The role of LSD spikes in safeguarding nuclear reprocessing plants R Wellum, Y Aregbe, A Verbruggen, S Richter

Similar documents
Preparation and Certification of IRMM1027k, Large-Sized Dried (LSD) spike

Preparation and Certification of IRMM-081a and IRMM-086 Spike Isotopic Reference Materials

CERTIFICATION REPORT Preparation and Certification of Large-Sized Dried (LSD) Spike IRMM-1027r

Preparation and Certification of Large-Sized Dried (LSD) Spike IRMM-1027o

CERTIFICATION REPORT. Preparation and certification of a new batch of 242 Pu spike: IRMM-049e

2. QUALITY CONTROL IN MASS SPECTROMETRY

NUCLEAR CERTIFIED REFERENCE MATERIALS 2018

EUROPEAN COMMISSION Directorate General Joint Research Centre IRMM NUCLEAR CERTIFIED REFERENCE MATERIALS 2015

Preparation and Certification of IRMM-075. A. Verbruggen, A. Alonso, R. Eykens, F. Kehoe, H. Kühn, S. Richter, R. Wellum, Y.

Joint Research Centre (JRC)

Certification Report. REIMEP 18 Inter-Laboratory Comparison for the Measurement of Uranium Isotopic Ratios in Nitric Acid Solution

ITU-Nuclear Safeguards and Security Unit

CERTIFICATION REPORT. Certification of 244 Pu spike reference material: IRMM-042a

Microparticle Reference Materials for Particle Analysis in Nuclear Safeguards Production & Characterisation

Looking Forward through the Past: Status of the United States Nuclear Safeguards Reference Material Program at New Brunswick Laboratory

Determination of plutonium isotopes in spent nuclear fuel using thermal ionization mass spectrometry (TI-MS) and alpha spectrometry

CERTIFICATION REPORT

Library of uranium and plutonium reference spectra Introduction

IAEA stable isotope reference materials: addressing the needs of atmospheric greenhouse gas monitoring.

Preparation of High Purity Plutonium Oxide for Radiochemistry Instrument Calibration Standards and Working Standards

NUCLE A R FORENSIC S INTERN ATION A L TECHNIC A L WORK ING GROUP ITWG GUIDELINE THERMAL IONISATION MASS SPECTROMETRY (TIMS)

Mercury Determination in Lichen, BCR-482, Using the QuickTrace M-7600 CVAAS Mercury Analyzer

Certificate of analysis Certified reference material code: CRM-00-GTX1&4

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

On-line Monitoring of Water during Reference Material Production by AOTF-NIR Spectrometry

NUCLE A R FORENSIC S INTERN ATION A L TECHNIC A L WORK ING GROUP ITWG GUIDELINE ON ELEMENTAL ASSAY U TITRATION

Validation of Cristallini Sampling Method for UF 6 by High Precision Double-Spike Measurements

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

Examples of Method Validation Studies Conducted in Different Economies

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

ACCURATE QUANTIFICATION OF RADIOACTIVE MATERIALS BY X-RAY FLUORESCENCE: GALLIUM IN PLUTONIUM METAL

Keywords: Safeguards, Destructive Analysis, Environmental Sampling

The analysis of particles of nuclear material finding the proverbial needle in a hay stack

Particle Analysis of Environmental Swipe Samples

High Precision Nondestructive Assay to Complement DA. H.O. Menlove, M.T. Swinhoe, and J.B. Marlow Los Alamos National Laboratory

Isotope Dilution Mass Spectrometry

The Uncertainty of Reference Standards

Glossary of Common Laboratory Terms

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Certificate of analysis Certified reference material code: CRM-00-NEO

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

International Atomic Energy Agency

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

CERTIFICATE OF. Single Analyte Mass Spec Solution ± 0.1 µg/ml g/ml (measured at 20 ± 4 ºC)

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3165 Lot Number: EDTA NIST SRM 928 Lot Number: 928

What is measurement uncertainty?

Th- 234 U model ages of some uranium standard reference materials

Evaluation of the n( 235 U)/n( 238 U) isotope ratio measurements in a set of uranium samples by thermal ionization mass spectrometry

IAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES

Determination of Uranium, Plutonium, Neodymium, Gadolinium and Their Isotopes in UO 2 -Gd 2 O 3 Spent Nuclear Fuels

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Single Analyte Custom Grade Solution ± 4 µg/ml g/ml (measured at 20 ± 1 ºC) EDTA NIST SRM 928 Lot Number: 928

An introduction to Neutron Resonance Densitometry (Short Summary)

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

Single Analyte Mass Spec Solution ± µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT#

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3163 Lot Number:

Single Analyte Custom Grade Solution. CGWH2O1 M2-W H2O µg/ml ea: Tungsten Ammonium Metatungstate

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

URANIUM IN SOIL. Analytical Procedure (2 GRAM SAMPLE) 1. SCOPE

St. John s College High School Mr. Trubic AP Midterm Review Packet 1

Determination of isotopic composition and concentration of uranium and boron by thermal ionization mass spectrometric isotopic dilution technique

Uncertainty in Measurement of Isotope Ratios by Multi-Collector Mass Spectrometry

Bulk Analysis of Environmental Swipe Samples

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3103a Lot Number:

CERTIFICATE OF. Single Analyte Custom Grade Solution g/ml (measured at 20 ± 4 ºC) Graviametric NIST SRM Lot Number: See Sec. 4.

