les were taken [1]. Collection efficiency in humid air and sam ple stability were not tested. Spiked samplers were used to study measurement precision and desorption efficiency (DE). Results are as follows:

EST ERS 1: MET HOD 1450, Iss ue 2, date d 15 Au gust 1994 - Page 4 of 6 Overall Measurement Compound Method [3] Range, mg/m 3 Breakthrough 1 (<) Bias Accuracy % rt (± %) Range, mg per sample DE 2 r n-amyl acetate S51 208-871 34.2 0.3 0.051 10.3 2.6-10 0.87 0.019 sec-amyl acetate S31 349-1460 20.9-4.1 0.071 15.4 3.3-13 0.93 0.012 n-butyl acetate S47 352-1475 20.5 0.3 0.069 10.4 3.5-14 0.94 0.020 sec-butyl acetate S46 478-2005 16.5-2.4 0.054 11.3 4.7-19 0.93 0.017 t-butyl acetate S32 424-1780 14.3-8.6 0.091 22.2 4.7-19 0.94 0.039 2-ethoxyethyl acetate S41 262-1100 34.6 9.6 0.062 19.4 2.5-11 0.79 0.024 ethyl acrylate S35 50-210 >45-7.1 0.054 15.7 0.5-2 0.95 0.029 isoamyl acetate S45 208-874 32.3-7.1 0.056 15.6 2.6-10 0.91 0.010 isobutyl acetate S44 306-1280 21.5 1.8 0.065 11.1 3.5-14 0.94 0.016 methyl isoamyl acetate S37 143-601 >45-2.6 0.058 11.6 1.5-6 0.93 0.021 n-propyl acetate S48 384-1610 17.9 6.9 0.056 16.8 4.2-17 0.93 0.018 1 5% breakthrough, 0.2 L/min, at high end of concentration range in dry air. 2 Averaged over mass range shown. REFERENCES: [1] Documentation of the NIOSH Validation Tests, U.S. Department of Health, Education, and Welfare, Publ. (NIOS H) 77-185 (1977). [2] User check, UBTL, NIOS H Sequence #4121-N (unpublished, November 15, 1983). [3] NIOSH Manual of Analytical Methods, 2nd ed., V. 2, U.S. Department of Health, Education, and Welfare, Publ. (NIOS H) 77-157-B (1977). [4] Corelson, D., SRI, Menlo Park, CA., Personal communication with NIOSH (1988). METHOD REVISED BY: Robert W. Kurimo, NIOSH/DPSE; methods originally validated under NIOSH Contract CDC-99-74-45.

EST ERS 1: MET HOD 1450, Iss ue 2, date d 15 Au gust 1994 - Page 5 of 6 Table 1. Operational details. Measurement M.W. Working range Range, mg Column Compound mg/m3 = 1 ppm @ NTP mg/m 3 @ 10 L per sample Temperature, C MW mg/m 3 = 1 ppm n-amyl acetate 130.18 5.32 50 to 1575 0.5 to 16 90 sec-amyl acetate 130.18 5.32 65 to 1950 0.65 to 20 95 n-butyl acetate 116.16 4.75 71 to 2130 0.7 to 21 90 sec-butyl acetate 116.16 4.75 95 to 2850 1 to 28 60 t-butyl acetate 116.16 4.75 95 to 2850 1 to 28 70 2-ethoxyethyl acetate 132.16 5.40 54 to 1620 0.5 to 16 100 ethyl acrylate 100.11 4.09 10 to 300 0.1 to 3 70 isoamyl acetate 130.18 5.32 50 to 1575 0.5 to 16 90 isobutyl acetate 116.16 4.75 70 to 2100 0.7 to 21 70 methyl isoamyl acetate 144.22 5.90 30 to 900 0.3 to 9 90 n-propyl acetate 102.13 4.18 84 to 2520 0.8 to 25 70

EST ERS 1: MET HOD 1450, Iss ue 2, date d 15 Au gust 1994 - Page 6 of 6 Table 2. General information Compound, Formula, and RTECS Synonyms OSHA/NIOSH/ACGIH, ppm BP, C VP @ 20 C, kpa (mm Hg) Liquid Density, g/ml @ 20 C n-amy l acetate CH 3 COO(CH 2 ) 4 CH 3 ; C 7 H 14 O 2 AJ1925000 acetic acid 1-pentan ol ester; CAS #628-63 -7 TWA (STEL) 100/100/100 149 0.5(4) 0.876 sec-am yl acetate CH 3 COOCHCH 3 (CH 2 ) 2 CH 3 ; C 7 H 14 O 2 AJ2100000 n-butyl ace tate CH 3 COO(CH 2 ) 3 CH 3 ; C 6 H 12 O 2 AF7350000 sec-buty l acetate CH 3 COOCH(CH 3 )CH 2 CH 3 ; C 6 H 12 O 2 AF7380000 t-butyl aceta te CH 3 COOC(CH 3 ) 3 ; C 6 H 12 O 2 AF7400000 2-ethoxy ethyl ace tate CH 3 COO(CH 2 ) 2 OCH 2 CH 3 ; C 6 H 12 O 3 KK8225000 ethyl acryla te CH 2 =CHCOOCH 2 CH 3 ; C 5 H 8 O 2 AT0700000 isoam yl acetate CH 3 COO(CH 2 ) 2 CH(CH 3 ) 2 ; C 7 H 14 O 2 NS9800000 isobutyl ac etate CH 3 COOCH 2 CH(CH 3 ) 2 ; C 6 H 12 O 2 AI4025000 methy l isoamy l acetate CH 3 COOCH(CH 3 )CH 2 CH(CH 3 ) 2 ; C 8 H 16 O 2 SA7525000 n-propyl a cetate CH 3 COO(CH 2 ) 2 CH 3 : C 5 H 10 O 2 AJ3675000 a Skin b Carcinogen acetic acid 2-pentan ol ester; CAS #626-38 -0 acetic acid butyl ester; CAS #123-86 -4 acetic acid 1-methyl propyl ester; CAS #105-4 6-4 acetic acid 1, 1-dime thylethyl es ter; CAS #540-88 -5 Cellosolve acetate; acetic acid ethylene glycol monoethyl ether ester; CAS 111-15-9 2-propenoic acid ethyl ester; CAS #140-8 8-5 acetic acid 3-meth yl-1-butan ol ester; CAS #123-92 -2 acetic acid isobutyl ester; CAS #110-19-0 acetic acid 4-meth yl-2-penta nol ester; 1,3-dimethyl butyl acetate; "sec-hexyl acetate"; C AS #1 08-84-9 acetic acid n-propyl es ter; CAS #109-60 -4 125/125/125 134 0.9(7) 0.866 150/150(200)/150(200) 126 1.3(10) 0.883 200/200/200 112 1.3(10) 0.865 200/200/200 98 not ava ilable 0.867 100 a /0.5 a /5 a 156 0.3(2) 0.973 25 a /4 LOQ b /5 ab (15 ppm) 99 3.9(30) 0.923 100/100/100 142 0.5(4) 0.876 150/150/150 117 1.7(13) 0.871 50/50/50 146 0.5(3.8) 0.858 200/200 (250)/200 (250) 102 3.3(25) 0.890