A Novel LC-ELSD Method for the Quantification of 2-Deoxy D-Glucose Using HILIC Chromatography

Similar documents
Journal of Pharmaceutical and Biomedical Analysis Letters. Analysis Letters

International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010

2.1 2,3 Dichloro Benzoyl Cyanide (2,3 DCBC) and survey of. manufactured commonly for the bulk drug industry, few references were

Low-level Determination of 4-Hydrazino Benzoic Acid in Drug Substance by High Performance Liquid Chromatography/Mass Spectrometry

Research Article METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF ELBASVIR AND GRAZOPREVIR BY RP-HPLC

Pharmacophore 2011, Vol. 2 (4), ISSN Pharmacophore. (An International Research Journal)

Development and validation a RP-HPLC method: Application for the quantitative determination of quetiapine fumarate from marketed bulk tablets

Simultaneous estimation and validation of bromhexine and cephalexin in bulk and pharmaceutical dosage form by RP-HPLC method

Development and Validation of Sensitive RP-HPLC Method for the Estimation of Glibenclamide in Pure and Tablet Dosage Forms

Validated RP-HPLC Method for Estimation of Cefprozil in Tablet Dosage Form

SIMULTANEOUS RP HPLC DETERMINATION OF CAMYLOFIN DIHYDROCHLORIDE AND PARACETAMOL IN PHARMACEUTICAL PREPARATIONS.

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

RP-HPLC Method Development and Validation of Dapagliflozin in Bulk and Tablet formulation

Department of Chemistry, JNTUACE, Kalikiri

Development And Validation Of Rp-Hplc Method For Determination Of Velpatasvir In Bulk

Department of Quality Assurance, Luqman College of Pharmacy, GULBARGA (K.S.) INDIA ABSTRACT

Development and validation of RP-HPLC method for determination of marker in polyherbal marketed Kankasava formulations

Development and validation of RP-LC method for lisinopril dihydrate in bulk and its pharmaceutical formulations

penta-hilic UHPLC COLUMNS

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Pelagia Research Library

Volume 6, Issue 2, January February 2011; Article-015

Research Article Available online at

DEVELOPMENT AND VALIDATION OF HPLC METHOD FOR THE ESTIMATION OF NICERGOLINE IN MARKETED FORMULATIONS

Simultaneous estimation of amitryptyline and chlordiazepoxide by RP-HPLC method

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

DEVELOPMENT AND VALIDATION OF NEW RP-HPLC METHOD FOR THE DETERMINATION OF AFLOQUALONE IN HUMAN PLASMA AND FORMULATION

Impact factor: 3.958/ICV: 4.10 ISSN:

Stability-indicating HPLC determination of tolterodine tartrate in pharmaceutical dosage form

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

Liquid Chromatography and Spectroscopic Method for Estimation of Sulphadoxine in Marketed Formulation

Method Development and Validation for the Estimation of Darunavir in Rat Plasma by RP-HPLC

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

CHAPTER - IV. Acharya Nagarjuna University, Guntur 105

RP-HPLC method for simultaneous estimation of amoxicillin and carbocisteine in dosage forms

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Available online Research Article

A Simple, Novel Validated Stability Indicating RP-HPLC method for estimation of Duloxetine HCl in Capsule Pharmaceutical Formulation

STABILITY INDICATING RP HPLC METHOD FOR ANALYSIS OF DORZOLAMIDE HCl IN THE BULK DRUG AND IT S PHARMACEUTICAL DOSAGE FORM

A Reverse Phase Liquid Chromatography Analysis of Citicoline Sodium in Pharmaceutical Dosage Form using Internal Standard Method

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

Development and validation of UV- spectrophotometric method for the estimation of dabigatran etexilate mesylate (dem)

Received: ; Accepted:

Scholars Research Library

Development and Validation of a HPLC Method for Determination of Anastrozole in Tablet Dosage Form

RP-HPLC Estimation of Trospium Chloride in Tablet Dosage Forms

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Validated HPLC Methods

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF GABAPENTIN IN PURE AND PHARMACEUTICAL FORMULATIONS

Development and Validation of GC-FID Method for the Quantification of N-Iodosuccinimide

Reverse Phase High Performance Liquid Chromatography method for determination of Lercanidipine hydrochloride in bulk and tablet dosage form

International Journal of Current Trends in Pharmaceutical Research. International Journal of Current Trends in Pharmaceutical Research

Development of Validated Analytical Method of Mefenamic Acid in an Emulgel (Topical Formulation)

