INSTRUCTION MANUAL Fax: (503)

Similar documents
Dual laser + type K thermometer INFRARED THERMOMETER

INSTRUCTION MANUAL DTH Fax: (503)

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

566/568. Infrared Thermometers. Getting Started

Instruction Manual SEFRAM Thermal Camera

InfraRed Thermometer with Laser Pointer

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

INSTRUCTION MANUAL INF Fax: (503)

IR/Thermistor Pen. Instruction Manual

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual

Today s Weather 24 Hour Forecaster

63/66/68. Infrared Thermometers. Users Manual

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

INFRARED THERMOMETER TM0819

Introduction Cautions

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

INFRARED THERMOMETER Model : TM-959

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

CAUTION: BEFORE YOU BEGIN, ALWAYS MAKE SURE THE WEAPON IS UNLOADED AND SAFE TO HANDLE.

SKELESCOPE REFLECTOR TELESCOPE WITH TABLE TOP TRIPOD SK-100 INSTRUCTION MANUAL

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

Instruction Manual HI Refractometer for Invert Sugar Measurements

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

WS-7211U Wireless 433 MHz Weather Station. Instruction Manual

Infrared Thermometer Model: and

INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

Traceable Big-Digit Type-K Thermometer Big digits are readable from 15 feet away. For additional Type-K probes, see page 41.

Noncontact Thermometer

Mini Environmental Quality Meter

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

Wireless Weather Station. Instruction Manual

Hadrons Desktop U.S. Atomic Clock & Weather Station

One-Year Limited Warranty

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

FIELD GUIDE FOR HORUS SCOPES

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

INSTRUCTION MANUAL Milwaukee Refractometer MA872 Refractometer for Fructose Measurements

2 ACCESSING VARIOUS MODES

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

SkyScan EWS-PRO - Manual -

Instruction Manual HI Refractometer for Sodium Chloride Measurements

WHEN BRIGHTNESS COUNTS

Infrared Thermometer Model CA879

Operator's Manual. optris BR 400. Calibration source

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

IR-712 IR-712-EUR 12:1 Infrared Thermometer. IR-720 IR-720-EUR 20:1 Infrared Thermometer. IR-730 IR-730-EUR 30:1 Infrared Thermometer.

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Wireless Color Forecast Station Model: K86319

U.S. Atomic Clock & Weather Station. Instruction Manual

Instruction Manual HI Refractometer for Sucrose in Wine and Grape Products Measurements

WS-7038U Wireless 433 MHz Miniature Rain Monitor. Instruction Manual

INF195 Infrared Thermometer

WS-9018U Wireless Weather Station. Instruction Manual

WeatherHub2 Quick Start Guide

SUGAR/BRIX REFRACTOMETER INSTRUCTION MANUAL

Manual Dew point scanner PCE-DPT 1

DIGITAL THERMOMETER WITH TRICOLOR LCD INSTRUCTION MANUAL

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

MEASURE MASTER PRO. Pocket Reference Guide. Model FEET-INCH-FRACTION and METRIC CALCULATOR

Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

WS-7213U Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS. Figure 2. Figure 1

CAUTION: BEFORE INSTALLATION, CONFIRM THAT THE CROSSBOW IS UNLOADED AND IS IN SAFE OPERATING CONDITION.

6.Ebz!boe!8.Ebz!!! Gpsfdbtufst!!! G U I D E n catio Lo

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

USER MANUAL REFLEX SIGHT. Ultra Shot Z Series. English / Francais / Español / Deutsch

R I T. Title: GCA Stepper Operations. Semiconductor & Microsystems Fabrication Laboratory Revision: F Rev Date: 08/09/ SCOPE

TG646 WEATHER STATION

MAGMA NOTE! 21+ USER MANUAL

IRTS-P PRECISION INFRARED TEMPERATURE SENSOR INSTRUCTION MANUAL

RADIATION-METER TM-91/TM-92

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

Instructions for use: Pushtronex System for Repatha (ri-path-a) (evolocumab) Single-Use On-Body Infusor and Prefilled Cartridge.

