Advanced Control of a PMSG Wind Turbine

Similar documents
PI/FL Based On PMSG for Wind Turbine Used in Wind Energy Conversion System

NONLINEAR MPPT CONTROL OF SQUIRREL CAGE INDUCTION GENERATOR-WIND TURBINE

Available online at ScienceDirect. Procedia Technology 25 (2016 )

Q-V droop control using fuzzy logic and reciprocal characteristic

Control of Wind Turbine Generators. James Cale Guest Lecturer EE 566, Fall Semester 2014 Colorado State University

Comparative Analysis of an integration of a Wind Energy Conversion System of PMSG and DFIG Models Connected to Power Grid

RamchandraBhosale, Bindu R (Electrical Department, Fr.CRIT,Navi Mumbai,India)

Simulations and Control of Direct Driven Permanent Magnet Synchronous Generator

Robust Speed Controller Design for Permanent Magnet Synchronous Motor Drives Based on Sliding Mode Control

Fuzzy optimum opertaing of a wind power pumping system

Speed Control of PMSM Drives by Using Neural Network Controller

Generators for wind power conversion

ADVANCES in NATURAL and APPLIED SCIENCES

International Journal of Emerging Technology and Advanced Engineering Website: (ISSN , Volume 2, Issue 5, May 2012)

Research on Permanent Magnet Linear Synchronous Motor Control System Simulation *

Robust Controller Design for Speed Control of an Indirect Field Oriented Induction Machine Drive

Open Access Permanent Magnet Synchronous Motor Vector Control Based on Weighted Integral Gain of Sliding Mode Variable Structure

MODELING AND SIMULATION OF ROTOR FLUX OBSERVER BASED INDIRECT VECTOR CONTROL OF INDUCTION MOTOR DRIVE USING FUZZY LOGIC CONTROL

Reduced Size Rule Set Based Fuzzy Logic Dual Input Power System Stabilizer

Dynamic Analysis of Grid Connected Wind Farms Using ATP

REAL TIME CONTROL OF DOUBLY FED INDUCTION GENERATOR. Benmeziane Meriem, Zebirate Soraya, Chaker Abelkader Laboratory SCAMRE, ENPO, Oran, Algeria

Mathematical analysis of tip speed ratio of a wind turbine and its effects on power coefficient

Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science Electric Machines

Three phase induction motor using direct torque control by Matlab Simulink

DIRECT TORQUE CONTROL OF THREE PHASE INDUCTION MOTOR USING FUZZY LOGIC

FUZZY LOGIC APPROACH OF SENSORLESS VECTOR CONTROL OF INDUCTION MOTOR USING EFFICIENCY OPTIMIZATION TECHNIQUE

Adaptive Control of Variable-Speed Variable-Pitch Wind Turbines Using RBF Neural Network

Modeling of Permanent Magnet Synchronous Generator for Wind Energy Conversion System

Modeling and Simulation of Indirect Field Oriented Control of Three Phase Induction Motor using Fuzzy Logic Controller

CONTROL ASPECTS OF WIND TURBINES. Faizal Hafiz, Wind Energy Research Group, SET Center

Linearizing control input-output of a wind turbine permanent magnet synchronous Riad AISSOU #1, Toufik REKIOUA #2

Sunita.Ch 1, M.V.Srikanth 2 1, 2 Department of Electrical and Electronics, Shri Vishnu engineering college for women, India

ENHANCEMENT MAXIMUM POWER POINT TRACKING OF PV SYSTEMS USING DIFFERENT ALGORITHMS

Sensorless DTC-SVM of Induction Motor by Applying Two Neural Controllers

A Study on Performance of Fuzzy And Fuzyy Model Reference Learning Pss In Presence of Interaction Between Lfc and avr Loops

3 d Calculate the product of the motor constant and the pole flux KΦ in this operating point. 2 e Calculate the torque.

