Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Similar documents
TANDEM MASS SPECTROSCOPY

LC-MS Based Metabolomics

MASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps

for the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York

Choosing the metabolomics platform

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Mass Spectrometry. Quantitative Mass Spectrometry Chiral Mass Spectrometry

Types of Analyzers: Quadrupole: mass filter -part1

WADA Technical Document TD2003IDCR

MS/MS .LQGVRI0606([SHULPHQWV

Introduction to LC-MS

Analysis of Polar Metabolites using Mass Spectrometry

What is Tandem Mass Spectrometry? (MS/MS)

Mass Spectrometry. Electron Ionization and Chemical Ionization

Introduction to GC/MS

Mass spectrometry.

Lecture 15: Introduction to mass spectrometry-i

Mass Spectrometry for Chemists and Biochemists

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Introduction to the Q Trap LC/MS/MS System

Mass Spectrometry in MCAL

MS Goals and Applications. MS Goals and Applications

Selecting an LC/MS Interface Becky Wittrig, Ph.D.

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

Technical Note. Introduction

Lecture 8: Mass Spectrometry

Molecular Mass Spectrometry

CHROMATOGRAPHY AND MASS SPECTROMETER

Analytical Technologies and Compound Identification. Daniel L. Norwood, MSPH, PhD SCĪO Analytical Consulting, LLC.

Lecture 8: Mass Spectrometry

Tandem MS = MS / MS. ESI-MS give information on the mass of a molecule but none on the structure

Interazioni di ioni con elettroni (ECD, ETD) e fotoni (Ion spectroscopy) Gianluca Giorgi. via Aldo Moro Siena

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

Overview of NETCHEM MSc & PhD courses: mass spectrometry in EFSC

Mass Spectrometry: Introduction

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

MASS SPECTROMETRY. Topics

CEE 772 Lecture #27 12/10/2014. CEE 772: Instrumental Methods in Environmental Analysis

Hypericin Analysis by LC/MS

CEE 772: Instrumental Methods in Environmental Analysis

Powerful Scan Modes of QTRAP System Technology

Mass Spectrometry and Proteomics - Lecture 2 - Matthias Trost Newcastle University

MS Goals and Applications. MS Goals and Applications

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid. Chromatography-Tandem Mass Spectrometry

LECTURE-11. Hybrid MS Configurations HANDOUT. As discussed in our previous lecture, mass spectrometry is by far the most versatile

De Novo Metabolite Chemical Structure Determination. Paul R. West Ph.D. Stemina Biomarker Discovery, Inc.

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Week 5: Fourier Tranform-based Mass Analyzers: FT-ICR and Orbitrap

New Approaches in the Analysis of Amadori Compounds

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Chemistry 311: Topic 3 - Mass Spectrometry

MS Interpretation I. Identification of the Molecular Ion

Molecular Mass Spectrometry

Ionization Methods in Mass Spectrometry at the SCS Mass Spectrometry Laboratory

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai

LECTURE-13. Peptide Mass Fingerprinting HANDOUT. Mass spectrometry is an indispensable tool for qualitative and quantitative analysis of

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

BIOINF 4399B Computational Proteomics and Metabolomics

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

M M e M M H M M H. Ion Sources

BIOINF 4120 Bioinformatics 2 - Structures and Systems - Oliver Kohlbacher Summer Systems Biology Exp. Methods

Laser Dissociation of Protonated PAHs

Dissociation of Even-Electron Ions

Table of Contents... XI

Finnigan LCQ Advantage MAX

Mass Spectrometry. General Principles

Chem 550, Spring, 2012 Part I: OVERVIEW OF MASS SPECTROMETRY:

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Chapter 5. Complexation of Tholins by 18-crown-6:

Application Note. Edgar Naegele. Abstract

Harris: Quantitative Chemical Analysis, Eight Edition

Ch 13. Basics of Mass Spectrometry (I) : Principles & Ionization Sources

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

GRADUATE COURSE IN MASS SPECTROMETRY: LECTURE 2

Other Methods for Generating Ions 1. MALDI matrix assisted laser desorption ionization MS 2. Spray ionization techniques 3. Fast atom bombardment 4.

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Identification of Human Hemoglobin Protein Variants Using Electrospray Ionization-Electron Transfer Dissociation Mass Spectrometry

Mass Spectrometry (MS)

Mass Spectrometry (MS)

Thermo Finnigan LTQ. Specifications

Agilent G3212 GC-APCI Source

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

(Bio)chemical Proteomics. Alex Kentsis October, 2013

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

Selecting and planning for the right mass spectrometer

Mass Spectroscopy. Base peak. Molecular Ion peak. The positively charged fragments produced are separated, based on their mass/charge (m/z) ratio. M+.

Welcome to Organic Chemistry II

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

What is a mass spectrum?

