Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Similar documents
The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note

Cerno Application Note Extending the Limits of Mass Spectrometry

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

Cerno Application Note Extending the Limits of Mass Spectrometry

Agilent G3212 GC-APCI Source

Author. Abstract. Introduction

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Agilent All Ions MS/MS

Expectations for GC-MS Lab

Cerno Application Note Extending the Limits of Mass Spectrometry

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Characterization and Classification of Heroin from Illicit Drug Seizures Using the Agilent 7200 GC/Q-TOF

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

Application Note. Authors. Abstract. Introduction. Environmental

Uncontrolled Copy. SOP-060 Chromatography, Tune Evaluation and Troubleshooting. Table of Contents. 1. Principle... 3

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

Understanding Your Spectra Module. Agilent OpenLAB CDS ChemStation Edition

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Automatic Generation of Extract ion Chromatogram for Mass Spectral Peaks with Specific Isotope Labeled Patterns

MassHunter Software Overview

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

Multi-residue analysis of pesticides by GC-HRMS

Accurate Mass for GC/MSD & LC/MSD

MassHunter TOF/QTOF Users Meeting

WADA Technical Document TD2003IDCR

Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Using the ACD/MS Manager Software with Agilent 1100 Series LC/MS Systems. Application Note

Signal, Noise, and Detection Limits in Mass Spectrometry

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Information Dependent Acquisition (IDA) 1

Automated and accurate component detection using reference mass spectra

U.S. EPA Method 8270 for multicomponent analyte determination

Analyzing Semi-Volatiles by GC-MS

Detection of Chemical Warfare Agents by Transportable GC/MS

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Pittcon P

Agilent 5977A Series GC/MSD System

Varian Galaxie Chromatography Data System for Preparative HPLC

brochure brief 5973Network Mass Selective Detector General Description and Configurations

Enhanced Sensitivity for Biomarker Characterization in Petroleum Using Triple Quadrupole GC/MS and Backflushing

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

GAS CHROMATOGRAPHY (GC)

Agilent J&W PoraBOND Q PT Analyzes Oxygenates in Mixed C4 Hydrocarbon Streams by GC/FID and GC/MSD

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

GC Analysis of Polybrominated Flame Retardants Application

Analysis of Extractable and Leachable (E&L) Compounds Using a Low-Energy EI-Capable High Resolution Accurate Mass GC/Q-TOF

1. Prepare the MALDI sample plate by spotting an angiotensin standard and the test sample(s).

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Analysis of Natural Oils and Extracts Using the Low Thermal Mass LTM Series II System

Analyst Software. Automatic Optimization Tutorial

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Agilent G2350A Atomic Emission Detector (AED)

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Band-Selective Homonuclear 2D Correlation Experiments

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

GC-CI-MS analysis of TMS derivatives

Agilent MassHunter Quantitative Data Analysis

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Applying the Agilent 5977A MSD to the Analysis of USP<467> Residual Solvents with the 7697A Headspace Sampler and 7890B GC

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Determination of Elemental Sulfur in Explosives and. Explosive Residues by Gas Chromatography-Mass Spectrometry. Kimberly S.

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

WALKUP LC/MS FOR PHARMACEUTICAL R&D

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

Rapid Analysis of Food and Fragrances Using High-Efficiency Capillary GC Columns. Application. Authors. Abstract. Introduction

Confirmation of Coal Quality Using the Agilent ExoScan 4100 Handheld FTIR Spectrometer

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

Exercise in gas chromatography

The Analysis of Organophosphate Pesticides by LC/MS Application

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Gas Chromatography-Mass Spectrometry (GC-MS)

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

Spring 2010 updated March 24 Determination of Aromatics in Gasoline by Gas Chromatography- Mass Spectrometry: Comparison of Grades and Brands

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Positive and Nondestructive Identification of Acrylic-Based Coatings