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3122 Lot Number:

LSUF Update on Organically Bound Tritium Standard project. Arvic Harms. 5 May 2004

Certificate of Analysis

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Purity Determination of Acetaldehyde in an Acetaldehyde Certified Reference Material

Comparability and Traceability Point of view from a metrological institute

Determination Spectrometry. of Serum Glucose by Isotope Dilution Mass. National Chemical Laboratory for Industry, Tsukuba, Ibaraki 305

Single Analyte Custom Grade Solution ± 4 µg/ml g/ml (measured at 20 ± 1 ºC) Acidimetric NIST SRM 84L Lot Number: 84L

Certificate of Analysis

The Status Report of Plutonium Management in Japan

A basic introduction to reference materials. POPs Strategy

NICKEL-63/59 IN WATER

Near Real Time Accountancy at JNC-1. Tokai Japan

Sodium Chloride - Analytical Standard

Sulfotepp impurities in Chlorpyrifos EC formulations

AGE DETERMINATION OF HIGHLY ENRICHED URANIUM

ANALYSIS CERTIFICATE OF 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Certified Reference Material - Certificate of Analysis

Single Analyte Mass Spec Solution ± µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT# Calculated See Sec. 4.

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3112a Lot Number: Cr3

VALIDATION OF IQ3 MEASUREMENTS FOR HIGH-DENSITY LOW-ENRICHED-URANIUM WASTE DRUMS AT PELINDABA

REFERENCE MATERIALS

Certified Reference Material - Certificate of Analysis

ANALYSIS CERTIFICATE OF 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

PARAMETERISATION OF FISSION NEUTRON SPECTRA (TRIGA REACTOR) FOR NEUTRON ACTIVATION WITHOUT THE USED OF STANDARD

Single Analyte Mass Spec Solution ± 0.60 µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT# Calculated See Sec. 4.

Determination of Ar molar mass for the Boltzmann constant. Inseok Yang, Jin Bok Lee, Jin Seog Kim Korea Research Institute of Standards and Science

CERTIFICATE OF. Single Analyte Custom Grade Solution. ICP Assay NIST SRM 3120a Lot Number: Calculated NIST SRM Lot Number: See Sec. 4.

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3162a Lot Number:

The Current Situation of Plutonium Management in Japan

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Certificate of Analysis

Transcription:

The role of LSD spikes in safeguarding nuclear reprocessing plants R Wellum, Y Aregbe, A Verbruggen, S Richter Institute for Reference Materials and Measurements (IRMM) Geel, Belgium http://www.irmm.jrc.be http://www.jrc.ec.europa.eu 1

Introduction 1. Background 2. Historical progress 3. Present status 4. Problems and future development 2

Basic considerations LSD spikes are classical spikes used for measuring the isotope amount content of U and Pu in mainly spent nuclear fuel solutions by isotope dilution mass-spectrometry (IDMS) Special features mg size of the spikes so that the dissolver solution does not need dilution before spiking 239 Pu and 235 U are the spikes used at present: the isotopes measured in the sample are 240 Pu and 238 U The 235 U is diluted to 20% with a certified nat U material To measure the amount of U and Pu total concentration, separate measurements of the isotopic ratios relative to the 240 Pu and the 238 U 3

Why these two spike isotopes? Availability 239 Pu is available as a certified metal at > 95% enrichment 235 U and nat U are available for purchase as high purity certified metals Other isotopes do not provide advantages or are not available easily as certified gram-sized quantities 4

Historical development IRMM (De Bièvre) was one of the first institutes to propagate the use of LSD spikes support program to the IAEA (1980) The first spikes proposed were metals an 20% isotopic enriched uranium and a Pu/Gd/Nd alloy 5

Metal spikes Metals had advantages in handling and in the chemistry after adding the sample (reduction) but they needed specialist knowledge to make to a high standard, were difficult to prove homogeneity (Pu) and especially for the Pu alloy needed additional certification Production halted at IRMM around 2000 6

LSD spikes at IRMM These are prepared by dissolving a primary 239 Pu metal (e.g. CETAMA MP2) and an enriched 235 U metal plus a natural U metal to form the needed 20% enrichment The materials are dissolved in ca. 3 kg 3M HNO 3 to form a homogeneous solution, ca. 0.6 mg/g 239 Pu and 18 mg/g U ( 3.7 mg/g 235 U) After drying in 2.5g batches at low temperature, a solution of cellulose acetate butyrate is added to each vial and dried down on the spike to keep it in place during storage and transport 7