Welcome! Course 7: Concepts for LC-MS

Translational Biomarker Core

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

Mass Spectrometry in Forensic Science. Erin Shonsey March 16, Overview

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Transcription:

Mass Spectrometry Hyphenated Techniques GC-MS LC-MS and MS-MS

Reasons for Using Chromatography with MS Mixture analysis by MS alone is difficult Fragmentation from ionization (EI or CI) Fragments from each component in one spectrum yields intractable interpretation Suppression effects in soft techniques (ESI) Analytes that are less abundant or ionize poorly may not be detected Quantitation of mixtures is less accurate and less sensitive than quantitation of components that have been chromatographically separated

Chromatography -MS Data Rather than averaging all data into one spectrum, each full scan is saved separately to create a chromatogram TIC - Total Ion Chromatogram EIC - Extracted Ion Chromatogram Scan speed is critical for resolution of close-eluting components peaks could be missed or averaged together spectral tilting Intensities of low/high mass ions skewed

Chromatography -MS Data Identification of Components Background subtraction can be useful in cleaning up spectra Can remove background ions Can remove ions from co-eluting tailing compound EIC can support/contradict that two MS peaks are from the same/different compounds Comparing whether time profiles overlap EIC can show if ions come from the peak or are in the background

Offline LCMS LC may also be coupled with MS by fraction collection (ion exchange, size exclusion chromatography, TLC, Flash Column) Fractions may be analyzed by any compatible MS technique Offline Automation LC eluent can be spotted onto a MALDI target using a robot for MS analysis

LC in line with MS Liquid chromatography may be directly coupled to mass spectrometry using an APCI or ESI source Typical flow rates: 100 µl/min-2.5ml/min: APCI source > 1 ml/min: ESI source, usually need splitter ( 4.6 mm column) 1 µl/min - 1 ml/min: ESI source (200 µm- 4.6 mm column) < 1 µl/min: nanospray source ( 150 µm column)

Types of LC coupled inline to MS Most common= reversed phase (i.e. C18, C8, C4) Ion exchange Normal phase Affinity 2D Chromatography (Ion Exchange followed by reversed phase)

Restrictions Non-volatile salts should be avoided as signal suppression will result Strong ion-pairing agents such as trifluoroacetate should similarly be avoided Need polar solvents for ESI Normal phase not compatible with ESI (Use APCI) Additives must be compatible with ionization mode (i.e. ph of separation must match desired ions) Or use post-column addition

GCMS With the advent of capillary columns, GC columns can be inserted directly into the ionization source GC is typically coupled to EI, CI, and FI GC-MS is applicable to a narrower range of compounds due to volatility requirements When GC/MS is applicable, it is a fairly trouble free technique

Tandem Mass Spectrometry (MS/MS or MS n ) Soft ionization techniques such as ESI only result in parent ions, revealing no structural information Hard ionization techniques yield fragments, but specific precursor-product relationships cannot be obtained Isolate and fragment precursor ion and measure m/z of product ions to obtain structural information One mass analyzer isolates, another scans for products

Common Methods of Fragmentation Threshold Dissociation (Weakest bonds are broken) Collision Induced Dissociation (CID) Apply an electric field to accelerate precursor ions and induce bond cleavage via collision with neutral gas molecules (Ar, N 2 ) Infrared Multiphoton Dissociation (IRMPD) Use infrared laser to break bonds Electron Capture Dissociation (ECD) (Random) Multiply-charged cations capture electrons, inducing oddelectron fragmentation

CID + Ar + + Accelerated Precursor Ion Fragmentation through one or more collisions + Product Ions (And Neutrals)

IRMPD + hν + + Isolated Precursor Ion Fragmentation by one or more photons + Product Ions (And Neutrals)

ECD/ETD + e - or M - + + Isolated Precursor Ion Capture of one or more electrons Product Ions (And Neutrals)

Instruments for MS/MS Instruments where one or more analyzers are placed in series Triple Quadrupole (CID at ev levels) Four Sector (CID at kev levels) Quadrupole-Time-of-Flight (Q-TOF) (CID ev) TOF-TOF Trapping Instruments Quadrupole Ion Trap (CID ev, IRMPD, ECD) FT-ICR (CID, SORI-CID, IRMPD, ECD)

Quadrupole Ion Trap M+H MS/MS is done in one analyzer - Precursor Ion is Isolated by selective ejection - Precursor ion is given kinetic energy - Fragments are formed and trapped - Trap is scanned to detect products - Products can be isolated and fragmented etc.

Tandem Mass Spectrometry in an Ion Trap 1) Measure Full Spectrum 2) Ion Isolation: e.g., Precursor m/z 426.7 ± 1.5 50 Relative Abundance100 426.7 700.2 852.3 1138.7 300 900 1500 2000 m/z 426.7 3) Add Collision Energy 4) Measure m/z of Fragment Ions [For Peptide SLNVALR] Fragmentation of 426.7 SLNVAL SLNVA SLNV SLN SL S R LR ALR VALR NVALR LNVALR Courtesy of the MSCLS at the Univ. of Minn.