The Theory of HPLC. Quantitative and Qualitative HPLC

Agilent MassHunter Quantitative Data Analysis

Analyst Software. Peptide and Protein Quantitation Tutorial

Agilent 240 Ion Trap GC/MS

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Application. Gas Chromatography February Introduction

Transcription:

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs Application Note Author Harry Prest, Ph.D. Senior Chemist in GC-MS Agilent Technologies, Inc. 5301 Stevens Creek Blvd Santa Clara, CA 95051 USA Yongdong Wang, Ph.D. Principal Scientist Cerno Bioscience 14 Commerce Drive Danbury, CT 06810 USA Introduction Cerno Bioscience MassWorks is a post-acquisition software solution for extending mass accuracy beyond the conventional limits and adding spectral accuracy to qualitative MS analysis. This innovative calibration algorithm [1] can extend mass assignment confidence and suggest probable empirical molecular formulae for either molecular or fragment ions to aid in compound identification [1,2]. To apply this approach, the data must be acquired in a suitable format and with associated calibration. This document presents a summary of how to collect the necessary internal and external calibration data in electron impact ionization (EI) mode on an Agilent GC/MSD using the MSD Productivity ChemStation software (ChemStation). Extension to the calibration in chemical ionization (CI) mode should be straightforward.

Instrumental setup For mass spectrometer detector (MSD) data to be suitable for the MassWorks software, it must be collected in raw scan mode. This feature is available on ChemStation G1701DA software versions D.02.00 and higher. To initiate raw scan mode, access the MS SIM/Scan Parameters screen (Figure 1). Set the Acq Mode to Raw Scan. If this item is not one of the options, check your version of the software. The other important parameters that are available in this menu are the Solvent Delay (which is the delay time in minutes before the acquisition begins) and the EMV Mode. It is highly recommended that Gain Factor be selected and used during acquisition. By using Gain Factor, the user can scale the signal directly which is very convenient for keeping signal ion currents within limits [3]. prefers between 7 and 25 scans over the chromatographic peak. Note also that if only the higher mass fragments are of interest, then the scan range can be narrowed and a higher starting mass (Start at Mass) can be used. To achieve 98% or better in Spectral Accuracy [4], a signal-to-noise ratio of at least 50:1 is needed when measured off the averaged mass spectrum across a chromatographic peak. This corresponds to about 17 times above the detection limit for the ion of interest in a given mode of acquisition, such as scan range, or scan speed. This must be explored in the context of the chromatography but on standard columns (0.25 mm i.d. and 30 m length), the sampling rate n is usually set to 2 or 3. Again, a threshold of zero is best for MassWorks. The usual parameters under Edit Scan Parameters must also be optimized. These are the amu scan range (Start at Mass and End at Mass), the threshold (which should be set to zero), and the number of samples (Sampling Rate)(Figure 2). The usual rules apply. Set the mass range as short as possible to cover the compound spectra of interest and set the speed as low as possible (or the Sampling Rate as high as possible) to acquire data with the best statistics. MassWorks Figure 1. MS Parameters screen Figure 2. Scan parameters (upper) and threshold and sampling rate (lower) screens 2