Spike amounts Uranium (20% enriched) = 18.5 mg/g solution 235 U = 3.6 mg/g solution = 11 mg per spike ampoule Pu (> 95% enriched 239 Pu) = 0.6 mg/g solution 239 Pu = 1.5 mg per spike ampoule 8

Transport and stability The dried nitrates are not stable over time and tend to flake off. For this reason the first batches of the LSD spikes (1027a 1027e) were covered with tetrahydrofuran, which was dried down onto the spike. This covering was very stable, but not always easy to dissolve under commercial conditions. A substitute material cellulose acetate butyrate was chosen and is used at present 9

Calculate amounts of U and Pu metals LSD spike process Typical metals and amounts: 2g MP2 43g EC101 and 11g CRM- 116 WI: 0000 0.0000788 U-IDMS on IRMM-027h Mother solution Weigh Pu metal 0.0000787 0.0000786 U mol/g solution 0.0000785 0.0000784 0.0000783 Dissolve Pu metal Clean and Weigh U metal(s) 0.0000782 0.0000781 0.0000780 Gravimetric MAT260 Conv MAT262-TE1 MAT262-TE2 MAT262-TE3 Dissolve U metal(s) Make solution up to weight with 5M HNO3 Verify U and Pu isotopics and amount content PR/0074 PR/0075 PR/0076 PR/0077 10

verification ok? If NO then remeasure 2nd verification ok? If NO then stop procedure Aliquot into vials Dry at low temperature Prepare 10% solution of CAB in acetone Add organic solution and dry Cap and seal Verify U and Pu amount contents PR/0074 PR/0075 PR/0076 PR/0077 Verification ok? If NO then remeasure Verification ok? If NO then stop procedure CERTIFY 11

Verification Solution is verified for isotope content : 6 independent samples, spiked with e.g. IRMM- 046b ( 233 U + 242 Pu)and separately checked for isotopic ratios: 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, 242 Pu/ 239 Pu; 234 U/ 238 U, 235 U/ 238 U, 236 U/ 238 U After ampouling, a randomly selected set across the sequence are taken and again the isotope contents are measured after spiking with IRMM-046b 12

13

14

Traceability The isotope concentrations in the final LSD spike are derived from: a) The weights of metals dissolved and weight of final solution b) The certified purities of the metals c) The certified isotopic content of the metals This allows the direct measurement of U and Pu content in a sample by IDMS in a single traceability step 15

Isotope Dilution Mass-spectrometry Sample + spike measurement LSD certificate IDMS LSD certificate: amounts LSD certificate: ratios Sample measurement RM calibration Isotopics RM cal Sample isotopic measurements Main Isotope content Uncertainty contributions 16

Isotope Dilution Mass-spectrometry RM calibration Amount main isotope (from IDMS) Sample isotopic measurements Main isotope content Isotope calibration Sample measurement Isotope contents 17

Isotope dilution with LSD spike Each measurement is built on a foundation of a reference material = the LSD spike 18

Do we need repeated measurements? Not needed One well-controlled measurement is sufficient in principle Extra measurements bring little improvement to the uncertainty Needed Extra measurements increase the trust Mistakes / blunders Deceit (!) Measurements must be under QM and transparent 19

Do we need LSD spikes with very low uncertainties? Yes - when values of the isotope contents with the lowest measured uncertainties are required Yes when the results are being compared with measured or calculated results done elsewhere on the same sample No when a difference between internal samples or input/output of a process are is made Start process End 20

Use of one spike for comparison measurements Taking a spiked sample and measuring subsamples always gives results that agree well. Why? Sample problems are eliminated A large part of the measured uncertainty coming from the spike is present in each measurement. Large degree of correlation, therefore lower apparent scatter 21

Practical problems: future development The development of LSD spikes is still on-going Deposition methods and stability Different ratios U/Pu (MOX fuel) Alternative starting materials linked to more flexible application setups 22

Deposition methods Present method is not fool-proof (< 100% yield) Different types of vials? At least partially metals used? 20% U metal Different covering / higher temperature treatment / addition of other inert materials? Use of robot deposition can increase throughput and increase reliability 23

U/Pu ratio The present U/Pu ratio (25:1) is a compromise A lower ratio is maybe required for MOX fuels Ratio is always defined by the ability to measure by mass-spectrometry Separate spikes for U and Pu possible, but: An excess of uranium seems to stabilize the Pu deposit: more work needs to be done on this 24

Alternative sources of materials Use of primary metals for U and Pu is justified for essential applications of the spikes Limited supply in medium/long-term Spikes made from U/Pu mixtures (e.g. starting as oxides) need to be certified against reference materials Consequence is slightly higher uncertainties Easier to obtain materials 25