A novel analytical method development and validation for the estimation of simvastatin in bulk and pharmaceutical dosage forms by RP-HPLC

Similar documents
International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010

RP-HPLC Method Development and Validation of Dapagliflozin in Bulk and Tablet formulation

Validated RP-HPLC Method for Estimation of Cefprozil in Tablet Dosage Form

Development and validation a RP-HPLC method: Application for the quantitative determination of quetiapine fumarate from marketed bulk tablets

J Pharm Sci Bioscientific Res (4): ISSN NO

Chapter-4 EXPERIMENTAL WORK BY RP-HPLC

Reverse Phase High Performance Liquid Chromatography method for determination of Lercanidipine hydrochloride in bulk and tablet dosage form

Simultaneous estimation and validation of bromhexine and cephalexin in bulk and pharmaceutical dosage form by RP-HPLC method

Impact factor: 3.958/ICV: 4.10 ISSN:

Stability indicating RP-HPLC method for determination of azilsartan medoxomil in bulk and its dosage form

Research Article METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF ELBASVIR AND GRAZOPREVIR BY RP-HPLC

Development of Validated Analytical Method of Mefenamic Acid in an Emulgel (Topical Formulation)

Development and validation of RP-HPLC method for determination of marker in polyherbal marketed Kankasava formulations

Research Article. Figure 1. Chemical structure of doxofylline. Indonesian J. Pharm. Vol. 24 No. 1 : ISSN-p :

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD TO DETERMINE CINITAPRIDE HYDROGEN TARTARATE IN BULK AND PHARMACEUTICAL FORMULATION

Scholars Research Library

International Journal of Pharma Research and Health Sciences. Available online at

Journal of Pharmaceutical and Biomedical Analysis Letters. Analysis Letters

RP-HPLC Estimation of Trospium Chloride in Tablet Dosage Forms

Development and Validation of Sensitive RP-HPLC Method for the Estimation of Glibenclamide in Pure and Tablet Dosage Forms

DEVELOPMENT AND VALIDATION OF A RP-HPLC METHOD FOR DETERMINATION OF LOPINAVIR IN BULK AND PHARMACEUTICAL DOSAGE FORM

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

Dissolution study and method validation of alprazolam by high performance liquid chromatography method in pharmaceutical dosage form

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF GABAPENTIN IN PURE AND PHARMACEUTICAL FORMULATIONS

Research Article Available online at

Simultaneous Estimation of Metolazone and Spironolactone in Combined Tablet Dosage Form BY UV Spectroscopy.

A Simple, Novel Validated Stability Indicating RP-HPLC method for estimation of Duloxetine HCl in Capsule Pharmaceutical Formulation

Pharmacophore 2011, Vol. 2 (4), ISSN Pharmacophore. (An International Research Journal)

Development and Validation of a HPLC Method for Determination of Anastrozole in Tablet Dosage Form

New Simple UV Spectrophotometric Method for Determination of Mirtazapine in Bulk and pharmaceutical dosage forms

Determination of Fexofenadine Hydrochloride in Pharmaceutical Dosage Form By Reverse Phase High Performance Liquid Chromatography Method

Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article. Estimation of zaleplon by a new RP-HPLC method

A Reverse Phase Liquid Chromatography Analysis of Citicoline Sodium in Pharmaceutical Dosage Form using Internal Standard Method

Estimation and validation of entecavir in bulk and pharmaceutical dosage forms by UV spectrophotometry

Volume 6, Issue 2, January February 2011; Article-015

UV Spectrophotometric Method Development and Validation of Ezetimibe and Simvastatin in Bulk and Pharmaceutical Dosage Form

Novus International Journal of Analytical Innovations 2012, Vol. 1, No. 3

Analytical method development and validation of gabapentin in bulk and tablet dosage form by using UV spectroscopic method

Method Development and Validation Of Prasugrel Tablets By RP- HPLC

Development and Validation of Stability Indicating RP-HPLC Method for the Determination of Anagrelide HCl in Pharmaceutical Formulation

Analytical method development and validation of carvedilol in bulk and tablet dosage form by using uv spectroscopic method as per ich guidelines

Zero And First Order Derivative Spectrophotometric Methods For Determination Of Dronedarone In Pharmaceutical Formulation