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD TO DETERMINE CINITAPRIDE HYDROGEN TARTARATE IN BULK AND PHARMACEUTICAL FORMULATION

New Validated RP-HPLC Method for Quantification of Rupatadine Fumarate Impurities in Solid Dosage Form Supported By Forced Degradation Studies

Determination of Fexofenadine Hydrochloride in Pharmaceutical Dosage Form By Reverse Phase High Performance Liquid Chromatography Method

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

FLUDEOXYGLUCOSE ( 18 F) INJECTION: Final text for addition to The International Pharmacopoeia (January 2009)

Novus International Journal of Analytical Innovations 2012, Vol. 1, No. 3

DEVELOPMENT AND VALIDATION OF A HPLC METHOD FOR IN-VIVO STUDY OF DICLOFENAC POTASSIUM

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25

Enantiomeric separation of 1, 2, 3, 4-tetrahydro-1-naphthoic acid using chiral stationary Phase

Dissolution study and method validation of alprazolam by high performance liquid chromatography method in pharmaceutical dosage form

Pelagia Research Library

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Int. J. Pharm. Sci. Rev. Res., 30(2), January February 2015; Article No. 09, Pages: 63-68

LUMEFANTRINUM LUMEFANTRINE

Stability indicating RP-HPLC method for determination of azilsartan medoxomil in bulk and its dosage form

Development and validation of stability indicating HPLC method for estimation of related substances in bendamustine hydrochloride

Received: ; Accepted:

penta-hilic UHPLC COLUMNS

Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article. Estimation of zaleplon by a new RP-HPLC method

Validated First Order Derivative Spectroscopic Method for the determination of Stavudine in Bulk and Pharmaceutical Dosage Forms

Validation of Stability-Indicating RP-HPLC Method for the Assay of Ibrutinib in Pharmaceutical Dosage form

J Pharm Sci Bioscientific Res (4): ISSN NO

12 Nicarbazin Nicarbazin (4,4 -dinitro carbanilid (DNC) and 2-hydroxy-4,6-dimethyl pyrimidine (HDP))

STABILITY INDICATING METHOD OF RELATED IMPURITIES IN VENLAFAXINE HYDROCHLORIDE SUSTAINED RELEASE TABLETS

Journal of Chemical and Pharmaceutical Research

CHAPTER - 3 ANALYTICAL PROFILE. 3.1 Estimation of Drug in Pharmaceutical Formulation Estimation of Drugs

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Analysis of PEGylated Proteins with Agilent AdvanceBio SEC Columns

DEVELOPMENT AND VALIDATION OF A RP-HPLC METHOD FOR DETERMINATION OF LOPINAVIR IN BULK AND PHARMACEUTICAL DOSAGE FORM

Available online Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article

Rapid quantification of Chinese medicine Zuo Jin Pill using rapid resolution liquid chromatography

Research Article. Identification and characterization of unknown impurity in zolmitriptan tablets by a sensitive HPLC method

Assay Determination of Tranexamic acid in Pharmaceutical Dosage Form (Tablet) Using HPLC and ELS Detector

Chapter 4: Verification of compendial methods

LC and LC/MS Column Selection Flow Chart

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

CYCLOSERINE Final text for addition to The International Pharmacopoeia. (November 2008) CYCLOSERINUM CYCLOSERINE

International Journal of Research and Reviews in Pharmacy and Applied science.

SIMULTANEOUS ESTIMATION OF MEFENAMIC ACID AND PARACETAMOL IN SUSPENSION FORM BY USING UPLC

Development and Validation of Stability Indicating RP-HPLC Method for the Determination of Anagrelide HCl in Pharmaceutical Formulation

Research Article. Figure 1. Chemical structure of doxofylline. Indonesian J. Pharm. Vol. 24 No. 1 : ISSN-p :

Transcription:

