The development of new generation electronic personal dosimeters

Similar documents
Personal Dose Monitoring System

Energy response for high-energy neutrons of multi-functional electronic personal dosemeter

Reliability and Traceability in Radiation Calibration

An extremity (wrist) dosemeter based on the Landauer InLight TM whole body dosemeter

Survey Meter OD-01 Address: Phone: Fax: URL:

Radiation Detection. 15 th Annual OSC Readiness Training Program.

Performance Test of the Electronic Personal Neutron Dosemeter in Neutron Fields Simulating Workplaces of MOX Fuel Fabrication Facilities

Ion-Chamber Survey Meter OD-02

Radiation Protection & Radiation Therapy

Laboratory instruction SENSOR DEVICES

Jeancarlo Torres, CHP. Naval Surface Warfare Center Carderock Division

Contents. Charged Particles. Coulomb Interactions Elastic Scattering. Coulomb Interactions - Inelastic Scattering. Bremsstrahlung

Laboratory instruction SENSOR DEVICES

Lab #13: MEASUREMENT OF RADIATION DOSES

Higher -o-o-o- Past Paper questions o-o-o- 3.6 Radiation

Geant4 simulation of SOI microdosimetry for radiation protection in space and aviation environments

PHYS 3650L - Modern Physics Laboratory

Specific Accreditation Criteria Calibration ISO/IEC Annex. Ionising radiation measurements

Recent Activities on Neutron Calibration Fields at FRS of JAERI

Development of a Silicon PIN Diode X-Ray Detector

Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency

Characterization of the 3 MeV Neutron Field for the Monoenergetic Fast Neutron Fluence Standard at the National Metrology Institute of Japan

Neutron Dosimetry with Ion Chamber-Based DIS System

5) Measurement of Nuclear Radiation (1)

Energy calibration of the threshold of Medipix for ATLAS

Outline. Radiation Interactions. Spurs, Blobs and Short Tracks. Introduction. Radiation Interactions 1

... (1) The diagram shows how aluminium sheet is rolled to form foil of constant thickness. rollers source of radiation

High-Resolution Gamma-Ray and Neutron Detectors For Nuclear Spectroscopy

Dosimetry. Sanja Dolanski Babić May, 2018.

Digital two-parametric processing of the output data from radiation detectors

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

Chapter VIII: Photographic films

Detection and measurement of gamma-radiation by gammaspectroscopy

A new neutron monitor for pulsed fields at high-energy accelerators

Chapter 11: Neutrons detectors

External Dosimetry at NPPs; NVLAP, Noble Gas, and TEDE

Measurement of induced radioactivity in air and water for medical accelerators

BETA-RAY SPECTROMETER

Accuracy, Calibration, Type Testing and Traceability General. Peter Ambrosi

Introduction. Neutron Effects NSEU. Neutron Testing Basics User Requirements Conclusions

Become Aware: Preparation for a Radiological Terrorism Event Ionizing Radiation and Its Biological and Human Health Effects

Development And Testing of a Thermoluminescent Dosemeter for Mixed Neutron-Photon-Beta Radiation Fields

He-3 Neutron Detectors

Mitigation of External Radiation Exposures

Part E. Radiation monitors. Radiation Safety - JUAS 2014, X. Queralt. Part E. Radiation monitors

Commissioning of the Beta Secondary Standard (BSS2)

EEE4106Z Radiation Interactions & Detection

Quality Assurance. Purity control. Polycrystalline Ingots

Introduction. Principle of Operation

Neutron Metrology Activities at CIAE (2009~2010)

General Physics (PHY 2140)

General Physics (PHY 2140)

City University of Hong Kong

Radiation Detection and Measurement

Introduction to Radiological Sciences Neutron Detectors. Theory of operation. Types of detectors Source calibration Survey for Dose

Researchers at the University of Missouri-Columbia have designed a triple crystal

MEASUREMENT AND DETECTION OF RADIATION

COMPARISON OF PERSONNEL RADIATION MONITORING DOSIMETERS DESIGNED FOR MEDICAL FIELD

sample What happens when we are exposed to radiation? 1.1 Natural radiation Cosmic radiation

SILVER NEUTRON ACTIVATION DETECTOR FOR MEASURING BURSTS OF 14 MEV NEUTRONS

Nuclear Spectroscopy: Radioactivity and Half Life

Neutron Detector Gamma Insensitivity Criteria

Name Date Class NUCLEAR RADIATION. alpha particle beta particle gamma ray

SCINTILLATION DETECTORS AND PM TUBES

Gy can be used for any type of radiation. Gy does not describe the biological effects of the different radiations.

