at Oak Ridge National Laboratory.

Similar documents
Available online at ScienceDirect. Physics Procedia 69 (2015 )

Int. Coaf. Physics of Nuclear Science and Technology

Neutron collimator design of neutron radiography based on the BNCT facility arxiv: v1 [physics.ins-det] 3 May 2013

Performance characteristics of the tomography setup at the PSI NEUTRA thermal neutron radiography facility

Neutron and Gamma Ray Imaging for Nuclear Materials Identification

THE use of neutrons in imaging has been on-going since

FUNDAMENTAL PARAMETER METHOD USING SCATTERING X-RAYS IN X-RAY FLUORESCENCE ANALYSIS

Simulated Results for Neutron Radiations Shielding Using Monte Carlo C.E. Okon *1, I. O. Akpan 2 *1 School of Physics & Astronomy,

Utilization of Egyptian Research Reactor and modes of collaboration

ANALYSIS OF LOW MASS ABSORPTION MATERIALS USING GLANCING INCIDENCE X-RAY DIFFRACTION

Time Correlation Measurements of Heavily Shielded Uranium Metal. Oak Ridge National Laboratory, 1 Bethel Valley Road, Oak Ridge, TN 37831

MCSHAPE: A MONTE CARLO CODE FOR SIMULATION OF POLARIZED PHOTON TRANSPORT

RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA

Convertible source system of thermal neutron and X-ray at Hokkaido University electron linac facility

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

New Neutron-Induced Cross-Section Measurements for Weak s-process Studies

Neutronic Design and Analyses of A New Core- Moderator Assembly and Neutron Beam Ports for The Penn State Breazeale Reactor

NEUTRONIC ANALYSIS STUDIES OF THE SPALLATION TARGET WINDOW FOR A GAS COOLED ADS CONCEPT.

USA HTR NEUTRONIC CHARACTERIZATION OF THE SAFARI-1 MATERIAL TESTING REACTOR

ASTM E545 TUTORIAL ON PROPER IMAGE QUALITY INDICATOR USAGE

IMAGING OF HETEROGENEOUS MATERIALS BY. P. Staples, T. H. Prettyman, and J. Lestone

THE SIMULATION OF THE CODED NEUTRON SOURCE PHASE CONTRAST IMAGING

COMMISSIONING TESTS OF THE NEW NEUTRON RADIOGRAPHY FACILITY AT THE LVR-15 REACTOR ABSTRACT

DEVELOPMENT OF A NEW POSITRON LIFETIME SPECTROSCOPY TECHNIQUE FOR DEFECT CHARACTERIZATION IN THICK MATERIALS

Shielded Scintillator for Neutron Characterization

Seeing inside lead-acid batteries using neutron imaging. J. M. Campillo-Robles, D. Goonetilleke, N. Sharma, D. Soler, U. Garbe, P.

Chem 481 Lecture Material 4/22/09

Modeling of Li-Ion-Batteries to Optimize the Results Gained by Neutron Imaging

Determination of the boron content in polyethylene samples using the reactor Orphée

PoS(FNDA2006)033. Radiography Using Fission Neutrons. Thomas Bücherl. Christoph Lierse von Gostomski

An Optimized Gamma-ray Densitometry Tool for Oil Products Determination

Monte Carlo Calculations Using MCNP4B for an Optimal Shielding Design. of a 14-MeV Neutron Source * James C. Liu and Tony T. Ng

Low dimensional neutron moderators for enhanced source brightness

Simulation program for reinforced concrete tomography with gamma-rays

NEW CORRECTION PROCEDURE FOR X-RAY SPECTROSCOPIC FLUORESCENCE DATA: SIMULATIONS AND EXPERIMENT

Modern neutron imaging: Radiography, Tomography, dynamic and phase contrast imaging with neutrons

THE SLOWPOKE-2 NUCLEAR REACTOR AT THE ROYAL MILITARY COLLEGE OF CANADA: APPLICATIONS FOR THE CANADIAN ARMED FORCES

Measurements with the new PHE Neutron Survey Instrument

Available online at ScienceDirect. Physics Procedia 69 (2015 )