Available online at www.scholarsresearchlibrary.com Scholars Research Library Der Pharmacia Lettre, 2012, 4 (2):591-598 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-5071 USA CODEN: DPLEB4 A Novel LC-ELSD Method for the Quantification of 2-Deoxy D-Glucose Using HILIC Chromatography Lakshmi Narayana. Ch a*, Subrahmanyam. D b and Dubey. P.K c a Daicel Chiral Technologies (India) Pvt Ltd, Hyderabad, India b Laxai Avanthi Laboratories Pvt Ltd, Hyderabad, India c Department of Chemistry, J. N. T. University, Kukatpally, Hyderabad, India _ ABSTRACT A simple and novel method for the direct determination of 2-deoxy D-glucose (2DG) is developed, using a hydrophilic interaction chromatography (HILIC) and evaporative light scattering detection (ELSD). Altech Altima HP HILIC column (250 x 4.6 mm, 5µ particles) was used along with the mobile phase consisted of water and acetonitrile in a linear inverse gradient elution. The proposed method is capable of separating 2DG from its precursor D-Glucal (DGL) and starting material D-Glucose (DGS) with resolution > 3.0. ELSD parameters such as nebuliser temperature and impactor position were found to be critical while detecting DGL. The optimized ELSD parameters were: impactor ON position, nebuliser temperature: 30 C, nitrogen flow rate 1.5 ml/min and gain1. Power regression curves were obtained in the range of 250-750µg/mL with R 2 > 0.999. The percentage recovery of 2DG, DGL and DGS were found to be 99.5±0.7%, 101.1± 2.1, 98.5± 2.2 respectively at 95% confidence interval. The limit of detection (LOD) of DGL and DGS were found to be 20 ng and 15 ng respectively. Key words: HILIC, LC-ELSD, 2-deoxy D-glucose, D- Glucose, D-Glucal. _ INTRODUCTION 2-Deoxy-D-glucose (2DG) is a rare and natural monosaccharide that can be made from D-glucose, D-amino glucose and some amino-polysaccharides [1]. It was first prepared from D-glucose (DGS) in 1922. Chemical structures of 2DG, its precursor D-Glucal (DGL) and its starting material DGS were shown in Fig 1. 2DG is a white crystalline hygroscopic powder. It is odorless, tastes sweet and very soluble in water, partially soluble in hot methanol, ethanol, acetone and butanol. 2DG exhibits various physiological and pharmacological effects on antivirus, anti-cancer and anti-aging [2]. 2DG acts to inhibit the phosphorylation of a glucose molecule that produces glucose-6-phosphate in the glycolysis cycle, therefore inhibiting the production of ATP and can also decrease the temperature in muscle cells. It can restrain viral infections and fermentation, microbes and cancer cell growth. It has great potential in medicine, foods, and cosmetics. 591

DGS DGL 2DG O O O Fig 1. Chemical structures of DGS, DGL and 2DG A HPLC method was reported in the literature for the determination of Glucosamine, an amino derivative of 2DG in pharmaceutical formulations [3] and also a CE method was reported for the analysis of advanced glycation endproducts formed from the reaction of reducing sugars with the amino group of glucosamine [4]. Threshold Pharmaceutical, Inc., USA, has filed a patent for estimating concentration and purity of crystalline and liquid samples of 2DG by HPLC, which involves an ion exchange column and refractive index (RI) detector [5]. Umegae Y et al, reported simultaneous determination of 2DG & DGS in rat serum by HPLC with post column fluorescence derivatisation [6]. To our knowledge, no HPLC method is available in open literature for the direct determination of 2DG, DGS & DGL in bulk. In this paper, we describe a rapid and sensitive HPLC method for the determination of 2DG, DGS & DGL in bulk using hydrophilic interaction chromatography (HILIC) with evaporative light scattering detector (ELSD). HILIC is a technique that was designed for the retention and separation of polar compounds. HILIC is a variation of normal phase chromatography and separates compounds by passing a mostly organic mobile phase over a highly polar stationary phase. Analytes elute in order of increasing polarity i.e., the opposite of traditional reversed phase chromatography. ELSD is increasingly being used in HPLC as a quasi-universal detector eliminating the need for derivatisation of non-absorbing analytes [7]. ELSD operation principle mainly consists of three successive processes: (a) nebulization of chromatographic effluent using an inert gas (e.g. nitrogen), (b) evaporation of mobile phase at relatively low temperature and (c) light scattering by the residual particles, which ideally consist of analytes molecules [8]. MATERIALS AND METDS Pure samples of 2DG, DGL and DGS were purchased from Lancaster. Acetonitrile (HPLC grade) was purchased from Qualigens, India. HPLC grade water was obtained from Milli-Q water purification system (Millipore). Instrumentation The HPLC system used was Agilent 1100 series HPLC connected with Altech 2000ES model ELSD. Data collection was performed with Chemstation software. Method ruggedness was studied on Waters Alliance 2695 XT with ELSD. Data collection was performed with Waters Empower chromatographic manager. Preparation of test solutions The stock solutions of 2DG (5 mg ml -1 ), DGS and DGL (1 mg ml -1 ) were prepared separately by dissolving the appropriate amounts of the substances in mobile phase. Necessary dilutions were made to get the test solutions ranging 250-750 µg ml -1 for 2DG and 10-50 µg ml -1 for DGS and DGL. Chromatographic conditions The chromatographic column used was a 250 x 4.6 mm Altima HP HILIC (Altech) with 5µm particles. The chromatographic elution was accomplished with a mobile phase consisting of water and acetonitrile in a linear inverse gradient mode (%ACN): 0-10 min (90-80%), 10-11 min (80-90%), 11-14 min (90%) at a flow rate of 1.0 ml min -1. The column temperature was maintained at 25 ±1 C and the injection volume was 10µL. The chromatographic column effluent was subjected to ELS detection. Nebulization of the effluent in the ELSD was 592