Unit 2. Instrumentation. Experts Teaching from Practical Experience

Elastic Recoil Detection Method using DT Neutrons for Hydrogen Isotope Analysis in Fusion Materials. Abstract

Novel Plastic Microchannel-Based Direct Fast Neutron Detection

Lab NUC. Determination of Half-Life with a Geiger-Müller Counter

Week 7: Ch. 10 Spec. w/ Scintillation Ctrs. Photomultiplier Devices

Fast-Neutron Production via Break-Up of Deuterons and Fast-Neutron Dosimetry

Shielding of Ionising Radiation with the Dosimetry & Shielding Module

Determination of Ambient Dose Equivalent at INFLPR 7 MeV Linear Accelerator

Radioactivity. Lecture 6 Detectors and Instrumentation

Detector R&D in KAPAC

DETECTORS. I. Charged Particle Detectors

Radiation and Radioactivity. PHYS 0219 Radiation and Radioactivity

Ringhals AB. Routines for whole body counting at Ringhals NPP

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Since the beam from the JNC linac is a very high current, low energy beam, energy loss induced in the material irradiated by the beam becomes very lar

THE ACTIVE PERSONNEL DOSIMETER - APFEL ENTERPRISES SUPERHEATED DROP DETECTOR*

Energy Response Characteristics of Several Neutron Measuring Devices Determined By Using the Scattered Neutron Calibration Fields of KAERI

Beta Spectroscopy. Glenn F. Knoll Radiation Detection and Measurements, John Wiley & Sons, Inc. 2000

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

Radiation Dose, Biology & Risk

CONSIDERATION ON THE H p(10) AND H*(10) SECONDARY STANDARD CHAMBER CHARACTERISTICS

RADIATION-METER TM-91/TM-92

Development of Gamma-ray Monitor using CdZnTe Semiconductor Detector

CVD Diamond History Introduction to DDL Properties of Diamond DDL Proprietary Contact Technology Detector Applications BDD Sensors

THE COMPTON EFFECT Last Revised: January 5, 2007

Waves & Radiation exam questions

PERSONNEL DOSE EQUIVALENT MONITORING AT SLAC USING LITHIUM-FLUORIDE TLD S*

New irradiation zones at the CERN-PS

Radionuclide Imaging MII Detection of Nuclear Emission

Chem 481 Lecture Material 3/20/09

Neutron and/or photon response of a TLD-albedo personal dosemeter on an ISO slab phantom

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

PECULIARITIES OF FORMING THE RADIATION SITUATION AT AN AREA OF NSC KIPT ACCELERATORS LOCATION

PARTICLES REVELATION THROUGH SCINTILLATION COUNTER

Transcription:

T-3-5, P-3b-69 The development of new generation electronic personal dosimeters Kei Aoyama, Yoshiyuki Nagase,T.Suzuki, Shinichi Watanabe, Kazufumi Taniguchi, Kunihiro Muramatsu, Mikio Fujita, and Yutaka Fujii Fuji Electric Co., Ltd., Tokyo Japan Japan Atomic Power Company., Tokyo Japan. INTRODUCTION We have developed two new types of small, light, electronic personal dosimeters (EPDs) using semiconductor radiation detectors for dose management of workers at nuclear power plants in place of film badges. One is an easy-to-wear, credit-card-size dosimeter to measure the personal dose equivalents H cm, from X and gamma radiation. The other is a multi-function dosimeter capable of measuring gamma, beta and neutron doses simultaneously, which covers gamma-radiation, neutron in Hp() and beta-radiation in Hp(,7) Both dosimeters contain a rechargeable Ni-Cd battery and are stored in an exclusive charging rack. With direct readout, alarm and instant readout functions, these EPDs are rugged and if a failure happens, by external memory readout apparatus, it is able to read the dose data in the dosimeter. These dosimeters offer sufficient performance and reliability for use as dose record dosimeters. They also have a wireless data communication function, which is used for various tasks such as automatic calibration of radiation sources and transmission of measured data.. SENSORS. Gamma-radiation sensor The gamma-radiation sensor uses a p-type high resistivity silicon wafer on which amorphous silicon is deposited by DC plasma CVD as shown in Fig... In the direction of gamma-radiation incidence, multiple layers of an energy filter are provided to secure an energy response to Hp(). + Energy filter a-si:h Depletion Layer p-si - Fig.- Cross-sectional view of gamma/beta-ray sensor. Beta-radiation sensor The beta-radiation sensor has the same basic structure as the gamma-radiation sensor, but uses a plastic film of 5 mg/cm for the entrance window so that beta-radiations beyond 3 kev can be measured. so, in order to compensate for the energy response to beta-radiations, a discriminator is provided in two stages, upper and lower. For high-energy components to which sensitivity would be larger, the count value of the upper-limit discriminator is multiplied by a constant value C to reduce it. As is evident from the structure, this beta-radiation sensor is sensitive to both gamma- and betaradiations. Hence, for indicating a beta-radiation dose, a count for beta-radiation sensor compensation is taken from the gamma-radiation sensor by an exclusive discriminator and the gamma-radiation component is compensated by subtraction using the following formula: In a field where both beta- and gamma-radiations coexist, a difference in the energy response to gamma-radiations between the beta-radiation sensor and the gamma-radiation sensor (on counts above the discriminator level for beta-radiation compensation) appears as an arithmetic error, causing excessive or poor compensation. Therefore, the discriminator level for beta-radiation sensor compensation in the gamma-

T-3-5, P-3b-69 radiation sensor and the E value in the following formula were set so as to minimize the influence of the energy response: B [(β - C β ) - E γ] where, B: Value determined by beta-radiation calibration (sensitivity constant as beta-radiation sensor) C: Constant level of beta-radiation sensor to compensate for beta-radiation energy response E: Count ratio (beta-radiation compensation coefficient) between gamma and beta-radiation sensors with respect to gamma-radiations β : Count value beyond the lower-limit discriminator of beta-radiation sensor β : Count value beyond the upper-limit discriminator of beta-radiation sensor γ: Count value of gamma-radiation sensor beyond the discriminator for beta-radiation sensor compensation.3 Neutron sensor The neutron sensor is composed of a fast neutron sensor and a thermal neutron sensor, and has a p- type low-resistivity silicon wafer on which amorphous silicon was deposited as in the gamma-radiation sensor (see Fig..). Low-resistivity silicon is used to reduce the gamma-radiation sensitivity by reducing the thickness of the depletion layer. + Polyethylene Radiator a-si:h Depletion Layer p-si - Fast neutron sensor (En>MeV) + B Layer a-si:h Depletion Layer p-si - Slow neutron sensor (thermal<en<mev) Fig.- Cross-sectional view of the slow and fast neutron sensors For the fast neutron sensor, a polyethylene radiator of about.8 mm is inserted in the direction of neutron incidence, so this sensor acts as a recoil proton detector. The thermal neutron sensor consists of amorphous silicon on which a boron (B) film is formed in order to detect thermal neutrons by utilizing the B(n,α)Li reaction. Neutron dose is determined by totaling the count values from the above sensors according to the formula: (Nth nth + NF nf) where, Nth: Sensitivity constant of thermal neutron sensor nth: Count value of thermal neutron sensor Nf: Sensitivity constant of fast neutron sensor nf: Count value of fast neutron sensor Each discriminator level of the above sensors is determined in consideration of the influence of gamma-radiations. However, the fast neutron sensor does not have a Q value due to its nuclear reaction and its sensitivity is about one-hundredth that of the thermal neutron sensor. Therefore, in the high-energy gammaradiation field of 6 N, etc., gamma-radiation entry of about % (in terms of gamma-radiation dose) is

