Measurement of transverse Emittance

Similar documents
Measurement of Beam Profile

Beam Diagnostics and Instrumentation JUAS, Archamps Peter Forck Gesellschaft für Schwerionenforschnung (GSI)

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Progress towards slice emittance measurements at PITZ. Raffael Niemczyk for the PITZ team, Würzburg, March 20 th 2018

Beam Diagnostics Lecture 3. Measuring Complex Accelerator Parameters Uli Raich CERN AB-BI

Research Article Emittance Measurement for Beamline Extension at the PET Cyclotron

Diagnostic Systems for Characterizing Electron Sources at the Photo Injector Test Facility at DESY, Zeuthen site

arxiv: v1 [physics.ins-det] 15 Jan 2013

Enhancing the accelerated beam current in the booster synchrotron by optimizing the transport line beam propagation

Transverse emittance measurements on an S-band photocathode rf electron gun * Abstract

UPGRADE OF THE HIT INJECTOR LINAC-FRONTEND

UPGRADE OF THE HIT INJECTOR LINAC-FRONTEND

The FAIR Accelerator Facility

slhc-project-report-0029

Transverse Beam Optics of the FLASH Facility

Introduction to electron and photon beam physics. Zhirong Huang SLAC and Stanford University

HIGH CURRENT PROTON BEAM INVESTIGATIONS AT THE SILHI-LEBT AT CEA/SACLAY

Simulation of transverse emittance measurements using the single slit method

Diagnostics Requirements for the ARIEL Low Energy Beam Transport

BEAM DYNAMICS ISSUES IN THE SNS LINAC

COMPARISON OF TRACKING SIMULATION WITH EXPERIMENT ON THE GSI UNILAC

HITRAP Low Energy Diagnostics and Emittance Measurement

ThomX Machine Advisory Committee. (LAL Orsay, March ) Ring Beam Dynamics

Emittance and energy spread measurements of relativistic electrons from laser-driven accelerator

IFMIF mini-workshop on Beam Instrumentation. Ciemat, Madrid (Spain) 2-3 July 2007

DIAGNOSTIC TEST-BEAM-LINE FOR THE MESA INJECTOR

Measurement of wakefields in hollow plasma channels Carl A. Lindstrøm (University of Oslo)

Development of the UNILAC towards a Megawatt Beam Injector

THE SUPER-FRS PROJECT AT GSI

arxiv: v2 [physics.acc-ph] 21 Jun 2017

A pepper pot emittance device for 8 kev/u light ion beams Marion RIPERT

Upgrade of the HIT Injector Linac-Frontend

SLS at the Paul Scherrer Institute (PSI), Villigen, Switzerland

Linear Collider Collaboration Tech Notes

Investigations into Ion Beam Emittance and Profile Monitoring

Proposal to convert TLS Booster for hadron accelerator

σ ε ω 1 /σ ω ε α=ω 2 /ω 1

Light Source I. Takashi TANAKA (RIKEN SPring-8 Center) Cheiron 2012: Light Source I

Status Report on the Survey and Alignment efforts at DESY

The SARAF 40 MeV Proton/Deuteron Accelerator

3. Synchrotrons. Synchrotron Basics

Bernhard Holzer, CERN-LHC

A Multi-beamlet Injector for Heavy Ion Fusion: Experiments and Modeling

LECTURE 18. Beam loss and beam emittance growth. Mechanisms for beam loss. Mechanisms for emittance growth and beam loss Beam lifetime:

Transverse dynamics Selected topics. Erik Adli, University of Oslo, August 2016, v2.21

UPGRADE AND COMMISSIONING OF THE PIAVE-ALPI ECR INJECTOR AT LNL

Transverse Profiles. Enrico Bravin CERN. CAS - Dourdan, France 28 May 6 June 2008

E. Wilson - CERN. Components of a synchrotron. Dipole Bending Magnet. Magnetic rigidity. Bending Magnet. Weak focusing - gutter. Transverse ellipse

Notes on the HIE-ISOLDE HEBT

LCLS-II Beam Stay-Clear

NIRS. Outline HIMAC. Introduction Gantry developments. Superconducting magnets Construction of gantry structure. Future project.

Development of beam delivery systems for proton (ion) therapy

SPACE CHARGE EFFECTS AND FOCUSING METHODS FOR LASER ACCELERATED ION BEAMS

Chromatic Corrections for the LCLS-II Electron Transport Lines

Practical Lattice Design

Low energy high brilliance beam characterization

Development of Large Scale Optimization Tools for Beam Tracking Codes

D. Brandt, CERN. CAS Frascati 2008 Accelerators for Newcomers D. Brandt 1

Microbunching Workshop 2010 March 24, 2010, Frascati, Italy. Zhirong Huang

$)ODW%HDP(OHFWURQ6RXUFHIRU/LQHDU&ROOLGHUV

Beam Diagnostics. Measuring Complex Accelerator Parameters Uli Raich CERN BE-BI

Uniform transverse beam profile with a new type nonlinear magnet

The Booster has three magnet systems for extraction: Kicker Ke, comprising two identical magnets and power supplies Septum Se

