Convertible source system of thermal neutron and X-ray at Hokkaido University electron linac facility

Similar documents
Status report of CPHS and neutron activities at Tsinghua University

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Neutronics Experiments for ITER at JAERI/FNS

Neutronic Design on a Small Accelerator based 7 Li (p, n) Neutron Source for Neutron Scattering Experiments

MONTE-CARLO SIMULATIONS OF TIME- RESOLVED, OPTICAL READOUT DETECTOR for PULSED, FAST-NEUTRON TRANSMISSION SPECTROSCOPY (PFNTS)

Neutronic studies on a pulsed thermal neutron source based on the Be(p,n) reaction by using a compact proton accelerator

Precision neutron flux measurement with a neutron beam monitor

Measurements of Neutron Total and Capture Cross Sections at the TOF spectrometers of the Moscow Meson Factory

Available online at ScienceDirect. Physics Procedia 69 (2015 )

Measurement of activation of helium gas by 238 U beam irradiation at about 11 A MeV

Journal of Radiation Protection and Research

neutron building Project Title: Moderator design of RANS2 and investigating of radiation equivalent dose for Name: Sheng Wang

Simulation and design of a transportable and compact neutron source based radiography system for industrial applications

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

anti-compton BGO detector

Experimental neutron capture data of 58 Ni from the CERN n TOF facility

Since the beam from the JNC linac is a very high current, low energy beam, energy loss induced in the material irradiated by the beam becomes very lar

1.E Neutron Energy (MeV)

New Neutron-Induced Cross-Section Measurements for Weak s-process Studies

arxiv:astro-ph/ v1 4 Sep 2001

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

Progress in Nuclear Science and Technology, Volume 6,

Status of Pulsed Neutron Facility in Korea

Optimization studies of photo-neutron production in high-z metallic targets using high energy electron beam for ADS and transmutation

THE INSTALLATION FOR EXPERIMENTAL NEUTRON SPECTRA RESEARCH IN REACTOR MATERIALS COMPOSITIONS Hliustin D.V. Institute for Nuclear Research, Moscow,

Shielded Scintillator for Neutron Characterization

Induced photonuclear interaction by Rhodotron-TT MeV electron beam

Measurement of induced radioactivity in air and water for medical accelerators

Utilization of Variable Energy Radio-Frequency Quadrupole Linear Accelerator Systems.

Simulation for radiography of neutron and X-ray as well as the shielding of radioactive rays

AMOR the time-of-flight neutron reflectometer at SINQ/PSI

A gas-filled calorimeter for high intensity beam environments

Recent Activities on Neutron Calibration Fields at FRS of JAERI

A Proposal of Nuclear Materials Detection and Inspection Systems in Heavily Shielded Suspicious Objects by Non-destructive Manner.

Comparison with simulations to experimental data for photoneutron reactions using SPring-8 Injector

EEE4106Z Radiation Interactions & Detection

Contrabands detection with a low energy electron linac driven photoneutron source

Neutron facilities and generation. Rob McQueeney, Ames Laboratory and Iowa State University

FISSILE MATERIALS DETECTION VIA NEUTRON DIFFERENTIAL DIE-AWAY TECHNIQUE

PHYSICS HIGHER LEVEL

Mass Yield Distribution in the Photon-induced Fission of 232 Th, 238 U, nat Pb, and 209 Bi

48 K. B. Korotchenko, Yu. L. Pivovarov, Y. Takabayashi where n is the number of quantum states, L is the normalization length (N = 1 for axial channel

PoS(FNDA2006)033. Radiography Using Fission Neutrons. Thomas Bücherl. Christoph Lierse von Gostomski

Reactor & Spallation Neutron Sources

The ISIS Penning H - SPS and Diagnostic Developments at RAL

The scanning microbeam PIXE analysis facility at NIRS

Vibration-Free Pulse Tube Cryocooler System for Gravitational Wave Detectors I

at Oak Ridge National Laboratory.

1 Electrons are emitted from a metal surface when it is illuminated with suitable electromagnetic radiation. ...[1]

Present and Future of Fission at n_tof

Status of J-PARC Transmutation Experimental Facility

BENCHMARK EXPERIMENT OF NEUTRON RESONANCE SCATTERING MODELS IN MONTE CARLO CODES

Experiment objectives: measure the ratio of Planck s constant to the electron charge h/e using the photoelectric effect.