Creating MassWorks calibration methods The MSD EI calibration gas, PFTBA, is used to tune the MSD instrument (calibrate the ion m/z assignments, and set the peak widths) and is also used by MassWorks to generate the calibration data. Another agent (PFDTD) is used as a chemical ionization calibration gas. An external calibration is defined as a calibration gas acquisition alone and acquired as a separate run (method) before or after a set of samples is acquired for analysis by MassWorks. An internal calibration is defined as a calibration gas and sample acquisition within the same run and so is performed with each sample data acquisition. The heated, hyperbolic quadrupole of the Agilent MSD gives very stable mass assignments and an external calibration will serve for most applications [5-6]. For more automated and less frequent sample analysis, a method containing an internal calibration may be a better approach [2]. Directions and suggestions for both these approaches are detailed below. Setting up an external EI calibration method In this approach, a sample is not injected but an acquisition of the PFTBA calibration gas is made alone. Oven temperature is less important, and may be the starting temperature of the oven program, but the column flow must be the same as that during a usual method. In addition, all other MS parameters must be the same as those used in acquiring sample data, such as scan range, sampling rate, and threshold. The only exceptions are the Solvent Delay and the Gain Factor. Since nothing is injected the Solvent Delay can be 0 minutes and the Gain factor should be 1 (Figure 3). Controlling PFTBA calibration gas: 1) In the MS Parameters window (Figure 1) click the Timed Events button to bring up the MS Timed Events Table (Figure 4). 2) Under Time, enter the number of minutes after the run has started that the PFTBA waits before turning on. 3) Select Valve under Event Type. 4) Select Calibration Valve under Parameter 1. 5) Select the Open state under Parameter 2. 6) Select the Add button to add that line to the Timed Events Table. Repeat this procedure with the addition of a half-minute or longer before setting the state to Closed. The example shown in Figure 4 opens the valve at 0.20 min and closes the valve at 1.2 min. Figure 3 Example MS Parameters screen for external calibration method. Figure 4. MS Timed Events Table which controls the EI & CI calibration gas. 3

In the Instrument View, under Instrument, select the top item of the menu, Inlet/Injection Types to get the Inlet and Injection Parameters screen (Figure 5). Set the Injection Source to Manual. Enter the GC Edit Parameters screen and set up an isothermal run, with column flow as in your usual method and a runtime of 1.5 minutes as in Figure 6. Be sure that the method has no pressure pulse or other change in column flow rate. The inlet screen should indicate either split or splitless with no pulse. Save the method. Selecting Run Method will show the Acquisition-Prepare to Inject screen (Figure 7) and require that you press first the Prep Run and then the Start buttons on the GC. Figure 7. Run method, Acquisition - prepare to inject screen, manual injection information. Figure 5. Inlet and Injection parameters, injection source set to manual. Figure 6. GC Edit Parameters screen: GC oven program. 4

When the data file is loaded in data analysis, this acquisition will exhibit a reconstructed total ion chromatogram (RTIC) and spectra similar to Figure 8. Notice there is an initial rise as the valve opens followed by a fall in signal to a plateau. It is important that the gain setting is not so high that the individual ion intensities seen in the spectrum (lower plot of Figure 8) reach >3 10 6 counts. Near saturation for the PFTBA or for the samples you acquire will lead to poor Spectral Accuracy producing poor results. Therefore in this method, the gain factor should be set to 1 or 2 and the calibration checked to insure that a sufficient signal is obtained at the tuning masses especially those of the isotopes. The gain factor can be raised to improve the signal up to the aforementioned limit. Setting up an internal calibration method In this approach, every acquired data file contains an acquisition of the PFTBA calibrant. This has an advantage in that each data file is always connected to a calibration or potential calibration. The disadvantage is that this occurs during the acquisition of a sample. Therefore, it must be assured that the PFTBA spectrum is not contaminated by an early-eluting solvent, high background (column bleed), or late-eluting analytes during the run. The best way to insure this is to perform the calibration at the end of the run after the oven has been cooled. Figure 8. External PFTBA calibration data. 5

To do this, the user simply extends the GC oven and adds a ramp-down in temperature as shown in the example provided by Figure 9. This case is exaggerated, therefore, it is unnecessary to add as much time to the run due to improved cooling of the Agilent 7890A GC. The user then edits the MS parameters accordingly. Since acquisitions are usually at a high EMV, or gain factor setting, an extra line is added to lower the EMV setting during the PFTBA acquisition. This is shown in Figure 11 and will prevent excessive ion counts, which saturate the detector and distort the calibration. Note that the lowering of the EMV by about 300 or 200 V is to avoid saturation. Higher voltages may be necessary depending on the calibration ion signal. The best EM voltage value to target is that given on the instrument ATUNE report. Figure 9. Extending the GC oven run for internal calibrations. 6

