Application Note. Edgar Naegele. Abstract

Similar documents
Computer-assisted analysis of complex natural product extracts

Application Note. Edgar Naegele. Abstract

Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Analysis of Saponins in Spine Date Seed using Agilent ZORBAX Solvent Saver HT (1.8 µm) Columns

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

Accurate Mass Analysis of Hydraulic Fracturing Waters

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Analysis of Beer by Comprehensive 2D-LC with the Agilent 1290 Infinity 2D-LC system

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Comprehensive 2D-LC Analysis of Chinese Herbal Medicine

Agilent ESI and APCI sources: for polar to non-polar compounds

Pharmaceutical Impurity Identification and Profiling Using Agilent Q-TOF LC/MS Combined with Advanced MassHunter Data Processing Software

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Separation of Large and Small Peptides by Supercritical Fluid Chromatography and Detection by Mass Spectrometry

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

Metabolomics Batch Data Analysis Workflow to Characterize Differential Metabolites in Bacteria

MassHunter TOF/QTOF Users Meeting

QTOF Training Manual

Technical Note. Introduction

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Detection of Trace Level Pharmaceuticals in Drinking Water by Online SPE Enrichment with the Agilent 1200 Infinity Series Online-SPE Solution

Determination of EU-Banned Disperse Dyes by LC/MSD TOF Application

Making Sense of Differences in LCMS Data: Integrated Tools

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

materials analysis Solutions for Your Analytical Business Markets and Applications Programs

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

Translational Biomarker Core

Quantitation of Cystine and Identification of Related Metabolites in White Blood Cells Using a High Resolution Accurate Mass LC/MS Approach

TANDEM MASS SPECTROSCOPY

770-9P. Sensitivity and Selectivity - A Case Study of LC/MS Enantioselective Resolution of Bupivacaine Using Vancomycin as a Chiral Stationary Phase

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Analysis of Polyphenols in Saffron Petal Extracts with UHPLC/UV/MS

Using the Agilent 1290 Infinity II Multicolumn Thermostat with Extreme Temperatures and Flow Rates

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3

A Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Mass Spectrometry in MCAL

Accurate quantification of oleanolic acid and ursolic acid in traditional chinese medicine

Rapid quantification of Chinese medicine Zuo Jin Pill using rapid resolution liquid chromatography

Finnigan LCQ Advantage MAX

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Taking Full Advantage of UHPLC with Agilent 6460A Triple Quadrupole MS. Outline

LC-MS Based Metabolomics

Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments. Application. Introduction. Authors. Abstract.

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Fast and Flexible Optimization of Modifier Concentrations Using an Agilent 1290 Infinity LC System with Blend Assist

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid. Chromatography-Tandem Mass Spectrometry

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Practical Applications of Method Translation Using the Agilent Method Translation Tool Rita Steed Inside Application Engineer Agilent Technologies

Determination of Pharmaceuticals in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes Application

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Determination of Enantiomeric Excess of Metolachlor from Chiral Synthesis using the Agilent 1260 Infinity Analytical SFC System

Agilent LC & LC-MS Cannabis Testing

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Agilent All Ions MS/MS

Transferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system

Introduction to the Q Trap LC/MS/MS System

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Application Note. Abstract. Authors. Environmental

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Transcription:

Agilent MassHunter Fast computer aided analysis of LC/ESI-TF data from complex natural product extracts Part 1: Analysis of Agilent 6210 TF data with the Molecular Feature Extractor in MassHunter Workstation software Application Note Edgar Naegele Abstract Agilent Equipment: 1200 Series Rapid Resolution LC system 6210 Time-of-Flight MS MassHunter Workstation software Application Area: Natural product analysis in drug discovery This Application Note describes: Accurate mass measurement with LC/ESI-TF for the determination of complex natural compound structures Fast computer aided identification and elucidation of chemical structures of new natural product compounds The use of the Agilent 1200 Series Rapid Resolution LC (RRLC) system with rapid resolution high throughput (RRHT) columns for separation of ingredients in a complex ginseng root extract, and the use of the Agilent 6210 ESI-TF mass spectrometer for accurate molecular mass measurement. Processing of TF data with the Molecular Feature Extractor in the MassHunter Workstation software, to generate molecular features, which are discrete molecular entities defined by the combination of retention time and mass.