T-3-5, P-3b-69 unavoidable. 3. CREDIT-CARD-SIZE GAMMA-RADIATION EPD This dosimeter indicates the personal dose equivalents Hp() from gamma-radiations through integration. When the present dose value or operation time is reached, an alarm is issued by a buzzer and red LED. Cumulative dose and elapsed time are indicated on the LCD and a maximum of 6 points can be memorized in time series. The obtained data can be transmitted to exclusive equipment by wireless serial communication at 9,6 bps. Table lists specification of EPDs Table.Specification of dosemeters card-sizeγ-epd Multifunctional EPD radiation photon photon beta neutron radiation same energy as left dose display range ±% 6Kev~6MeV for 37 Cs.~999.999 msv same as left ±3% 5KeV~.3MeV for 9 Sr/ 9 Y.~999.99 msv 5 Cf :+3% 4 Am-Be:+3%.5eV~5MeV for thermal neutron.~999.99 msv Accuracy ±%.~999.99 msv same as left ±%.~999.9 msv ±%.~999.9 msv dose rate linearity.msv/h~sv/h same as left.msv/h~msv/h.msv/h~msv/h arm diagnostic function means:buzzer and LED levels alarmed at:preset dose or preset time automatic check on count operation Fig 3. card-sizeγradiation-epd(nrx) This dosimeter measures 9 55 8.5 mm and weighs approximately 6 g as shown in Fig. 3.. The energy response expressed as a deviation from the Hp() [Sv] characteristic given in ICRP 5 lies within ±% with reference to 37 Cs (Fig. 3.). The directional characteristic is ±5% max. within ±6 of the perpendicular to the center of calibration (Fig. 3.3), and dose rate linearity is ±% max. between. msv and Sv/h of the value at msv/h (Fig. 3.4). The temperature characteristic is ±% max. from to 4 C with reference to C. 3

±% ±% T-3-5, P-3b-69 Specification:±% (reference: 37 Cs) Dose-equivalent response at Hcm 5 5 5 Energy(keV) Fig.3- X/gamma-ray energy response (Hcm) 5 Specification:±% (reference:(msv/h)) Indication error (%) -5.. 6 Co dose rate (msv/h) Fig.3-3 Gamma-ray dose rate characteristic ( 6 Co) 4. MULTIFUNCTIONAL EPD This dosimeter is capable of measuring a Hp() of gamma-radiations and neutrons, and a Hp(,7) of beta-radiations simultaneously. Each dose value can be displayed on the LCD through switching. l the functions are the same as those of the credit-card-size gamma-radiation dosimeter (NRX), except that the dose alarm can be set for only the gamma-radiation sensor. so, various gamma-radiation characteristics match those of the NRX. This dosimeter measures 55 4.5 mm and weighs approximately 95 g as shown in Fig. 4.. The neutron energy response corresponding to ICRP 5 is evaluated using a monoenergetic neutron source and Ri neutron source selected with an accelerator as shown in Fig. 4.. The dip within a range from a few hundred kev to MeV in this figure is attributable to the influence of the gammaradiation discriminator set value on the fast neutron sensor. On the other hand, the betaradiation energy response is defined in terms of the relative sensitivity of 4 Tl with respect to 9 Sr, and is approximately -3% (Fig. 4.3). Fig 4. Multifunctional EPD(NRN) 4

±3% T-3-5, P-3b-69 Response (indication/radiation)... E-8 E-7 E-6 E-5.... Energy (MeV) Accelerator EPD data Radiation source EPD data Rem counter Fig.4- Neutron energy response (with accelerator) Dose-equivalent response at 7μm Pm-47 Specification:±3% (reference:sr-9) T-4 Sr-9 3 5 3 5 Energy(keV) Fig. 4.3 Beta-ray energy response The directional characteristic of each neutron sensor is evaluated on 5 Cf, and is ±5% max. within ±6 of the perpendicular to the center of calibration (Fig. 4.4). The directional characteristic of the betaradiation sensor is evaluated on 9 Sr, and is ±5% max. within ±3 of the perpendicular to the center of calibration (Fig. 4.5). 5