MEASURE MASTER 5. FEET-INCH-FRACTION and METRIC CALCULATOR. Model 4018 v3.1

ph 5 Meter Manual The LaMotte 5 Series

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

Rapid RH Portable ph Meter. User's Manual

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

Wireless Weather Station Instruction Manual

Model: 53005/ Printed in JAPAN 2012/05

Anemometer Thermometer Hygrometer

Instruction Manual HI 96759C Maple Syrup Transmittance Analyzer

OPERATING INSTRUCTIONS

DWT-10 Instruction Manual

Fischer Banjo Weather Station with Thermometer, Hygrometer, Barometer User Manual

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

WT-3131A Radio-controlled Analog Clock With Weather Forecast. Instruction Manual

The Weather Station FEATURES:

Since Mechanical Clocks Barometers. Owner s Manual

MODEL 107 TEMPERATURE PROBE INSTRUCTION MANUAL

15 E OWNER S MANUAL PIRATE SPYGLASS BRING EM NEAR PIRATE SPYGLASS TELESCOPE 5 W 30 W 60 W 45 W

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

Transcription:

INSTRUCTION MANUAL 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com email: info@ueitest.com

Introduction The INF 215 is perfect for frequent use in advanced or specialty applica t i o n environments, where wide temperature ranges and superior optics are essential for use on targets at greater distances. A UV Worklight has been added to diversify the INF 215 s use. This full-featured IR Thermometer is the most comprehensive and best-valued Infrared Thermometer on the market. C o n t rols and Indicators 6 The INF 185 s increased features offer advanced trend analysis for professionals that require a greater quality of infrared optics, extended measurement and the versatility of a K-Type surface or contact probe. A worklight has been added to allow visibility in low-lit workspaces. Features include (INF215) -76 to 1400 F 30:1 Distance to Spot Ratio UV Worklight 1 5 Features include (INF185) -76 to 932 F 12:1 Distance to Spot Ratio Worklight - Bright white Shared... MIN/MAX/Differential, Average Adjustable emissivity levels Hi/Lo Alarm (User adjustable) Contact probe input Over-molded handle with comfort grip Carry Case Safety Notes 4 1. Trigger: Initiates measurements. 2. IR Sensor 3. Laser Pointer Beam 4. Worklight: INF185 = white INF215 = UV 5. Battery Compartment 6. Thermocouple Socket Front view 2 3 Before using this infrared thermometer, read all safety information carefully. In this manual the word "WARNING" is used to indicate conditions or actions that may pose physical hazards to the user. The word "CAUTION" is used to indicate conditions or actions that may damage this instrument. Displays and Indicators NOTE: The INF185/INF215 is not recommended for use on shiny surfaces such as chrome, mirrors or polished metals. To avoid thermal shock, the instrument should be stored at room temperature between 32 to 122 F (0 to +50 C). 7 6 2 5 4 3 1 DO NOT look directly into the laser beam. Permanent eye damage may result. 1. Mode Push-button 2. Lock and Backlight ( ) Push-button 3. F/ C and Laser ( ) Push-button 4. Value labeled parameters 5. Scale 6. Battery level 7. Hi/Lo Alarm 8. Scan indicator 9. Backlight 10. Laser splash 11. HOLD 12. LOCK 13. Polarity 14. MIN, MAX, DIF, AVG, E, E, PRB INF185/215-MAN P. 1

Operating Instructions Taking Measurements To take a temperature measurement using your INF185/215, you simply point the aperture at an object (with or without using the laser sighting) and pull the trigger. The object s temperature will show up on the display and update at a rate of approximately 2 times per second. There will be a delay of approximately one-second between the time you initially pull the trigger and the time the display comes on. The 60- second auto-hold initiates at the moment you release the trigger. The m aximum temperature is viewed beside the icon. NOTE: This thermometer will automatically shut off if left idle for more than 60 seconds, unless in PRB mode. When in PRB mode, instrument will shut off if left idle for more than 12 minutes. Follow these general guidelines to ensure you get the most accurate readings possible: Be sure the measured object fills the "spot" seen by the aperture. The distance to spot ratio for the INF185 is 12:1. The distance to spot ratio for the INF215 is 30:1. This shows the one-foot spot fitting within the one-foot target area. At this distance, and anything closer, the target s temperature will be accurately measured (Fig 1). NOTE: If the two-foot diameter spot includes unwanted objects in the background that are not part of the one-foot square target. The temperature of the background objects will be figured in with the target s temperature and throw off your measurement. Be aware that you cannot measure the temperature of air between the Infrared thermometer and an object. Air vents (registers) are quick to take on the temperature of outlet air. However, you must aim directly at the vent if you are measuring outlet air temperature. Keep your infrared thermometer away from strong electrical fields. When working near a strong electrical field, like that under the hood of your car, watch for unusual readings or an "over load" indication. Often, you can move the thermometer just a few inches to escape the influence of the interference. Keep your INF185/215 within its use and storage temperature range. Excessive heat or cold will adversely affect the accuracy of your readings. When the trigger is pulled the target s temperature will be displayed in a near real-time mode (less than 1/2 second between measurements). The temperature will remain on the dis play for seven seconds after the trigger is released. Mode and Functions Press the MODE push-button will scroll through the following options: : E m i s s i v i tydata. (The default emissivity is 0.95) : Press the MODE push-button, then press or push-buttons to set the emissivity, then press the MODE push-button again to confirm it. The emissivity can be changed from 0.10 to 1. : Press the MODE push-button for the maximum (MAX), minimum (MIN), different between MAX and MIN (DIF) and average (AVG) modes. During the measurement, the special modes reading will be displayed at the bottom of the display near the mode icon. When comparing temperatures of similar objects that are far away, take your measurements at the same distance and angle to the target each time. When looking for abnormally hot or cold targets it may be acceptable to include background objects so long as the temperatures in the background and your methods are consistent. Consider the emissivity of the objects you are measuring. (Fig 1) Prepare a surface for measurement. Infrared thermometers measure only the outer surface of an object. If emissivity is affecting the measurement, or you have difficulty putting the object in the sensors line-of-site, you may need to prepare a surface that s easy for the infrared thermometer to read. A piece of masking tape is a good target and it will rapidly take on the temperature of the object it is attached to. : Press the or push-buttons to change the High Alarm (HAL) or Lo Alarm (LAL), then press the trigger to confirm it. For example: when the reading 27 C < LAL 27.1 C, the low Lo Alarm icon will flash and you will hear a beep sound. : Connect the thermocouple to the thermocouple socket and apply the probes to the target being measured. The thermometer will display the temperature automatically without pressing any buttons. To see the minimum or m aximum data during the probe measurement, please hold down the or push-buttons. After measurement of high temperature, the probe may be hot for a while. INF185/215-MAN P. 2