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

Development and validation of RP-LC method for lisinopril dihydrate in bulk and its pharmaceutical formulations

STABILITY INDICATING METHOD OF RELATED IMPURITIES IN VENLAFAXINE HYDROCHLORIDE SUSTAINED RELEASE TABLETS

B. Anupama et al. IRJP 2 (1)

DEVELOPMENT AND VALIDATION OF A SPECTROPHOTOMETRIC METHOD FOR DETERMINATION OF DRONEDARONE IN BULK DRUG AND PHARMACEUTICAL FORMULATION

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

Development and validation of stability indicating reverse phase high performance liquid chromatography method for Timolol Maleate

Department of Quality Assurance, Luqman College of Pharmacy, GULBARGA (K.S.) INDIA ABSTRACT

INTERNATIONAL JOURNAL OF UNIVERSAL PHARMACY AND BIO SCIENCES

International Journal of Pharma and Bio Sciences V1(1)2010. HPLC method for analysis of Lercanidipine Hydrochloride in Tablets

Development and validation of RP- HPLC method for determination of ticagrelor in pharmaceutical dosage formulation

Available online Research Article

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

METHOD DEVELOPMENT AND VALIDATION OF RALTEGRAVIR POTASSIUM AND RILPIVIRINE HCL BY HPLC AND HPTLC METHODS

INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND LIFE SCIENCES

Liquid Chromatography and Spectroscopic Method for Estimation of Sulphadoxine in Marketed Formulation

Development And Validation Of Rp-Hplc Method For Determination Of Velpatasvir In Bulk

Available online at Scholars Research Library

Analytical Method Development and Validation of Lafutidine in Tablet dosage form by RP-HPLC

Development and Validation of UV Spectrophotometric Estimation of Diclofenac Sodium Bulk and Tablet Dosage form using Area under Curve Method

Sarojamma. M et al, JGTPS, 2015, Vol. 6(2):

CHAPTER 19 PARACETAMOL + IBUPROFEN

Development and Validation of Stability-Indicating RP-HPLC Method for Estimation of Atovaquone

International Journal of Current Trends in Pharmaceutical Research. International Journal of Current Trends in Pharmaceutical Research

Scholars Research Library. Rapid and sensitive RP-HPLC analytical method development and validation of Pioglitazone hydrochloride

Pelagia Research Library

RP-HPLC Method for Simultaneous Estimation of Atenolol, Hydrochlorothiazide and Losarton in Tablet Dosage form

SIMPLE AND SENSITIVE VALIDATED REVERSE PHASE HPLC-UV METHOD FOR THE DETERMINATION OF LYMECYCLINE IN PHARMACEUTICAL DOSAGE FORMS

Pelagia Research Library

International Journal of PharmTech Research CODEN (USA): IJPRIF, ISSN: , ISSN(Online): Vol.9, No.7, pp , 2016

Journal of Chemical and Pharmaceutical Research, 2017, 9(1): Research Article

Method Development and Validation for the Estimation of Darunavir in Rat Plasma by RP-HPLC

Stability-indicating HPLC determination of tolterodine tartrate in pharmaceutical dosage form

Development and validation of second order derivative methods for quantitative estimation of clopidogrel in bulk and pharmaceutical dosage form

STABILITY INDICATING RP HPLC METHOD FOR ANALYSIS OF DORZOLAMIDE HCl IN THE BULK DRUG AND IT S PHARMACEUTICAL DOSAGE FORM

Development and Validation of Stability Indicating Assay Method of Etodolac by using UV-Visible Spectrophotometer

Validated RP-HPLC Method for the Quantitation of Benfotiamine in Bulk and Tablet Dosage Form

DEVELOPMENT AND VALIDATION OF HPLC METHOD FOR THE ESTIMATION OF NICERGOLINE IN MARKETED FORMULATIONS

Impact factor: 3.958/ICV: 4.10 ISSN:

AND VALIDATION FOR SIMULTENEOUS ESTIMATION OF AMBROXOL HYDROCHLORIDE AND DOXOFYLLINE IN PHARMACEUTICAL DOSAGES FORMS AND BULK DRUGS BY RP-HPLC METHOD

DEVELOPMENT OF AN RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION AND FORCE DEGRADATION OF CEFIXIME AND MOXIFLOXACIN IN BULK AND PHARMACEUTICAL DOSAGE FORM

SIMULTANEOUS RP HPLC DETERMINATION OF CAMYLOFIN DIHYDROCHLORIDE AND PARACETAMOL IN PHARMACEUTICAL PREPARATIONS.