Direct Torque Control of Three Phase Induction Motor Using Fuzzy Logic

COMPARISON OF DAMPING PERFORMANCE OF CONVENTIONAL AND NEURO FUZZY BASED POWER SYSTEM STABILIZERS APPLIED IN MULTI MACHINE POWER SYSTEMS

A simple model based control of self excited induction generators over a wide speed range

FUZZY LOGIC CONTROL of SRM 1 KIRAN SRIVASTAVA, 2 B.K.SINGH 1 RajKumar Goel Institute of Technology, Ghaziabad 2 B.T.K.I.T.

Variable Sampling Effect for BLDC Motors using Fuzzy PI Controller

SPEED CONTROL OF THE DOUBLY FED INDUCTION GENERATOR APPLIED TO A WIND SYSTEM

Fuzzy Controller of Switched Reluctance Motor

Mini-project report. Modelling and control of a variablespeed subsea tidal turbine equipped with permanent magnet synchronous generator.

Performance Of Power System Stabilizerusing Fuzzy Logic Controller

An ANN based Rotor Flux Estimator for Vector Controlled Induction Motor Drive

Effects of the Controller Performance of DFIG on its Inertia Response

A Novel Three-phase Matrix Converter Based Induction Motor Drive Using Power Factor Control

Dynamic Modeling of Surface Mounted Permanent Synchronous Motor for Servo motor application

Dynamic Behavior of Three phase Inductions Motors as Loads in an Electric Power System with Distributed Generation, a Case of Study.

1439. Numerical simulation of the magnetic field and electromagnetic vibration analysis of the AC permanent-magnet synchronous motor

Introduction to Synchronous. Machines. Kevin Gaughan

Nonlinear Control of Variable wind Speed Conversion System Based on a Squirrel Cage Induction Generator (SCIG)

Modelling of Closed Loop Speed Control for Pmsm Drive

Block seminar Modeling and control of wind turbine systems: An introduction

FUZZY LOGIC BASED ADAPTATION MECHANISM FOR ADAPTIVE LUENBERGER OBSERVER SENSORLESS DIRECT TORQUE CONTROL OF INDUCTION MOTOR

Sensorless Control for High-Speed BLDC Motors With Low Inductance and Nonideal Back EMF

Optimization of PI Parameters for Speed Controller of a Permanent Magnet Synchronous Motor by using Particle Swarm Optimization Technique

Robust Control For Variable-Speed Two-Bladed Horizontal-Axis Wind Turbines Via ChatteringControl

Performance Evaluation of DFIG to Changes in Network Frequency

Inertia Identification and Auto-Tuning. of Induction Motor Using MRAS

Mathematical Modelling of an 3 Phase Induction Motor Using MATLAB/Simulink

FUZZY LOGIC CONTROL DESIGN FOR ELECTRICAL MACHINES

A NOVEL CONTROL APPROACH FOR SWITCHED RELUCTANCE MOTORS BASED ON FUZZY LOGIC AND PARTICLE SWARM OPTIMIZATION TECHNIQUES

PERFORMANCE ENHANCEMENT OF DIRECT TORQUE CONTROL OF INDUCTION MOTOR USING FUZZY LOGIC

PERFORMANCE ANALYSIS OF DIRECT TORQUE CONTROL OF 3-PHASE INDUCTION MOTOR

DESIGN OF ROBUST CONTROL SYSTEM FOR THE PMS MOTOR

Secondary Frequency Control of Microgrids In Islanded Operation Mode and Its Optimum Regulation Based on the Particle Swarm Optimization Algorithm

ISSN: (Online) Volume 2, Issue 2, February 2014 International Journal of Advance Research in Computer Science and Management Studies

MATLAB SIMULINK Based DQ Modeling and Dynamic Characteristics of Three Phase Self Excited Induction Generator

FUZZY LOGIC CONTROL Vs. CONVENTIONAL PID CONTROL OF AN INVERTED PENDULUM ROBOT

An improved deadbeat predictive current control for permanent magnet linear synchronous motor

Comparison by Simulation of Various Strategies of Three Level Induction Motor Torque Control Schemes for Electrical Vehicle Application

