Wire rope springs for passive vibration control of a light steel structure

Similar documents
Experimental Investigation of the Performances of a WRS-BTU Seismic Isolator

Experimental Analysis of the Relative Motion of a Gear Pair under Rattle Conditions Induced by Multi-harmonic Excitation

Dynamics of structures

1.1 OBJECTIVE AND CONTENTS OF THE BOOK

DEVELOPMENT OF SEISMIC ISOLATION TABLE COMPOSED OF AN X-Y TABLE AND WIRE ROPE ISOLATORS

Comparison between the visco-elastic dampers And Magnetorheological dampers and study the Effect of temperature on the damping properties

A Guide to linear dynamic analysis with Damping

A new seismic testing method E. Kausel Professor of Civil and Environmental Engineering, Massachusetts 7-277, OamWd^e, ^ 027 JP,

A Sloping Surface Roller Bearing and its lateral Stiffness Measurement

Hysteresis Modelling of an MR Damper Applied to Suspension System

Dynamic Tests on Ring Shear Apparatus

ON THE PREDICTION OF EXPERIMENTAL RESULTS FROM TWO PILE TESTS UNDER FORCED VIBRATIONS

Preliminary Examination in Dynamics

The student will experimentally determine the parameters to represent the behavior of a damped oscillatory system of one degree of freedom.

Model tests and FE-modelling of dynamic soil-structure interaction

International Journal of Advance Engineering and Research Development

Modeling, Control and Experimental Validation of a Device for Seismic Events Simulation

SEISMIC BASE ISOLATION

C. points X and Y only. D. points O, X and Y only. (Total 1 mark)

MOOC QP Set 2 Principles of Vibration Control

University of Bristol - Explore Bristol Research. Publisher's PDF, also known as Version of record

VIBRATION ANALYSIS OF E-GLASS FIBRE RESIN MONO LEAF SPRING USED IN LMV

Analysis Of Seismic Performance Of Fps Base Isolated Structures Subjected To Near Fault Events

Preliminary Examination - Dynamics

Single-Degree-of-Freedom Analytical Predictive Models for Lead-Core Bearing Devices

666. Controllable vibro-protective system for the driver seat of a multi-axis vehicle

Seismic Base Isolation Analysis for the Control of Structural Nonlinear Vibration

EXPERIMENTAL VALIDATION OF RE-CENTRING CAPABILITY EVALUATION BASED ON ENERGY CONCEPTS

Vibration Control Effects of Tuned Cradle Damped Mass Damper

Fundamental study on simple quantitative approach of damping performance for semi-active damper

REAL-TIME HYBRID EXPERIMENTAL SIMULATION SYSTEM USING COUPLED CONTROL OF SHAKE TABLE AND HYDRAULIC ACTUATOR

Effects of Damping Ratio of Restoring force Device on Response of a Structure Resting on Sliding Supports with Restoring Force Device

Robust Loop Shaping Force Feedback Controller

Nonlinear Rolling Element Bearings in MADYN 2000 Version 4.3

Lectures Chapter 10 (Cutnell & Johnson, Physics 7 th edition)

Structural Dynamics. Spring mass system. The spring force is given by and F(t) is the driving force. Start by applying Newton s second law (F=ma).

Cyclic behaviour of a reinforced concrete braced frame with high damping rubber devices

KINETIC EEFCT ON FLEXIBLE BODIES BEHAVIOR

Dynamic Analysis Contents - 1

Design Procedures For Dynamically Loaded Foundations

Role of hysteretic damping in the earthquake response of ground

SHAKING TABLE DEMONSTRATION OF DYNAMIC RESPONSE OF BASE-ISOLATED BUILDINGS ***** Instructor Manual *****

PLEASURE VESSEL VIBRATION AND NOISE FINITE ELEMENT ANALYSIS

DEVELOPMENT OF A LARGE SCALE HYBRID SHAKE TABLE AND APPLICATION TO TESTING A FRICTION SLIDER ISOLATED SYSTEM

SHAKING TABLE TEST OF STEEL FRAME STRUCTURES SUBJECTED TO NEAR-FAULT GROUND MOTIONS

ASEISMIC DESIGN OF TALL STRUCTURES USING VARIABLE FREQUENCY PENDULUM OSCILLATOR

Dynamic characterization of engine mount at different orientation using sine swept frequency test