Received: ; Accepted:

Asian Journal of Research in Chemistry and Pharmaceutical Sciences Journal home page:

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

INDICATING LIQUID CHROMATOGRAPHIC METHOD FOR QUANTIFICATION OF CIPROFLOXACIN HCL, ITS RELEATED SUBSTANCE AND TINIDAZOLE IN TABLET DOSAGE FORM

Stability Indicating RP-HPLC Method for Determination of Valsartan in Pure and Pharmaceutical Formulation

PHARMA SCIENCE MONITOR

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Simultaneous estimation of ramipril and valsartan by RP-HPLC method in combined. dosage form

Radhakrishnan K. et al. / International Journal of Pharmacy & Therapeutics, 3(1), 2012, e- ISSN Print ISSN

Validation of Stability-Indicating RP-HPLC Method for the Assay of Ibrutinib in Pharmaceutical Dosage form

Validated First Order Derivative Spectroscopic Method for the determination of Stavudine in Bulk and Pharmaceutical Dosage Forms

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

Absorption correction spectrophotometric method for simultaneous estimation of desvenlafaxine and clonazepam in their combined dosage form

RP-HPLC method for simultaneous estimation of amoxicillin and carbocisteine in dosage forms

CHAPTER - IV. Acharya Nagarjuna University, Guntur 105

Development and Statistical Validation of Spectrophotometric Methods for the Estimation of Nabumetone in Tablet Dosage Form

Transcription:

Available online at www.scholarsresearchlibrary.com Scholars Research Library Der Pharmacia Lettre, 2016, 8 (7):230-236 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-5071 USA CODEN: DPLEB4 A novel analytical method development and validation for the estimation of simvastatin in bulk and pharmaceutical dosage forms by RP-HPLC B. Venkateswara Rao*, S. Vidyadhara, S. Siva Prasad and D. Asheer Department of Pharmaceutical Analysis, Chebrolu Hanumaiah Institute of Pharmaceutical Sciencies, Chandramoulipuram, Chowdavaram, Guntur-522019 ABSTRACT A novel, simple, rapid and precise reverse phase isocratic high performance liquid chromatographic (RP-HPLC) method has been developed for the estimation of Simvastatin in marketed formulations. Estimation of drug in the formulation was done with a C18 column[agilent ODS UG column, 250mm 4.5mm]using mobile phase of composition Acetonitrile:Methanol:Phosphate buffer ph 3.0 in the ratio of (50: 40: 10v / v) and flow rate was 1.0 ml/min and effluent was monitored with UV detection at 238 nm. The retention time of Simvastatin was observed at 4.3min. The developed method was found to be linear over a concentration range of 5-25µg/mL for Simvastatin. The method was validated according to the guidelines of International Conference on Harmonization (ICH) for specificity, linearity, precision, accuracy and robustness. The proposed method was successfully applied in the estimation of commercial formulations. Keywords: Simvastatin, RP-HPLC, Method validation INTRODUCTION Simvastatin belongs to a group of cholesterol lowering lactones known as statins which are among the world s most widely prescribed drugs. Statins lower cholesterol by inhibiting the synthesis of Mavalonic acid, which is a key precursor in cholesterol synthesis [1-3]. Simvastatin is official in Indian Pharmacopoeia. Many analytical methods were traced for the estimation of Simvastatin in combination with other cardiovascular drugs but very few methods were reported on the individual estimation of Simvastatin [4-14]. In present study a simple, sensitive, specific, accurate, precise and economical reverse phase HPLC method was described for the estimation of Simvastatin. MATERIALS AND METHODS Equipment used The chromatographic separation was performed on Agilent 1120 Compact Liquid Chromatographic system integrated with a variable wavelength programmable UV detector and a Rheodyne injector equipped with 20µL fixed loop. A reverse phase Agilent 100-5C 18 Column (250mmx 4.5mm) was used. 230