INFLUENCE OF GROWTH INTERRUPTION ON THE FORMATION OF SOLID-STATE INTERFACES

Characteristics of Filtered Neutron Beam Energy Spectra at Dalat Reactor

Calibration of the GNU and HSREM neutron survey instruments

1 General information and technical data of TRIGA RC-1 reactor

STRESS ANALYSIS USING BREMSSTRAHLUNG RADIATION

INDUSTRIAL RADIOGRAPHY

FACTORS AFFECTING IN-LINE PHASE CONTRAST IMAGING WITH A LABORATORY MICROFOCUS X-RAY SOURCE

Training program for x-ray inspection film (RT)

THE IMPORTANCE OF THE SPECIMEN DISPLACEMENT CORRECTION IN RIETVELD PATTERN FITTING WITH SYMMETRIC REFLECTION-OPTICS DIFFRACTION DATA

Validation of the MCNP computational model for neutron flux distribution with the neutron activation analysis measurement

Proposed model for PGAA at TRIGA IPR- R1 reactor of CDTN

Neutronics Experiments for ITER at JAERI/FNS

Institute of Atomic Energy POLATOM OTWOCK-SWIERK POLAND. Irradiations of HEU targets in MARIA RR for Mo-99 production. G.

Use of Imaging for Nuclear Material Control and Accountability

MATERIALS CHARACTERIZATION USING A NOVEL SIMULTANEOUS NEAR-INFRARED/X-RAY DIFFRACTION INSTRUMENT

BWXT Y-12 Y-12. A BWXT/Bechtel Enterprise SMALL, PORTABLE, LIGHTWEIGHT DT NEUTRON GENERATOR FOR USE WITH NMIS

Researchers at the University of Missouri-Columbia have designed a triple crystal

Nuclear Cross-Section Measurements at the Manuel Lujan Jr. Neutron Scattering Center

Nanostructured alumina materials characterization study

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

J. T. Mihalczo. P. 0. Box 2008

Neutron Imaging at Spallation Neutron Sources

Nuclear Data Measurements at the RPI LINAC

Proton Radiography. Chapter Two

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

in the pinch. This paper describes the computer modeling behind the shielding design of a

GA A22722 CENTRAL THOMSON SCATTERING UPGRADE ON DIII D

The Attenuation of Neutrons in Barite Concrete

Investigation Of The Effects Of Variation Of Neutron Source-Detector Distance On The Emitted Neutron Dose Equivalent

Applications of MCBEND

Quartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays

Reactor radiation skyshine calculations with TRIPOLI-4 code for Baikal-1 experiments

Redacted for Privacy

Name Date Class NUCLEAR RADIATION. alpha particle beta particle gamma ray

ACTIVATION ANALYSIS OF DECOMISSIONING OPERATIONS FOR RESEARCH REACTORS

Reactors and Fuels. Allen G. Croff Oak Ridge National Laboratory (ret.) NNSA/DOE Nevada Support Facility 232 Energy Way Las Vegas, NV

A Two-Dimensional Point-Kernel Model for Dose Calculations in a Glovebox Array. D. E. Kornreich and D. E. Dooley

Neutronic studies on a pulsed thermal neutron source based on the Be(p,n) reaction by using a compact proton accelerator

Calculations of Photoneutrons from Varian Clinac Accelerators and Their Transmissions in Materials*

Progress in Nuclear Science and Technology, Volume 6,


REALIZATION OF AN ASYMMETRIC MULTILAYER X-RAY MIRROR

Simulation for radiography of neutron and X-ray as well as the shielding of radioactive rays

CLASSIFICATION AND IMAGING OF SPENT NUCLEAR FUEL DRY CASKS USING COSMIC RAY MUONS

CALIBRATION OF SCINTILLATION DETECTORS USING A DT GENERATOR Jarrod D. Edwards, Sara A. Pozzi, and John T. Mihalczo

: Y/LB-16,056 OAK RIDGE Y-12 PLANT

Rad T 290 Worksheet 2

AN ABSTRACT OF THE THESIS OF. Kimberly Ropon for the degree of Master of Science in Radiation Health Physics presented on June 12, 2006.