Introduction Since prehistoric times, herbal extracts have been used for the treatment of disease. Their effects on humans were found by trial and error over generations. A good example for the efficiency achieved is traditional Chinese medicine (TCM). In Western medicine, drugs of natural origin are gaining importance due to their potential. But Western pharmaceutical quality standards require a deep knowledge about the ingredients in medicine based on natural products. A famous Asian herb, which has been used in herbal medicine for more than 5000 years, is the ginseng root (Panax species). Pharmacological effects of ginseng that have been reported are, for example, stimulatory and inhibitory effects on the central nervous system (CNS), antistress, antihyperglycemic, antineoplastic and immunomodulatory effects 1. The main active compounds of the ginsenosides are triterpene saponins, of which more than 80 have been isolated and characterized during the past years. A lot of work has been done during the last 30 years to develop analytical methods for the analysis of ginseng extracts and medical formulations. The method of choice for the analysis of complex natural product extracts, like the ginseng root, is high performance liquid chromatography (HPLC) 2. For the determination of the complex and similar structures of ginsenosides, modern LC/MS equipment such as the LC/ESI-TF for accurate mass measurement and LC/ ion trap or LC/triple quadrupole instruments for structure elucidation by MS/MS and MS n are currently used 3. However the time consuming bottleneck is the examination of the acquired MS data to identify and elucidate chemical structures of new natural product compounds. This Application Note demonstrates the use of the Agilent 1200 Series Rapid Resolution LC (RRLC) system with rapid resolution high throughput (RRHT) columns for the separation of ingredients in a complex ginseng root extract, in combination with the Agilent 6210 ESI TF mass spectrometer for accurate measurement of their molecular masses. The TF data obtained were processed by the Molecular Feature Extractor (MFE) of the MassHunter Workstation software to generate molecular features, which are discrete molecular entities defined by the combination of retention time and mass. Natural product compounds were identified from this simplified MS data. The composition differences between ginseng sub-species is elucidated by software-aided data comparison 4 and an example for an automated approach to analyze complex natural product extracts is given 5. Experimental Equipment Agilent 1200 Series binary pump SL with degasser. This pump has the capability to perform high resolving HPLC analysis on a 1.8 µm particle size column for best resolution performance. Agilent 1200 Series high performance autosampler SL (h-als) with thermostat. This autosampler is especially designed to work together with the Agilent 1200 Series binary pump SL. Agilent 1200 Series thermostatted column compartment (TCC). This TCC is ready for use with the binary pump SL with optional separate heat exchangers and post column cooling under optimized delay volume conditions, as well as alternating column regeneration with an optional 2-position/10-port valve. Agilent 1200 Series diode array detector SL (DAD SL) which can acquire data at a sampling rate of up to 80 Hz. Agilent 6210 MSD TF. rthogonal acceleration time-offlight (TF) mass spectrometer with dual sprayer interface for mass calibration to acquire molecular masses with highest accuracy. This TF mass spectrometer is capable of acquiring data at 40 Hz and with positive/negative switching. Column: ZRBAX SB C18, 2.1 x 150 mm, 1.8 µm particle size. Software: TF instrument control software MassHunter Workstation A02.00 for data acquisition, Analyst software for data review and Molecular Feature Extractor (MFE) software for data processing. In this LC/TF instrument set-up, the binary pump SL, which is in the low delay volume configuration, is connected to the h-als SL with a 0.12-mm ID stainless steel capillary. To reduce delay volume, the seat capillary in the h-als SL has a 0.12 mm ID. The same kind of capillary connects to the low 2

delay volume (1.6 µl) heat exchanger in the TCC, which is connected to the column. For UV detection, a 2-µL cell is built into the DAD SL. The outgoing capillary is directly connected to the sprayer in the electrospray source of the TF mass spectrometer. This instrument set-up is optimized to achieve the highest possible resolution. Sample preparation Powdered freeze-dried Asian and American ginseng root (1g) (Panax ginseng and Panax quinquefolius) was ultrasonically treated for 30 minutes in 10 ml methanol, filtrated and directly used for analysis. The Agilent 1200 Series DAD SL was operated at 80 Hz for data acquisition at a wavelength of 220 nm/4, ref. 360/100 with the 2-µL flow cell, 3-mm path length. The 6210 TF MS was operated under the following conditions: Source: ESI in positive mode with dual spray for reference mass. Dry gas: 12 L/min Dry Temp.: 200 ºC Nebulizer: 35 psi Scan: 200-1300. Fragmentor: 150 V or 300 V for CID Skimmer: 60 V Capillary: 3000 V Results and discussion The ingredients of a ginseng root extract from an Asian ginseng root (Panax ginseng) were separated with the Agilent 1200 Series RRLC system on a RRHT column (1.8-µm particle size) with subsequent ESI TF mass spectrometry (Agilent 6210 TF). The high resolution LC provided an excellent separation of the major and minor ingredients of the natural product extract (figure 1). The acquired TF data were extracted by the MFE software and the identified molecular ions of the comprised compounds were separated from undefined Method The Agilent 1200 Series binary pump SL was operated under the following conditions: Solvent A: Water + 0.1 % TFA; Solvent B: AcN + 0.1 % TFA. Flow: 0.5 ml/min. Gradient: 0 min 5 % B, 1 min 5 % B, 60 min 85 % B, 61 min 95 % B, 70 min 95 % B. Stop time: 70 min. Post time: 15 min. The Agilent 1200 Series high performance autosampler SL was used for injections of 10 µl sample and the samples were cooled to 10 ºC. The sample loop was switched to bypass after 1 minute to reduce delay volume. The Agilent 1200 Series thermostated column compartment was adjusted to 50 ºC and equipped with the low delay volume heat exchanger. Intensity, cps, 1.8e7 1.6e7 1.4e7 1.2e7 1.0e7 8.0e6 6.0e6 4.0e6 2.0e6 0.0 22.0 24.0 26.0 28.0 30.0 32.0 34.0 36.0 38.0 Time, min Figure 1 High resolution LC on a 1.8 µm particle column with an extract from Asian ginseng root (Panax ginseng) for MS analysis by ESI-TF. 3