Introduction to linear Beam Optics

Transverse Phase Space Studies in TTF. Photoinjector during Run 00-01: A. Comparison between Simulation and. A. Cianchi,

Beam Dynamics. D. Brandt, CERN. CAS Bruges June 2009 Beam Dynamics D. Brandt 1

ASTRA BASED SWARM OPTIMIZATIONS OF THE BERLinPro INJECTOR

Betatron Matching and Dispersion Matching

Emittance preservation in TESLA

PIP-II Injector Test s Low Energy Beam Transport: Commissioning and Selected Measurements

The Accelerator System for ReA3 the New Re-accelerated RIBs Facility at MSU

Beam Transfer Lines. Brennan Goddard CERN

STATUS REPORT ON STORAGE RING REALIGNMENT AT SLRI

LCLS Injector Prototyping at the GTF

PHY410 Optics Exam #3

4. Statistical description of particle beams

Experimental study of nonlinear laser-beam Thomson scattering

FURTHER UNDERSTANDING THE LCLS INJECTOR EMITTANCE*

The Compact Muon Beam Line

2.6 Electron transport lines

The accelerators at LNS - INFN and diagnostics aspects of the radioactive beams

Optimization of the SIS100 Lattice and a Dedicated Collimation System for Ionisation Losses

The ISIS Penning H - SPS and Diagnostic Developments at RAL

ILC Beam Dynamics Studies Using PLACET

A Project to convert TLS Booster to hadron accelerator 1. Basic design. 2. The injection systems:

SRF GUN CHARACTERIZATION - PHASE SPACE AND DARK CURRENT MEASUREMENTS AT ELBE*

STUDY OF THE TRANSVERSE BEAM EMITTANCE OF THE BERN MEDICAL CYCLOTRON

A Transverse Profile Imager for SwissFEL Rasmus Ischebeck

A high intensity p-linac and the FAIR Project

CERN EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH

arxiv: v3 [physics.acc-ph] 21 Mar 2018

GEANT4 Emittance Diagnostics Simulations for the ERL Injector Prototype

Emittance and Quantum Efficiency Measurements from a 1.6 cell S- Band Photocathode RF Gun with Mg Cathode *

MISMATCH BETWEEN THE PSB AND CPS DUE TO THE PRESENT VERTICAL RECOMBINATION SCHEME

Part V Undulators for Free Electron Lasers

Practical Lattice Design

Linac Beam Dynamics Code Benchmarking

Studies of Beam Halo Formation in the 12 GeV CEBAF Design

First propositions of a lattice for the future upgrade of SOLEIL. A. Nadji On behalf of the Accelerators and Engineering Division

PULSE-TO-PULSE TRANSVERSE BEAM EMITTANCE CONTROLLING FOR MLF AND MR IN THE 3-GeV RCS OF J-PARC

Transcription:

Measurement of transverse Emittance The emittance characterizes the whole beam quality, assuming linear behavior as described by second order differential equation. 1 It is defined within the phase space as: ε x = dxdx' π A 1 Or using the density function ρ(x,x ) via: ε x = ρ( x, x' ) dxdx' π The measurement is based on determination of: either profile width x and angular width x at one location or x at different locations and linear transformations. Different devices are used at transfer lines: Lower energies E kin < 100 MeV/u: slit-grid device, pepper-pot (suited in case of non-linear forces). All beams: Quadrupole variation, three grid method using linear transformations (not well suited in the presence of non-linear forces) Synchrotron: lattice functions results in stability criterion 2 1 2 p y beam width delivers emittance: ε x = x D( s) and ε y = βx( s) p β y( s), 2003, A dedicated proton accelerator for 1p-physics at the future Transverse GSI facilities Emittance Measurement

Basic Equations for transverse Emittance Beam matrix at one location: The value of emittance is: = 11 12 12 22 = ε β α α γ with x = x x' ε x = det = 11 22 2 12 For the profile and angular measurement: x = 11 = εβ and x' = 22 = εγ Using the Twiss Parameters: 2 ε = γx + 2αxx' + βx' x 2 The density function for a Gaussian distribution:, 2003, A dedicated proton accelerator for 2p-physics at the future Transverse GSI facilities Emittance Measurement

The Emittance for non-gaussian Beams The beam distribution can be non-gaussian. Examples: proton beams behind ion source space charged dominated beams at LINAC and synchrotron cooled beams at storage rings. General description of emittance: ε rms = x 2 2 x' xx' 2, 2003, A dedicated proton accelerator for 3p-physics at the future Transverse GSI facilities Emittance Measurement