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

JURONG JUNIOR COLLEGE J2 H1 Physics (2011) 1 Light of wavelength 436 nm is used to illuminate the surface of a piece of clean sodium metal in vacuum.

DESIGN AND CONSTRUCTION OF LOW ENERGY ELECTRON ACCELERATORS AT SINP MSU

High quantum efficiency S-20 photocathodes for photon counting applications

Beam Extraction by the Laser Charge Exchange Method Using the 3-MeV LINAC in J-PARC )

Construction of the energy-resolved neutron imaging system RADEN in J-PARC MLF

LAAPD Performance Measurements in Liquid Xenon

Neutrons production on the IPHI accelerator for the validation of the design of the compact neutron source SONATE.

FXA UNIT G485 Module X-Rays. Candidates should be able to : I = I 0 e -μx

CHAPTER 12 TEST REVIEW

Title Neutron Beam at J-PARC/MLF/BL09. Kino, Koichi; Yonemura, Masao; Kiya. Citation Physics Procedia (2015), 69:

Name the region of the electromagnetic radiation emitted by the laser. ...

MEASUREMENT OF TEMPORAL RESOLUTION AND DETECTION EFFICIENCY OF X-RAY STREAK CAMERA BY SINGLE PHOTON IMAGES

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Proposal for a neutron imaging station at n TOF EAR2

This paper should be understood as an extended version of a talk given at the

[2] (b) An electron is accelerated from rest through a potential difference of 300 V.

Physics 126 Practice Exam #4 Professor Siegel

Los Alamos National Laboratory Facility Review

(i) Show that the energy of a single photon is about 3 x J.

INTRODUCTION Strained Silicon Monochromator Magnesium Housing Windows for Monochromator Shutter and Collimator Fission Detector HOPG Monochromator

Measurement of the n_tof beam profile in the second experimental area (EAR2) using a silicon detector

Shielding calculations for the design of new Beamlines at ALBA Synchrotron

Radiation Protection At Synchrotron Radiation Facilities

Quantitative Assessment of Scattering Contributions in MeV-Industrial X-ray Computed Tomography

solenoid and time projection chamber for neutron lifetime measurement LINA

Atomization. In Flame Emission

Total kinetic energy and fragment mass distributions from fission of Th-232 and U-233

Energy response for high-energy neutrons of multi-functional electronic personal dosemeter

He-3 Neutron Detectors

ATOMIC WORLD P.1. ejected photoelectrons. current amplifier. photomultiplier tube (PMT)

Performance characteristics of the tomography setup at the PSI NEUTRA thermal neutron radiography facility

Generation of Neutron Beam with the Cylindrical Discharge type Fusion

What do we know from GCSE?

Development of portable neutron generators based on pinch and plasma focus discharges 1

for (n,f) of MAs 1. Introduction

An introduction to Neutron Resonance Densitometry (Short Summary)

The European XFEL in Hamburg: Status and beamlines design

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

WAVES AND PARTICLES. (c)

SCANNING OF CARGO CONTAINERS BY GAMMA-RAY AND FAST NEUTRON RADIOGRAPHY

Generating a multi-line neutron beam using an electron Linac and a U-filter

Chapter 10: Wave Properties of Particles

The GBAR experiment. Dirk van der Werf

Irradiation by Ionizing Radiation Comparison of Ebeam, Xray with Gamma

Developments for the FEL user facility

Estimate of Photonuclear Reaction in a Medical Linear Accelerator Using a Water-Equivalent Phantom

Transcription:

IL NUOVO CIMENTO 38 C (2015) 187 DOI 10.1393/ncc/i2015-15187-9 Colloquia: UCANS-V Convertible source system of thermal neutron and X-ray at Hokkaido University electron linac facility T. Kamiyama( ), K. Y. Hara, H. Taira( )andh. Sato Faculty of Engineering, Hokkaido University - Sapporo 060-8628, Japan received 22 February 2016 Summary. The convertible source system for the neutron and the X-ray imagings was installed in the 45 MeV electron linear accelerator facility at Hokkaido University. The source system is very useful for a complementary imaging. The imaging measurements for a sample were performed with both s by using a vacuum tube type image intensifier. The enhanced contrast was obtained from the dataset of the radiograms measured with the neutron and X-ray s. PACS 07.85.Fv X-andγ-ray sources, mirrors, gratings, and detectors. PACS 28.20.Pr Neutron imaging; neutron tomography. PACS 29.25.Dz Neutron source. PACS 87.59.B- Radiography. 1. Introduction Complementary usage of neutron and X-ray imaging is expected to extend the applicable fields in nondestructive radiography [1-3]. Different cross sections of object for each give images with different information. The conventional neutron radiography has been generally carried out at the reactor facility [4]. On the other hand, the X-ray radiography is often carried out in relatively accessible devices. Therefore, many cases of the complementary radiography take place separately in different lines. However, the imagings under different experimental conditions, such as the object and detector positions or the detector type, are not expedient for the reasonable comparison of their radiograms. Fortunately, at electron accelerator-based radiation sources it is possible to obtain neutrons and X-rays relatively easily. Furthermore, higher energy X-rays can be obtainable with the accelerator-based X-ray source, reaching a penetration length comparable to neutrons. Because of these advantages, an electron ( ) E-mail: takashik@qe.eng.hokudai.ac.jp (corresponding author) ( ) Present address: Hokkaido University of Education, Sapporo 002-8502, Japan. Creative Commons Attribution 4.0 License (http://creativecommons.org/licenses/by/4.0) 1

2 T. KAMIYAMA et al. lectron linear accelerator Modulator room Control room Thermal neutron & x-ray source Cold neutron source Sample & Detector Concrete Experiment room Boron resin Graphite reflector Boron resin Neutron production target Polyethylene moderator Beam line 44 cm Up-and-down stage X-ray production target Fig. 1. Schematic view of the electron linear accelerator facility at Hokkaido University. The inset presents the convertible source system of thermal neutron and X-ray. accelerator-based convertible source system for neutrons and X-rays has been installed at Hokkaido University facility. In this paper, we explain about the configuration of the source system, and show the first result of the complementary radiography with this system. 2. Convertible source system A schematic view of the 45 MeV electron linear accelerator facility at Hokkaido University is shown in fig. 1. A convertible source system of thermal neutron and X- ray was newly installed on a center line in 2014. As shown in the inset of fig. 1, the source system mainly consists of two production targets, a polyethylene moderator, graphite reflectors, lead, boron-resin s. We can choice the alternative of neutron and X-ray sources by remote control when the positions of the targets with respect to the electron axis are changed by moving up (or down) a stage, where the switching time is several minutes. The source system, therefore, allows us to do imaging measurements using both s without a change of sample and detector positions. 2. 1. X-ray source. The cross-sectional view of the X-ray source is shown in fig. 2. The X-ray production target is a copper plate with a thickness of 4 mm that is tilted at 60 X-ray production target Water-cooling dump Neutron production target Polyethylene moderator X-ray Graphite reflector Thermal neutron Fig. 2. Cross-sectional views of the X-ray and neutron production targets.

CONVERTIBLE SOURCE SYSTEM OF THERMAL NEUTRON AND X-RAY ETC. 3 Intensity [a.u.] 10-4 10-5 10-6 10-7 10-8 10-2 10-1 10 0 10 1 E γ [MeV] Intensity [a.u.] 10 2 10 1 10 0 10-1 10-2 10-3 10-4 10-5 10-6 10-7 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 10 0 10 1 E n [MeV] Fig. 3. Calculated energy distributions of the X-ray and neutron s. with respect to the electron axis. Bremsstrahlung photons are generated by hitting the copper plate with the 9 MeV electron and then extracted to the experimental room as the X-ray in the direction perpendicular to the electron axis. For suppressing neutron backgrounds in the X-ray, the energy of electron is set below the threshold of the 63,65 Cu(γ,n) reactions. The energy distribution of the X-ray which was calculated with the PHITS code [5] is shown in fig. 3. The peak energy of the X-ray is estimated to be around 0.1 MeV. For the simulation, the pencil-like electron with a diameter of 1 cm and the energy of 9 MeV was defined as an initial source. The incident electrons induced the bremsstrahlung photons in the copper plate. The emitted photons were counted at the distance of 1 m between the electron axis and the tally surface. 2. 2. Thermal neutron source. The cross-sectional view of the thermal neutron source is shown in fig. 2. In the neutron production, the bremsstrahlung photon is also generated in a similar manner as the X-ray source. The higher energy electron, however, is used to induce the photonuclear reactions of lead isotopes by the generated photons. After the photons are generated by hitting a 4-mm-thick tungsten disc with the 34 MeV electron, the neutrons are produced in the thick lead blocks by the photonuclear reactions. The produced neutrons are thermalized with a polyethylene moderator (12 cm 12 cm 5 cm) which is surrounded graphite reflectors at room temperature. The thermalized neutrons are extracted as neutron through the exit aperture with an area of 10 cm 10 cm in the perpendicular direction to the electron axis as shown in fig. 2. Three lead blocks which are mounted in the graphite reflectors are a to prevent the bremsstrahlung photons from entering into the neutron course. The energy distribution of the neutron, which was also calculated with the PHITS code, is shown in fig. 3. The distribution ranges from 0.01 ev to 10 MeV and the peak energy is 0.03 ev. A point neutron source with the Maxwell-Boltzmann distribution of kt =1.3MeV was defined at the neutron production target as an initial source because of the computed time limitations. The thermal neutrons emitted from the moderator were counted at the distance of 1 m between the electron axis and the tally surface. 3. Test measurements for a complementary imaging Test measurements were performed to demonstate a complementary imaging by using the convertible source system. A detector based on a Gd-type neutron image intensifier (TOSHIBA Ultimage TM -nγ-04) [6, 7] was applied to the sources for the purpose of dual use, where a digital camera (CANON EOS 5D markii) was used as an image recorder.