Additional Features Perform this first Verify that the meter Press to activate the following is in one of these modes Press and release In MIN, MAX, DIF, LOCK - Press the pushthe trigger to activate AVG mode button for LO CK mode ON/OFF display first - This locks the IR measurement for up to 60 minutes SCA L E - Press push-button to select C or F Press and release In all modes BACKL IGHT / WORKL IGHT - the trigger to use Press the p u s h - b u t t o n these functions for backlight function ON/OFF LASER - Press the pushbutton for laser function ON/OFF Changing Scales To change scales between degrees Fahrenheit and degrees Celsius, press the button on the panel, (marked F / C), while the display is active. Even if the trigger is released and the display is in its 60-second automatic hold, you can convert the reading between scales. Each time you press the scale button, the 60-second hold will reset. The INF155 will default to the scale last used the next time it is turned on. Using the Laser Sight The INF185/215 is classified as a "Laser Product", and is regulated by the FDA. Using controls, making adjustments, or performing procedures in any manner other than that specified herein may result in hazardous radiation exposure. LCD Error Messages The thermometer incorporates visual diagnostic messages as follows: : H i or L o is displayed when the temperature being measured is outside the settings of HAL and LA L. : E r 2 is displayed when the thermometer is exposed to rapid changes in the ambient tempera t u r e. : E r 3 is displayed when the ambient temperature exceeds the operation range of 32 to 122 F (0 to 50 C). The thermometer should be allowed plenty of time (minimum 30 minutes) to stabilize to the working/room tempera t u r e. : For all other error messages it is necessary to reset the thermometer. Battery Indicators The thermometer incorporates visual low battery indications. Periodic Service : Battery OK measurements are possible : Battery Low battery needs to be replaced, measurements are still possible : Battery Exhausted measurements are not possible M a i n t e n a n c e Repair and service of this instrument is to be performed by qualified personnel only. Cleaning Pe r i o d i cally clean your instrument s case using a damp cloth. DO NOT use abrasive, flammable liquids, cleaning solvents, or strong detergents as they may damage the finish, impair safety, or affect the reliability of the s t r u c t u ral components. Battery Replacement Always use a fresh replacement battery of the specified size and type. Immediately remove the old or weak battery from the meter and dispose of it in accordance with your local disposal regulations. Old or defective batteries can leak chemicals that corrode electronic circuits. To replace the battery: 1. Slide the battery cover straight down then away from the INF185/215 (Fig 2). 2. Replace with fresh AAA (2x) batteries. 3. Replace cover. To reset the thermometer, turn the instrument off, remove the battery and wait for a minimum of one minute. Reinsert the battery and turn it on. If the error message remains please contact UEi service department for further assistance. AAA (x2) (Fig 2) INF185/215-MAN P. 3