The Slit-Grid Measurement Device Slit-Grid: Direct determination of position and angle distribution. Used for protons/heavy ions with E kin < 100 MeV/u range R < 1 cm. Slit: position P(x) with typical width: 0.1 to 0.5 mm Distance: 10 cm to 1 m (depending on beam velocity) SEM-Grid: angle distribution P(x ), 2003, A dedicated proton accelerator for 4p-physics at the future Transverse GSI facilities Emittance Measurement

Result of an Slit-Grid Emittance Measurement Result for a beam behind ion source: here aberration in quadrupoles due to large beam size different evaluation and plots possible Contour plot can monitor any 1-dim distribution 3-dim plot Low energy ion beam: well suited for emittance showing space-charge effects or aberrations., 2003, A dedicated proton accelerator for 5p-physics at the future Transverse GSI facilities Emittance Measurement

The Resolution of a Slit-Grid Device The width of the slit d slit gives the resolution in space x = d slit. The angle resolution is x = (d slit + 2r wire )/d discretization element x x. By scanning the SEM-grid the angle resolution can be improved. Problems for small beam sizes or parallel beams. For pulsed LINACs: Only one measurement each pulse long measuring time required., 2003, A dedicated proton accelerator for 6p-physics at the future Transverse GSI facilities Emittance Measurement

The Pepperpot Emittance Device For pulsed LINAC: Measurement within one pulse is an advantage If horizontal and vertical direction coupled 2-dim evaluation required (e.g. for ECR ion source) Example GSI-LINAC: Pepper-pot: 15 15 holes with Ø0.1mm on a 50 50 mm 2 copper plate Distance: pepper-pot-screen: 25 cm Data acquisition: high resolution CCD Good spatial resolution if many holes are illuminated. Good angle resolution only if spots do not overlap. Readout by screen sometimes doubtful (!), 2003, A dedicated proton accelerator for 7p-physics at the future Transverse GSI facilities Emittance Measurement

Result of a Pepperpot Emittance Measurement Example: Ar 1+ ion beam at 1.4 MeV/u, screen image from single shot at GSI: Data analysis: Projection on horizontal and vertical plane analog to slit-grid., 2003, A dedicated proton accelerator for 8p-physics at the future Transverse GSI facilities Emittance Measurement

The Artist View of a Pepperpot Emittance Device, 2003, A dedicated proton accelerator for 9p-physics at the future Transverse GSI facilities Emittance Measurement

Emittance Measurement by Quadrupole Variation From a profile determination, the emittance can be calculated via linear transformation, if a well known and constant distribution (e.g. Gaussian) is assumed. The beam width x max and x 2 max = 11 (1, k) is measured, matrix R(k) describes the focusing., 2003, A dedicated proton accelerator for 10p-physics at the future Transverse GSI facilities Emittance Measurement

Some Examples for linear Transformations, 2003, A dedicated proton accelerator for 11p-physics at the future Transverse GSI facilities Emittance Measurement

Measurement of transverse Emittance, 2003, A dedicated proton accelerator for 12p-physics at the future Transverse GSI facilities Emittance Measurement

Measurement of transverse Emittance Example: The beam width measured at GSI-LINAC by SEM-grid:, 2003, A dedicated proton accelerator for 13p-physics at the future Transverse GSI facilities Emittance Measurement

The Three Grid Method for Emittance Measurement Instead of quadrupole variation, the beam width is measured at different locations: The procedure is: Beam width x(i) measured at the locations s i beam matrix element x 2 (i) = 11 (i). The transfer matrix R(i) is known. (without dipole a 3 3 matrix.) The transformations are: (i) = R(i)(0)R T (i) redundant equations:, 2003, A dedicated proton accelerator for 14p-physics at the future Transverse GSI facilities Emittance Measurement

Results of a Three Grid Method Measurement Solution: Solving the linear equations like for quadrupole variation or fitting the profiles with linear optics code (e.g. TRANSPORT, WinAgile, MadX). Example: The hor. and vert. beam envelope and the beam width at a transfer line: Assumptions: constant emittance, in particular no space-charge broadening 100 % transmission i.e. no loss due to vacuum pipe scraping no misalignment, i.e. beam center equals center of the quadruples., 2003, A dedicated proton accelerator for 15p-physics at the future Transverse GSI facilities Emittance Measurement

Summary for transverse Emittance Measurment Emittance measurements are very important for comparison to theory. It includes size (value of ε) and orientation in phase space ( ij or α, β and γ) (three independent values) Techniques for transfer lines (synchrotron: width measurement sufficient): Low energy beams direct measurement of x- and x -distribution Slit-grid: movable slit x-profile, grid x -profile Pepper-pot: holes x-profile, scintillation screen x -profile All beams profile measurement + linear transformation: Quadrupole variation: one location, different setting of a quadrupole Three grid method : different locations Assumptions: well aligned beam, no steering no emittance blow-up due to space charge., 2003, A dedicated proton accelerator for 16p-physics at the future Transverse GSI facilities Emittance Measurement