4 T. KAMIYAMA et al. (c) (d) Anode current Steel can collector Separator Cathode Anode + - Resin exterior label Plastic sealing gasket Metal washer Fig. 4. Radiography images of the C-size alkaline battery measured with the X-ray and neutron s. (c) shows the result which is divided the brightness value of by the one of at each pixel. An illustration of typical alkaline battery (d) is presented for comparison. The distance between the source (i.e., the electron axis) and the detector was approximately 6 m. A sample, alkaline battery, was located on the front of the input window of the detector. Each measurement time was 20 minutes. Figures 4 and present the images that were measured with the X-ray and neutron s, respectively. The brightness values of the images can be directly compared owing to the complementary imaging. The result which is divided the brightness value of fig. 4 by the one of at each pixel is shown in fig. 4(c). A difference between the images measured with the X-ray and neutron s is clearly observed on the right side. It implicates that the substance of the portion is including hydrogen since the portion is radiopaque for neutrons and radiolucent for X-rays. For comparison, a typical alkaline battery is also illustrated in fig. 4(d). A plastic sealing gasket is generally embedded in the battery on the negative terminal side to vent interior gas pressure for safety reasons. In the test measurements, the neutron time-of-flight (TOF) method was not applied, although the electron accelerator was operated at a repetition rate of 50 Hz and pulse width of 3 μs. Therefore, more detailed information about substances of a sample would be obtained from the neutron TOF images by utilizing the detector combined with other recorders such as a high-speed camera. In addition, the γ-flash event contaminated in the neutron would be distinguished. 4. Conclusion The convertible source system for the neutron and the X-ray imagings has been installed in the 45 MeV electron linear accelerator facility at Hokkaido University. The system allows us to selectively use both s without change of sample and detector positions. We demonstrated the test measurements to present that the convertible source system is very useful for the complementary imaging. As the results, the different images for the same sample were obtained with the neutron and X-ray s. Moreover, the enhanced contrast could be simply obtained by comparing the brightness value of both images at the same pixel. Further work is carrying on adding the neutron TOF measurements in combination with the X-ray radiography in order to provide more detailed information about substances and structures of a sample.

CONVERTIBLE SOURCE SYSTEM OF THERMAL NEUTRON AND X-RAY ETC. 5 The research is supported under the Photon and Quantum Basic Research Coordinated Development Program by the Ministry of Education, Culture, Sports, Science and Technology (MEXT), Japan. REFERENCES [1] Harvel G. D. et al., Nucl. Instrum. Methods A, 371 (1996) 544. [2] Banhart J. et al., Int. J. Mater. Res., 101 (2010) 1069. [3] Kamiyama T. et al., Nucl. Instrum. Methods A, 651 (2011) 28. [4] de Beer F. C. et al., Nucl. Instrum. Methods A, 542 (2005) 1. [5] Sato T. et al., J. Nucl. Sci. Technol., 50 (2013) 913. [6] Nitto K. et al., Nucl. Instrum. Methods A, 535 (2004) 686. [7] Kamiyama T. et al., Phys. Procedia, 26 (2012) 231.