To obtain this voltage, look up the voltage provided in the ATUNE report, or the voltage set when the gain factor is equal to 1 in the MS SIM/Scan Parameters screen (Figure 10, lower). Subtract out the voltage for the given gain factor used in acquiring the analytes (Figure 10, upper). The difference is the value that should be entered into the Parameter 1 field in Figure 11 and it is likely a negative number (-294V). This is a good starting point, and may be refined. An example of a sample acquisition with internal PFTBA calibration is shown in Figure 12. Note that the delay needs not be so long between the sample and the PFTBA calibration gas. Figure 11. MS Timed Events screen - example for internal calibration. Figure 10. MS Parameters Screen for a sample acquisition typical EMV setting and solvent delay (upper screen) and ascertaining the target voltage for the calibration gas section of the acquisition (lower screen). 7

Figure 12. Internal Calibration at the end of a run. Conclusion Through the information provided in this note, the user can acquire datafiles containing necessary information for the MassWorks software. Using the calibration data and raw scan acquisition of samples, MassWorks will provide a high degree of mass accuracy in ion assignments allowing determination of the molecular empirical formula. The references provided cite some examples of the utility of this approach and the power of MassWorks in assisting compound identification. Since MassWorks handles chemical ionization (CI) data as well as that acquired in electron impact (EI) ionization mode, the combined approaches of EI and CI should supply insight into unknown compound molecular masses and, through analysis of fragments, helpful structural information. 8

References 1. MassWorks Calibration and Formula ID Tutorial (a webbased flash at http://www.cernobioscience.com/cernodemo.html). 2. GC/MSD Formula Determination for Forensic Chemistry, Cerno Bioscience Application Note No.106, 2009 (http://www.cernobioscience.com/resources/applicatio nnotes/gcmsd_formulaid4forensicchemistry.pdf). 3. Enhancements to Gain Normalized Instrument Tuning: Understanding the Benefits and Features, 5989-7654EN. (Under Literature Library at www.chem.agilent.com). 4. Erve J. C. L.; Gu, M.; Wang, Y.; DeMiao, W.; Talaat, R. E., JASMS, 2009, 20(11), 2058. 5. Wang Y, Prest H. Chromatography, 2006, 27(3), 135. 6. Wang Y, Gu M. Spectroscopy (MS Supplement), May, 2008. Appendix Useful tuning ions appearing in PFTBA: molecular formula of important EI fragments Formula M + Exact [M+1] + (relative abundance) Mass 1 Exact Mass C 12 F 24 N 613.9648 614.9681 (13.7%) C 9 F 20 N 501.9711 502.9745 (10.37%) C 8 F 16 N 413.9775 414.9809 (9.26%) C 5 F 10 N 263.9871 264.9905 (5.93%) C 4 F 9 218.9856 219.9890 (4.45%) C 3 F 7 168.9888 169.9922 (3.34%) C 3 F 5 130.9920 131.9954 (3.34%) C 2 F 5 118.9920 119.9954 (2.22%) CF 3 68.9952 69.9986 (1.11%) CF 2 49.9968 51.0002 (1.11%) 1. Note all extract masses in this Appendix are calculated without counting the gain or loss of an electron from the charge. Useful tuning ions appearing in PFDTD: molecular formula of important PCI tuning fragments Formula M + Exact Mass C 3 F 7 168.9888 C 5 F 10 O 1 H 266.9868 C 11 F 22 O 3 H 598.9574 Useful tuning ions appearing in PFDTD: molecular formula of important NCI tuning fragments Formula M - Exact Mass C 3 F 7 O 184.9837 C 6 F 13 O 2 350.9691 C 8 F 16 O 3 H 448.9670 Agilent Technologies and Cerno Bioscience shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Information, descriptions and specifications in this publication are subject to change without notice. 9

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 2009 Printed in the USA November 10, 2009 5990-4966EN