Comparative Study of Speed Control of Induction Motor Using PI and Fuzzy Logic Controller

A Novel Approach to Permanent Magnet Linear Synchronous Motor Parameter Estimation

A Simplified State Model for Wind Turbines

PARAMETER SENSITIVITY ANALYSIS OF AN INDUCTION MOTOR

International Journal of Advance Engineering and Research Development SIMULATION OF FIELD ORIENTED CONTROL OF PERMANENT MAGNET SYNCHRONOUS MOTOR

Anakapalli Andhra Pradesh, India I. INTRODUCTION

A New Model Reference Adaptive Formulation to Estimate Stator Resistance in Field Oriented Induction Motor Drive

Application of Hyper-Fuzzy Logic Type -2 in Field Oriented Control of Induction Motor with Broken Bars

Predictive Control Strategy for DFIG Wind Turbines with Maximum Power Point Tracking Using Multilevel Converters

MANAGEMENT FLOW CONTROL ROTOR INDUCTION MACHINE USING FUZZY REGULATORS

Design and Analysis of Speed Control Using Hybrid PID-Fuzzy Controller for Induction Motors

Sensorless Sliding Mode Control of Induction Motor Drives

Parameter Prediction and Modelling Methods for Traction Motor of Hybrid Electric Vehicle

Application of Virtual Synchronous Generator in Solar Power Generation

A New Predictive Control Strategy Dedicated to Salient Pole Synchronous Machines

Index Terms Magnetic Levitation System, Interval type-2 fuzzy logic controller, Self tuning type-2 fuzzy controller.

PERFORMANCE OF SENSORLESS CONTROL OF PERMANENT MAGNET SYNCHRONOUS GENERATOR IN WIND TURBINE SYSTEM*

Fuzzy Logic Control for Half Car Suspension System Using Matlab

Mathematical Modelling of Permanent Magnet Synchronous Motor with Rotor Frame of Reference

CZASOPISMO TECHNICZNE TECHNICAL TRANSACTIONS ELECTRICAL ENGINEERING ELEKTROTECHNIKA 1-E/2015

Design On-Line Tunable Gain Artificial Nonlinear Controller

The Modelling, Simulation and Control of a 50 kw Vertical Axis Wind Turbine

Speed Control of PMSM by Fuzzy PI Controller with MPAC Algorithm

International Journal of Advance Engineering and Research Development

Sensorless Field Oriented Control of Permanent Magnet Synchronous Motor

I. INTRODUCTION. Index Terms Speed control, PID & neural network controllers, permanent magnet Transverse Flux Linear motor (TFLM).

Assessment of Power Coefficient of an Offline Wind Turbine Generator System

Transcription:

International Journal of Modern Nonlinear Theory and Application, 16, 5, 1-1 Published Online March 16 in SciRes. http://www.scirp.org/journal/ijmnta http://dx.doi.org/1.436/ijmnta.16.511 Advanced Control of a PMSG Wind Turbine Hafsi Slah, Dhaoui Mehdi, Sbita Lassaad National Engineering School of Gabes, Photovoltaic, Wind and Geothermal Systems Research, Gabes, Tunisia Received 4 July 15; accepted 8 February 16; published March 16 Copyright 16 by authors and Scientific Research Publishing Inc. This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4./ Abstract In this work, an intelligent artificial control of a variable speed wind turbine (PMSG) is proposed. First, a mathematical model of turbine written at variable speed is established to investigate simulations results. In order to optimize energy production from wind, a pitch angle and DC bus control law is synthesized using PI controllers. Then, an intelligent artificial control such as fuzzy logic and artificial neural network control is applied. Its simulated performances are then compared to those of a classical PI controller. Results obtained in MATLAB/Simulink environment show that the fuzzy and the neuro control is more robust and has superior dynamic performance and hence is found to be a suitable replacement of the conventional PI controller for the high performance drive applications. Keywords Wind Turbine, Variable Speed, Pitch Angle, Pi Controller, Fuzzy Logic Controller, Neural Networks Controller 1. Introduction Nowadays, among the all renewable energy sources, wind systems are more economic in comparison with others. Variable wind speed systems deliver % to 3% more energy in comparison with constant speed systems [1]. Many developed generation systems are used to extract maximum wind energy. Optimum wind energy extraction system is achieved by running wind turbine generator in a variable speed mode because of the higher energy gain and reduced stresses []. Pitch-adjusting variable-speed wind turbines have become the dominating type of yearly installed wind turbines in recent years. Pitch angle regulation is required in conditions above the rated wind speed when the rotational speed is kept constant. The diagram of Figure 1 illustrates the general principle of the regulation of a pitch angle. How to cite this paper: Slah, H., Mehdi, D. and Lassaad, S. (16) Advanced Control of a PMSG Wind Turbine. International Journal of Modern Nonlinear Theory and Application, 5, 1-1. http://dx.doi.org/1.436/ijmnta.16.511