Chapter 23: Principles of Passive Vibration Control: Design of absorber

Dr.Vinod Hosur, Professor, Civil Engg.Dept., Gogte Institute of Technology, Belgaum

SIMULATION AND TESTING OF A 6-STORY STRUCTURE INCORPORATING A COUPLED TWO MASS NONLINEAR ENERGY SINK. Sean Hubbard Dept. of Aerospace Engineering

MODELLING OF MAGNETORHEOLOGICAL DAMPER DYNAMIC BEHAVIOUR BY GENETIC ALGORITHMS BASED INVERSE METHOD

(Refer Slide Time: 1: 19)

Aseismic design of structure equipment systems using variable frequency pendulum isolator

FIFTH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION DECEMBER 15-18, 1997 ADELAIDE, SOUTH AUSTRALIA

Design of an Innovative Acoustic Metamaterial

Energy balance in self-powered MR damper-based vibration reduction system

A STUDY AND DEVELOPMENT OF SEMI-ACTIVE CONTROL METHOD BY MAGNETORHEOLOGICAL FLUID DAMPER IN BASE ISOLATED STRUCTURES

Research Article Experimental Investigations on the Dynamic Behaviour of O-Type Wire-Cable Vibration Isolators

Boundary Nonlinear Dynamic Analysis

Numerical Modelling of Dynamic Earth Force Transmission to Underground Structures

INFLUENCE OF FRICTION PENDULUM SYSTEM ON THE RESPONSE OF BASE ISOLATED STRUCTURES

Displacement ductility demand and strength reduction factors for rocking structures

Vibration Control Prof. Dr. S. P. Harsha Department of Mechanical & Industrial Engineering Indian Institute of Technology, Roorkee

NONLINEAR CHARACTERISTICS OF THE PILE-SOIL SYSTEM UNDER VERTICAL VIBRATION

CONSIDERATIONS ON THE NON-LINEAR MODELLING OF THE DYNAMICS OF THE VIBRATION AND SHOCK ISOLATORS MADE FROM COMPOSITE NEOPRENE

Analytical Predictive Models for Lead-Core and Elastomeric Bearing

Simulating Two-Dimensional Stick-Slip Motion of a Rigid Body using a New Friction Model

Application of bouc-wen model to frequency-dependent nonlinear hysteretic friction damper

CHAPTER 4 TEST REVIEW

AdaptiveImpact Absorption. Smart Technology Centre

Experimental characterization of dry friction isolators for shock vibration isolation

Chapter 4 Analysis of a cantilever

Damping from bearing hysteresis in railway bridges

Capstan Law Motion Planning in Funicular Railways

Inclusion of a Sacrificial Fuse to Limit Peak Base-Shear Forces During Extreme Seismic Events in Structures with Viscous Damping

Dynamic Vibration Analysis of an Isolator

Simple Harmonic Motion Test Tuesday 11/7

CHAPTER 3 QUARTER AIRCRAFT MODELING

IDENTIFICATION OF FRICTION ENERGY DISSIPATION USING FREE VIBRATION VELOCITY: MEASUREMENT AND MODELING

VIBRATION AMPLIFICATION IN OSCILLATING SYSTEMS WITH DEGRADING CHARACTERISTICS *

DESIGN OF TLCD UNDER RANDOM LOADS: A NEW FORMULATION

Frequency response analysis of soil-structure interaction for concrete gravity dams

Estimation of damping capacity of rubber vibration isolators under harmonic excitation

DEVELOPMENT OF A NOVEL ACTIVE ISOLATION CONCEPT 1

midas Civil Dynamic Analysis

Modelling and State Dependent Riccati Equation Control of an Active Hydro-Pneumatic Suspension System

THE PENNSYLVANIA STATE UNIVERSITY SCHREYER HONORS COLLEGE SCHOOL OF ENGINEERING

Experimental Modal Analysis (EMA) on a vibration cube fixture M. Sc. Emanuel Malek Eindhoven November 2017

System Identification procedures for nonlinear response of Buckling Restraint Braces J. Martínez 1, R. Boroschek 1, J. Bilbao 1 (1)University of Chile

Francisco Paulo Lépore Neto. Marcelo Braga dos Santos. Introduction 1. Nomenclature. Experimental Apparatus and Formulation