T-3-5, P-3b-69 Horizontal front Left 3 Right 3 Upper 6 Upper 9 Left 6 Right 6 Upper 3 Left 9 Right 9 Vertical front Lower 3 Lower 6 Lower 9 Specification:±5% (with reference to front) (6 vertically and horizontally) Fig.4-3 Directional characteristic of neutron ( 5 Cf) Horizontal front Left 3 Right 3 Upper 6 Upper 9 Left 6 Right 6 Upper 3 Left 9 Right 9 Vertical front Lower 3 Lower 6 Lower 9 Specification:±5% (with reference to front) (3 vertically and horizontally) Fig.4-5 Directional characteristic of beta-ray ( 9 Sr) For dose rate linearity, inverse-square measurement cannot be performed due to scattering, absorption, etc., so it was evaluated on both the neutron and beta-radiation sensors by using a simulated input. As a result, the indication deviation between. msv to Sv/h was within ±% of the value at msv/h. As an index of beta-radiation discriminating capability in a beta/gamma-radiation coexisting field, beta-radiation dose was measurable with an accuracy of ±3% when gamma-radiation dose was three times as large as beta-radiation dose. And as an index of neutron discrimination in the neutron/gamma-radiation coexisting field, about % of gamma-radiation dose was contained in the count of neutron dose in the 6N gamma-radiation atmosphere. 5. PERFORMANCE EVALUATION OF EPDS These EPDs have been used in the Tokai nuclear power plant of Japan Atomic Power Company since October 997, and in its Tsuruga nuclear power plant since December 997. At present, the EPDs are used as auxiliary dosimeters and their performance is being evaluated and compared with FBs to verifty that they can be used as legal dosimeters. Actual application data with FBs and EPDs for gamma-radiation measurement in the past one year were compared. Figures 5. and 5. compare the monthly cumulative dose in the Tokai and Tsuruga plants, respectively. 6

AN*mSYEAR/MONTHMFBEPD FB T-3-5, P-3b-69 8 EPD FB EPD/FB..8 6.6 4.4 M A N * m S v 8...8 EPD/FB 6.6 4.4. 97/ 97/ 97/ 98/ 98/ 98/3 98/4 98/5 98/6 98/7 98/8 98/9 98/ 98/ 98/ 99/ 99/ 99/3 99/4 99/5 99/6 99/7 99/8 99/9 99/ 99/ 99/ YEAR/MONTH. Figure 5.. Comparison between EPD and FB (Tokai) 5 v5.5 EPD/FB 97/ 98/ 98/ 98/3 98/4 98/5 98/6 98/7 98/8 98/9 98/ 98/ 98/ 99/ 99/ 99/3 99/4 99/5 99/6 99/7 99/8 99/9 99/ 99/ 99/.5 E PD/Figure 5.. Comparison between EPD and FB (Tsuruga) The ratio of the monthly totaled dose indication on EPD to that on EB lies within.93 to.7 (EPD indication value/fb indication value), thus showing satisfactory coincidence. In the monthly cumulative dose of individuals, there were only.% where the indication difference between FB and EPD exceeded % (or.5 msv). The occurrence of troubles in using EPDs such as failure to collect data can be considered to be zero. Based on the above results, use of the EPD as a legal dosimeter for gamma-radiation measurement should not cause a problem. When using EPDs for beta-radiation and neutron measurements, several problems have been reported, but such problems occurred primarily because the equipment was adjusted under conditions that did not match the radiation environment in the power plant, and are being solved. 6. FUTURE PLANS The results of actual use of EPD are currently being evaluated. In addition, a device for calibrating 7

T-3-5, P-3b-69 EPDs has been introduced and is now in use. When the whole EPD system is completed, JAPC intends to switch over to using EPDs. 7. REFERENCES. T.Nakamura, M.Sasaki, T.Suzuki, O.Ueda,. Nuclear Instruments and Methods in Physics Research A 48(998)465-475 8