PMSG AC DC DC Bus DC AC generated power Pitch Rotor speed Control Pg Wind speed System management. Wind Turbine Model Figure 1. Control diagram of the pitch angle. Wind turbine converts wind energy into mechanical energy. For a variable-speed, mechanical power available at the output of the wind turbine could be expressed by: 1 = ( λβ, ). (1) 3 Pm ρ S v Cp Here, ρ is the air density, S = π R is the blades swept of the turbine, V is wind speed, and C P (λ,β) is the power coefficient, which expresses the relationship between the tip speed ratio λ and the pitch angle β. The mechanical power captured by the wind turbine is obtained as: ( βλ, ) 1 C C R v λ 3 P m = ρ π. () The power coefficient C P (β,λ) is a nonlinear function of the tip speed ration λ and the pitch angle β given by: C P ( ) 1 λ i 116 λβ, =.5176.4 β 5 e +.68 λ λi (3) where: 1 = 1.35. 3 λ λ+.8 β 1+ β i The relationship between the wind speed and the rotor speed is defined as tip speed ratio λ: λ R Ω where Ω m is the blades angular velocity and R is the rotor radius. The developed turbine torque is: m = (4) v Pm C =. (5) Ω m The relationship between the turbine power and turbine speed at maximum power output are given by:.1. Pitch Angle Control 1 Pmax = ρ π Cp max R Ω λ 3 opt m 5 3 opt Wind turbines are generally designed to deliver maximum output at wind speeds around 15 m/s [3]. According to equation (1), for a given wind speed, the only parameter that allows to control extracted power is the Cp pa-. (6)

rameter (Figure ). This parameter depends on the type of turbine and the type of design from the manufacturer. It is also a function of the pitch angle control, were mainly used to limit the mechanical power during strong wind speed or to adapt power production (Figure 3). The aerodynamic behavior of the wind turbine can be controlled actively by varying the turbine blade angle around their longitudinal axis [4]. In low and medium wind speed, the pitch angle control is rarely actuated and only set to the optimum value. In high wind speeds, the pitch angle control effects to regulate the extracted wind power so that the design limits of the turbine will not be exceeded. Rotor speed, torque or power control can be taken to regulate the pitch angle [5]. In this paper, the power error criteria are used. The error between the reference and the measured power at the output of the PMSG is sent to a PI controller to generate the reference value β ref of the pitch angle [6]... PI Control for the Pitch Angle The control system structure used to generate the pitch angle reference is depicted in Figure 4. Figure. Typical CP versus (β, λ) curve. 3 V=11 m/s 5 Power P m (W) 15 1 V=9 m/s V=7 m/s 5 V=5 m/s 4 6 8 1 Ω(rad/s) Figure 3. Turbine power versus wind speed. 3