provided by a stream of nitrogen gas at a flow rate of 1.5mL/min and the nebulized effluent was evaporated at 30 C. The detector gain was set at 1. Fig 2. Chromatographic selectivity of DGS, DGL and 2DG using C18, CN and HILIC columns Detector settings RESULTS AND DISCUSSION Method development In order to separate 2DG, DGS and DGL, C18 and CN phases were tried using a mobile phase consisted of water and acetonitrile in a linear gradient elution, but not successful. Further attempts in mobile phase changes using C18 and CN phases, couldn t yield any satisfactory separations. In view of polar nature of the analytes, a HILIC phase was tried. Altima HP HILIC packing is non bonded high purity silica optimized for HILIC separations. Silica 593

functions as a HILIC packing when small amounts of water are present in the mobile phase. The water creates a layer over the surface of the silica that interacts with polar analytes. In HILIC, a high organic-low aqueous mobile phase is used where the analytes elute in order of increasing hydrophilicity. Increasing the amount of water will elute analytes more quickly. Excellent separation is noticed with Altima HP HILIC column using a mobile phase consisting of water and acetonitrile in a linear but inverse gradient elution. Selectivity chromatograms generated on C18, CN and HILIC phases were shown in Fig. 2. The typical retention times of DGL, 2DG, and DGS were 4.2, 5.5 and 6.2 min. respectively. The chromatographic characteristics were given in Table 1. Table 1. Chromatographic Characteristics of DGS, DGL and 2DG and method validation data DGL 2DG DGS Retention time, tr (min) 4.2 5.5 6.2 Theoretical plates, N 9640 10080 13340 Resolution -- 5.5 3.3 Tailing factor 1.3 1.2 1.3 Slope of exponential calibration 0.552 1.326 0.436 Intercept of exponential calibration 4.586 0.713 11.63 Correlation coefficient 0.994 0.9991 0.990 Range, µg ml -1 5-30 250-750 5-30 Precision, RSD (n=6) 2.5 0.36 2.2 Limit of detection, µg ml -1 2 -- 1.5 Limit of quantitation, µg ml -1 5 -- 4 ELSD can detect all solutes that are less volatile than mobile phase. 2DG and DGS are non volatile compounds, where as DGL is semi volatile and are therefore suitable analytes for ELS detection. Indeed, HILIC chromatography is most favorable condition for ELS detection due to high organic and low aqueous composition of the mobile phases. Two important parameters, nebuliser gas flow rate and drift tube temperature, must be optimized to get best results in ELSD. The gas flow rate determines the size of droplets formed during nebulization. Higher gas flow rates produce smaller droplets, which evaporate more easily than larger droplets. On the other hand, smaller droplets are less effective in light scattering and therefore produce smaller signals than larger droplets. Different gas flow rates ranging 1.5-2.5 ml min -1 were checked and the flow rate at 1.5 ml min -1 was found to be the optimum (Fig 3). 30 25 20 S/N ratio 15 10 5 DGL DGS 0 1 1.5 2 2.5 3 N2 Flow rate (ml min -1 ). Fig 3. Effect of nebuliser gas flow rate on S/N ratio 594