Lens Care The sensor lens is the most delicate part of the thermometer. The lens should be kept clean at all times. Care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. Allowing the lens to fully dry before using the thermometer. Do not submerge any part of the thermometer in liquids. Under NO circumstance should you expose batteries to extreme heat or fire as they may explode and cause injury. NOTE: This instrument contains no user serviceable parts. If service becomes necessary, call UEi and ask for the service department. See the warranty section of this manual for additional details. INF185 Specifications Item Non-contact Infrared Scan Thermocouple Probe Scan Measurement range -76 to 932 F -83.2 to +1999 F (-60 to +500 C) (-64 to 1400 C) Operating range 32 to 122 F (0 to +50 C) Accuracy (Tobj=-59-95 F, ±1.8 F (1.0 C) ±1% of reading or 1.8 F Tamb=77 C) (1.0 C) whichever is (Tobj=-27-932 F, ±2% of reading or 4 F greater (Test under Tamb=73 ±3 C) (2 C) whichever is greater Tamb=73±6 F) Resolution (-9.9-199.9 F) 0.10 F / 0.1 C Response time (90%) 1 second Distance: Spot 12 : 1 Battery life Standard AAA (x2), 140 hours Dimensions 6.9 x 1.5 x 2.8 (175.2 x 39.0 x 71.9mm) Weight 179 grams EMC/RFI Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per meter, but the performance of the instrument will not be permanently affected. IR Thermometers I n f rared Thermometers measure the amount of thermal radiation emitted from an objects surface. To take a measurement, the object must be within the field of view of the infrared thermometer, or the reading may include objects surrounding your target. This target size is determined in the distance to spot ratio stated on the instruments specifications. At a ratio of 9:1, a distance from your target of nine feet will give you a circle with one foot diameter. At 20:1 ratio gives the same one foot target n ow at 20 feet, so you can see that higher is better, but ty p i cally more expensive due to the cost of the optics involved. The other common question is regarding emissivity. In simple terms e m i s s i v i ty is a percentage of energy emitted from a surface compared to the energy emitted from a black body source. If a surface emits one half ( 1/2 or 0.5) the amount of energy at a given temperature and wavelengt h as a black body, it is said to have an emissivity of 0.5. Surfaces closest to the black body level would be flat black, and those farthest from it would be mirror or chrome surfaces. With a set emissivity level some surfaces may measure lower than actual, because their surface is emitting less thermal radiation at a given temperature. Although you may have a fixed emissivity of 0.95, most items measured will provide a reasonably accurate result. Having a fully adjustable emissivity will give you the ability to fine tune your instrument to a specific applica t i o n. To determine the emissivity of the surface being tested, paint a portion with flat black paint, and then measure the temperature of the painted area and compare it to the temperature of the standard surface. Use the following to determine the emissivity to use. Te m p e rature (Standard area) divided by temperature (painted area). As an example 61 in the standard area and 68 painted is 61/68 or 0.89 INF215 Item Non-contact Infrared Scan Thermocouple Probe Scan Measurement range -76 to 1400 F -83.2 to +1999 F (-60 to +760 C) (-64 to 1400 C) Operating range 32 to 122 F (0 to +50 C) Accuracy (Tobj=-59-95 F, ±1.8 F (1.0 C) ±1% of reading or 1.8 F Tamb=77 C) (1.0 C) whichever is (Tobj=-27-1400 F, ±2% of reading or 4 F greater (Test under Tamb=73 ±3 C) (2 C) whichever is greater Tamb=73±6 F) Resolution (-9.9-199.9 F) 0.10 F / 0.1 C Response time (90%) 1 second Distance: Spot 30 : 1 Battery life Standard AAA (x2)1.5v, 140 hours Dimensions 6.9 x 1.5 x 2.8 (175.2 x 39.0 x 71.9mm) Weight 179 grams NOTE: Under the electromagnetic field of 2V/m from 200 to 600 MHz, the maximum error is 18 F (10 C). INF185/215-MAN P. 4

INF185/215 Infrared Thermometer Limited Warranty The INF 18 5 / 215 is warranted to be free from defects in materials and workmanship for a period of three years from the date of purchase. If within the warra n ty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UEi s option. This warra n ty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper maintenance. Batteries and consequential damage resulting from failed batteries are not covered by warra n ty. Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss. A purchase receipt or other proof of original purchase date will be required before warra n ty repairs will be rendered. Instruments out of warra n ty will be repaired (when repairable) for a service charge. Return the unit postage paid and insured to: 1-800-547-5740 FAX: (503) 643-6322 www.ueitest.com Email: info@ueitest.com This warranty gives you specific legal rights. You may also have other rights which vary from state to state. PLEASE RECYCLE Copyright 2007 UEi INF185/215-MAN 1/07