Reagents and chemicals Simvastatin was obtained as a gift sample from NATCO Pharma Ltd. AR grade potassium dihydrogen phosphate (KH2PO4) and ortho phosphoric acid were procured from RANKEM Chemicals Pvt. Ltd. HPLC grade Acetonitrile, Methanol and double distilled water were procured from Merk India. For the estimation of commercial formulations Simvastatin tablets (Simvas 10, batch no: SVTY0032) manufactured by Micro Labs Ltd, Unit III, Pondicherry, were procured from the local market. Chromatographic conditions Agilent 1120 compact LC chromatographic system, with variable wavelength UV detector and Rheodyne injector with 20µL fixed loop was used for the chromatographic separation. EZ Chrome Elite software was used for data analysis. Chromatographic separation was carried out on a C 18 Column (250mm x 4.5mm) was used for the chromatographic separation at a detection wavelength of 238nm. Mobile phase composition of Acetonitrile: Methanol: Phosphate buffer ph 3.0 in the ratio of (50:40:10 v/v) was selected for elution and same mixture was used in the preparation of standard and sample solutions. Flow rate was adjusted to 1mL/min and the injection volume was 20µL. MEHTOD DEVELOPMENT Spectroscopic determination of Simvastatin indicated that the drug absorbs appreciable at 238nm, hence 238nm was selected as the detection wavelength. Several different mobile phases were used for the initial trials, but optimum results were attained with Acetonitrile: Methanol: Phosphate buffer ph3.0 in the ratio 50:40:10v/v. The peak was symmetric shown in figure 2. Preparation of mobile phase Mobile phase was prepared by mixing Acetonitrile, Methanol and Phosphate Buffer Ph 3.0 in the ratio of (50:40:10v/v) and was initially filtered through 0.45µm Millipore membrane filter and sonicated and degassed for 15 min. Phosphate Buffer ph 3.0: Dissolve 0.136gm of potassium dihydrogen phosphate and 2 ml of triethylamine in 80 ml 0f water, the ph is adjusted to 3.0 with orthophosphoric acid and sufficient quantity of water was added to produce 100mL. Preparation of Standard Stock Solution 10 mg of standard Simvastatin was weighed accurately and transferred in to a 10 ml volumetric flask and dissolved in 5mL of Acetonitrile and made up to the mark with the solvent to obtain a final concentration of 1000µg/mL of Simvastatin (Standard sock solution A). From the above stock solution A, 2.5mL aliquot was pipette in to a 25mL volumetric flask and dissolved in the solvent and made up to the mark with the mobile phase to obtain a final concentration of 10025µg/mL of Simvastatin (Working stock solution B). Preparation of sample stock solution The contents of twenty marketed Simvas tablets were taken and finely powdered. A mass equivalent to 10mg of Simvastatin was transferred to a 10mL volumetric flask and dissolved in 5mL of the Acetonitrile. The solution was kept for sonication for 15min. The solution was made up to the mark with the solvent and filtered through a 0.4525µ membrane filter (Sample stock solution A). 1mL aliquot of the above solution was transferred to a 10mL volumetric flask and diluted to the mark with the mobile phase to obtain a concentration of 10025µg/mL (Working sample stock solution B). Optimization of HPLC method The HPLC method was optimized with an aim to develop an accurate and precise method for the estimation of Simvastatin in pharmaceutical dosage forms. For the method optimization, different mobile phases were tried but acceptable retention times, theoretical plates and good resolution were observed with Acetonitrile, Methanol and Phosphate Buffer ph 3.0 (50:40:10 v/v) using Agilent 100-5C 18 Column (250mmx 4.5mm). VALIDATION OF RP-HPLC METHOD Validation of the optimized method was performed according to the ICH Q2 (B) guidelines. 231