DYNAMIC RESPONSE OF EARTHQUAKE EXCITED INELASTIC PRIMARY- SECONDARY SYSTEMS

SPACECRAFT EQUIPMENT VIBRATION QUALIFICATION TESTING APPLICABILITY AND ADVANTAGES OF NOTCHING

Earthquake Excited Base-Isolated Structures Protected by Tuned Liquid Column Dampers: Design Approach and Experimental Verification

ME 563 HOMEWORK # 7 SOLUTIONS Fall 2010

T1 T e c h n i c a l S e c t i o n

Research on the synchronous vibration of the non-integral. mechanism under the vibration environment

Dynamic design of automotive systems: Engine mounts and structural joints

NONLINEAR APPROACHES REGARDING MECHANICAL AND THERMAL BEHAVIOUR OF VISCO-ELASTIC VIBRATION ISOLATORS

Step 1: Mathematical Modeling

Numerical Prediction of the Radiated Noise of Hermetic Compressors Under the Simultaneous Presence of Different Noise Sources

Transcription:

Wire rope springs for passive vibration control of a light steel structure STEFANO PAGANO, SALVATORE STRANO Dipartimento di Ingegneria Industriale Università degli Studi di Napoli Federico II Via Claudio 21, 80125, Napoli ITALY salvatore.strano@unina.it Abstract The restoring force of wire rope springs is generated by the wire ropes deformation that, at the same time, dissipates energy due to the friction forces arising between its wires during the deformation of the rope. In this paper, the dynamic behavior of a light structure isolated by means of isolators, constituted by wire rope springs and a ball transfer unit, is investigated; the adopted structure simulates objects sensitive to seismic accelerations, like works of arts or cabinets containing electromechanical devices whose functioning must be ensured during seismic events. In the first part of the paper the system dynamic characteristics are evaluated by means of an experimental modal analysis conducted on a shaking table by assigning different laws of motion to its moving platform. The frequency response has been obtained through monofrequential and multi-frequential excitations; the platform has been also moved with laws deduced from accelerograms recorded during seismic events to evaluate its insulation efficiency. The modal analysis has shown the frequency range where the proposed isolation system produces a beneficial action for the specific passive vibration control application. Experimental data have been used to validate a numerical model that can be adopted to simulate operating conditions different from those of the experimental tests; the results of several simulation are reported to highlight the influence of some parameters on the system dynamic behavior. Key-words: wire rope springs, shaking table tests, experimental modal analysis, nonlinear dynamics, vibration control. 1. Introduction A new type of seismic isolator, consisting of wire rope springs (WRS) and a ball transfer unit (BTU), has been developed at the DII laboratory. The device [1] is constituted (Fig. 1) by two plates between which it is interposed a ball transfer unit which allows horizontal relative displacement between the two plates with low friction; the two plates are connected by wire rope elements whose deformation provide a restoring force and a dissipative action due to friction between the wires of the cables. The device can thus be considered rigid in the vertical direction while the horizontal stiffness can be suitably calibrated choosing the number and the type of rope elements or defining their length (Fig. 2) and/or diameter. The isolator horizontal stiffness must be tuned ensuring that the natural frequency of the isolated system is moved away from the frequency interval where is concentrated most of the seismic energy. In [1] it has been also presented an analytical model of the WRS-BTU behaviour; the model assumes that the restoring force developed by the ropes is characterized by the sum of three contributions: elastic, hysteretic and a nonlinear contribution proportional to the cube of the displacement; furthermore the model takes into account the rolling friction force due to contact between the BTU main ball and the device upper plate. The restoring force description is used to preview the dynamic response of an isolated structure, subjected to seismic ground acceleration and some typical behaviour of nonlinear vibrating systems. The isolator investigation has been extended; in [2] several tests have been reported in order to estimate the BTU friction coefficients as function of E-ISSN: 2224-3429 212 Issue 3, Volume 8, July 2013

