Mass Spectrometry. A truly interdisciplinary and versatile analytical method

Similar documents
Lecture 8: Mass Spectrometry

Lecture 8: Mass Spectrometry

Lecture 15: Introduction to mass spectrometry-i

Università degli Studi di Bari CHIMICA ANALITICA STRUMENTALE

2. Separate the ions based on their mass to charge (m/e) ratio. 3. Measure the relative abundance of the ions that are produced

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Mass Spectrometry. General Principles

Mass Spectrometry. Electron Ionization and Chemical Ionization

Qualitative Organic Analysis CH 351 Mass Spectrometry

Molecular Mass Spectrometry

Chemistry 311: Topic 3 - Mass Spectrometry

TANDEM MASS SPECTROSCOPY

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Mass Spectrometry: Introduction

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai

Welcome to Organic Chemistry II

Mass spectrometry and elemental analysis

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Chapter 5. Mass spectrometry

Mass Spectrometry. Introduction EI-MS and CI-MS Molecular mass & formulas Principles of fragmentation Fragmentation patterns Isotopic effects

CHEMISTRY Topic #3: Using Spectroscopy to Identify Molecules: Radicals and Mass Spectrometry (MS) Spring 2018 Dr.

MASS SPECTROSCOPY (MS)

Molecular Mass Spectrometry

MASS SPECTRA measure a compound s Mol. Wt. This ionization type is called: electron impact MS

1) In what pressure range are mass spectrometers normally operated?

M M e M M H M M H. Ion Sources

Mass Spectrometry - Background

Mass Spectrometry (MS)

LC-MS Based Metabolomics

Structural Determination Of Compounds

Harris: Quantitative Chemical Analysis, Eight Edition

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

Welcome!! Chemistry 328N Organic Chemistry for Chemical Engineers. Professor: Grant Willson

Welcome!! Chemistry 328N Organic Chemistry for Chemical Engineers. Professor: Grant Willson

Temperature-Programmed Desorption

Ionization Methods in Mass Spectrometry at the SCS Mass Spectrometry Laboratory

12. Structure Determination: Mass Spectrometry and Infrared Spectroscopy

Other Methods for Generating Ions 1. MALDI matrix assisted laser desorption ionization MS 2. Spray ionization techniques 3. Fast atom bombardment 4.

Propose a structure for an alcohol, C4H10O, that has the following

Introduction to GC/MS

Chem 550, Spring, 2012 Part I: OVERVIEW OF MASS SPECTROMETRY:

Ionization Techniques Part IV

15.04.jpg. Mass spectrometry. Electron impact Mass spectrometry

Mass Spectrometry Course

Mass Spectroscopy. Base peak. Molecular Ion peak. The positively charged fragments produced are separated, based on their mass/charge (m/z) ratio. M+.

Mass Spectrometry (MS)

Mass Spectrometry in MCAL

Mass Spectrometry for Chemists and Biochemists

Mass Spectrometry (MS)

Auxiliary Techniques Soft ionization methods

CHROMATOGRAPHY AND MASS SPECTROMETER

History of Mass spectroscopy. Mass Spectroscopy. Introduction... Uses of Mass Spec. Where are Mass Spectrometers Used? Mass Spectroscopy Units

MS/MS .LQGVRI0606([SHULPHQWV

MS Goals and Applications. MS Goals and Applications

for the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York

Temperature-Programmed Desorption. C-874 University of Delaware

L. Seda Mut Neslihan Ötük

Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

Macromolecular Chemistry

sample was a solution that was evaporated in the spectrometer (such as with ESI-MS) ions such as H +, Na +, K +, or NH 4

ORGAN IC STRUCTURAL SPECTROSCOPY

L.7. Mass Spectrum Interpretation

IUPAC Terms and Definitions in Mass Spectrometry

Mass spectrometry.

RECOMMENDATIONS FOR NOMENCLATURE OF MASS SPECTROMETRY

IDENTIFICATION OF ORGANOMETALLIC COMPOUNDS USING FIELD DESORPTION IONIZATION ON THE GCT

Chapter 20. Mass Spectroscopy

Introduction to Mass Spectrometry

Interpretation of Organic Spectra. Chem 4361/8361

Mass spectrometry gas phase transfer and instrumentation

Mass Spectrometry. What is Mass Spectrometry?