System suitability System suitability was carried out with six injections of solutions of 100% concentration having 25µg/ml of Simvastatin into the chromatographic system. Number of theoretical plates (N) obtained and calculated tailing factor (T), were reported in table 1. Linearity To establish the linearity of proposed method, appropriate aliquots were pipette out from working stock solution A were to a series of 10ml volumetric flasks and the volume was made up to the mark with mobile phase to obtain final concentrations ranging from 5-25µg/ml of Simvastatin. Three replicates per each concentration were injected and Peak areas of the above solutions were reported. Calibration curves were plotted with observed peak areas against concentration followed by the determination of regression equations and calculation of the correlation coefficients. The calibration curve was shown in Figure 3 and their corresponding linearity parameters were given in table 2. Limit of Detection (LOD) and limit of Quantitation (LOQ) The LOD and LOQ were calculated from the slope (s) of the calibration plot and the standard deviation (SD) of the peak areas using the formulae LOD = 3.3 σ/s and LOQ = 10σ/s. The results were given in table 2. Accuracy To ensure the reliability and accuracy of the method recovery studies were carried out by standard addition method. A known quantity of pure drug was added to pre-analysed sample and contents were reanalysed by the proposed method and the percent recovery was reported. The results were given in table 3. Precision The repeatability of the method was verified by calculating the %RSD of six replicate injections of 100% concentration (25µg/ml) on the same day. The results were given in table 4. Specificity Specificity of a method was determined by testing standard substances against potential interferences. The method was found to be specific when the test solution was injected and no interferences were found because of the presence of excipients. Robustness Robustness of the method was verified by altering the chromatographic conditions like mobile phase composition, flow rate, detection wavelength, etc and the % RSD should be reported. Small changes in the operational conditions were allowed and the extent to which the method was robust was determined. A deviation of ±2 nm in the detection wavelength and ±0.1 ml/min in the flow rate, were tried individually. A solution of 100% test concentration with the specified changes in the operational conditions was injected to the instrument in triplicate. %RSD was reported in table 5. Assay of marketed formulation 20µl of sample solution of concentration 25µg/ml was injected into the chromatographic system and the peak response was measured. The solution was injected three times into the column. The amount present in each tablet was calculated by comparing the areas of standards with the test sample. A typical chromatogram of test solution containing 25µg/ml of Simvastatin was shown in figure 4. The results were shown in table 6. 232

Fig 1: Chemical Structure of Simvastatin Fig 2: A typical chromatogram of standard solution containing 25µg/mL of Simvastatin Peak area 18000000 16000000 14000000 12000000 10000000 8000000 6000000 4000000 y=638288x+223451 R²=0.999 0 10 20 30 Concentration µg/ml Fig 3: Calibration curve of Simvastatin 233

Fig 4: A Typical chromatogram for assay of marketed formulation containing 25 µg/ml of Simvastatin Table 1: system suitability parameters for Simvastatin (n=5) S.NoParameters Results 1 No. of theoretical plates 12412 2 Tailing factor 0.45 3 Retention time 4.3+0.01 4 %RSD 0.556 Table 2: Results for linearity of Simvastatin (n=3) Parameters Values Linearity range 5-25µg/mL Slope 638288 Intercept 223451 Correlation coefficient 0.999 Regression equation y=638228x+223451 Limit of Detection 0.21 µg/ml Limit of Quantitation 0.63µg/ml Table 3: Results for accuracy of Simvastatin (n=3) Amount added (µg/ml) % Recovery Level (%w/w) Mean peak areaamount found (µg/ml) Recovery Standard test (%w/w) %RSD 80 4 5 6070496 9.15 101.77 1.64 100 5 5 6589778 9.974 99.74 0.75 120 6 5 7298697 11.08 100.77 0.685 Mean recovery(%w/w) 99.74-101.77 Table 4: Results for Precision of Simvastatin (n=6) Precision Parameters Inter-day Intra-day Day1Day2 Day3 %RSD 0.562 0.48 1.87 1.89 Table 5: Results for Robustness of Simvastatin (n=3) Parameters Rt(min) %RSD 236nm 4.36 0.69 Wavelength + 2nm 240nm 4.33 0.324 Flow rate +0.2ml/min0.8mL/min 4.9 1.35 1.2mL/min 4.1 1.19 234