the vertical load. The isolator has been tested on the BPI test rig [3-6] to deduce the force-displacement cycles for different amplitude and frequency excitations; the cycles have been also obtained excluding the BTU main ball contact to put in evidence the rolling contribution. Starting from these cycles, the device equivalent shear stiffness and the horizontal equivalent damping have been estimated for different operating conditions. Finally, to check the device insulation efficiency, a base isolated structure has been tested on a shaking table excited with harmonic law displacements. The most commonly techniques used to study the dynamic behaviour of a base isolated structure under seismic loading are the hybrid simulation [7] and the shaking table tests. In the hybrid testing a physical part of the system interacts with a numerical one, in particular, in the case of the base isolation, the physical part is the isolator and the numerical one is the structure. The advantage of this method, with respect to the shaking table tests, is that it is not required the physical structure but, at the same time, the hybrid simulation requires a very complex control system in order to have good results. The present paper reports the tests conducted to define the frequency response for a light isolated structure tested on a shaking table, imposing harmonic displacement laws, sweep functions and movement laws derived from accelerograms recorded during seismic events. Experimental results have been also adopted to identify the parameters of a numerical model to highlight some peculiarities of the dynamic system. As the hysteretic cycles [2] have shown a frequency dependence motion, the restoring force model has been integrated with a viscous type contribution, proportional to the relative speed between structure and platform. Fig. 1 WRS-BTU isolator Fig. 2 Isolators with different wire rope lenght 2. Experimental investigation The experimental investigation has been conducted to obtain the system frequency response function by adopting the classical techniques of the experimental modal analysis. The experimental plant (Fig. 3) is constituted by a steel structure, simulating a cabinet, on four WRS- BTU isolators. The steel frame is equipped with additional masses in order to modify the overall mass m; the lower plates of the isolators have been connected on the platform of the shaking table; the platform can be moved with an assigned motion law by means of a controlled hydraulic cylinder [8]. In order to control the platform displacement taking into account the influence of the isolated steel frame on the system dynamics, different control strategies have been developed [9,10]. For the tests reported in this paper the adopted platform control has been obtained with a linear feedback displacement control and a feedforward action based on the nonlinear inverse model of the hydraulic actuation system [11]. Two accelerometers have been placed on the platform and on the cabinet respectively, with the sensitivity axis displaced along the moving direction. E-ISSN: 2224-3429 213 Issue 3, Volume 8, July 2013

Fig. 3 The test rig At first, mono-frequential excitation techniques have been employed; an harmonic motion, with assigned amplitude and frequency, has been imposed to the platform. This technique is accurate and simple to apply, however it requires much time and many elaborations to obtain adequate resolution for frequency response curve. The procedure has been limited to few frequency values, and the results, in terms of modulus, have been useful to check the results obtained by means of a multifrequential excitation that allows to quickly deduce the frequency response. In particular, a first set of tests have been performed exciting the platform with a constant amplitude of 5 mm and frequency values comprised in the 0.75 5.0 Hz interval, with a step of 0.25 Hz; Fig. 4 and 5 show the accelerograms and their relative FFT obtained for platform displacement amplitude of 5mm and 10mm and for a frequency of 2Hz. From both diagrams it can be deduced that the cabinet acceleration is lower than the platform one and therefore the cabinet can be considered isolated. Fig. 4 Accelerograms and FFTs for Amp=5 mm and Freq= 2 Hz Fig. 5 Accelerograms and FFTs for Amp= 10mm and Freq= 2 Hz E-ISSN: 2224-3429 214 Issue 3, Volume 8, July 2013

Cabinet signals are characterized by several ultra-harmonic components that may be due to the presence of nonlinear wire rope springs but also to the fact that platform acceleration is not purely harmonic, as evidenced in the FFTs. In fact the hydraulic actuator control system is able to well track the desired displacement law but not the same happens for the acceleration as evidenced in Fig. 6, 7 where the comparisons between the desired platform displacements and accelerations for both tests are reported. In particular, Fig. 4,5 show that the table acceleration spectra contain an appreciable ultraharmonic 6 Hz component which gives an irregular shape to the acceleration signal; such component is filtered by the suspension and therefore it is absent in the cabinet acceleration. Fig. 7 Platform displacement and acceleration: comparison with the reference diagrams (Amp=10 mm and Freq= 2 Hz) To highlight the acceleration transmissibility, in Fig. 8 the ratio between the cabinet and the platform amplitude acceleration is reported; in particular, the diagram shows the ratios between the harmonic components synchronous with the excitation frequency. It can be noted that the cabinet acceleration exceeds the platform one for frequencies close to 1 Hz while the acceleration is attenuated for frequencies higher than 1.5Hz. Fig. 6 Platform displacement and acceleration: comparison with the reference diagrams (Amp=5 mm and Freq= 2 Hz) Fig. 8 Acceleration ratio vs. forcing frequency Driving the platform with a frequency sweep motion characterized by a constant amplitude equal to 5 mm and a frequency increasing with a rate of E-ISSN: 2224-3429 215 Issue 3, Volume 8, July 2013