P ref + - β ref PI Figure 4. PI controller of the pitch angle. The feed forward term assumes that all the components are ideal and does not account for the losses in the system. The feedback path compensates for the losses by decreasing the pitch angle, if the output power is less than the desired power, to increase the power captured..3. Fuzzy Logic Control for the Pitch Angle Fuzzy logic control is one of the most powerful control methods where based on fuzzy set theory and associated techniques. The fuzzy logic algorithm is suitable for wind turbine control with complex nonlinear models and parameters variation. The fuzzy controller (Figure 5) uses the perturbation and observation to track the optimal pitch angle without knowledge of wind turbine characteristic. Basic structure of the fuzzy logic controller consists of three important stages: Fuzzification, Decision Making Unit and Defuzzification Unit. The inputs of the Fuzzification are selected as error and rate of change of error and the output is the pitch angle reference. The two input variables are calculated at every sampling instant say k [6]. ( ) = ref ( ) g ( ) e( k) e( k 1) e k P k P k e = where, P ref (k) and P g (k) are respectively the reference and generated power at instant n. In Fuzzification stage the crisp variables e(k) and e(k) are converted into fuzzy variables which can be identified by membership function (Figure 6). The proposed controller uses following linguistic labels cited in Table 1. NB (Negative Big), NS (Negative Small), Z (Zero), PM (Positive Small), PB (Positive Big). The input and output variables map into the following fuzzy set (Figure 6). The triangular membership functions are used to define both inputs (error, rate of change of error) and output (pitch angle)..4. Simulation Results For evaluating the robustness of the fuzzy logic controller compared with the conventional PI controller at variable wind speed, the simulations (Figure 7) have been carried out using MATLAB/Simulink software. Figure 7 shows the results of the conventional pitch angle control strategy where power is used as the controlling variable. The comparisons of different strategies show that proposed fuzzy logic control strategies is more robust in pitch angle control. 3. Model of the PMSG P g The wind turbine drives a permanent magnet synchronous generator PMSG. By considering only the fundamental harmonic of the flux distribution in the air-gap of the machine and by neglecting the homopolar component, the theory of the space vector gives the dynamic equations of the stator currents as follows: T dids vds = Rs ids + Ls p. Ω Ls iqs dt diqs vqs = Rs iqs + Ls + p. Ω Ls ids + p Ω ϕ f dt s (7) (8) 4

P ref + - e d/dt e β ref + - Wind speed Pitch Servo β Wind Turbine + Generator Power P g Figure 5. Fuzzy logic control strategy of the pitch angle. NB NS Z PS PG NB NS Z PS PG NB NS Z PS PG 1.5 1.5.5 1 1.5 1.5 1.5.5 1 1.5 1.5 1.5.5 1 1.5 e e β Figure 6. Fuzzy inference system. Wind speed(m/s) 15 1.5 1 7.5 5 1 3 4 5 6 7 8 9 1 Pitch Angle (degree) 5 4 PI Fuzzy Logic 3 1 1 3 4 5 6 7 8 9 1 Power (W) 15 1 5 Figure 7. Comparisons of pitch angle control strategies. Table 1. Inference rules for pitch angle. PI Fuzzy Logic 1 3 4 5 6 7 8 9 1 Time (s) e e NB NS Z PS PB NB NB NB NS NS Z NS NB NS NS Z PS Z NB NS Z PS PS PS NS Z PS PS PB PB Z PS PS PB PB 5