Triple Quadrupole Mass Analyzer Sample Inlet Ion Guide Q1 Q2 (Collision cell) Q3 EM Detector

Product Ion Scan Mode in a Triple Quadrupole Q1 Mass selection Q2 collision cell Q3 Full Scan A B C Ion C C+Ar Products Products D Ions in Source Q1 only transmits Ion C Fragment Ion C Q3 Scans for products

Multiple Reaction Monitoring (MRM) in a Triple Quadrupole Q1 Mass selection Q2 collision cell Q3 Mass Selection A B D C Ion C C+Ar C1+C2+C3 Ion C2 Ions in Source Q1 only transmits Ion C Fragment Ion C Q3 only transmits Ion C2

Neutral Loss Scan Mode in a Triple Quadrupole Q1 Pass A-H 2 O Q2 collision cell Q3 Pass A Ions A-F Ion A-H 2 O Ion B Ion C Ion D A-H 2 O A + +H 2 O A Ion E Ion F Scans across mass range Fragment ions one at a time Scans across mass range at 18 amu lower than Q1

Precursor Ion Scan Mode in a Triple Quadrupole Q1 Mass selection Q2 collision cell Q3 pass only 79 Ions A-F Ion A-PO 4 Ion B Ion C Ion D PO 3-79 Ion E Ion F Scans across mass range Fragment ions one at a time Transmits only 79

Precursor ion of 79 (-) -/+ Polarity switch Enhanced resolution (+) -/+ Polarity switch Charge state determination MSMS (+)

Intensity (cps) 7.5e8 7.0e8 6.5e8 6.0e8 5.5e8 5.0e8 4.5e8 4.0e8 3.5e8 3.0e8 2.5e8 2.0e8 1.5e8 1.0e8 5.0e7 β-casein Digest Total Ion Chromatogram 0.0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 Courtesy of the MSCLS at the Univ. of Minn. Time, min

Negative Precursor Ion Chromatogram 1.29e8 1.20e8 1.10e8 1.00e8 Intensity (cps) 9.00e7 8.00e7 7.00e7 6.00e7 5.00e7 4.00e7 3.00e7 2.00e7 1.00e7 0.00 5 10 15 20 25 30 35 40 45 50 55 60 65 Time, min Courtesy of the MSCLS at the Univ. of Minn.

2100 1900 Precursor Ion Scan at 30 min 1029.2 1700 Intensity, cps 1500 1300 1100 900 700 500 300 100 400 500 600 700 800 900 1000 1100 1200 m/z, amu Courtesy of the MSCLS at the Univ. of Minn.

Intensity, cps 1.10e5 1031.3 1031.7 1.00e5 9.00e4 8.00e4 7.00e4 6.00e4 Positive Enhanced Resolution Scan +2 ion, MW= 2060.6 5.00e4 4.00e4 1032.2 3.00e4 2.00e4 1.00e4 1031 1032 1033 m/z, amu Courtesy of the MSCLS at the Univ. of Minn.

MSMS on ion 1031.3 for sequence determination 3.4e6 a1 I F Q ps E E Q Q Q T E D E 3.0e6 Intensity, cps 2.6e6 2.2e6 1.8e6 1.4e6 1.0e6 6.0e5 2.0e5 y2 b2 y3 y6 y1-nh3 b2-nh3 y3-nh3 y4 y5 b5 y1 a1-nh3 a2-nh3 b1-nh3y2-nh3 b3 b3-nh3 y5-nh3 b4-nh3 a5y6-nh3 y4-nh3 b4 y8 y10 y7 y9 y10-nh3 y7-nh3 y11 y9-nh3 y11-nh3 y12-nh3 b6 b7 b8 y8-nh3b8-nh3b9-nh3 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 m/z, amu Courtesy of the MSCLS at the Univ. of Minn.

Q-TOF Mass Analyzer Sample Inlet MCP Detector Ion Guide Q1 Q2 (Collision cell) Hexapole TOF Pusher Reflectron Select 1 ion in Q1 (Product Scan) Scan Q1 (Precursor Scan) Cannot perform Neutral Loss Scan

FT-ICR-MS M+H MS/MS is done in one analyzer RF fields can selectively isolate one ion RF fields (on or off resonance) can accelerate ions followed by collisions and detection of products IR laser or electron source can fragment isolated ions followed by detection of products Processes can be mixed, matched, repeated etc.

MS 4 With FT-ICR CO 2 - CO 2 - - O 2 C Reed et. al. JACS, 122, 10689-10696, (2000)

MS 6 With FT-ICR - O 2 C CO 2 - CID CO 2 - CID - - O t-bush - O - SO 2 - low energy O - H high energy CID t-bush No Reaction Phenol Proton Transfer Reed et. al. JACS, 122, 10689-10696, (2000)

Multiple ions at m/z 92

MS/MS Applications Structural elucidation aid for unknown compounds Functional group confirmation Positive Identification of known compounds environmental contaminants biological metabolites controlled substances (illegal drugs, steroids etc.) When Combined with Chromatography Screening of mixtures for specific moieties Structure-specific quantitation Thermochemical information (BDE etc.) Chiral analysis