A Monte Carlo Simulation for Estimating of the Flux in a Novel Neutron Activation System using 252 Cf Source

Low Coherence Vibration Insensitive Fizeau Interferometer

Quantitative Assessment of Scattering Contributions in MeV-Industrial X-ray Computed Tomography

Calculations of Neutron Yield and Gamma Rays Intensity by GEANT4

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

(Tandem Collimators for the Tangential GammaRay Spectrometer - KM6T-TC)

1. General information and technical data of TAPIRO research reactor

MONTE-CARLO SIMULATIONS OF TIME- RESOLVED, OPTICAL READOUT DETECTOR for PULSED, FAST-NEUTRON TRANSMISSION SPECTROSCOPY (PFNTS)

A COMPACT X-RAY SPECTROMETER WITH MULTI-CAPILLARY X-RAY LENS AND FLAT CRYSTALS

Design of the testing set-up for a nuclear fuel rod by neutron radiography at CARR

SLAC National Accelerator Laboratory FACET & TEST BEAM FACILITIES PROPOSAL

M.Cagnazzo Atominstitut, Vienna University of Technology Stadionallee 2, 1020 Wien, Austria

1. What would be the dose rate of two curies of 60Co with combined energies of 2500 kev given off 100% of the time?

Transcription:

361 Designs for Neutron Radiography at Oak Ridge National Laboratory and Computed Tomography Dudley A. Raine lipv4, Camden R. Hubbard, Paul M. Whaley, and Michael C. Wright3 Oak Ridge National Laboratory 1 Bethel Valley Road PO Box 2008 MS 6064 Oak Ridge, TN 3783 l-6064 (423) 574-3 197 Abstract The capability to perform neutron radiography and computed tomography is being developed at Oak Ridge National Laboratory. The facility will be located at the High Flux Isotope Reactor (HFIR), which has one of the highest steady state neutron fluxes of any reactor in the world. Neutrons are quite penetrating in most engineering materials and can be useful to detect internal flaws and features. Hydrogen atoms, such as in a hydrocarbon fuel, lubricant or a metal hydride, are relatively opaque to neutron transmission. Thus, neutron based tomography or radiography is ideal to image the presence of hydrogenous materials within engineering structures. The Monte Carlo N- Particle transport code (MCNP), versions 4A and 4B, has been used extensively in the design phase of the facility to predict and optimize the operating characteristics, and to ensure the safety of personnel working in and around the blockhouse. The HFIR source flux provides unparalleled opportunity for future upgrades, including real-time radiography for analysis of dynamic processes. A novel tomography detector has been designed using optical fibers and digital technology to provide a large dynamic range for tomographic reconstructions. Film radiography is also available for high resolution imaging applicatons. This paper summarizes the results of the design phase of this facility and the potential benefits to science and industry. This research was sponsored by the Oak Ridge National Laboratory Laboratory Directed Research and Development Fund. Oak Ridge National Laboratory is managed by Lockheed Martin Energy Research Corp. For the U.S. Department of Energy under contract number DE-AC05960R22464. Dudley Raine was supported by an appointment to the Oak Ridge National Laboratory Postdoctoral Research Associates Program administered jointly by Oak Ridge National Laboratory and the Oak Ridge Institute for Science and Education. I Metals and Ceramics Division Research Reactors Division 3 Instrmentation and Controls Division 4 E-mail: rained@oml.gov

This document was presented at the Denver X-ray Conference (DXC) on Applications of X-ray Analysis. Sponsored by the International Centre for Diffraction Data (ICDD). This document is provided by ICDD in cooperation with the authors and presenters of the DXC for the express purpose of educating the scientific community. All copyrights for the document are retained by ICDD. Usage is restricted for the purposes of education and scientific research. DXC Website www.dxcicdd.com ICDD Website - www.icdd.com