Mass Spectrometry and Proteomics - Lecture 2 - Matthias Trost Newcastle University

Lecture 14 Organic Chemistry 1

CHEM 241 UNIT 5: PART A DETERMINATION OF ORGANIC STRUCTURES BY SPECTROSCOPIC METHODS [MASS SPECTROMETRY]

MS Goals and Applications. MS Goals and Applications

Monday (March 28)- Mass spectrometry Tuesday (March 29)- Experiment 6: Separa>ons ICP-MS calcula>ons

MASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps

BASICS OF MASS SPECTROMETRY

Chapter 12 Mass Spectrometry and Infrared Spectroscopy

Selecting an LC/MS Interface Becky Wittrig, Ph.D.

Choosing the metabolomics platform

CEE 772 Lecture #27 12/10/2014. CEE 772: Instrumental Methods in Environmental Analysis

(2) Read each statement carefully and pick the one that is incorrect in its information.

CEE 772: Instrumental Methods in Environmental Analysis

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. H i

CEE 772: Instrumental Methods in Environmental Analysis

3 Use of Mass Spectra to Obtain Structural Information

Mass spectrometry of proteins, peptides and other analytes: principles and principal methods. Matt Renfrow January 11, 2008

MS731M: Chemical Analysis of Materials

Mass spectrometry: forming ions, to identifying proteins and their modifications Stephen Barnes, PhD

Press Release: The Nobel Prize in Chemistry October 2002 The Royal Swedish Academy of Sciences has decided to award the Nobel Prize in

MASS SPECTROMETRY. Topics

Lecture notes in EI-Mass spectrometry. By Torben Lund

Introduction to LC-MS

Extrel Application Note

BIOINF 4399B Computational Proteomics and Metabolomics

Mass Spectrometry - part 1

Mass Spectrometry. Anders Malmendal. 1. Physical principles. Mass Spectrometry

Transcription:

Mass Spectrometry A truly interdisciplinary and versatile analytical method MS is used for the characterization of molecules ranging from small inorganic and organic molecules to polymers and proteins. With MS we might be able to determine the molecular weight of a molecule ion, the elemental composition of a molecule ion, and the presence of certain functional groups. for mechanistic studies of gas-phase (ion) chemistry. This is also relevant for a better understanding of the chemistry in our atmosphere and in space. as a mass detector coupled to a GC, HPLC, capillary electrophoresis (CE), and thermo-gravimetric analysis. as an integrated mass detector in many high vacuum systems.

UofW seminar speaker January 2002 The Gas-phase ion chemistry of cluster ions Dr. Paul M. Mayer Assistant Professor Chemistry Department University of Ottawa

History of MS Applications 1899 Early Mass Spectrometry; 1956 Identifying Organic Compounds with MS; 1964 GC/MS 1966 Peptide Sequencing 1974 Extraterrestrial Mass Spectrometry 1990 Protein Structure 1991 Non-Covalent Interactions with ESI 1992 Low Level Peptide Analysis 1993 Oligonucleotide Sequencing 1993 Protein Mass Mapping/Fingerprinting 1996 MS of a Virus 1999 Desorption/Ionization on Silicon 1999 Isotope-Coded Affinity Tags

MS Celebrities 1 st MS Joseph John Thomson (1856-1940) Cambridge University, Great Britain; Nobel Prize in Physics 1906 Ion Chemistry Francis William Aston (1877-1945) Cambridge University, Great Britain; Nobel Prize in Chemistry 1922 ESI of Biomolecules John B. Fenn (1917) Ion Trap Technique Virginia Commonwealth Wolfgang Paul University, Richmond, (1913-1993) Virginia University of Bonn, Germany; Nobel Prize in Physics 1989 Fragmentation Mechanisms Fred W. McLafferty (1923) Cornell University Ithaca, New York Peptide Sequencing using MS Klaus Biemann (1926) MIT, Cambridge, MALDI Massachusetts Franz Hillenkamp (1936) University of Münster, Germany Mechanisms and Applications R. Graham Cooks (1941) Department of Chemistry, Purdue University West Lafayette, Indiana Mechanism of MALDI & ESI Michael Karas (1952) University of Frankfurt, Germany