Table 6: Results for assay (n=3) of marketed formulation (SIMVAS) Drug Labeled claim(mg) Amount found(mg)percentage purity Simvastatin 10 9.81 98.1 RESULTS AND DISCUSSION After a number of trials with mobile phases of different composition, Acetonitrile, Methanol and phosphate buffer ph 3.0, in the ratio of 50:40:10v/v was selected as mobile phase because of better resolution and symmetrical peaks. Simvastatin showed appreciable absorbance at 238 nm when determined spectrophotometrically and hence it was selected as the detection wavelength. The optimized chromatogram of Simvastatin was shown in Figure 2. System suitability was carried out by injecting 5 replicate injections of 100% test concentration, number of theoretical plates, HETP and resolution were satisfactory. The chromatogram confirms the presence of Simvastatin at 4.3.0min without any interferences. The parameters were given in table 1. Concentration range of 5-25µg/mL was found to be linear with correlation coefficient of 0.999. The results were given in table 2. The limit of detection was found to be 0.21µg/ml and limit of quantitation was found to be 0.63µg/ml. The values were represented in table 2. Accuracy of the method was verified by performing recovery studies by standard addition method. The percent recovery of the standard added to the pre-analysed sample was calculated and it was found to be 99.74-101.77%w/w. The values obtained were given in table 3. The proposed method was found to be precise and reproducible with %RSD of 1.89.and it was reported in table 4. The method was found to be robust after changing the conditions like detection wavelength (±2nm) and flow rate (±0.2ml). %RSD was calculated for each variation and reported. Values obtained were given in table 6 and 5. The method was found to be specific after verifying the chromatograms showing no interference of the excipients present. Hence, the method was well suitable for the estimation of commercial formulation. Values obtained were given in table 6. CONCLUSION The proposed RP-HPLC method was validated as per the International Conference on Harmonisation (ICH) Q2B Guidelines, and was found to be applicable for routine quantitative analysis of Simvastatin by RP-HPLC using UV detector in Pharmaceutical dosage forms. The results of linearity, precision, accuracy and specificity, were proved to be within the limits. The method provides selective quantification of Simvastatin with no interference from other formulation excipients. The proposed method was highly sensitive, reproducible, reliable, rapid, robust and specific. Therefore, this method can be employed in quality control to estimate the amount of Simvastatin in bulk and in pharmaceutical dosage forms. Acknowledgement The authors are thankful to the NATCO Pharma Ltd. for providing gift sample of Simvastatin and also to the management of Chebrolu Hanumaiah Institute of Pharmaceutical Sciences, Chowdavaram, Guntur for providing facilities and great support to carry out the research work. REFERENCES [1] Indian Pharmacopoeia, Vol.III, 2010, 2103-2105. [2] Lacy Charles.F, LoraL. Armstrong, MortonP. Goldman, Leonard L.Lance. Lexi-Comp s Drug Information Hand book International., 13 th Edn. 2005, 905-907. [3] ICH Harmonized Tripartite Guideline, Validation of Analytical Procedure Methodology, Q2B, 1996, 1-8. 235

[4] Alihazeem, Sami Nazzal, Journalof Pharmaceutical and Biomedical Analysis, 2009, 4(2), 137-141. [5] Jat R. K, Sharma S, Chipa RC, Singh Rambir and Alam Imran, Journal of Drug Delivery and Therapeutics, 2012, 2(3), 121-124. [6] Rahman Mujeeb U.R, Gazala Praveen, International Journal of Pharmaceutical Research and Development, 2010, 2(9), 56-62. [7] Srinivas. C, Abdul Bari, Padmanabha Rao, International Journal of Pharmacy and Pharmaceutical Sciences, 2012, 4(1), 398-403. [8] Joshi H.V., J.K.Patel and Lata Kothapalli, Der Pharma Chemica, 2010, 2(2), 152-156. [9] A.Ravi Varma, J.V.Shanmukha Kumar and S.Mutta Reddy, Der Pharmacia Lettre, 2015, 7(8), 204-212. [10] Praveen Kumar S.N, Bhadre Gowda D.G., Journal of Chemical and Pharmaceutical Research, 2012, 4(5), 2404-408. [11] Lucie Novakova, Dalibar Sakinsky, Petr Solich, Tr AC Trends in Analytical Chemistry, 2008, 27(4), 352-367. [12] L. Guzik, W.Mrozik, W.Kamysz, Croatica Chemica Acta, 20101, 83(4), 371-377. [13] J.R.Jain, D.R. Shah, S.A.Shah, R.S.Chanhan, Der Pharma Chemica, 2011, 3(4), 245-252. [14] Srelakshmi V, Uma Maheswara Rao. V, Pugazhendly.S, Sushant. K, Srinivastava, Sunitha.M, American Journal of Pharmatech Research, 2013, 3(5), 370-377. 236