The proper drift tube temperature setting will be based on mobile phase volatility, mobile phase flow rate, nebuliser gas flow rate and analyte volatility. Owing to the semi volatile nature of DGL, different drift tube temperatures ranging 30-55 C were studied and 30 C was found to be the optimum (Fig 4). 30 25 20 S/N ratio 15 10 5 DGL DGS 0 20 30 40 50 60 Temperature ( C). Fig 4. Effect of temperature on S/N ratio Two different impactor positions off and on were possible with Altech 2000 ES detector. Position off (nonvolatile compounds) allows maximum sensitivity by allowing the entire sample stream to reach the optical cell. With impactor position on (semi volatile compounds), a portion of the sample stream is diverted to a drain tube. As illustrated in Fig 5, it was proved that the optimal impactor setting was on. DGL was not detected in Impactor off position due to its semi volatile nature. Method Validation The validation was done according to ICH guidelines [9]. The target analyte concentration of 2DG was fixed as 500 µg ml -1. Specificity of the method was demonstrated by separating DGS and DGL from 2DG. The system precision was assessed by multiple injections of standard solution of 2DG at target analyte concentration. For six injections of the solution, the relative standard deviation (RSD) was 0.4%. Linearity of the method was determined by preparing and analyzing five standard solutions in the range of 250-750 µg ml -1. The peak areas (Y) were correlated to the analyte mass (x) by the well established power regression curve of ELSD response [8] Y = axb => log Y = blog x + log a where a and b are coefficients depending on instrumental parameters, nature and concentration of analyte, gas and liquid flow rates, evaporation temperatures etc. Power regression analysis of peak areas versus concentration data yielded a R 2 > 0.999 for 2DG. Regression line equation was y = 0.713x1.326. Accuracy of the method was determined by analyzing 2DG sample at three different concentrations levels 400, 500 and 600 µg ml -1. The percentage recovery of 2DG was found to be 99.5±0.7% at 95% confidence interval (Table 2). Method ruggedness was studied using different make of instruments specified in Experimental section. Typical chromatogram generated in ruggedness study is shown in Fig 6. 595

Fig 5. Effect of impactor position on DGL detection Table 2. Accuracy in the assay determination of 2DG Taken (µg ) Recovered (µg ) % Recovery % RSD 400.4 394.6 98.6 0.2 395.8 98.9 394.4 98.5 501 503.4 100.5 0.2 503.2 100.4 501.6 100.1 600.2 595.6 99.2 0.7 595.2 99.2 603 100.5 596

Fig 6. Typical selectivity chromatogram generated during ruggedness study Quantification of DGL and DGS Standard addition and recovery experiments were conducted in the presence of 2DG to determine accuracy of the present method for the quantification of DGL and DGS. The study was carried out at 10, 15 and 20 µg ml -1. The recovery of DGL and DGS were calculated from the calibration curve drawn in the concentration range of 5-30 µg ml -1. The calibration equation for DGL and DGS were found to be y = 4.586x0.552 and y = 11.63x0.436 respectively. The percentage recovery of DGL and DGS were found to be 101.1± 2.1 and 98.5± 2.2 respectively at 95% confidence interval (Table 3). Table 3. Recovery results of DGL and DGS Added (µg ) Recovered (µg ) % Recovery % RSD (n=3) DGL 10.1 10.47 103.7 3.5 14.9 15.11 101.4 2.8 20.3 19.9 98 2.5 DGS 9.8 9.46 96.5 3.1 14.8 14.37 97.1 2.9 20.1 20.5 102 2.3 n, Number of determinations The limit of detection (LOD) of DGL and DGS were 2 and 1.5 µg ml -1 respectively for 10µL injection volume. The limit of quantitation (LOQ) of DGL and DGS were 5 and 4 µg ml -1 respectively for 10µL injection volume. CONCLUSION A simple HPLC/ELSD method using HILIC column was described for the direct determination of 2-DG. This method was able to separate the starting material DGS and precursor DGL from 2-DG. Gas flow rate, drift tube temperature and impactor position were found to be critical while optimizing ELSD response. Correlation between ELSD response and analyte concentration was checked using power regression analysis and the accuracy of the method was found to be good. Furthermore, this method is useful for the quantification of DGL and DGS. However, the LOQ of DGL and DGS were limited to 1% and 0.8% of the product concentration respectively. 597

REFERENCES [1] Merck Index, 11th Edition, 2886. [2] Pelicano H, Martin DS, Xu RH, Huang P, Oncogene, 2006, 25,4633 4646. [3] Mahboob Nemati, Hadi Valizadeh, Masood Ansarin, Farank Ghaderi, Journal of AOAC international, 1997, 90,354-357. [4] Udayan Dutta, Joel A. Dain, Analytical Biochemistry, 2005, 343,237-243. [5] Michael Li, Threshold Pharmaceutical Inc, International application No. PCT/US2005/022299, (2005). [6] Umegae Y, Nohta H, Ohkura Y, Chem Pharm Bull (Tokyo), 1990, 38, 963-965. [7] M. Dreux, M. Lafosse, L. Morin-Allory, LCGC Int, 1996, 9, 148 156. [8] M. Lafosse, M. Dreux, L. Morin-Allory, J. Chromatogr, 1987, 404, 95 105. [9] International Conference on Harmonization (ICH), Validation of analytical procedures: text and methodology Q2(R1), 2005. 598