Basic Concepts A mass spectrometer is an instrument that produces ions and separates them in the gas phase according to their mass-to-charge ratio (m/z). Today a wide variety of mass spectrometers is available but all of these share the capability to assign mass-to-charge values to ions, although the principles of operation and the types of experiments that can be done on these instruments differ greatly. Basically, a mass spectrometric analysis can be envisioned to be made up of the following steps: Sample Introduction Evaporation and Ionization Mass Analysis Ion Detection/Data Analysis Samples may be introduced in gas, liquid or solid states. In the latter two cases volatilization must be accomplished either prior to, or accompanying ionization. Many ionization techniques are available to produce charged molecules in the gas phase, ranging from simple electron (impact) ionization (EI) and chemical ionization (CI) to a variety of desorption ionization techniques with acronyms such as FAB (fast atom bombardment), PDI (plasma desorption ionization), ESI (electrospray ionization) and MALD (matrix assisted laser desorption). The following pages are in part from http://ms.mc.vanderbilt.edu/tutorials/ms/

Sample Introduction Mass spectrometers are operated at reduced pressure in order to prevent collisions of ions with residual gas molecules in the analyzer during the flight from the ion source to the detector. The vacuum should be such that the mean free path length of an ion, i.e., the average distance an ion travels before colliding with another gas molecule, is longer than the distance from the source to the detector. For example, the mean free path length of an ion is approximately one meter at a pressure of 5x10-5 torr, i.e. about twice the length of a quadrupole instrument. Thus, the introduction of a sample into a mass spectrometer usually requires crossing of a rather large pressure drop, and several means have been devised to accomplish this. Gas samples may be directly connected to the instrument and metered into the instrument via a needle valve. Liquid and solid samples can be introduced through a septum inlet or a vacuumlock system. However, when connecting continuous introduction techniques like gas chromatography (GC), high performance liquid chromatography (HPLC) or capillary electrophoresis (CE), special interfacing becomes imperative to prevent excessive gas load.

Ionization Methods The ionization method is chosen criteria are often the following: 1. Physical state of the sample 2. Volatility and thermal stability of the sample 3. Type of information sought Comparison EI, CI, and DI are suitable for high resolution MS; EI works well only for thermally stable and volatile samples; CI, SI, and DI cause much less fragmentation (normally no radicals are formed); DI and SI must be combined with tandem mass detection (MS-MS) to extract more structural information from fragmentation; Organic Structural Spectroscopy by Lambert, Shurvell, Lightner

purely physical processes! Electron Impact Ionization (EI)

The ionization energies of many compounds are on the order of 7-14 ev but electron energies of 70 ev are often chosen for EI-MS to achieve higher signal intensities and to avoid changes in the mass spectrum with small changes in electron energy. The energy domain: 1 J (kg m 2 s -2 ) = 6.24145 x 10 18 ev 1 J mol -1 = 1.03641 x 10-5 ev Energies of chemical bonds are typically between 100 and 600 kj mol -1 (C-H = 435 kj mol -1 ; C-O = 356 kj mol-1, C-N = 305 kj mol -1 ), which are equivalent to 1-6 ev The time domain: A 70 ev electron has a velocity of about 5 x 10 8 cm s -1 and transits a molecule of 1 nm length in 2 x 10-16 s, while a typical bond vibration requires >10-12 s; thus, the molecular conformation remains unchanged as the electronic excitations occurs (Franck-Condon principle) The degree of fragmentation depends on the internal energy deposition in the molecular ion and on the resistance of the molecular structure to bond cleavage (fragmentation).