where R s is the phase resistance of the stator winding, L s is the stator cyclic inductance, Φ f is the flux of the permanent magnetic, v ds and v qs are the d-q components of the stator voltages respectively, i ds and i qs are the d-q components of the stator currents respectively, and p is the number of pairs of poles. The mechanical model of the PMSG wind turbine can be described by the simplified motion equation: where the electromagnetic torque is: dω Te Tr = Jm + f Ω dt (9) P Te = 1.5 ϕ f iqs = ke iqs. (1) 4. DC Bus Control The generator-side inverter is controlled to catch maximum power from available wind power. According to (1), in order to control the electromagnetic torque T e, this study just controls the q-axis current i qs with the assumption that the d-axis current i ds is equal to zero. Furthermore, [7] [8] show that, in order to catch maximum power, the optimum value of the rotation speed is adjusted. The tip speed ratio λ is taken into account due to the equation being addressed as follow: λopt V Ω ref =. (11) R There, Ω ref is the blade angular velocity reference and λ opt is the tip speed ratio optimum. 4.1. Fuzzy Logic Controller for DC Bus The fuzzy logic controller for the DC bus has three parameters (Figure 8). The first input is the error of DC voltage, the second is the rate of change of error and the output is the power controlling current component. The inputs variables are calculated at every sampling instant say k [9]. ( ) = DCref ( ) DC ( ) e( k) e( k 1) e k V k V k e = T s where, ref (k) and (k) are respectively; the reference and measured voltage at instant n. In Fuzzification stage the crisp variables e(k) and e(k) are converted into fuzzy variables which can be identified by membership function. The fuzzification maps the error and change in error to linguistic labels of fuzzy sets. The proposed controller uses following linguistic labels in Table : NB (Negative Big), NM (Negative Medium), NS (Negative Small), NVS (Negative Very Small), Z (Zero), PVS (Positive Very Small), PM (Positive Medium), PB (Positive Big). (1) e ref d/dt e P ref 1/ke i qsref Ω ref Figure 8. Fuzzy DC bus controller. 6

4.. Neural Network Controller for DC Bus In this section a procedure for constructing a neural network model predictive controller for the voltage DC is presented. In practice, an operational load shedding scheme for bulk power systems should be able to incorporate an infinite number of possible system states that would be mapped to a finite number of actions. The training set should contain both the standard normal operational conditions and the state of parameters necessary to implement the appropriate action for system stability. Once the training process is completed, the benefits of the systems are immediately evident in the speed of response to faults and the seamless integration with existing power system controls. Load shedding neural networks are composed of an input layer, two hidden layers and one output layer. As mentioned earlier, using the model reference control tool in neural networks, it is possible to include a network control (Figure 9) with the transformer model to monitor the performance of the system [1]. The activation function of both the output layer are linear and unbiased while that of the hidden layer is sigmoid and biased. Training the neural network is often done in epochs or cycles that are based largely on the inputs into the system. So for various inputs, the neural network basically compares each input to other known inputs and plots a graph of the error gradient between these two values. The process of comparison is carried out for as many random inputs as possible while each result and the corresponding response of the Plant are stored for future reference. 4.3. Simulation Results and Discussion In order to evaluate the performance of the control system for the variable DC bus reference concept with PMSG, we set reference to 1 V. In the first next we shoes V and finally we shoes 4 V. Figures 1-1 show the responses of the system when using respectively IP, fuzzy logic and neural controllers. From Figure 13, showing the comparison of the three responses; we note that the use of fuzzy provides a response with a smaller overshoot and faster compared to the neural controller and conventional IP controller. Table. Rules table for DC bus. e e NB NM NS Z PS PM PB NB NB NB NB NB NS NP Z NM NB NB NB NS NP Z PS NS NB NB NS NP Z PS PM EZ NB NS NP Z PS PM PB PS NS NP Z PS PM PB PB PM NP Z PS PM PB PB PB PB Z PS PM PB PB PB PB e(k) e(k) P ref P(k-1) delay Figure 9. Neural network model. 7

Figure 1. DC voltage response with PI controller. 5 ref 4 3 1 1 3 4 5 t(s) 6 7 8 9 1 Figure 11. DC voltage response with fuzzy logic controller. 5 4 3 ref 1-1 - -3 1 3 4 5 t(s) 6 7 8 9 1 Figure 1. DC voltage with neural network controller. 8