362 Introduction The nuclear interactions of neutrons with materials are different from the electromagnetic and photoelectric x-ray interactions, and as such can be used in complementary or unique ways for the nondestructive examination of materials. While x-ray interactions are dominated by the photoelectric effect, and thus dependent on the atomic number of the element, neutron interactions with matter are dependent on the nuclear state of the target nuclei. The result is that while the interaction probability for x-rays generally increases steadily with the atomic number of the target atom, there is no proportionality to atomic number which governs the interaction probability for a neutron. Neighboring elements and even different isotopes of the same element can have very different neutron attenuation coefficients. One application of the uniqueness of neutron interactions is in the detection of hydrogenous material within engineering materials and structures. Most metals typically used for manufacturing purposes are readily penetrated by neutrons, surpassing even the maximum depth of high energy x-rays, while hydrogen atoms have a high probability of scattering neutrons out of the incident beam. The concept for the Neutron Computed Tomography and Radiography Facility (NCTRF) was proposed as one part of a Laboratory Directed Research and Development project aimed at adding new capabilities to the neutron scattering and diffraction programs already in place at ORNL. Film radiography would be available for high resolution applications, while a novel computed tomography system would be developed for characterizing the internal structure of objects. The applications for such a facility include void and inclusion detection in castings and weldments, hydrocarbon location, water migration in materials (percolation, absorption, etc.), and nondestructive detection of corrosion and manufacturing defects. Design Goals The key issues in the design of any facility for neutron imaging include the neutron flux, the L/D ratio, the thermal-to-fast neutron flux ratio (also called the cadmium ratio), Neutror Source 4 I Moderator Gamma Filter 4 Neutron Beam -------- _/_------ Figure 1. A schematic of a typical neutron radiography facility. Fil; / Conversion Screen the thermal neutron-to-gamma ratio, the flux uniformity, and the imaging method. The parameters most important to the quality of the image data are the L/D ratio, the ratio of the length of the collimator to the diameter of the aperture, a measure of the divergence of the beam, and an indicator of the amount of blurring that will be present in the resulting images, and the thermal neutron-to-gamma ratio, an indicator of

363 hlfl COtiTRUL O&E Figure 2. Drawings showing the layout of the HFIR core and the four HB and EF facilities, plan view (left), vertical section (right). the relative contribution of the gammas to the image data. The layout of a typical neutron radiography facility is shown in Figure 1. Optimization is usually constrained by the source type, as well as by the means available to bring the neutrons from the source to the desired location. The goal of this work was to optimize the beam parameters and provide the maximum possible flux to permit high resolution imaging with exceptional dynamic range. Due to the large amount of beryllium present around the core and the indirect path that neutrons must follow to enter the experiment room at the end of EF- 1, the neutron flux is expected to be highly thermalized and should produce a beam with a very high cadmium ratio and a thermal neutron-to-gamma ratio greater than 1~10~ n/cm2-mr. Based on the geometry of the system, it is expected that the beam will have an L/D ratio greater than 100 and, due to the flux distribution shaping which can be done with the lead/bismuth filter, provide a reasonably flat flux profile. Helium will also be used as a fill gas to limit the beam attenuation from air scattering and cleanup plates made with cadmium and borated aluminum have been designed to remove any scattered neutrons or neutrons that are not well collimated from the source. The High Flux Isotope Reactor has numerous beam facilities available for research. There are four horizontal beam (HB) tubes, primarily used for neutron scattering experiments, and four engineering facility (EF) tubes, which are slant tubes passing by the core at the periphery of the beryllium reflector (Figure 2). These EF tubes are inclined at a forty-nine degree angle from the horizontal plane and enter one floor above the reactor and HB experiment hall. The angle of the EF tubes has limited these beams to certain specialized experiments and activation analysis work. In October, 1995, a Laboratory Directed Research and Development proposal was submitted with one part devoted to installing a neutron computed tomography and radiography facility at HFIR. Since