0.01 Hz/s until 3Hz both, platform and cabinet accelerations have been detected; reporting in the same diagram the corresponding frequency spectrum curves, it can be noted that the acceleration platform amplitude grows with parabolic law while the cabinet acceleration has a trend that resembles the acceleration response of a linear single degree of freedom system with constant parameters for which the acceleration frequency response has a peak in correspondence of the natural frequency f n (whose amplitude depends on the damping ratio), passes for the characteristic point for a frequency value equal to fn 2 and then it begins to grow again (Fig. 9). Fig. 10 Acceleration frequency spectrum for the sweep motion (m=185 kg) Finally, the platform has moved with a law motion derived from accelerogram recorded during seismic events. The data refer to two earthquakes occurred in Italy (Friuli 1976; Irpinia 1980). Fig. 9 Acceleration transmissibility for different value of the damping ratio The frequency spectrum (Fig. 10) shows that the system is characterized by a damping that is able to contain the acceleration peak in correspondence of the resonance; for excitation frequencies higher than 1.5 Hz the isolation system reduces the amount of acceleration transmitted to the cabinet that is always lower than that of the platform. The figure shows that this kind of isolation system is able to limit the acceleration transmission in resonance condition as well as for higher frequency excitation. Fig. 11 Friuli earthquake (Italy, 1976); accelerograms and acceleration frequency spectrum (m=185 kg) E-ISSN: 2224-3429 216 Issue 3, Volume 8, July 2013

F(t) = F c (t) +F r (t) (3) where, F c represents the wire ropes action and F r is the BTU rolling friction force. The F c component is given by the sum of four independent components: F ( t) = F ( t) + F ( t) + F ( t) F ( t) (4) c el h nl + v Fig. 12 Irpinia earthquake (Italy, 1980); accelerograms and acceleration frequency spectrum (m=185 kg) The comparison between the acceleration time history of the cabinet and the platform one (Fig. 11,12) shows that the cabinet acceleration peaks are always lower than the platform ones and therefore the system can be considered isolated. The tests have been repeated with a lighter cabinet mass (165 kg) and the trend results similar even in terms of frequency spectrum. 3. Numerical investigation The nominal sizes of the cabinet have been chosen to have a coincidence between the center of gravity and of the rigidity centre of the isolation system; in the model it can be assumed that the cabinet mainly moves along the direction of excitation and therefore it can be schematized as a single degree of freedom vibrating system. The dynamical behaviour of the isolated structure can so be simulated by integrating the following equation: m x + 4 F = 0 (1) being x(t) the cabinet displacement and F the restoring force exerted by each isolator along the excitation direction. Furthermore, by indicating with x g (t) the platform (ground) displacement and with: d( t) = x ( t) xg ( t), the relative displacement between cabinet and ground, the cabinet motion equation in term of relative motion is: md + 4F = mx g (2) The isolator reaction F can be modeled as the sum of the following components: being: F el, is the elastic component, proportional to the displacement; F h is the hysteretic component, F nl is a nonlinear component proportional to the cube of the displacement, and F v is the viscous damping component. The hysteretic force can be derived from the Bouc Wen model. The analytical expression of the hysteretic force has been presented in [14, 15] and it is here reported: Fh ( t) = kww( t) w ( t) = ρx ( t) 1 [ sgn( x ( t)) w( t) ] (5) By properly choosing the set of parameters (ρ, k w ), it is possible to accommodate the response of the model to the real hysteresis loops; the use of parameter identification techniques is a practical way to perform this task [16, 17, 18]. The BTU rolling component F r (t) is expressed through a Coulomb model: F r = C N sgn[ x ( t)] (6) a The values of the friction coefficient C a, versus the vertical load N, have been experimentally identified [2]. 4. Comparison between simulated and experimental data To verify the model reliability, several simulations have been performed with the same data of experimental investigations. In particular, Fig. 13 and 14 show the comparisons with experimental results obtained with a harmonic excitation at 2 Hz, and amplitudes of 5 and 10 mm respectively. The results reported in Fig. 13 show a good agreement between the experimental and simulation data; while, in the case of an amplitude of 10 mm the experimental results are slightly different with respect the simulation ones; this can be due to the hypothesis of a mono-dimensional E-ISSN: 2224-3429 217 Issue 3, Volume 8, July 2013