5 4 ref 3 neurone flou PI 1-1 - 5. Conclusions Figure 13. Comparison between the deferent controllers. This paper analyzes the control strategies as well as models and designs and simulates the whole autonomous system of PMSG wind turbine feeding AC power to the utility grid. In the first part of this work, we studied the control of the pitch angle. The proposed method is based on fuzzy logic and PI controller for tracking the optimal pitch angle of wind turbine with a variable speed. The capability of the fuzzy logic controller is verified and it is found that it has a fast response than the conventional PI controller. In the second part, three techniques were tested: PI, fuzzy logic and neural networks to control the DC bus side generator. The simulation results show that the combination of pitch angle controller and DC bus controller has good dynamic and static performance. The maximum power can be tracked and the generator wind turbine can be operated in high efficiency. DC-link voltage is kept at stable level for decoupling control of active and reactive power. Hence, the output will get the optimum power supply for the grid. References -3 1 3 4 5 t(s) 6 7 8 9 1 [1] Nguyen, H.M. and Naidu, D.S. (11) Advanced Control Strategies for Wind Energy Systems. IEEE PES Power Systems Conference & Exposition (PSCE), Phoenix, -3 March 11, 1-8. http://dx.doi.org/1.119/psce.11.577514 [] Yin, M., Li, G., Zhou, M. and Zhao, C. (7) Modeling of the Wind Turbine with a Permanent Magnet Synchronous Generator for Integration. IEEE Power Engineering Society General Meeting, Tampa, 4-8 June 7, 1-6. http://dx.doi.org/1.119/pes.7.38598 [3] Merabet, A., Thongam, J. and Gu, J. (11) Torque and Pitch Angle Control for Variable Speed Wind Turbines in All Operating Regimes. 1th International Conference on Environment and Electrical Engineering (EEEIC), Rome, 8-11 May 11, 1-5. http://dx.doi.org/1.119/eeeic.11.5874598 [4] Rolan, A., Luna, A., Vazquez, G., Aguilar, D. and Azevedo, G. (9) Modeling of a Variable Speed Wind Turbine with a Permanent Magnet Synchronous Generator. IEEE International Symposium on Industrial Electronics (ISIE), Seoul, 5-8 July 9, 734-739. http://dx.doi.org/1.119/isie.9.5181 [5] Yao, X.J., Liu, Y.M., Xing, Z.X. and Zhang, C.M. (8) Active Vibration Control Strategy Based on Expert PID Pitch Control of Variable Speed Wind Turbine. International Conference on Electrical Machines and Systems (ICEMS 8), Wuhan, 17- October 8, 635-639. [6] Veeramani, C. and Mohan, G. (11) A Fuzzy Based Pitch Angle Control for Variable Speed Wind Turbines. IEEE Student Conference on Research and Development (SCOReD), Cyberjaya, 36-39. [7] Li, S., Haskew, T.A. and Xu, L. (1) Conventional and Novel Control Designs for Direct Driven PMSG Wind Turbines. Electric Power Systems Research, 8, 38-338. http://dx.doi.org/1.116/j.epsr.9.9.16 [8] Chinchilla, M., Arnaltes, S. and Burgos, J.C. (6) Control of Permanent-Magnet Generators Applied to Variable- Speed Wind Energy Systems Connected to the Grid. IEEE Transactions on Energy Conversion, 1, 13-135. http://dx.doi.org/1.119/tec.5.853735 [9] Chen, J., Wu, H.B., Sun, M., Jiang, W.N., Cai, L. and Guo, C.Y. (1) Modeling and Simulation of Directly Driven 9

Wind Turbine with Permanent Magnet Synchronous Generator. Proceedings of the 1 IEEE Innovative Smart Grid Technologies, Asia, May 1, 1-5. [1] Rubén Tapia, O., Omar Aguilar, M., Abel García, B. and Omar J. Santos, S. (13) Adaptive PI Controllers for Doubly Fed Induction Generator Using B-Spline Artificial Neural Networks. International Journal of Computer Applications, 8, 37-4. http://dx.doi.org/1.51/13956-1949 Parameters Wind turbine parameters: P T = W R = 1.5 m λ opt = 8.1 C p =.48 J T = 16 kg m PMSG generator parameters: P g = 17 W n = 15 rpm J =.6 Kg m p = R s = 3.8 Ω L d = L q =.7 mh Ф f =.341 Wb 1