background ions (figure 2). In this process, the identified ions were clustered to molecular features comprising isotope compounds and adducts. From the processed data, the feature group #7 at the retention time of 26.3 min will be examined in more detail to identify these compounds in the ginseng extract. At this retention time, 20 different features, molecular ions together with their different adducts and isotopes, are grouped together. The processed EIC of feature group #7 at a retention time of 26.3 min is shown in figure 2B. The capability to extract groups of ions as molecular features can be optically displayed by a detailed 2D contour plot of the spectrum, which shows retention time and the mass of the ions (figure 3). The unprocessed chromatograms of the protonated ginsenoside Rb1 ion at 1109.6 and the sodiated ion at 1131.4, both at a retention time 26.3 min, are showing a lot of unspecific chemical noise ions (figures 3A and 3C). These unspecific ions can Intensity (10 3 ) Intensity (10 6 ) 2.5 2.0 1.5 1.0 0.5 0.0 A Processed TIC 15 20 25 30 35 B min 800 Processed 700 EIC: Group #7 (RT=2) --- 20 Features 600 500 400 300 200 100 0 15 20 25 30 35 min Figure 2 A) Software processed TIC of Asian ginseng extract and grouped molecular features. B) Feature group # 7 at retention time 26.3 min groups 20 molecular features. ions remaining at the same retention time window are grouped together to molecular features comprised of adducts and isonot be grouped to a molecular feature because of an unclear isotopic distribution and are eliminated during data processing. The A C B D Figure 3 2D contour plot of TF spectrum of ginseng extract, retention time vs. mass. A) Unprocessed 2D contour plot at retention time 24.8 28.0 min and mass 900 1250. B) Magnified contour plot around the unprocessed ginsenoside Rb1 ions. C and D) Contour plot of processed data of the same mass and retention time area. 4

topes of the basic ion (figures 3B and 3D). The magnified window (figures 3C and 3D) clearly demonstrates the simplification of the data. The data enhancement can also be demonstrated by the comparison of the original mass spectrum of ginsenoside Rb1 (figure 4A) to the processed mass spectrum (figure 4B). The significant simplification of the mass spectra resulting from the generation of molecular features and elimination of chemical noise allows an easier interpretation, especially when fragments of the molecular ion are generated by collision induced decay (CID) for structure elucidation (figure 4B). These fragments, which elute at the same time, are included in the same group of molecular features together with the molecular ion. The interpretation of the spectrum from ginsenoside Rb1 for structure elucidation is shown in figure 5. The protonated molecular ion was found at 1109.6104 and the sodium adduct at 1131.5926. The fragment at 785.5045 is derived from the loss of one glucose moiety. An additional loss of a molecule of water results in the Intensity (10 3 ) Intensity (10 3 ) 700 600 500 400 300 200 100 0 700 600 500 400 300 200 100 0 riginal RT = (26.266, 26.358) A 200 400 600 800 1000 1200 Processed Group #7 (RT=2) --- 20 Features 425.3775 B 767.4935 200 785.5045 1109.6104 1131.5926 400 600 800 1000 1200 Figure 4 A) Unprocessed mass spectrum at 26.3 min. B) Processed mass spectrum at 26.3 min showing molecular features, which belong to the same group. H H H H H H H H 425.3775 H H H H H H H H 3 C 785.5045 C 42 H 73 13 = 785.5045 -H 2 C 42 H 71 12 = 767.4935 C 30 H 49 = 425.3775 Figure 5 Structure of ginsenoside Rb1 obtained by interpretation of the processed mass spectrum with molecular features included. 5