motion of the isolated cabinet that for a higher value of the ground acceleration amplitude it is not strictly appropriate. Fig. 13 Comparison between theoretical and experimental cabinet acceleration (Amp= 5 mm and Freq = 2 Hz) Fig. 15 Comparison between theoretical and experimental frequency spectrum of the cabinet acceleration (sweep test m = 165 kg) Fig. 14 Comparison between theoretical and experimental cabinet acceleration (Amp= 10 mm and Freq = 2 Hz) Fig. 15 and 16 show the comparison with the sweep tests conducted with cabinet masses of 165 kg and 185 kg. The frequency response of the numerical model for both the sweep tests clearly reproduce the experimental behavior of the cabinet. Fig. 16 Comparison between theoretical and experimental frequency spectrum of the cabinet acceleration (sweep test m = 185 kg) Finally, Fig. 17 and 18 report the comparisons conducted by imposing seismic excitations [19]. Also in the case of a seismic ground motion the model is able to describe the nonlinear dynamics of the system; this is confirmed by both the tracking error between the experimental cabinet acceleration and the theoretical one, and the frequency content of the experimental and simulated spectra. E-ISSN: 2224-3429 218 Issue 3, Volume 8, July 2013

Fig. 17 Friuli earthquake (Italy, 1976); comparison between theoretical and experimental cabinet acceleration (m=185 kg) The comparisons between theoretical and experimental data for all the tests show that the model is validated and it can so be adopted to simulate operating conditions different from those of the experimental tests. The analytical description of the restoring force is able to reproduce the nonlinear characteristic of the isolator; this is an important results because a linear approach don t allow to describe the nonlinear nature of the isolated steel frame [20]. Fig. 18 Irpinia earthquake (Italy, 1980); comparison between theoretical and experimental cabinet acceleration (m=185 kg) The isolation system efficiency can be evaluated adopting different values of the cabinet masses. Fig. 19 and 20 report the cases for m = 198 kg and 132 kg respectively; in both cases platform motion is characterized by an amplitude of 10 mm and a frequency excitation of 2 Hz. The acceleration ratio is equal to 0.47 in the first case and 0.67 in the second case. E-ISSN: 2224-3429 219 Issue 3, Volume 8, July 2013

been executed even with recorded seismic excitation to confirm its efficiency. The results of the experimental investigation have highlighted the frequency range where the WRS-BTU isolators can be utilized for vibration reduction. This aspect could be an important indication for the design of passive vibration control by means of these devices. In order to have a mathematical description of the isolator restoring force, an analytical model for Fig. 19 Accelerations and restoring force for cabinet mass of 198 kg. Platform motion: Amp= 10 mm and Freq = 2 Hz The simulation results show that an increase of the suspended mass value produces a reduction of the acceleration ratio. For the same tests, the diagram of the restoring force as a function of the relative displacement between the platform and the cabinet is reported. The maximum value of the isolator shear deformation for both the tests is less than the limit equal to 0.05 m. 5. Conclusion An experimental investigation has been conducted to evaluate the efficiency of WRS-BTU seismic isolators. The dynamic characterization of a laboratory cabinet, equipped with four isolators, has been performed with a shaking table. The seismic performances of the isolators have been evaluated comparing the imposed ground acceleration and the cabinet one. First tests have been conducted by means of harmonic and sweep excitation. Other tests have Fig. 20 Accelerations and restoring force for cabinet mass of 132 kg. Platform motion: Amp= 10 mm and Freq = 2Hz describing the hysteretic behavior of the WRS- BTU isolator has been developed and experimentally validated. The analytical prediction of the response of the cabinet supported by the proposed isolators has been in good agreement with experimental results. E-ISSN: 2224-3429 220 Issue 3, Volume 8, July 2013