364 Figure 3. The conceptual design for the Neutron Computed Tomography and Radiography Facility. all of the HB tubes were already in use, the decision was made to use one of the available EF slant tubes (Figure 3). The choice provided the maximum flexibility for optimizing the key features listed above without interfering with the operation of any of the established facilities. Monte Carlo Models Monte Carlo models were used to optimize the parameters important to the NCTRF. existing model of the High Flux Isotope Reactor was modified to include transport through the EF tube that was selected for the NCTRF. Initial runs were performed with MCNP to benchmark the measured flux levels recorded in the EF tube against various other known values in other regions of the core. These results were compared with prior models and experimental data to verify their accuracy. The initial runs were then used to generate surface source files which could be used in subsequent calculations.. This greatly reduced the time required to generate adequate statistics for the tallies at the end of the beam tube. The first simulations run constituted a sensitivity study to determine the optimum position and shape of the beryllium scattering block in the EF- 1 thimble which would maximize the delivered flux at the exit point of the collimator. The ideal position for the beryllium block was found to be with the top of the block slightly above or right at the centerline of the core while the effect of shaping the end of the beryllium was found to be negligible. These simulations showed that this configuration would deliver an unfiltered beam flux at the exit plane of the collimator of approximately 4~10~ n/cm2-s with a neutron-to-gamma ratio of 2~10~ n/cm*-mr. A bismuth lens was then added to shape and filter the beam, and it was shown that the collimator design could produce a ten inch diameter beam with a flux around 2~10~ n/cm -s with a variation of less than five percent in intensity from the center to the edge of the beam, and a neutron-to-gamma ratio of 4x lo6 n/cm2-mr. However, further simulations in the experiment room indicated that the required shield An

365 Figure 4. A diagram of the MCNP4B model of the collimator and details of the scattering block, the lead/bismuth filter and pressure boundary, and the cleanup plates. for such a beam would exceed the floor loading limit. Modifications were made to the collimator design based on the allowable floor loading (without reinforcement) and the available resources for shielding. The filter was changed to a lead/bismuth combination with the lead part of the filter closest to the core. Shielding and beam strength were balanced with a filter thickness that gave a flux at the collimator exit of approximately 1~10~ n/cm*-s, as it was determined that the floor would support an adequate amount of shielding to contain a beam of this strength. The beam flux distribution was shaped by placing a small hemisphere of bismuth at the top of the filter to provide uniformity. This had the added benefit of increasing the neutron-to-gamma ratio at the exit point of the collimator to lx lo7 n/cm*-mr. r A diagram of the collimator model is shown in Figure 4. 0 1 2 3 4 I I I I I feet Figure 5. The layout of the Neutron Computed Tomography and Radiography Facility. Prototype Facility The NCTRF is expected to be available for testing and users in early 1998. Two different imaging methods will be available for research applications in the prototype facility. Film radiography will be performed for high resolution applications using a gadolinium conversion screen and aluminum film cassette. The tomography detector is nearing completion and will have 96 pixel elements, each a one by one millimeter square Li6F/ZnS scintillator cube coupled to an optic fiber, which will carry the

366 signal from the detection array to a diode array detector outside the blockhouse. Each element will have its own 32-bit counter to provide superior dynamic range. The design of the facility provides for a fast shutter for accurate exposure control, as well as a slow shutter and shielded turntable to permit personnel access without the necessity of filling the collimator with water (Figure 5). The sample positioning device is a large 4-axis unit designed to hold and maneuver an object weighing up to 100 kg at the required 49 degree tilt of the beam with a movement range of twelve inches along each axis and a full 360 degree rotation capability (Figure 6) The table was designed with the specific requirement that none of its components would extend above the plane of the sample mounting table. Figure 6. The sample positioning system for the Conclusions Neutron Computed Tomography and Radiography A new Neutron Computed Facility. Tomography and Radiography Facility is under construction at the High Flux Isotope Reactor at Oak Ridge National Laboratory. The facility will provide routine film radiography for high resolution applications and will utilize a novel fiber- based detector system for neutron computed tomography. The design of the collimator also provides a straightforward avenue for increasing the beam flux once shielding issues are resolved by reinforcing the floor. The Monte Carlo N-Particle transport code (MCNP) has been an invaluable tool in the analysis of the beam characteristics and instrument performance. This experience will provide significant insights for the design and construction of future facilities and instruments. References J. F. Briesmeister, Ed., MCNP - A General Monte Carlo N-Particle Transport Code, Version 4A, LA-12625, 1993.