fragment at 767.4935. The loss of the second glucose moiety yielded the ion at 425.3775 from the terpenoide core structure. The identified molecular features for ginsenoside Rb1 and its CID fragments are summarized in table 1. The protonated, sodiated and potasiated adducts are found with high mass accuracies of -0.14, -0.41 and -0.32 ppm, respectively. The calculated mass accuracy of the molecule is -0.41 ppm. In addition, the mass accuracies for the obtained CID fragments and their adducts are calculated (table 1). This confirms the empirical formula and the proposed molecular structure. The content of a natural product extract often depends on the subspecies, the growth region and growth conditions. To decide if a natural plant extract contains the right active ingredients in proper concentration, a comparison to a standard extract is necessary. For ginseng the different sub- Intensity (10 6 ) 4 3 2 1 0 Processed TIC F 11 species contain common ginsenosides as well as specific ginsenosides. A typical example is Asian ginseng (Panax ginseng) (figure 2) in comparison to American ginseng (Panax quinquefolius). The simplification achieved by the generation of molecular features unravels the differences (figure 6). Especially the high content of ginsenoside F11 eluting at 24.5 minutes and the absence of ginsenoside Rf (eluting at 24 minutes in figure 2) is typical for the American ginseng subspecies 5. 20 25 30 35 min Figure 6 Software processed TIC of American ginseng extract and grouped molecular features. Species RT Mass Accuracy RT Mass Accuracy RT Mass Accuracy RT Mass Accuracy M+H 1109.6104 785.5045 767.4935 425.3775 M+H+1 1110.6152 786.5081 768.4976 426.3813 M+H+2 1111.6176 1108.6031-0.14 ppm 787.5108 784.4972 0.10 ppm 769.5004 766.4862 0.68 ppm 427.3850 424.3702 0.75 ppm M+H+3 1112.6219 788.5134 770.5027 428.3882 M+H+4 771.4965 M+Na 1131.5926 807.4486 789.4756 M+Na+1 1132.5964 808.4902 790.4809 M+Na+2 1133.599 1108.6034-0.41 ppm 809.4950 784.4976 0.39 ppm 26.30 791.4883 766.4864 0.42 ppm M+Na+3 1134.6021 26.30 810.4938 M+Na+4 1135.5998 M+K 26.30 1147.5664 1108.6033-0.32 ppm M 1108.6034-0.41 ppm 784.4972 + 0.10 ppm 766.4862 + 0.7 ppm 424.3702 + 0.75 ppm Table 1 Identified molecular features and calculated mass accuracies for empirical formula confirmation. (Ginsenoside Rb1, C 54 H 92 23, M 1108.6029; Fragment C 42 H 72 13, M 784.4973; Fragment C 42 H 70 12, M 766.4867; Fragment C 30 H 49, M 424,3705). 6

Conclusion The ingredients of highly complex natural product samples can be accurately separated by the Agilent 1200 Series RRLC system with 1.8 µm particle size columns. By connecting the ESI-TF MS, a large amount of accurate mass data for empirical formula calculation and compound structure elucidation can be created. This data is processed by the Molecular Feature Extractor of the MassHunter Workstation software, which generates molecular features, including the molecular ion, its isotopes and adducts, to simplify the large amount of data and to help with data interpretation. The highly accurate measured masses of the different molecular species of molecular ions and CID fragments, included in the molecular features, are used for empirical formula calculation and structure elucidation. References 1. Attele A.S., Wu J.A., Yuan C.S., Biochem. Pharmacol. 58, 1685-1693, 1999. 2. Fuzzati N., Analysis methods of ginsenosides. J. Chrom. B1-2, 812, 114-133, 2004. 3. Wang X., Sakuma T., Asafu-Adjaye E., Shiu G. K., Determination of ginsenosides in plant extracts from Panax ginseng and Panax quinquefolius L. by LC/MS/MS. Anal. Chem. 71, 1579-1584, 1999. 4. Edgar Naegele: Agilent Mass- Hunter Fast computer-aided analysis of LC/ESI-TF data from complex natural product extracts Part 2::Comparison of Agilent 6210 TF data from different biological origin with Mass Profiler in MassHunter Workstation software, Agilent Application Note, Publication number 5989-6076EN, 2007. 5. Edgar Naegele: Agilent Mass- Hunter Fast computer aided analysis of LC/ESI-TF data from complex natural product extracts Part 3: Automated analysis of Agilent 6210 TF data from complex natural product extracts, Agilent Application Note, Publication number 5989-6077EN, 2007. 7

Edgar Naegele is Application Chemist at Agilent Technologies, Waldbronn, Germany. www.agilent.com/chem/tof 2007 Agilent Technologies, Inc. Published January 1, 2007 Publication Number 5989-5928EN