Schematic representations of an electron ionization ion source Schematic representation of an electron ionization ion source. M represents neutral molecules; e - = electrons; M + = the molecular ion; F + = fragment ions; V acc = accelerating voltage; and MS = the mass spectrometer analyzer.

about every 1/1000 molecule is ionized the sample is heated up until a sufficient vapour pressure is obtained only cations are measured sample pressure in the ion source is about 10-5 torr

Schematic Representation of a Sector Mass Spectrometer Spectroscopic Methods in OC by Hesse, Meier, Zeeh

Mass Analysis for Magnetic Sector MSs Magnetic sectors deflect accelerated beams of ions, with the degree of deflection depending on the mass, the charge, and the velocity of the ion beam. The speed of ions is described by: v = (2zU / m) 1/2 z = ionic charge, m = ion mass, U = acceleration potential (V) The mass separation is given by: r m = mv / zb (cm) B = magnetic field strength (T) Both equations can be combined to give the fundamental equation of MS: m/z = B 2 r 2 m / 2U U and B are kept constant: m/z = constant r 2 m U and r m are kept constant: m/z = constant B 2 For typical values of B max = 1.5 Tesla, r m = 30 cm, and U = 5 kv, the maximum value for m/z is 1953 Da/charge; Metastable ions are generated by fragmentation after acceleration but before entering the magnetic sector. The position of their diffuse peaks in the mass spectrum is given by: m * = m 22 /m 1 z 1 /z 2 2 Example: 1,2,3,4-tetrahydrocarbazole (M = 171) looses ethylene and a metastable peak at 143 2 /171 = 119.6 is observed;

Advantages & Disadvantages of EI-MS Organic Structural Spectroscopy by Lambert, Shurvell, Lightner

Contrasting degrees of fragmentation depending on the chemical structure Radical cations of aromatic and unsaturated conjugated hydrocarbons resist fragmentation more than radical cations of saturated hydrocarbons; Why?

CH 3 C=O + + OCH 2 CH2CH 2 CH 3 Change of ev Lowering the electron beam energy from 70 ev to 15 ev does not necessarily result in the observation of a molecular ion peak CH 2 =CHCH 2 CH 3 + + CH 3 COOH It, however, does change the probability of different fragmentation pathways. Here, the H- rearrangement wins at the expense of singlebond cleavage.

The Molecular Ion Index of hydrogen deficiency (degree of unsaturation) The index of hydrogen deficiency is the number of pairs of hydrogen atoms that must be removed from the corresponding saturated formula to produce the molecular formula of the compound of interest. The index is the sum of the number of rings, double-bonds, and twice the number of triple bonds. Compounds can contain C, H, N, O, halogen, and S. Index = tetravalent (C, Si) - ½ monovalent (H, halogen) + ½ trivalent (N, P) + 1 Bivalent atoms such as O and S do not contribute. What s about H 3 C- SO 3 H? The nitrogen rule Molecular ions containing odd numbers of nitrogen must have an odd number m/z. Example The compound with the molecular formula C 7 H 7 NO has an index of? What are possible molecules? Note that a benzene ring counts for an index of 4, 3 double bonds and one ring!

The isotopic signature recognition of elements [M] +

Calculation of an approximate intensity distribution based on the natural isotope abundance Organic Structural Spectroscopy by Lambert, Shurvell, Lightner

* * average weight of natural mixture of isotopes Organic Structural Spectroscopy by Lambert, Shurvell, Lightner

Molecular formula determination by exact mass measurements Examples The calculated isotope ratios for CO, N 2, and C 2 H 4, all of molar mass 28, are as follow: CO 100 (M) 1.14 (M+1) 0.2 (M+2) N 2 C 2 H 4 100 (M) 0.76 (M+1) 100 (M) 2.26 (M+1) 0.01 (M+2) The calculated isotope ratios for C 3 H 6 and CH 2 N 2, both of molar mass 42, are as follow: C 3 H 6 100 (M) 3.39 (M+1) 0.05 (M+2) CH 2 N 2 100 (M) 1.87 (M+1) 0.01 (M+2)

Calculated exact masses for high resolution MS Cl isotope patterns

Calculated isotopic distribution for protonated bovine insulin. The chemical molecular weight based on elemental atomic weights is 5734.6 Da. The molecular weight based on the most abundant isotope of each element is 5728.6 Da, and the molecular weight based on the most abundant isotopic form of the molecule is 5733.6 Da. Different isotope distributions that match the molecule mass 5733.6 Da