The validated nonlinear model has been also used to simulate operating conditions different from the those experimentally evaluated on the shaking table. References [1] G Di Massa, S Pagano, E Rocca, S Strano, Sensitive equipments on WRS-BTU isolators, Meccanica, DOI: 10.1007/s11012-013-9708-9, 2013. [2] R Brancati, G Di Massa, S Pagano, E Rocca and S Strano, Experimental Investigation of the Performances of a WRS-BTU Seismic Isolator, Proc. of the World Congress on Engineering WCE 2013, July 3 5, London, U.K., 2013. [3] S Pagano, R Russo, S Strano, M. Terzo, Nonlinear modelling and optimal control of a hydraulically actuated seismic isolator test rig, Mechanical Systems and Signal Processing, Vol. 35, No. 1 2, 2013, pp. 255 278. [4] M Cardone, S Strano, Fluid-Dynamic Analysis of Earthquake Shaking Table Hydraulic Circuit (ESDA2012-82422), Proc. of the ASME 11th Biennial Conference on Engineering Systems Design and Analysis (ESDA2012), Vol. 2, 2012, pp. 343 350. [5] S Pagano, R Russo, S Strano, M Terzo, Modelling and Control of a Hydraulically Actuated Shaking Table Employed for Vibration Absorber Testing (ESDA2012-82118), Proc. of the ASME 11th Biennial Conference on Engineering Systems Design and Analysis (ESDA2012), Vol. 1, 2012, pp. 651 660. [6] M Cardone, S Strano, M Terzo, G Vorraro, A Numerical and Experimental Fluid-dynamic Analysis of a Hydraulic Actuator by means of Closed Loop Tests, Proc. of the World Congress on Engineering WCE 2013, July 3 5, London, U.K., 2013. [7] A Calabrese, G Serino, S Strano and M Terzo, Investigation of the Seismic Performances of an FRBs Base Isolated Steel Frame through Hybrid Testing, Proc. of the World Congress on Engineering WCE 2013, July 3 5, London, U.K., 2013. [8] F Liccardo, S Strano and M Terzo, Optimal Control Using State-dependent Riccati Equation (SDRE) for a Hydraulic Actuator, Proc. of the World Congress on Engineering WCE 2013, July 3 5, London, U.K., 2013. [9] S Strano, M Terzo, A first order model based control of a hydraulic seismic isolator test rig, Engineering Letters, Vol. 21, No. 2, 2013, pp. 52 60. [10] S Strano, M Terzo, A Non-linear Robust Control of a Multi-purpose Earthquake Simulator, Proc. of the World Congress on Engineering WCE 2013, July 3 5, London, U.K., 2013. [11] S Pagano, M Russo, S Strano, M Terzo, A mixed approach for the control of a testing equipment employed for earthquake isolation systems, Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science, DOI: 10.1177/0954406213484424, 2013. [12] R. Bouc. Forced vibration of mechanical systems with hysteresis. Proc. of the Fourth Conference on Nonlinear Oscillation, Prague, Czechoslovakia, 1967, pp. 315 321. [13] Y.K. Wen. Method for random vibration of hysteretic systems. Journal of Engineering Mechanics Division, Vol. 102, No. 2, 1976, pp. 249 263. [14] R Brancati, S Strano, F Timpone, An analytical model of dissipated viscous and hysteretic energy due to interaction forces in a pneumatic tire: Theory and experiments, Mechanical Systems and Signal Processing, Vol. 25, No. 7, 2011, pp. 2785 2795. [15] G Di Massa, R Russo, S Strano, M Terzo, System structure identification and adaptive control of a seismic isolator test rig, Mechanical Systems and Signal Processing, in press. [16] R Russo, M Terzo, Modelling and control design of a magnetorheological fluid brake, International Review of Mechanical Engineering, Vol. 7, No. 3, 2013, pp. 474-478. [17] S Pagano, M Russo, S Strano, M Terzo, Seismic isolator test rig control using highfidelity non-linear dynamic system modeling, Meccanica, DOI: 10.1007/s11012-013-9783-y. [18] P Iodice, A Senatore, G Meccariello, M V Prati, Methodology for the analysis of a 4- stroke moped emission behavior, SAE International Journal of Engines, ISSN: 1946-3936, DOI: 10.4271/2009-24-0142, Vol. 2, No. 2, 2010, pp. 617-626. [19] A. H. Muhr, G. Bergamo, Shaking Table Tests On Rolling-Ball Rubber-Layer Isolation System, Proc. of the 14 th European Conference on Earthquake Engineering, 30 August -3 September, Ohrid, Republic of Macedonia, Vol. 7, 2010, pp. 5703-5710. [20] F Neri, Cooperative evolutive concept learning: an empirical study. WSEAS Transactions on Information Science and Applications, Vol. 2, No. 5, 2005, pp. 559-563. E-ISSN: 2224-3429 221 Issue 3, Volume 8, July 2013